C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Similar documents
C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

B 80.en. Single pole cam contactors for DC and AC applications C160, C162 Series. Connect - Contact - Control max. ED: 100% U 14,4V.

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Connect - Contact - Control. DC Contactors 600V / 750V / 1000V. F 215e

COMPONENTS. Power contactor Type BMS09.08 / BMS18.08

Connect - Contact - Control. Connectors. Short Form Catalogue

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

Output of three-phase motors at 50 Hz and 400 V

Controls Contactors and Contactor Assemblies Special Applications

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

Characteristics 5 TeSys k contactors and reversing contactors

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

NS..S contactor relays - with spring terminals AC operated

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Capacitor Switching Contactors

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

COMPONENTS. High power contactor Type BMS09.15 / BMS18.15 BMS09.18 / BMS18.18

High-Speed DC Circuit-Breakers for Fixed Installation Type UR26, UR36, UR40 & UR46

Technical features table for miniature circuit-breakers SH 200 Series

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Relay interface modules A

Safety switches with slotted hole lever

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Contactors and Contactor Assemblies

Power supply CP-E 24/2.5

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Power supply CP-D 24/4.2 Primary switch mode power supply

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Power supply CP-E 24/0.75

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22

Three-phase monitoring relay CM-PFS

Power supply CP-E 24/20.0

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

For non-electrical quantities

Measuring current transformers of the W, W series

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Description Basic devices with positive operation contacts

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Power supply CP-D 24/1.3

Electronic timer CT-SDD.22

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

48 Series - Relay interface modules A. Features

62 Series - Power relays 16 A. Features / /

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

Installation / Monitoring Technique

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

Power supply CP-D 12/2.1

38 Series - Relay interface modules A. Features /

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Power supply CP-E 24/2.5

Power supply CP-T 48/20.0 Primary switch mode power supply

Local control stations for Zone 1 and Zone 21. Features. Description

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

Liquid level monitoring relay CM-ENS.2x

62.22 Copper side view

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

Transformers, Power Supply Units and Socket Outlets

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

RELOG. All-or-nothing Relay

D4-U200 relay module - 4-pole

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

UBC 200 relay - Voltage monitoring

Type: DILEM 10 G(24VDC) Article No.:

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Transcription:

Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations! Connect - Contact - Control Power contactors for AC and DC CT1115 and CT1130 370 340 125 307 C20.en

2 Power contactors for AC and DC, Series CT Owing to a new blowout technology, CT Series contactors can be used in almost any AC or DC railway network, even in countries where the normal tolerances are exceeded. The single pole contactor ensures low-wear and reliable switching of both extremely low and very high loads. Double and triple pole styles are being developed. Especially robust and environmentally friendly materials, from plastics featuring low smoke and low content of toxic gases up to cadmium-free contact tips, are used for the CT1000. It has been tested and approved by independent laboratories. Features Compact, rugged design 2 breaking capacity levels, 4 current ratings Double-break contacts, (normally open) and cadmium-free contact tips 1, 2, and 3 pole versions Easy maintenance: Easy inspection and replacement of main contact tips Easy replacement of arc chute Drive system with coil tolerance according to railway standards, no economy circuit required! Functional insulation for main circuit Basic insulation between main circuit and protective earth Reinforced insulation between main circuit and control circuit / auxiliary circuit and protective earth Applications Main contactor for: traction motors convertors inverters for auxiliary equipment Contactor for: field circuits of motors conventional resistor based traction units (retrofit) starters and compressor motors Power switch for heating circuits Contactor for a host of industrial applications Standards IEC 60077: Railway applications Electric equipment for rolling stock EN 50124-1: Railway applications Insulation coordination Part 1: Basic requirements Clearances and creepage distances for all electrical and electronic equipment Ordering code Example: CT1130/04 H 110ET-00 Series CT11 1 pole NO contactor CT12 2 pole NO contactor CT13 3 pole NO contactor Nominal voltage 15 U n = 1,500 V 30 U n = 3,000 V Conv. thermal current 02 I th = 200 A* 1 04 I th = 400 A 08 I th = 800 A* 2 14 I th = 1,400 A* 1 Mounting position H Horizontal V Vertical Coil voltage 24 / 36 / 72 / 110 V DC Coil tolerance E -30 % +25 % Coil suppression T Suppressor diode Auxiliary switches, number and type 00 1x S870* 3 (a 1 ) 1x S870* 3 (b 0 ) M3 screw-type terminals 2x S826 a L* 4 01 1x S870* 3 (a 1 ) 1x S870* 3 (b 0 ) Flat tabs 6.3 x 0.8 2x S826 a L* 4 03 4x S826 a L* 4 M3 screw-type terminals 04 4x S826 a L* 4 Flat tabs 6.3 x 0.8 * 1 Series planned * 3 See also catalogue D70 * 2 Series in development * 4 See also catalogue D26 Presented in this catalogue are only stock items which can be supplied in short delivery time. Special variant If you need a special variant of the contactor, please do not hesitate to contact us. Maybe the type of contactor you are looking for is among our many special designs. If not, we can also supply customized designs. In this case, however, minimum order quantities apply.

125 246 260 3 CT1115/04 Dimension diagram single pole NO contactor for 1,500 V / 400 A Release button Indicator lever (open / locked) 346 318 274 163 min. 60 min. 65 min. 65 79 unlocking lever Main terminal screw M10 Aux. contact block Mounting plate screw 4x M6 8 WAGO 264 209 364 385 93.5 CT1130/04 Dimension diagram single pole NO contactor for 3,000 V / 400 A Release button Indicator lever (open / locked) 370 min. 65 min. 65 340 320 197 79 min. 60 unlocking lever Caution: Device contains unprotected active pieceparts. Device contains unprotected non-active pieceparts, which may interact with active pieceparts. Touch only after adhering to corresponding safety regulations! Main terminal screw M10 293 307 Aux. contact block 125 Mounting plate screw 4x M6 WAGO 264 209 364 385 8 93.5 Spare parts Ordering code MC CT1015/04 Description CT1115/04: Fixed contact, right / left Ordering code CC CT1030/04 Description Protective cover coil terminal MC CT1030/04 CT1130/04: Fixed contact, right / left CA CT1030/04 Protective cover auxiliary switch CB CT1030/04 CT1115/04 / CT1130/04: Contact bridge, moving S826 a L AS S870 Snap-action switch (SPDT) Switch group (momentary action switch) Reduced scale diagrams / dimensions in mm

4 Maintenance instructions Safety instructions Except for the main contacts and the arc chute, CT1000 Series contactors are maintenance free. The design allows easy access to all parts which require maintenance. So when installing the contactor, make sure that there is enough space to remove and replace the arc chute with ease and that the main contacts become accessible for inspection. The switching device meets the requirements of basic insulation. In addition to that, the bar onto which the drive of the contactor is mounted should be earthed in a vibration resistant way. The contactor has unprotected live parts and carries a label that warns of the hazard. This caution must be observed and the label must not be removed in any way. The required clearance to other live parts and earth is also to be observed as well as the safety regulations of the applicable standards. Mounting instructions Start up Before initial start up make sure that: the arc chute is mounted properly and the red levers are in locked position the contactor is earthed (PE terminal on mounting plate) Release button Indicator arc chute left: open position, right: locked position Important: Make sure arc chamber is latched properly in final position : Caution cted s unprote containrts. Device -active piecepa active cted non active s unproteinteract with y contain Device rts, which ma piecepa rts. g to erin s! piecepa y after adhty regulation onl Touch ding safe pon corres unlocking lever Coil suppression Coil suppression for reducing surges when the coil is switched off is optimally attuned to the contactor s switching behaviour. Caution: Parallel connection with a simple diode will override the existing coil suppression. Taking off the arc chute: 1. Push both release buttons in the direction indicated by the arrow and hold them in this position. 2. Move all four levers for unlocking the arc chute in the direction indicated by the arrow. 3. The arc chute incorporating the stationary main contacts can now be lifted from the contactor. Mounting the arc chute: 1. Mount the arc chute onto the magnetic drive. Note: The arc chute has keys on one side to fit into slots on the corresponding side of the contactor. So you cannot mount it the wrong way round. 2. Move all four levers for unlocking the arc chute into the original position. 3. Check: The arc chute is locked properly, if all four red indicator levers do not show above the casing. ED : 100% Ith : 400A Bj. : xxwyy coil UNI : 25kV UNM: 4800V vertikal mounting postion WAGO 264 Umax : 138V UNenn: 110V Umin : 77V Class C2 (n. IEC60077) Ue: 3600V / Ie: 200A / T=15ms Type: CT1130/04 V 110ET-00 Art.: 1-xxxx-xxxxxx Mounting plate screw 4x M6 Aux. contact block CT1130/04 V 110ET-00 Permissible mounting positions»h«horizontal»v«vertical Mounting holes 60 46 incorporating stationary main contacts Main terminal CT1115/04, CT1130/04 Mounting holes 4x Ø 6.6 ±0.1 334.5 364 (bottom view) Circuit diagram A1 Standard version with auxiliary switches S1, S2, S3 and S4: 4 x S826: CT1115/04, CT1130/04 Single pole version A1 A2 1 2 1 13 11+ 23 21+ 33 31+ 43 41+ Version acc. to railway standard IEC 60077 with aux. switches 14+ 12 24+ 22 32 44+ 42 S1 and A2 S2: 2 x S870 (a b0) as34+s3well as S3 and S4: 2 x S826: 2 1 and S2 S1 S4 CT1115/04, CT1130/04 Single pole version 13 11+ 23 21+ 33 31+ 43 41+ A1 14+ 12 S1 24+ 22 S2 34+ 32 S3 44+ 42 S4 A2 1 2 13 a1 14 S1 21 33 31+ 43 41+ 22 S2 34+ 32 S3 44+ 42 S4 b0

5 Specifications Series CT1115/04 CT1130/04 Kind of voltage DC (bidirectional), AC (f < 60 Hz) Main contacts, Number of, configuration 1x SPST-NO Nominal voltage U n 1,500 V 3,000 V Rated operating voltage U e 1,800 V 3,600 V Rated insulation voltage U i 2,300 V 4,800 V Rated impulse withstand voltage U imp 12 kv 25 kv Pollution degree Overvoltage category Switching overvoltages at U e = 1,200 V U e = 3,600 V PD3 OV3 < 6 kv < 11 kv Conventional thermal current I th 400 A 400 A Utilization category A2 A2 Short-circuit making capacity I cm Rated operating current I e (at frequency C2; T2 = 15 ms) U e = 1,200 V U e = 1,800 V U e = 3,600 V Short-circuit breaking capacity I cn (T2 = 15 ms) DC, U e = 1,200 V DC, U e = 1,800 V DC, U e = 3,600 V Short-circuit breaking capacity I cn (T2 = 1 ms) DC, U e = 1,200 V DC, U e = 1,800 V DC, U e = 3,600 V Short-circuit breaking capacity I cn (cosφ = 0.8) AC, U e = 1,200 V (f = 16.7 / 50 Hz) AC, U e = 1,800 V (f = 16.7 / 50 Hz) AC, U e = 3,600 V (f = 16.7 / 50 Hz) Short-circuit breaking capacity I cn (cosφ = 1) AC, U e = 1,200 V (f = 16.7 / 50 Hz) AC, U e = 1,800 V (f = 16.7 / 50 Hz) AC, U e = 3,600 V (f = 16.7 / 50 Hz) 3.5 ka (new contacts) / 5 ka (used contacts) 300 A *** 200 A 450 A *** 1,000 A 900 A / 500 A *** 1,100 A / 700 A *** 900 A 700 A 400 A 2,000 A 1,600 A 800 A 2,000 A / 1,200 A 1,600 A / 900 A 900 A / 500 A 2,500 A / 1,500 A 2,100 A / 1,200 A 1,300 A / 800 A Rated short-time withstand current I cw (T < 100 ms) 6 ka 6 ka Critical current range none none Main contacts Contact material Terminals Torque Auxiliary contacts Number and type Contact material S826 switching capacity, T = 5 ms Terminals, Flat tabs Magnetic drive Coil voltage U s Coil tolerance Coil power dissipation at U s and T a = 20 C Typical pull-in voltage at T a = 20 C Typical pull-in time at T a = 20 C Typical drop-off voltage at T a = 20 C Typical drop-off time at T a = 20 C Coil suppression Degree of protection Mechanical endurance Vibration / shock (EN 61373) Mounting position Temperature Operating temperature / Storage temperature Altitude / humidity (EN 50125-1) AgSnO 2 M10 15 Nm max. 1x S870 (a 1 ), 1x S870 (b 0 ), 2x S826 or optional 4x S826) Silver 16 A at 24 V DC; 13.5 A at 80 V DC; 7 A at 110 V DC (t = 5 ms DC) Screws M3 / Flat tabs 6.3 x 0.8 mm 24 / 36 / 72 / 110 V DC -30 %... +25 % U s cold coil: 55 W / warm coil: 40 W 0.6 x U s 120 ms 0.1 x U s 60 ms Suppressor diode Cage clamp IP00 > 2 million cycles Category 1, class B horizontal / vertical -40 C +70 C / -40 C +85 C < 2,000 m above sea level / < 75 % yearly average Weight < 11 kg < 13 kg *** Preliminary data, issued August 2008

6 RoHS 2002/95/EC manufactures in compliance with RoHS. has an environment management system that has been certified since 2002. has a quality management system that has been certified since 1994. Electrical Components and Systems for Railway Engineering and Industrial Applications Connectors Connectors manufactured to industry standards Connectors to suit the special requirements of communications engineering (MIL connectors) Charging connectors for battery-powered machines and systems Connectors for railway engineering, including UIC connectors Special connectors to suit customer requirements Snap-action switches Snap-action switches with positive opening operation Snap-action switches with self-cleaning contacts Enabling switches Special switches to suit customer requirements Contactors Single and multi-pole DC contactors High-voltage AC/DC contactors Contactors for battery powered vehicles and power supplies Contactors for railway applications Terminal bolts and fuse holders DC emergency stop switches Special contactors to suit customer requirements Electrics for rolling stock Driver s cab equipment Equipment for passenger use High-voltage switchgear High-voltage heaters High-voltage roof equipment Equipment for electric brakes Design and engineering of train electrics to customer requirements Klausenburger Strasse 6 81677 Munich Germany Phone +49 89 9 30 05-0 Fax +49 89 9 30 05-350 e-mail contact@schaltbau.de Internet www.schaltbau.com C1909/0809/1.0 Printed in Germany with compliments: We reserve the right to make technical alterations without prior notice. For updated product information visit www.schaltbau-gmbh.com. Issued September 2008