LXI -Certified 3.5mm, 2.4mm & 1.85mm Automated Tuners

Similar documents
LXI -Certified 2.4mm & 1.85mm Automated Tuners

LXI -Certified 7mm Automated Tuners

LXI -Certified 3.5mm Automated Tuners

LXI -Certified Multi-Harmonic Automated Tuners

LXI High-Gamma Automated Tuners (HGT ) And LXI High-Power Automated Tuners

LXI -Certified 7mm Automated Tuners

LXI High-Gamma Automated Tuners (HGT ) And LXI High-Power Automated Tuners

Cascading Tuners For High-VSWR And Harmonic Load Pull

Wide Matching Range Slide Screw Tuners DATA SHEET / 2G-035

1.85mm TRL/LRL Calibration Kits

Microwave & RF Device Characterization Solutions

MT1000 and MT2000 Mixed-Signal Active Load Pull System (1.0 MHz to 40.0 GHz) And MT2001 System Software

Vector-Receiver Load Pull Measurement

A New Noise Parameter Measurement Method Results in More than 100x Speed Improvement and Enhanced Measurement Accuracy

MEASUREMENT OF LARGE SIGNAL DEVICE INPUT IMPEDANCE DURING LOAD PULL

StabilityBench Microwave/RF Cable Assemblies

X-Parameters with Active and Hybrid Active Load Pull

RF Characterization Report

Type N Coaxial Calibration Kit

Test & Measurement Instrument Amplifiers

USER GUIDE 2.92mm Coaxial Calibration Kit

A Comparison of Harmonic Tuning Methods for Load Pull Systems

MACRO FILE AND DESIGN WINDOW COMPRESSION LOAD PULL MEASUREMENTS

IVCAD VNA Base Load Pull with Active/Hybrid Tuning. Getting Started v3.5

New Ultra-Fast Noise Parameter System... Opening A New Realm of Possibilities in Noise Characterization

Using Enhanced Load-Pull Measurements for the Design of Base Station Power Amplifiers

Focus Microwaves Inc. 970 Montee de Liesse, Ste. 308 Ville St-Laurent, Quebec H4T-1W7, Canada Tel Fax

Noise Calibration Systems and Accessories DATA SHEET / 4N-062

Coaxial TRL Calibration Kits for Network Analyzers up to 40 GHz

print close Chris Bean, AWR Group, NI

Impedance 50 (75 connectors via adapters)

Vector Network Analyzer Application note

Load-Pull Analysis Using NI AWR Software

Chapter 2 Passive Load-Pull Systems

PNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE

Computer Controlled Microwave Tuner - CCMT

PLANAR R54. Vector Reflectometer KEY FEATURES

Reflectometer Series:

There is a twenty db improvement in the reflection measurements when the port match errors are removed.

USER GUIDE. WR284 Waveguide TRL Calibration Kit GHz. Models: WR284C30\32 Series (Rev A) 03/16

S3602C Vector Network Analyzer Datasheet

ME1000 RF Circuit Design. Lab 4. Filter Characterization using Vector Network Analyzer (VNA)

Load Pull with X-Parameters A New Paradigm for Modeling and Design

On-Wafer Noise Parameter Measurements using Cold-Noise Source and Automatic Receiver Calibration

Focus Microwaves Inc. 277 Lakeshore Road Pointe-Claire Quebec, H9S-4L2, Canada Tel Fax Application Note 26

Precision Calibration & Interconnect Solutions

Managing Complex Impedance, Isolation & Calibration for KGD RF Test Abstract

Today s modern vector network analyzers

Validation & Analysis of Complex Serial Bus Link Models

Vector Network Analyzers T - Series

EXPERIMENT EM3 INTRODUCTION TO THE NETWORK ANALYZER

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

NATIONAL UNIVERSITY of SINGAPORE

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

Hot S 22 and Hot K-factor Measurements

Product Note 75 DLPS, a Differential Load Pull System

Improving Amplitude Accuracy with Next-Generation Signal Generators

Precision Calibration & Interconnect Solutions

Microwave Metrology -ECE 684 Spring Lab Exercise T: TRL Calibration and Probe-Based Measurement

Microwave Circuit Design and Measurements Lab. INTRODUCTION TO MICROWAVE MEASUREMENTS: DETECTION OF RF POWER AND STANDING WAVES Lab #2

On Wafer Load Pull and Noise Measurements using Computer Controlled Microwave Tuners

UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN )

Agilent Accurate Measurement of Packaged RF Devices. White Paper

Measurement & Modeling Device Characterization Solutions

5 ESSENTIAL HINTS TO IMPROVE Millimeter-wave Network Analysis

PXIe Contents CALIBRATION PROCEDURE

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

Keysight Technologies Nonlinear Vector Network Analyzer (NVNA) Breakthrough technology for nonlinear vector network analysis from 10 MHz to 67 GHz

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

Efficiency: 68% Temperature Range: +0 to 60 C Max VSWR: 5:1. Class: Supply Voltage:

Evaluation of Package Properties for RF BJTs

Introduction to On-Wafer Characterization at Microwave Frequencies

Measurement & Modeling Device Characterization Solutions

Measurement & Modeling Device Characterization Solutions

Circuit Characterization with the Agilent 8714 VNA

Aries Kapton CSP socket

Large-Signal Network Analysis Technology for HF analogue and fast switching components

AV3672 Series Vector Network Analyzer

Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements

S3602A/B Vector Network Analyzer Datasheet

Agilent PNA Series RF Network Analyzers

Vector Network Analyzer

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

TEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports

Aries QFP microstrip socket

AU4850 Pulsed IV/RF Characterization System

VSWR MEASUREMENT APPLICATION NOTE ANV004.

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

QuickSyn Frequency Synthesizers

Confidence. on the Cutting Edge. Vector Network Analyzer Portfolio Brochure. In the Lab On the Manufacturing Floor In the Field. Anritsu Since 1895

A Simplified QFN Package Characterization Technique

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.

7. Experiment K: Wave Propagation

Product Note 33. ALPS-308, Active Load Pull System for PCN Applications

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING The Edward S. Rogers Sr. Department of Electrical and Computer Engineering

Custom Interconnects Fuzz Button with Hardhat Test Socket/Interposer 1.00 mm pitch

Current Probe Fixture Instruction Manual

Wide-Band Two-Stage GaAs LNA for Radio Astronomy

Measurements with Scattering Parameter By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services

MFJ-2389 Compact 8 Band Vertical

Transcription:

LXI -Certified 3.5mm, 2.4mm & 1.85mm Automated Tuners DATA SHEET / 4T-050G04 MODELS: MT983BL01 MT984AL01 MT985AL01 // JANUARY 2018

What is load pull? Load Pull is the act of presenting a set of controlled impedances to a device under test (DUT) and measuring a set of parameters at each point. By varying the impedance, it is possible to fully characterize the performance of a DUT and use the data to: Example of load pull measurements with Output Power (Pout) contours plotted on a Smith Chart. > > Verify simulation results of a transistor model (model validation) > > Gather characterization data for model extraction (behavioral model extraction) > > Design amplifier matching networks for optimum performance (amplifier design) > > Ensure a microwave circuit s ability to perform after being exposed to high mismatch conditions (ruggedness test) Iso Pout Contours Measured @ 1.85 GHz > > Confirm the stability or performance of a microwave circuit or consumer product under non-ideal VSWR conditions (stability/performance/ conformance/antenna test) Iso Pout Contours Simulated @ 1.85 GHz 1

Slide-Screw Impedance Tuner One tool available to vary the impedances presented to a DUT is the slide-screw impedance tuner. The slidescrew tuner is based on a 50Ω slabline and a reflective probe, sometimes referred to as a slug. Ideally, when the probe is fully retracted, the tuner presents a near-50ω impedance represented by the center of a normalized Smith Chart. As the probe is lowered into the slabline (Y-direction) it interrupts the electric field that exists between the center conductor and walls of the slabline, reflects some of the energy back towards the DUT, creates a capacitance and increases the magnitude of reflection (represented by the red curve on the Smith Chart at right). As the probe travels along the slabline (X-direction), the distance between the probe and the DUT is altered, thereby rotating the phase of the reflection (represented by the blue curve on the Smith Chart). It is therefore possible to recreate nearly any arbitrary impedance without the need of discrete components (lumped elements or transmission lines). Simplified representation of a slide-screw tuner. (Side View) (End View) The probes used in slide-screw tuners are wideband in nature, and have similar reflective properties over a wide range of frequencies. In order to increase the overall useful bandwidth of the tuner, two probes of varying dimensions are independently used within a tuner; one for low frequencies and one for high frequencies. In this manner, it is common for slide-screw tuners to achieve an overall frequency range of several octaves to over a decade. VSWR versus Frequency of a two-probe slide-screw tuner. 2

Pre-Calibration (Pre- Characterization) Slide-screw tuners are available in both manual and automated varieties. While they both work on the same slabline and capacitive probe technique, automated tuners have the ability to be pre-calibrated. Pre-calibration involves recording the s-parameters of each probe at varying X and Y positions for the frequencies of interest using a calibrated vector network analyzer. In general, X and Y positions are selected such that an even distribution of impedances are recorded over the Smith Chart. Once the calibration data is stored in a lookup table, the VNA is no longer required to use the tuner; the tuner knows how to present impedances accurately without VNA verification. Tuner Repeatability Tuner repeatability is defined as the vector difference between the precalibrated s-parameter data and subsequent s-parameter measurements after movement, when returning the probe to a given X and Y position. Since the impedances presented to the DUT are reliant on the tuner s ability to accurately return to pre-calibrated states, repeatability is a critical tuner characteristic that affects the reliability of measurement data. In order to guarantee a high level of repeatability, precision mechanics and motors within the tuner are used to return the probe to its precalibrated positions with s-parameter vector differences of 40 to 50dB or better (see specific tuner model pages 6 through 8 for typical repeatability graphs). Tuning Accuracy and Interpolation During pre-calibration, the tuner s s-parameters are recorded at a userdefinable number (normally between 300-3000) of X and Y positions giving an even distribution over the Smith Chart. However, an arbitrary load impedance that falls between pre-calibrated states might be required. To achieve a high level of accuracy, a two-dimensional algorithm is used to interpolate between the closest pre-calibrated impedances in order to determine the new physical X and Y positions of the desired interpolated impedance. Interpolation increases the number of tunable impedances well beyond the initial precalibration range. Given a sufficiently dense pre-calibration look-up table, a tuner s repeatability (ability to return to pre-calibrated states) and accuracy (ability to interpolate between pre-calibrated states) offer similar performances. 3

Patented LXI -Certified Embedded Tuner Controller (U.S. Patent No. 8,823,392) All Maury slide-screw automated impedance tuners are equipped with a patented embedded LXI -certified controller (U.S. Patent No. 8,823,392) with onboard microprocessor and memory. After pre-calibration, the lookup table is copied onto the tuner s embedded flash memory storage, as are any s-parameter files of passive components that will be used with the tuner (adapters, cables, fixtures, probes, attenuators ). The tuner s onboard microprocessor will use the lookup table and component s-parameter blocks to calculate the probe positions required to present an arbitrary load impedance taking into account (de-embedding) all adapter/fixture losses between the tuner and DUT, and all back-side losses between the tuner and the measurement instrument, as well as possible non-50ω terminations. An integrated web interface allows for easy point-and-click tuning. Simply open Internet Explorer, Firefox, Chrome or any web browser in any operating system, and begin tuning. Capabilities include a graphic interface for de-embedded tuning at the DUT reference. Direct ASCII commands can be sent through raw TCP/IP interface over Ethernet or USB and used with any socket programming language or through any Telnet client program in any operating system. Commands include direct impedance tuning, reference-plane shifting, VSWR testing and more. 4

3.5mm, 2.4mm & 1.85mm LXI -Certified Automated Tuners Available Models Model Frequency Range (GHz) Matching Range Minimum Typical 1 Power Capability 2 Vector Repeatability (Minimum) Insertion Loss (Probes Fully Retracted) Connector Type Mating Surface Dimensions MT983BL01 2.0 26.5 10:1 15:1 25 W CW 250 W PEP 0.6 db 3.5mm 8.66" [22.0 cm] MT984AL01 8.0 50.0 10:1 20:1 10 W CW 100 W PEP 40 db 0.60 db 2.4mm 5.47" [13.88 cm] MT985AL01 8.0 65.0 10:1 20:1 10 W CW 100 W PEP 1.15 db 1.85mm 1 Defined as the minimum VSWR over 70% of the frequency range. 2 Power rated at maximum VSWR. Accessories Provided Each tuner is provided with one (1) MT1020F power supply, one (1) USB cable, one (1) Ethernet cable, one (1) USB to Ethernet adapter, and one (1) operating manual. Recommended Accessories 8799A1 Torque Wrench Recommended for tightening all 3.5mm, 2.92mm, 2.4mm & 1.85mm precision connectors to the proper in. lbs without over-torquing the connection. 8799A1 A050A 2.92mm/3.5mm Digital Connector Gage Kit Recommended for checking the critical interface dimensions of precision 2.92mm & 3.5mm connectors. A048A A048A 2.4mm/1.85mm Digital Connector Gage Kit Recommended for checking the critical interface dimensions of precision 2.4mm & 1.85mm connectors. Digital indicator style. A050A 5

Exemplary Performance Data for Model MT983BL01 3.5mm Automated Tuners VSWR versus Frequency for MT983BL01 automated tuners. Repeatability for MT983BL01 automated tuners. MT983 BL01 U.S. Patent No. 8,823,392 International Patents Pending Specifications Frequency Range -- 2.0 to 26.5 GHz VSWR Matching Range Minimum -- 10:1 Typical -- 15:1 1 Step Size (Probes) -- 62.5 microinches 2 Step Size (Carriage) -- 355 microinches 2 Connectors -- Precision 3.5mm, M/F 3 Power Capability -- 25 W CW; 250 W PEP 4 Vector Repeatability (Min.) -- 40 db Insertion Loss (probes fully retracted) -- 0.6 db 1 Defined as the minimum VSWR over 70% of the frequency range. 2 Based on 1/2 stepping the drive motors. 3 Precision 3.5mm per Maury data sheet 5E-062. 4 Power rated at maximum VSWR. 6

Exemplary Performance Data for Model MT984AL01 2.4mm Automated Tuners VSWR versus Frequency for MT984AL01 automated tuners. Repeatability for MT984AL01 automated tuners. MT984 AL01 U.S. Patent No. 8,823,392 International Patents Pending Specifications Frequency Range -- 8.0 to 50.0 GHz VSWR Matching Range Minimum -- 10:1 Typical -- 20:1 1 Step Size (Probes) -- 31 microinches 2 Step Size (Carriage) -- 50 microinches 2 Connectors -- Precision 2.4mm, M/F 3 Power Capability -- 10W CW; 100W PEP 4 Vector Repeatability (Min.) -- 40 db Insertion Loss (probes fully retracted) -- 0.60 db 1 Defined as the minimum VSWR over 70% of the frequency range. 2 Based on 1/2 stepping the drive motors. 3 Precision 1.85mm per Maury data sheet 5E-064. 4 Power rated at maximum VSWR. 7

Exemplary Performance Data for Model MT985AL01 1.85mm Automated Tuners VSWR versus Frequency for MT985AL01 automated tuners. Repeatability for MT985AL01 automated tuners. MT985 AL01 U.S. Patent No. 8,823,392 International Patents Pending Specifications Frequency Range -- 8.0 to 65.0 GHz VSWR Matching Range Minimum -- 10:1 Typical -- 20:1 1 Step Size (Probes) -- 31 microinches 2 Step Size (Carriage) -- 50 microinches 2 Connectors -- Precision 1.85mm, M/F 3 Power Capability -- 10W CW; 100W PEP 4 Vector Repeatability (Min.) -- 40 db Insertion Loss (probes fully retracted) -- 1.15 db 1 Defined as the minimum VSWR over 70% of the frequency range. 2 Based on 1/2 stepping the drive motors. 3 Precision 1.85mm per Maury data sheet 5E-089. 4 Power rated at maximum VSWR. 8

MT983BL01 Dimensions in Inches [cm] MT984AL01 / MT985AL01 Dimensions in Inches [cm] 9 M A U R Y M W. C O M / D ATA S H E E T / 4 T- 0 5 0 G 0 4

VISIT OUR WEB STORE TO LEARN MORE ABOUT OUR PRODUCTS www.maurymw.com

CONTACT US: W / maurymw.com E / maury@maurymw.com P / +1-909-987-4715 F / +1-909-987-1112 2900 Inland Empire Blvd Ontario, CA 91764 DATA SHEET / 4T-050G04 2018 Maury Microwave Corporation. All Rights Reserved. Specifications are subject to change without notice. Maury Microwave is AS9100D & ISO 9001:2015 Certified.