Key words: Active power filters, Fault tolerant, Fault, Reliability

Similar documents
CHAPTER 5 CONTROL SYSTEM DESIGN FOR UPFC

PERMANENT magnet brushless DC motors have been

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

ISSN Vol.03,Issue.07, August-2015, Pages:

Power Quality Analysis: A Study on Off-Line UPS Based System

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

ISSN Vol.04,Issue.16, October-2016, Pages:

REDUCTION OF ZERO SEQUENCE VOLTAGE USING MULTILEVEL INVERTER FED OPEN-END WINDING INDUCTION MOTOR DRIVE

World Journal of Engineering Research and Technology WJERT

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Journal of Engineering Technology

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Phase Shift Modulation of a Single Dc Source Cascaded H-Bridge Multilevel Inverter for Capacitor Voltage Regulation with Equal Power Distribution

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

A New Modular Marx Derived Multilevel Converter

Inductor Current Based Fault Diagnostic System for Four Port DC/DC Converter

A New Control Method for Series Active Filter in Distribution System using Unit Vector Control

Review on Shunt Active Power Filter for Three Phase Four Wire System

Simulation Study of PWM Techniques for Voltage Source Converters

An Advanced Multilevel Inverter with Reduced Switches using Series Connection of Sub Multilevel Inverters

A Novel Multilevel Inverter Employing Additive and Subtractive Topology

Reactive power compensation for linear and non linear loads by using active and passive filter for smart grid applications.

Control of buck-boost chopper type AC voltage regulator

Modified Multilevel Inverter Topology for Driving a Single Phase Induction Motor

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

MMC based D-STATCOM for Different Loading Conditions

An Advanced Full-Bridge Three Level DC-DC Converter with Voltage Balancing Control Technique for Wind Power Systems

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Harmonics Reduction using 4-Leg Shunt Active Power Filters

An Efficient Cascade H-Bridge Multilevel Inverter for Power Applications

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

Implementation Of Bl-Luo Converter Using FPGA

Symmetrical Multilevel Inverter with Reduced Number of switches With Level Doubling Network

A Comparative Study of Different Topologies of Multilevel Inverters

II. WORKING PRINCIPLE The block diagram depicting the working principle of the proposed topology is as given below in Fig.2.

International Journal Of Engineering And Computer Science ISSN: Volume 2 Issue 12 December, 2013 Page No Abstract

Speed Control of Induction Motor using Multilevel Inverter

AEIJST - July Vol 3 - Issue 7 ISSN A Review of Modular Multilevel Converter based STATCOM Topology

Hybrid Matrix Converter Based on Instantaneous Reactive Power Theory

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor

Comparison between Conventional and Modified Cascaded H-Bridge Multilevel Inverter-Fed Drive

SEVEN LEVEL HYBRID ACTIVE NEUTRAL POINT CLAMPED FLYING CAPACITOR INVERTER

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Mitigation of Voltage Sag, Swell and Load Hamonics by the Combined Opertation of Series APF and Solar System

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

AN EXPERIMENTAL INVESTIGATION OF PFC BLDC MOTOR DRIVE USING BRIDGELESS CUK DERIVED CONVERTER

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

Swinburne Research Bank

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

ENHANCING POWER SYSTEM STABILITY USING NEURO-FUZZY BASED UPFC

Key terms: Voltage, Phase Angle, FACTS, Multilevel Converter, Power Quality, STATCOM.

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Application of Fuzzy Logic Controller in Shunt Active Power Filter

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

A Modified Single-Phase Quasi z source converter

MODELING AND SIMULATION OF UNIFIED POWER QUALITY CONDITIONER FOR POWER QUALITY IMPROVEMENT

A NEW TOPOLOGY OF CASCADED MULTILEVEL INVERTER WITH SINGLE DC SOURCE

THD Analysis for 3-Phase 5-Level Diode Clamped Multilevel Inverter Using Different PWM Techniques

ISSN: [Vakula * et al., 7(8): August, 2018] Impact Factor: 5.164

CHAPTER 1 INTRODUCTION

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique

New Inverter Topology for Independent Control of Multiple Loads

ADVANCES in NATURAL and APPLIED SCIENCES

HIGH-LEVEL MULTI-STEP INVERTER OPTIMIZATION, USING A MINIMUM NUMBER OF POWER TRANSISTORS.

High Voltage DC Transmission 2

Simulation and Experimental Implementation of Single Phase Active Power Filters for Improving Power Quality

SWITCHING FREQUENCY HARMONIC SELECTION FOR SINGLE PHASE MULTILEVEL CASCADED H-BRIDGE INVERTERS

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Hybrid 5-level inverter fed induction motor drive

A Novel Five-level Inverter topology Applied to Four Pole Induction Motor Drive with Single DC Link

Protection from Voltage Sags and Swells by Using FACTS Controller

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

Power Quality Improvement Using Cascaded Multilevel Statcom with Dc Voltage Control

Fault Diagnosis in H-Bridge Multilevel Inverter Drive Using Wavelet Transforms

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

FAULT DETECTION AND DIAGNOSIS OF HIGH SPEED SWITCHING DEVICES IN POWER INVERTER

CONCLUSIONS AND SUGGESTIONS FOR FUTURE WORK

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

Performance Evaluation of Multi Carrier Based PWM Techniques for Single Phase Five Level H-Bridge Type FCMLI

MATLAB/Simulink Based Model for 25 kv AC Electric Traction Drive

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

FUZZY LOGIC CONTROL BASED DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT IN DISTRIBUTION SYSTEM

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

Mitigation of voltage sag by using AC-AC PWM converter Shalini Bajpai Jabalpur Engineering College, M.P., India

B.Tech Academic Projects EEE (Simulation)

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 03 Issue: 11 Nov p-issn:

Performance of Indirectly Controlled STATCOM with IEEE 30-bus System

Key-Words: - NARX Neural Network; Nonlinear Loads; Shunt Active Power Filter; Instantaneous Reactive Power Algorithm

by a reference vector which rotates at an angular speed of ω.

CAPACITOR VOLTAGE BALANCING IN SINGLE PHASE SEVEN-LEVEL PWM INVERTER

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

Modeling and Simulation of a Novel Three-phase Multilevel Inverter with Induction Motor Drive

Transcription:

Survey of Fault Tolerant Strategies for Shunt Active Power filters N. Madhuri 1, S.R.Doradla 2, M.Surya kalavathi 3 1 Associate Professor, 2,3 Professor,Department of EEE 1 Mahatma Gandhi Institute of Technology, Hyderabad, Andhra Pradesh, India 2 Vasavi College of Engineering, Hyderabad Andhra Pradesh, India 3 JNTU College of Engineering, Hyderabad, Andhra Pradesh, India ABSTRACT: Shunt Active power filters allied in parallel with non linear load to remove the current harmonics and to compensate reactive power, which improves the stability of the power system. Fault tolerant control is the ability of the system to function in an acceptable behaviour after sustaining a fault to provide adequate reliability. In this paper we discussed various types of faults that may appear in three phase shunt active power filters. Further we also studied various fault tolerant strategies for shunt active power filters.to develop this fault tolerant model, we simulate using Matlab/Simulink to setup a model by injecting faults such as open circuit, short circuit into the system and the system performance is demonstrated in the presence of faults and also in the absence of faults. Key words: Active power filters, Fault tolerant, Fault, Reliability I. INTRODUCTION The Active power filters are used to eradicate current harmonics and control the reactive power at high voltage distribution system. It consists of two elements namely Power circuit and Control circuit. The various components of power circuit are a capacitor, DC/AC converter, Harmonic Filter and System Protection. The function of control circuit includes the generation of reference currents, gate signals, control of capacitor voltage and voltage/current measurement. The Active Power Filters are basically classified into four different configurations, such as (i) Single Phase - 2 wire (ii) Three phase - 3 wire (iii) Three phase - 3 wire with zig-zag transformers (iv) Three phase - 4 wire. For low power applications, APF with configurations (i) and (ii) are useful. Whereas Medium and High power applications, configuration (iii) and (iv) are applied respectively [1-5]. Fault tolerant control system is the ability to sustain system performance and stability conditions in the occurrence of component failures. Most of the conventional control systems are designed for fault free systems without taking into account the possibility of fault occurrence. To overcome these drawbacks modern controllers are developed with accommodation and tolerant capabilities to provide reliability and performance requirement. Fault tolerant control system is the ability to sustain system performance and stability conditions in the occurrence of component failures. Most of the conventional control systems are designed for fault free systems without taking into account the possibility of fault occurrence. To overcome these drawbacks modern controllers are developed with accommodation and tolerant capabilities to provide reliability and performance requirement. The motivation towards FTC is to enhance reliability and safety of critical applications such as flight control and nuclear power plant operation. [6] The faults that can occur in the following three possible sub-components of active power filter such as (i) Inverter (ii) Connectors and wires (iii) Control and estimation of current reference. The various faults noticed in the inverter are [15] International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 25 Page

Short circuit of capacitor to ground Damage of a switch-open circuit Damage of switch-short circuit Line to line short circuit on ac side of inverter Short circuit of capacitor bank Two phases open in the inverter Single line to ground faults on ac side of inverter Fault diagnosis is an effective approach to enhance the reliability of power electronics systems. It consists of two phases, i.e., fault detection and fault identification. Well-timed detection of fault and system protection may avoid fault propagation and cataclysmic results. The methods of fault diagnosis in power electronic systems are classified into two categories namely (i) The methods based on converter terminal parameters i.e., current/ voltage at the terminals [7] (ii) The methods based on voltages / currents of devices. [7] Fault Diagnosis mechanism based on converter Terminal parameters: The idea is that characteristics of the input/output voltage or current of the converter are different from the one under faulty conditions. The current or voltage of converter are sensed and compared with pre-defined performance metrics to determine where the fault has occurred and identify faulty component and type of fault. The reliability and stability of the system depends on the criteria used may differentiate all possible healthy states from faulty state. This scheme uses input/ output voltages and current data rather than power device states. Thus this scheme belongs to indirect detection method with low cost. Fault Diagnosis mechanism based on voltage/ current of devices: The principle involved in this method is that the current and voltage of power switches cannot follow gate driver signals from the controller when they are short circuited or open circuited. The controller needs to supervise these current and voltage parameters. The techniques based on voltage and current information of device characteristic will provide accuracy, high speed response and reliability. On the other hand many numbers of sensors are needed because controller needs nearly all voltage and current signals of each device. Hence the associated hardware and additional cost are the main disadvantages even though with developed integrated smart driver technology will alleviate the problem. Conversely, the direct monitoring of voltage and current signals of devices provides reliable solution to error identification with significant requisite. The rest of the paper is organized as follows. In Section II, we outline the System model and Notation used in this work. Section III, we briefly discuses the architecture of fault tolerant control of Active power filters. Section IV we discuss the fault tolerant strategies of active power filter. Our Simulation results are presented in section V. Finally we conclude in section VI. II. SYSTEM MODEL AND NOTATION USED Traditional three leg shunt active power filter configuration is shown in the below Fig. 1. The power grid constitutes three phase source having source resistance R s per phase and inductance L s per phase, non-linear load and voltage fed inverter. The non linear load consists of parallel combination of three phase diode rectifier feeding series R,L load. The Voltage fed inverter has filter resistance R f per phase, filter inductance L f per phase. International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 26 Page

Fig.1 Three phase shunt active power filter configuration III. ARCHITECTURE OF FAULT TOLERANT ACTIVE POWER FILTERS Architecture of FTC is shown in Fig. 2. It consists of four components namely, Controller, APF system with fault, Fault detection and isolation component and Reconfiguration component. The APF is subjected to a fault. The FDI identifies the fault and reconfiguration component adjusts the controller to the faulty state. Fig.2. Architecture of fault tolerant Control of APF system IV. FAULT TOLERANT STRATEGIES OF ACTIVE POWER FILTER In this paper, we study two fault tolerant strategies of shunt active power filters namely (i) three leg fault tolerant strategy and (ii) Four leg fault tolerant strategy. The three leg fault tolerant strategy consists of fast fuses and three pairs of thyristors. In this strategy when subjected to fault, it leads to two leg configuration with faulty phase is connected to the middle point P of capacitors as shown in Fig 3. Fig 3. Fault Tolerant Three leg Shunt Active Power Filter configuration Whereas the four leg fault tolerant strategy of shunt active power filter consists of fast fuses, three pairs of thyristors and redundant leg. When this configuration is subjected to fault, leads to three leg structures with faulty phase connected to fourth leg, which is based on hardware redundancy gives the original structure shown in Fig.3. The above mentioned post fault configuration is Shown in Fig. 4. The reconfigured configuration under post-fault condition is shown in Fig.5 International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 27 Page

Fig.4 Fault tolerant four leg shunt active power filter configuration Fig.5 Reconfigured active power filter with fault in first leg V. SIMULATION SETUP AND RESULTS Simulation Setups: In this section we present our simulation results obtained using MATLAB/SIMULINK simulator for the four leg configuration discussed.. Simulation Results: Fault tolerant Shunt Active Power Filter configuration Fault tolerant shunt active power filter system uses to remove the harmonics and reactive power compensation. Simulation results are obtained for three phase shunt active power filter configuration in the fault free case and in the presence of fault. Below Figure Fig.6 shows the wave forms of source voltage, source current, filter current, load current for the following three cases (a) shunt active power filter configuration without fault (b) shunt active power filter configuration with fault (c) fault tolerant shunt active power filter configuration. It is observed that the total harmonic distortion is reduced for the Fault Tolerant Shunt active power filter in comparison with shunt active power filter in the presence of fault. International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 28 Page

Fig. 6 source voltage, current, filter current and load current waveforms for (a) without fault, (b) with fault (c) fault tolerant of shunt active power filters VI. CONCLUSIONS In this paper, we have studied two fault-tolerant operations of active power filters, initially focused on natural redundancy switching state combination i.e. with inverter is to operate with two phase output and next with additional components i.e., four leg topology of inverter to realize fault tolerance for all types of fault (open circuit and short circuit). It is observed that the new topology with redundancy, increase the complexity and cost of systems and even with improved performance. The more effective component level redundant design for power electronic systems should be studied further. REFERENCES [1] Fujita H, Single active filter using an H-Bridge PWM converte with a sampling frequency quadruple of switching frequency, Power Electronics, IEEE transactions, 24: 934-941,2009 [2] Luo A, Shuai Z, Shen Z J, Wenji Z, Xianyong X, design considerations for maintaining Dc Side voltage of hybrid filter with injection circuit, Power Electronics, IEEE transactions, 24: 75-84, 2009 [3] Jou H.L, Wu K.D, Wu J.C, Chiang W., A Three phase four wire power filter comprising a three phase three wire active power filter and a zig-zag transformer, Power electronics, IEEE Transactions, 23, 252-259, 2008 [4] Vodyakho O, Kim T, Shunt active filter based on three level inverter for three phase 4 wire systems, Power Electronics, IET, 2: 216-226, 2009 [5] Habrouk E, Darwish M, Mehta M.K, Active power filters: A review, Electric power applications, IEEE Proceedings, 147: 403-413 [6] P.Poure, P.Weber, D.Theilliol, S.Saadate, Fault Tolerant Control of a three phase three wire shunt active filter system based on reliability analysis. Electric Power systems Research 79(2009) 325-334. [7] Yantao Song and Bingsen Wang, Senior memberieee Survey on Reliability of power electronic systems IEEE transactions on power electronics, vol.28, No.1, 2013 [8] Ribeiro RLA, Profumo F, Jacobina, CB, Griva.G Two fault tolerant control strategies for shunt active power filter systems, IECON, 2002, vol.1, pp.792-797 [9] Jacobina.C.B, Correa M.B.R, Pinheiro R.F, Lima, A.M.N, Improved fault tolerance of active power filter system Power Electronics Specialists conference, 2001, vol.3, pp.1635-1640 [10] Poure.P, Weber.P, Theilliol.d, Saadate.S, Fault-tolerant Power Electronic Converters: Reliability Analysis of Active Power Filter Industrial Electronics, 2007, pp.3174-3179 [11] Lopes P.F, Mendes, A.M.S, Fault tolerance in active power filters, based on multilevel NPC topology, IECON-2012, oct 12, pp.410-415. [12] C.B. Jacobina, M.B. de R. Correa;, R.F. Pinheiro;, A.M.N. Lima and E.R.C. da Silva, Improved Fault Tolerance of Active Power Filter System, Power Electronics specialists conference, 2001, vol.3, pp.1635-1640. [13] Zhengyi Jiang, Xianghua Liu, Sihai Jiao and Jingtao Han, Control Strategy for Fault-Tolerant Paralleling Active Power Filter, Advanced Materials Research, 2013, vol.655-657, pp.1566-1570 International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 29 Page

[14] T. Benslimane University of Boumerdes, Algeria, Open Switch Faults Detection and Localization Algorithm for Three Phases Shunt Active Power Filter based on Two Level Voltage Source Inverter, Journal of EEE,2009, vol.9, 841-851. [15] RLA Ribero, C.B.Jacobina,ERC Da Silva, A.M.N. Lima, Fault detection of open switch damage in voltage fed PWM Motor Drive System, IEEE Transactions on Power Electronics vol.18, No.2, March 2003, pp 587-593. International Conference on Advances in Engineering & Technology 2014 (ICAET-2014) 30 Page