Sonicont USG. Ultrasonic filling level transmitter Non-contact measurement of filling levels in liquids, pastes and coarse bulk materials

Similar documents
prosonic T FMU230, FMU231

Magnetic Inductive Flow Sensor induq

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Level Measurement. GDSL Series. Ultrasonic Level Sensor

FMG90 Series Electromagnetic Flow Meter

Hydrocont S50. Hydrostatic filling level transmitter Measurement of filling levels in liquids. Main features

d = c 10/20/2017 Level Measurement Transmitters Applying Level Measurement p C T 273K Ultrasonic The Principle Time of Flight (TOF)

Magnetic Inductive Flow Sensor

Ultrasonic level measuring device, non-contact

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

OEM radar transmitter, for aggressive media level measurement

FMG70B Series Magnetic Inductive Flow Sensor

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

ULTRASONIC LEVEL METERS ULM 53

Ultrasonic Level Transmitters (Optional Exercise)

Technical Information Smartec CLD18

ULTRASONIC LEVEL METERS LU 55 INSTRUCTION MANUAL

Ult r a s o n i c le v e l me t e r s ULM 55

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

Capacitive sensors. Versatile, contactless, durable Edition 2012/2013

Installation Instructions RF-identification system Read/write head ANT513

Capacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

Operation. LEVEL Transmitters

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Float Switches with Permanent Magnet For Vertical Installation Model RSM

LST400 Ultrasonic level / open channel flow transmitter

Ultrasonic level meters ULM 70

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes

OPTIFLUX 5000 Technical Datasheet

Ultrasonic level transmitter, non-contact

Installation and maintenance manual. LSU 100, Ultrasonic level transmitter

Ultrasonic level transmitter Series LU Instructions Manual

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Operating Manual. Differential Pressure Transmitter DPS 100

Ult r a s o n i c le v e l me t e r s ULM 70

WATERFLUX 3000 Quick Start

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

ProGap Microwave barrier

Technical Information Smartec CLD18

Differential-Hall-Effect based Sensors for Detection of Speed and Direction of Rotation with two phase-shifted speed signals Series A5S0DD4 / A5S0DS4

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Inductive conductivity transmitter JUMO CTI-Junior

Technical Information Smartec CLD18

Micropilot M FMR250. Technical Information

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

OPTIFLUX 5000 Technical Datasheet

LPU-2127 User Manual

Proximity Sensors Ultrasonic Precision Proximity Sensors

INLINE flowmeter for continuous flow measurement

Page Type Resolution (mm) min. max. Output

Measuring and Controlling Unit Multronic OC

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Wind Transmitter - with frequency output xx.xxx

ATD AMP Variable Speed Reciprocating Saw Owner s Manual

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

Installation Instructions RF identification system Read/write head ANT430 ANT431

High-quality pressure transmitter For general industrial applications Model S-20

Basics of continuous level measurements. By Gene Henry, Level Product Marketing Manager, Endress+Hauser. d = c 2

INLINE flowmeter for continuous flow measurement

B Operating Instructions V1.00/EN/

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Measuring and Controlling Unit Multronic

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Level Measurement With REFLEX RADAR

Ultrasonic level indicator type INOWAFE

REFLEX RADAR INDICATOR

Ultrasonic level meters ULM 53

ULTRASONIC LEVEL METERS ULM 70

Wind Transmitter First Class

Digital flowmeter for continuous flow measurement

Level Measurement With REFLEX RADAR

Optical laser distance sensors. Dimensioned drawing

SUNSTAR 传感与控制

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

Differential-Hall-Effect based Sensors Ex ia for Detection of Speed and Direction of Rotation in Hazardous Areas Zone 0 or 1 Series A5S1DD3 / A5S1DS3

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

SITRANS LR 300: High Performance Radar for Level Measurement

Ultrasonic level transmitter Datasheet

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Submersible pressure sensor For oils and fuels Model LF-1

MaxxFlow HTC. Product Information. Flow Measurement for Dry Bulk Solids

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

INSERTION paddle wheel flowmeter for continuous flow measurement

Pressure transmitter for general industrial applications Model A-10

OPERATING MANUAL. ba77044e01 03/2014 FDO 1100 IDS OPTICAL D.O. SENSOR

Operating Instructions

Product information. Guided Wave Radar. Level and interface measurement in liquids VEGAFLEX 81 VEGAFLEX 83 VEGAFLEX 86. Document ID: 46597

Wind Transmitter First Class Advanced Classified according to IEC ( )

Xperience The Future in Level Measurements

BM SERIES ULTRA COMPACT ULTRASONIC LEVEL INSTRUMENTS (Compact version)

OPERATING INSTRUCTIONS

BML-S1F_-A/Q _-M _-_0-KA Magnetic Linear Encoder System. User's Guide. Magnetic Linear Encoder System BML-S1F_-A/Q _-M _-_0-KA

Transcription:

Sonicont USG Ultrasonic filling level transmitter Non-contact measurement of filling levels in liquids, pastes and coarse bulk materials Technical manual 04.14 Main features Non-contact filling level measurement Sonicont USG020 o in liquids up to 2m o in bulk materials up to 1m Sonicont USG050 o in liquids up to 5m o in bulk materials up to 2m Sonicont USG080 o in liquids up to 8m o in bulk materials up to 3,5m Sonicont USG150 o in liquids up to 15m o in bulk materials up to 7m Sonicont USG250 o in liquids up to 25m o in bulk materials up to12m Process temperature range from 40 C to +85 C Weather resistant and flood-proof (IP68) Hermetically sealed PVDF sensors for highest chemical resistance Integrated temperature sensor for time-of-flight correction For connection to the transmitter Sonicont USF Can be installed up to 300 m from the transmitter

You have purchased a high-grade and modern measuring device of ACS-CONTROL-SYSTEM GmbH. We want to give thanks for your purchase and for your confidence to us. The actual technical manual includes instructions for installation, electrical connection and inauguration, as well as the technical data of the device. Modifications, that answer the purpose of the technical progress, are reserved by ACS-CONTROL-SYSTEM GmbH without prior notice. If a question occurs, that can t be answered by the listed informations, please call on our technicians team in Eggenfelden Tel: +49 8721/ 9668-0 or info@acs-controlsystem.de All rights reserved 2 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de

Index Application....................................................... 4 Function......................................................... 4 Safety notes...................................................... 5 Installation....................................................... 6 Installation notes 6 Installation place 8 Electrical connection............................................... 10 Connection cable 10 Supply voltage 10 Connection scheme 10 Operation........................................................ 11 Maintenance...................................................... 12 Repair........................................................... 12 Technical Data.................................................... 13 Auxiliary power supply 13 Input 13 Output 14 Process conditions 14 Environmental conditions 14 Materials 14 Dimension drawings................................................ 15 Process connection 15 Order Code....................................................... 19 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de 3

Application The device is a non-contact electronic ultrasonic filling level sensor for continuous measuring of filling levels in liquids, pastes and coarse bulk materials. The use of a non-contact operating measuring systems opens a broad range of application possibilities like e.g. at aggressive process materials. The device is designated for the use with the transmitter Sonicont USF. Function The transducer of the ultrasonic sensor transmits ultrasonic pulses to the product surface. These pulses are reflected by product surface and received back by the transducer as echoes. The running time of the ultrasonic pulses from emission to reception is proportional to the distance and hence the level. The determined level is converted into an appropriate output signal and outputted as measured value. An integrated temperature sensor compensates changes in the velocity of sound caused by temperature changes. 4 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de

Safety notes Each person that is engaged with inauguration and operation of this device, must have read and understood this technical manual and especially the safety notes. Installation, electrical connection, inauguration and operation of the device must be made by a qualified employee according to the informations in this technical manual and the relevant standards and rules. The device may only be used within the permitted operation limits that are listed in this technical manual. Every use besides these limits as agreed can lead to serious dangers. The materials of the device must be chosen resp. checked for compatibility with the respective application requirements (contacting materials, process temperature). An unsuitable material can lead to damage, abnormal behavior or destruction of the device and to the resulting dangers. The sensors may not be used as sole device for prevention of dangerous conditions in machines and plants. This measuring device meets article 3 (3) of the EC directive 97/23/EC (pressure equipment device directive) and is designed and produced in good engineer practice. The device meets the legal requirements of all relevant EC directives. Using the device in a manner that does not fall within the scope of its intended use, disregarding this instruction, using under-qualified personnel, or making unauthorized alterations releases the manufacturer from liability for any resulting damage. This renders the manufacturer s warranty null and void. ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de 5

Installation The correct function of the device within the specific technical data can only be guaranteed, if the permitted process and environmental temperatures (see chapter Technical data ) will not be exceeded. Installation notes Drive the system pressure free prior installation resp. deinstallation of the sensor. The screw-in of the thread process connection by using the connection cable is not permitted. The installation can be made by the front thread as well as by the rear thread. Pressure / vacuum Gauge pressure in the vessel does not influence the measuring result. Low pressure or vacuum does, however, damp the ultrasonic pulses. This influences the measuring result, particularly if the level is very low ( -0,2 bar resp. -20 kpa). Vapor pressure The vapor pressure at 20 C (68 F) gives a hint on the accuracy of the ultrasonic level measurement. If the vapor pressure at 20 C (68 F) is below 50 mbar, ultrasonic level measurement is possible with a very high accuracy. This is valid for water, aqueous solutions, water-solid-solutions, dilute acids (e.g. hydrochloric acid, sulfuric acid), dilute bases (e.g. caustic soda), oils, greases, slurries, pastes, etc. High vapor pressures or outgassing media (e.g. ethanol, acetone, ammonia) can influence the accuracy. Range The sensor range is dependent on the measuring conditions. The maximum range can be found in the chapter Technical Data - Input. Blocking distance Install the device at a height so that the blocking distance BD (see chapter Technical Data - Input ) is not undershot, even at maximum fill level. If the blocking distance is undershot, it may cause device malfunction. If the medium reaches the transducer, buildup can form on it and cause faulty measurements later on. 6 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de

Nozzle installation Use a pipe nozzle if you cannot maintain the blocking distance in any other way. The interior of the nozzle must be smooth and may not contain any edges or welded joints. In particular, there should be no burr on the inside of the tank side nozzle end. Note the specified limits for nozzle diameter and length. To minimize disturbing factors, we recommend an angled socket edge (ideally 45 ). Nozzle diameter D DN50 / 2 DN80 / 3 DN100 / 4 DN150 / 6 Maximum nozzle length L 80 mm 240 mm 300 mm 400 mm Standpipe measurement By using a standpipe (surge or bypass tube), the influence of vessel installations, foam generation and turbulence is excluded. Standpipes must extend all the way down to the requested min. level, as measurement is only possible within the tube. The pipe must be provided with a sufficient venting hole (A) (Ø 5 10mm) at the upper edge. Avoid large gaps and thick welding joints when connecting the tubes. Measurement in a standpipe is not recommended for very adhesive products. ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de 7

Installation place Level measurement o Do not install the sensor in the middle of the tank (C). We recommend leaving a distance between the sensor and the tank wall (A) measuring 1/6 of the tank diameter. In vessels with conical bottom it can be advantageous to mount the sensor in the center of the vessel, as measurement is then possible down to the lowest point of the vessel bottom. o Use a protective cover, in order to protect the device from direct sun or rain (B). o Avoid measurements through the filling curtain (D). Through the action of filling, stirring and other processes in the vessel, dense foams which considerably damp the emitted signals may form on the product surface. If foams are causing measurement errors, the sensor should be used in a standpipe. o If there are strong air currents in the vessel, e.g. due to strong winds in outdoor installations or air turbulence, e.g. by cyclone extraction, the device should be mount in a standpipe. o Make sure that equipment (E) such as limit switches, temperature sensors, etc. are not located within the emitting angle α. In particular, symmetrical equipment (F) such as heating coils, baffles etc. can influence measurement. If large vessel installations such as struts or supports cause false echoes, these can be attenuated through supplementary measures. Small, inclined sheet metal or plastic baffles above the installations scatter the ultrasonic signals and avoid direct false echoes. o Align the sensor so that it is vertical to the product surface (G). o Never install two ultrasonic measuring devices in a tank, as the two signals may affect each other. o To estimate the detection range, use the 3 db emitting angle α, that can be found in the chapter Technical Data - Input. This radius of the detection range at an arbitrary distance Lx can be calculated by the following term: = tan (α / 2) * L x Example values for L x and can be found in the chapter Technical Data - Input. 8 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de

Installation in narrow shafts In narrow shafts with strong interference echoes, we recommend using a stand pipe resp. an ultrasound guide pipe (e.g. PE or PVC wastewater pipe) with a minimum diameter of 100 mm. Make sure that the pipe is not soiled by accumulated dirt. If necessary, clean the pipe at regular intervals. The pipe must be provided with a sufficient venting hole (A) (Ø 5 10mm) at the upper edge. Flow measurement o Install the device at the inflow side, as close above the maximum water level H max as possible (take into account the blocking distance BD). o Position the device in the middle of the channel or weir. o Align the sensor membrane parallel to the water surface. o Keep to the installation distance of the channel or weir. Example: Triangular weir ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de 9

Electrical connection The electrical connection of the device must be carried out according to the respective country specific standards. Incorrect installation or adjustment could cause applicationally conditioned risks. The device is only designated for the connection to the transmitter Sonicont USF. Connection cable In order to avoid interference signals, the connection cable should not be laid parallel to high voltage electric power lines. The cable may not be laid in the proximity to frequency converters. The shield of the connection cable must be connected to the terminal PE/PA of the transmitter Sonicont USF. If required, the sensor cable can be shortened. o Do not damage the cores when removing the insulation. o The cable is shielded by a metallic braiding. After shortening the cable, loosen the metallic braiding, twist it together securely and connect it to the terminal PE/PA of the transmitter. o A conductor (GNYE), which is present but not used in the connection cable may not be electrically connected. Supply voltage The device is supplied by the transmitter Sonicont USF. Connection scheme See technical manual Sonicont USF. 10 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de

Operation An operation provided by user is not designated. ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de 11

Maintenance The device is free of maintenance. Special substances can lead to solid coatings on the membrane. Seized depositions can lead to faulty measurement results. In the case of coat forming liquids the membrane must be regularly cleaned e.g. with clear water. Don t use sharp tools or aggressive chemicals for cleaning. Repair A repair may only be carried out by the manufacturer. If the device must be sent back for repair, the following informations must be enclosed: An exact description of the application. The chemical and physical characteristics of the product. A short description of the occurred error. Before returning the device for repair, the following measures must be proceeded: All adhesive product residues must be removed. This is especially important, if the product is unhealthily, e.g. caustic, toxic, carcinogenic, radioactive etc. A returning must be refrained, if it is not possible by 100% to remove the unhealthily product completely, because e.g. it is penetrate into cracks or is diffused through plastic. 12 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de

Technical Data Auxiliary power supply Supply voltage U S Supplied by transmitter Sonicont USF Input Measuring range Type 020 Liquids / Bulk materials 2m / 1m Type 050 Liquids / Bulk materials 5m / 2m Type 080 Liquids / Bulk materials 8m / 3,5m Type 150 Liquids / Bulk materials 15m / 7m Type 250 Liquids / Bulk materials 25m / 12m Blocking distance BD Type 020 0,15m (typ. 0,06m) Type 050 Type 080 Type 150 Type 250 0,20m (typ. 0,15m) 0,30m (typ. 0,19m) 0,40m (typ. 0,35m) 0,60m (typ. 0,46m) Operating frequency Type 020 125kHz Type 050 Type 080 Type 150 Type 250 50kHz 75kHz 41kHz 30kHz Emitting angle α Type 020 10 ±2 at -3 db Type 050 14 ±2 at -3 db Type 080 10 ±2 at -3 db Type 150 14 ±2 at -3 db Type 250 12 ±2 at -3 db Detection radius Type 020 = 0,044m (L x = 0,5m / α = 10 ) = 0,087m (L x = 1,0m / α = 10 ) = 0,131m (L x = 1,5m / α = 10 ) = 0,175m (L x = 2,0m / α = 10 ) Type 050 = 0,153m (L x = 1,25m / α = 14 ) = 0,307m (L x = 2,5m / α = 14 ) = 0,460m (L x = 3,75m / α = 14 ) = 0,614m (L x = 5,0m / α = 14 ) Type 080 = 0,175m (L x = 2,0m / α = 10 ) = 0,491m (L x = 4,0m / α = 10 ) = 0,525m (L x = 6,0m / α = 10 ) = 0,700m (L x = 8,0m / α = 10 ) Type 150 = 0,460m (L x = 3,75m / α = 14 ) = 0,921m (L x = 7,5m / α = 14 ) = 1,381m (L x = 11,25m / α = 14 ) = 1,842m (L x = 15,0m / α = 14 ) Type 250 = 0,657m (L x = 6,25m / α = 12 ) = 1,314m (L x = 12,5m / α = 12 ) = 1,971m (L x = 18,75m / α = 12 ) = 2,628m (L x = 25,0m / α = 12 ) ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de 13

Pulse rate t p (measure cycle time) Type 020 5Hz (200ms) / 2,5Hz (400ms) / 1,25Hz (800ms) Type 050 2,5Hz (400ms) / 1,25Hz (800ms) / 0,625Hz (1600ms) Type 080 1,667Hz (500ms) / 0,833Hz (1000ms) / 0,417Hz (2000ms) Type 150 1,667Hz (500ms) / 0,833Hz (1000ms) / 0,417Hz (2000ms) Type 250 1,667Hz (500ms) / 0,833Hz (1000ms) / 0,417Hz (2000ms) Output Distance Signal Analogue voltage / pulse signal Temperature Signal Resistance NTC 10 kω Process conditions Process temperature Process pressure -40 C +85 C -0,3 2 bar Environmental conditions Environmental temperature -40 C...+85 C Protection IP68 [ 1 mws-1h] (EN/IEC 60529) Climatic classification 4K4H [-20 +55 C / 4 100%] (EN/IEC 60721-3-4) Shock classification 15 g [11ms] (EN/IEC 60068-2-27) Vibration classification 4 g [10-500 Hz] (EN/IEC 60068-2-6) EM compatibility Operation device class B / Industrial range (EN/IEC 61326) Weight Type USG020 0,5 kg + (L1 x 0,075 kg/m) Type USG050 0,5 kg + (L1 x 0,075 kg/m) Type USG080 0,6 kg + (L1 x 0,075 kg/m) Type USG150 0,7 kg + (L1 x 0,075 kg/m) Type USG250 0,9 kg + (L1 x 0,075 kg/m) Materials process wetted Sensor Process connection PVDF USG020 / USG050 / USG080 / USG150 PVDF USG250 PVDF / PBT Valox not process wetted Sensor rear side Connection cable PE PUR 14 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de

Dimension drawings Process connection Type 020 G15 - G 1½ ISO 228-1 Type 050 G15 - G 1½ ISO 228-1 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de 15

Type 080 G20 - G 2 ISO 228-1 16 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de

Type 150 M32 M32x1,5 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de 17

Type 250 M32 M32x1,5 18 ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de

Order Code Type 020 Measuring range 2m/1m 050 Measuring range 5m/2m 080 Measuring range 8m/3,5m 150 Measuring range 15/7m 250 Measuring range 25/12m Admission 0 Standard X ATEX II 1 G / ATEX II 1 D (in preparation) Process connection G15 G 1½, ISO 228-1 / M32x1,5 G20 G 2, ISO 228-1 / M32x1,5 M32 M32x1,5 USG020 / USG050 USG080 USG150 / USG250 0 0 P Material process connection (process wetted) PVDF (USG250 >> PVDF / PBT Valox) 0 B Electrical connection Connection cable PUR Length L1 connection cable 1 5m 2 10m 3 15m 4 20m 5 25m 6 30m 0 Standard Sonicont USG 0 0 P 0 B 0 Installation material and connection cable are not enclosed in contents of delivery. ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l info@acs-controlsystem.de 19