SIMULTANEOUS XRD/XRF WITH LOW-POWER X-RAY TUBES

Similar documents
USING A CHARGE-COUPLED DEVICE (CCD) TO GATHER X-RAY FLUORESCENCE (XRF)AND X-RAY DIFFRACTION (XRD) INFORMATION SIMULTANEOUSLY

MOXTEK S NEW ULTRA-LITE X-RAY SOURCES: PERFORMACE CHARACTERIZATIONS

MINIATURE X-RAY SOURCES AND THE EFFECTS OF SPOT SIZE ON SYSTEM PERFORMANCE

ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER

MICRO XRF OF LIGHT ELEMENTS USING A POLYCAPILLARY LENS AND AN ULTRA THIN WINDOW SILICON DRIFT DETECTOR INSIDE A VACUUM CHAMBER

X-RAY OPTICS FOR TWO-DIMENSIONAL DIFFRACTION

DEVELOPMENT OF A WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER USING A MULTI-CAPILLARY X-RAY LENS FOR X-RAY DETECTION

X-Ray Spectroscopy with a CCD Detector. Application Note

WIDE ANGLE GEOMETRY EDXRF SPECTROMETERS WITH SECONDARY TARGET AND DIRECT EXCITATION MODES

DESIGN AND MEASUREMENT WITH A NEW PORTABLE X-RAY CAMERA FOR FULL-FIELD FLUORESCENCE IMAGING

DOUBLE MULTILAYER MONOCHROMATOR WITH FIXED EXIT GEOMETRY. H.Gatterbauer, P.Wobrauschek, F.Hegediis, P.Biini, C.Streli

MINIATURE X-RAY TUBES UTILIZING CARBON-NANOTUBE- BASED COLD CATHODES

Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror

CARBON-NANOTUBE FIELD EMISSION X-RAY TUBE FOR SPACE EXPLORATION XRD/XRF INSTRUMENT.

X-RAY BACKSCATTER IMAGING: PHOTOGRAPHY THROUGH BARRIERS

RIETVELD REFINEMENT OF POWDER DATA FROM MULTILAYER OPTICS

LONG TERM STATISTICS OF X-RAY SPECTROMETERS

Copyright -International Centre for Diffraction Data 2010 ISSN

Author s Accepted Manuscript

GUNSHOT RESIDUE INVESTIGATIONS USING TXRF

MICROANALYSIS WITH A POLYCAPILLARY IN A VACUUM CHAMBER

A PORTABLE NON-INVASIVE XRD-XRF INSTRUMENT FOR THE STUDY OF ART OBJECTS.

A PORTABLE X-RAY APPARATUS FOR BOTH STRESS MEASUREMENT AND PHASE ANALYSIS UNDER FIELD CONDITIONS.

TOWARDS SUB-100 NM X-RAY MICROSCOPY FOR TOMOGRAPHIC APPLICATIONS

Lesson 2 Diffractometers

MOXTEK. 50kV 10 Watt MAGNUM X-ray Source. X-ray Sources. Contents

RIGAKU VariMax Dual Part 0 Startup & Shutdown Manual

X-ray investigation of crystal structures / Laue method with digital X-ray detector (XRIS) (Item No.: P )

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

MICROFOCUSING X-RAY EQUIPMENT FOR THE LAB DIFFRACTOMETER

OPTIMIZING THE ELEMENTAL SENSITIVITY AND FOCAL SPOT SIZE OF A MONOLITHIC POLYCAPILLARY OPTIC USING MICRO-X-RAY FLUORESCENCE

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

(12) Patent Application Publication (10) Pub. No.: US 2007/ A1

Development of X-ray Tool For Critical- Dimension Metrology

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

Applications of Micro XRF for the Analysis of Traditional Japanese "Ainu" Glass Beads and other Artifacts

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

photolithographic techniques (1). Molybdenum electrodes (50 nm thick) are deposited by

TOWARDS FAST RECIPROCAL SPACE MAPPING

Using Carbon Nano-Tube Field Emitters to Miniaturize X-Ray Tubes

ARTAX. Innovation with Integrity. Portable Micro-XRF Spectrometer. Micro-XRF

Advancing EDS Analysis in the SEM Quantitative XRF. International Microscopy Congress, September 5 th, Outline

By using patented polycapillary optics this diffractometer obviates the need for monochromators and collimators for linear projection of X-Rays.

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

Improving the Collection Efficiency of Raman Scattering

Initial Results from a Cryogenic Proton Irradiation of a p-channel CCD

Spectral distribution from end window X-ray tubes

High Rep-Rate KrF Laser Development and Intense Pulse Interaction Experiments for IFE*

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Data Collection with. VÅNTEC-2000 Detector

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

LECTURE 10. Dr. Teresa D. Golden University of North Texas Department of Chemistry

CONFOCAL GRADED d-spacing MULTILAYER BEAM CONDITIONING OPTICS

DESIGN NOTE: DIFFRACTION EFFECTS

M4 TORNADO PLUS. Innovation with Integrity. Super Light Element Micro-XRF Spectrometer. Micro-XRF

Water-Window Microscope Based on Nitrogen Plasma Capillary Discharge Source

Miniflex. Rigaku/ Miniflex X-ray Diffractometer System. Rigaku Corporation

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

The SS6000 Gold Mate Series For analyzing all precious metals and other elements from Mg to U

Zaidi Embong and Husin Wagiran Physics Department, University Of Technology Malaysia, P.O Box 791, 80990, Johor Baharu

Single Photon Interference Katelynn Sharma and Garrett West University of Rochester, Institute of Optics, 275 Hutchison Rd. Rochester, NY 14627

Scanning electron microscope

ADAPTIVE CORRECTION FOR ACOUSTIC IMAGING IN DIFFICULT MATERIALS

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

BRUKER ADVANCED X-RAY SOLUTIONS. SPECTROMETRY SOLUTIONS ARTAX mxrf SPECTROMETER

ABSTRACT. Supported by U.S. DoE grant No. DE-FG02-96ER54375

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Leica TCS SP8 Quick Start Guide

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Basic P-XRD instructions for Operating the Instrument

research papers First results from a macromolecular crystallography system with a polycapillary collimating optic and a microfocus X-ray generator

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

A Framed Monochromatic X-Ray Microscope for ICF

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

Test procedures Page: 1 of 5

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

3D light microscopy techniques

Low Cost Rolled X-ray Prism Lenses to Increase Photon Flux Density in Diffractometry Experiments

Measurements of MeV Photon Flashes in Petawatt Laser Experiments

Laser Scanning for Surface Analysis of Transparent Samples - An Experimental Feasibility Study

Possibilities for Thick, Simple- Structure Silicon X-Ray Detectors Operated by Peltier Cooling

Preliminary Comparison of Monolithic and Aperture Optics for XRMF. George J. Havrilla CST-8 Christopher G. Worley CST-8

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

R-AXIS RAPID. X-ray Single Crystal Structure Analysis System. Product Information

University of Wisconsin Chemistry 524 Spectroscopic Components *

Polycapillary optic source combinations for protein crystallography

Introduction to X-ray Detectors for Synchrotron Radiation Applications

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

2. Refraction and Reflection

Supplementary Information

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

Indiana University JEM-3200FS

Instructions XRD. 1 Choose your setup , Sami Suihkonen. General issues

Instrument Description

Transcription:

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 34 SIMULTANEOUS XRD/XRF WITH LOW-POWER X-RAY TUBES S. Cornaby 1, A. Reyes-Mena 1, P. W. Moody 1, T. Hughes 2, A. Stradling 2, T. Grow 1, and L. V. Knight 2 1 MOXTEK, Inc., 452 West 1260 North, Orem, UT 84057 2 Department of Physics and Astronomy, Brigham Young University, Provo, UT 84602 ABSTRACT A test bench instrument constructed at MOXTEK, Inc. is capable of simultaneously capturing X-ray diffraction (XRD) and X-ray fluorescence (XRF) information using a charge-coupled device (CCD) as the X-ray detector. NASA is funding the instrument s construction because of its low-power consumption and compact size; it could be used for in-situ planetary exploration missions for mineral analysis. A powdered sample of material is placed in front of the CCD. A collimated X-ray beam bombards the sample, and the CCD captures the scattered X-ray events. Sorting algorithms are used to separate the XRF and the XRD information captured by the CCD. A small low-power X-ray source is needed to make the device portable. We have examined the instrument with a rotating-anode tube, a commercially available Svetlana transmission tube, and two miniature low-power prototype tubes constructed at MOXTEK. The data capturing rates were compared for the different sources. We have verified the feasibility of capturing both XRF and XRD with the MOXTEK source, using under five watts for both the tube and its high-voltage power supply. INTRODUCTION A first prototype XRD/XRF instrument was developed at NASA Ames Research Center and is currently in use at Los Alamos National Laboratory [1,2]. The intended applications for this instrument are for planetary exploration and as a portable instrument for terrestrial use. The planetary missions have used methods that give elemental composition, such as the Mars Pathfinder probe that used XRF. XRF gives the elemental composition and suggests certain minerals, but the traditional method of mineral identification is by XRD [3]. With a small, portable XRD/XRF instrument, both diffraction and fluorescence information can be simultaneously gathered, providing accurate mineral identification. The purpose of the test bench setup constructed at MOXTEK is to incorporate and test the low-power X-ray tube in an XRD/XRF instrument design. Initially we tested the CCD detector for X-ray detection and developed algorithms for sorting the data. For the initial setup we used a Rigaku RU-200 rotating anode tube for the X-ray source. For the next stage of testing we compared data taken with a high-power rotating anode tube and three low-power sources a commercially available transmission anode tube and two MOXTEK side-window tubes. We successfully captured both XRD and XRF data with each of the X-ray sources. The information gained from the test bench will lead to a small portable prototype instrument. We will first describe instrument and the sample

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 35 preparation. We will discuss how the CCD captures the data. We will then give a description of the MOXTEK tube. Finally, we will present the test data obtained using the low-power MOXTEK tubes and the commercial sources. EXPERIMENTAL SETUP AND SAMPLE PREPARATION The components of the XRD/XRF instrument are the Charge-Coupled Device (CCD) camera, pinhole optics, sample holder and X-ray source (Fig. 1). Figure 2 is a picture of the instrument with the MOXTEK tube. A Princeton Instruments CCD camera was used to acquire data. The camera has a frontside illuminated (FSI) CCD with an active area of 8.4 mm x 12.7 mm (EEV CCD02-06 deep depletion). The X-ray tube supplies the X-rays that are either absorbed or scattered by the powder sample. The tubes that have been used are a Rigaku Rotaflex RU-200 rotating anode tube, a Svetlana Electron Device Manufacturing Corporation (St. Petersburg, Russia) tube type bc1 copper anode, and two MOXTEK Bullet TM side-window tubes. The pinhole optics are used to collimate the X-ray beam from the X-ray tube for diffraction. Pinhole sizes used range IURP PWR PDQGWKHGLVWDQFH between the pinholes used ranges from 10 mm to 60 mm. The sample holder supports the sample in the beam and has minimal X-ray scattering [4,5]. Figure 1. Concept drawing for the XRD/XRF instrument. Figure 2. Picture of the XRD/XRF bench top instrument. The samples discussed in this paper were prepared by grinding the KCl sample with a mortar and pestle into a powder. MOXTEK s AP1 films were used to support the samples because of their X-UD\WUDQVSDUHQF\$ PWR PWKLFNOD\HURIWKH powder sample adheres to the film by using a small amount of vacuum grease (silicon or graphite). Finally, the sample is placed in front of the CCD, which captures the diffracted X-rays transmitted through the sample. X-RAY DETECTION USING A CCD The CCD uses each pixel as an individual energy-dispersive detector. This allows the spatial position (XRD information) and the energy of an X-ray (XRF information) to be recorded. To obtain unambiguous energy information, each pixel must only record one

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 36 X-ray event [5]. Once all the events are recorded, the diffraction information and the fluorescent information are extracted with the use of sorting algorithms [5,6]. The major factors that affect the energy resolution of the CCD are temperature and exposure time. Cooling the CCD and shortening the exposure time increase the energy resolution. The CCD is sensitive to X-rays in the region of 1.5 kev to 12 kev. The depletion region of the CCD limits detection of energies higher than 12 kev and the gate structure on the CCD limits energy detection below 1.5 kev. With the CCD cooled to -50 C with five-second exposures the energy resolution of the CCD is 185 ev at 5.89 kev. Figure 3 shows an XRF spectrum collected with the CCD camera from a powder.&ovdpsoh,qwkhiljxuhfkorulqh. DQGSRWDVVLXP. DQG. HPLVVLRQIURPWKH VDPSOHFDQEHVHHQ$FRSSHU. GLIIUDFWLRQSHDNFDQDOVREHVHHQWKDWLVFDXVHGE\;- ray diffraction scattering. Cl K.... &X. Figure 3. The XRF spectrum from a KCl sample. Figure 4. The XRD imaga KCl sample. The angular resolution of the test bench instrument is limited by the X-ray spot size of the incident beam and the beam divergence. By using various pinhole configurations the spot size can be varied from 60 µm to 150 µm when viewed on the CCD. This provides an angular resolution of 0.4 to 0.7 FWHM in a GLIIUDFWLRQSORW. With the present configuration, resolution of the diffraction patterns may be slightly improved by using smaller pinholes, but smaller pinholes also reduce the flux of X-rays impinging upon the sample [5]. Figure 5. The XRD SORWIURPD.&O sample. The angular range of X-ray diffraction of the instrument is based primarily on the distance from the sample to the detector and the size of the CCD. The angular resolution of the instrument could be greatly improved by moving the CCD further away from the sample, but this would decrease the range of angles the CCD could observe. The range of

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 37 the X-UD\GLIIUDFWLRQSHDNVFDSWXUHGLVaƒWRaƒ LIWKHEHDPVSRWLVSODFHGLQWKH middle of the CCD X-ray window. The range of diffraction peaks can be increased to DERXWƒ LIWKHEHDPVSRWLVSODFHGDWWKHHGJHRIWKH&&'EXWXQGHUWKHVH conditions full diffraction rings will not be captured. Figure 4 shows the rings in diffraction image captured from a KCl sample. Figure 5 shows a plot generated from the image that gives the intensity of the rings as a function of angle. The characteristics of the CCD make it an excellent detector for the instrument. It is able to capture both the energy and the position of X-ray events. This allows the X-ray events to be sorted by algorithms; thus, we do not attenuate the events with filters to get the desired X-ray energy. Also, the CCD captures a large solid angle, i.e., every event within ƒ ZLOOKLWWKHGHWHFWRU)RUDORZ-power instrument this is ideal because there will be few scattered events with a low power X-ray source. The CCD allows the instrument to maximize the detection of every scattered event. LOW-POWER TUBE CHARACTERISTICS The low-power MOXTEK tubes have a grounded anode with a tungsten filament cathode. Figure 6 shows the construction of the sidewindow tube design with all major components identified. The ceramic tube body isolates the anode and the cathode and is sealed so the inside of the tube maintains a vacuum environment. The silicone potting allows the tube to operate at higher voltages by eliminating airborne arcs between the anode and the cathode on the outside of the tube. The anode and cathode optics direct and focus the electron beam onto the copper anode. Be Window Cu Anode Silicon Potting Anode Optic Cathode Optic Ceramic Tube Body Filament High-Voltage Wire Figure 6. Schematic of the copper anode MOXTEK side-window tube. The important features of the MOXTEK tube are that it is small in size and consumes very little power compared to conventional tubes. The tube is 42 mm and 15 mm in diameter (Fig. 7). The high-voltage power supply is 3x7x17 cm and requires a controller box and a 10 Volt DC input to operate. The maximum voltage is 20 kv with an emission current oi $7KHPD[LPXPLQSXWSRZHUUHTXLUHGWRUXQERWKWKHWXEHWKHKLJKvoltage power supply is five watts. For the data taken in the next section, the tube RSHUDWHGDWN9DQG $ZLWKDWRWDOSRZHUFRQVXPSWLRQRIZDWWV7KH MOXTEK tube is substantially smaller and consumes a great deal less power than the

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 38 RU-200 rotating anode tube. The rotating anode tube is rated for 60 kv, 200mA, and is housed on a large table that is 1.75x1.75x1 m. The MOXTEK tube is more compact than the Svetlana transmission-dqrghwxeh7kh6yhwodqdwxehlvudwhgirun9 $DQG is 400 mm long and 40 mm in diameter. Figure 7. Picture of MOXTEK low-power tube. For X-ray diffraction the main considerations are the characteristic emission lines and the size of the beam spot on the anode. The low-power MOXTEK tube has a copper anode so the primary excitation UDGLDWLRQZLOOEHWKHFRSSHU. emission line. Figure 8 shows Figure 8. Emission spectrum of the low-power tube. the emission spectrum measured with a Si(Li) detector with the WXEHRSHUDWLQJDWN9DQG $7KHFRSSHU. UDGLDWLRQFRQVLVWVRf 27 % of the HPLVVLRQVSHFWUXPRIWKHWXEH7KHEHDPVSRWRQWKHWXEHLVDSSUR[LPDWHO\[ (Fig. 9). Two bright lobes within the spot can be seen in the image. The threedimensional intensity profile shows the intensity distribution across the anode. Each tube we investigated with the side-window design had a similar spot size and shape. RESULTS Figure 9. Image and 3D plot of the spot on the sidewindow tube. Table 1 contains data produced by the different X-ray sources employed. The optics control the diffraction angular resolution and the flux irradiating the sample. There is a trade-off between the flux and the angular resolution. If the flux on the sample is increased the angular resolution is decreased and vice versa. In some runs we wanted to get a higher flux while in others we wanted to improve angular resolution. On each run we used a KCl sample to eliminate any variations from the sample. P

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 39 One key comparison within the table is between the Svetlana tube and the MOXTEK tube 72. The Svetlana tube was used before the MOXTEK tubes were built to test the feasibility of using a low-power X-ray source for XRD. In this comparison the optical setup and the tube emission current are exactly the same for both tubes. The differences are that the tubes have different spot sizes and that the Svetlana tube has a transmission anode while the MOXTEK tube has a reflection anode. The XRD/XRF instrument was able to collect at about four times the count rate with the MOXTEK tube over the Svetlana tube. Source RU-200 Svetlana tube MOXTEK tube72 MOXTEK tube79 tube characteristics spot size.1mmx1mm P [ P [ P tube current 30 ma $ $ $ tube voltage 30 kv 30 kv 16 kv 17.5 kv Optics pinhole size near source P P P P pinhole size near sample P P P P distance between pinholes ~9 cm ~6 cm ~6 cm 1.38 cm divergence of beam 0.13 0.24 0.24 0.25 CCD angular resolution ~0.6 ~1.3 ~1.3 ~0.5 Data count rate Cl K alpha (2.622 kev) 12.8 cps 1.5 cps 7.6 cps 4.4* cps K K alpha (3.312 kev) 18.3 cps 2.1 cps 6.4 cps 3.4* cps Cu K alpha (8.041 kev) XRD events 4.7 cps 0.33 cps 0.83 cps 0.98* cps * Contains data from both the single and split events. Table 1. A comparison of data collection rates of a KCl sample taken with different x- ray tubes and optical setups. The second key comparison within the table is between the RU-200 tube and the MOXTEK tube 79. With the high-power tube we were able to get four times the count rate, but at a cost of more than 900 watts in just the emission current alone. With the MOXTEK tube the cost in total power input was 4.4 watts. The comparison is not direct in that a different optical setup was used with each tube, but it does show that with the low-power tube we are able to get data at a comparable rate. The data capture rate can be slightly increased with better optical setups and can be greatly increased with a smaller spot on the low-power X-ray tube anode. CONCLUSION The testing setup has been successful in proving the feasibility of a compact portable XRD/XRF instrument with the potential to be used in future planetary applications and in terrestrial applications. We were able to capture XRD and XRF data using the MOXTEK tube. The total power requirements for the instrument have been minimized and, thus, a battery can supply the power required to capture X-ray diffraction and X-ray fluorescence. Future work will include maximizing the data collection rate so that enough data can be collected to do quantitative analysis in a timely manner.

Copyright (c)jcpds-international Centre for Diffraction Data 2002, Advances in X-ray Analysis, Volume 45. 40 ACKNOWLEDGMENTS NASA is supporting this work under SBIR contract number NAS2-00010. We thank Brigham Young University for student financial support and for use of equipment. REFERENCES [1] Blake D. F., et al. Design of an X-ray Diffraction/ X-ray Fluorescence Instrument for Planetary Applications, Proceedings of the Lunar and Planetary Science Conf. (1992) XXIII 117-118. [2] Blake D. F., et al. X-ray Diffraction Apparatus, 1993 U.S. Patent No. 5,491,738. [3] Vaniman D., Bish D., Blake D. F., Elliott S. T., Sarrazin P., Collins S. A., Chipera S., Landed XRD/XRF Analysis of Prime Targets in the Search for Past and Present Martian Life, J. Geophys. Res. (1998) 103(E13) 31,477-31,489. [4] Reyes-Mena A., Cornaby S., Pew H. K., Moody P. W., Hughes T., Stradling A., and Knight L. V., Using a CCD to Gather XRF and XRD Information Simultaneously, IN: Advances in X-ray Analysis, Vol. 44, Plenum, New York, (2000) (in press). [5] Cornaby S., Reyes-Mena A., Pew H. K., Moody P. W., Hughes T., Stradling A., Turner C., and Knight L. V., An XRD/XRF Instrument for the Microanalysis of Rocks and Minerals, Meas. Sci. Techno., 12 (2001) pp. 676-683. [6] Cornaby S., Reyes-Mena A., Pew H. K., Moody P. W., Hughes T., Stradling A., and Knight L. V., Using a Charged-Coupled Device (CCD) as an X-ray Single Photon Energy-Dispersive Detector, Journal of X-ray Science and Technology, 9 (2000) 1-13.