Complimentary Reference Material

Similar documents
Power Meter NRVS. Power, level and voltage measurements from DC to 40 GHz

Voltage Sensors URV5-Z

Vector Network Analyzers ZVB


R&S ZV-Z5x Calibration Units Specifications

RF Signal Generator SM300

Spectrum Analyzer R&S FS300

Handheld Spectrum Analyzer R&S FSH3

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

Handheld Spectrum Analyzer R&S FSH3

R&S FSC Spectrum Analyzer Specifications

R&S ZV-Z5x Calibration Units Specifications

Technical Information

R&S ZNB Vector Network Analyzer Specifications

R&S ZVT Vector Network Analyzer Specifications

Signal Generator SML

R&S ZNC Vector Network Analyzer Specifications

Thermal Power Sensor

Handheld Spectrum Analyzer R&S FSH 3

Modulation Analyzer FMAB

Spectrum Analyzer FSL

Technical Information

EMI Test Receivers ESHS

R&S FSH4/8 Spectrum Analyzer Specifications

R&S EB500 Monitoring Receiver Specifications

R&S ZVT Vector Network Analyzer Specifications

Complimentary Reference Material

Signal Generators SMY

R&S CBT/R&S CBT32 Bluetooth Tester Specifications

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ESCI/ESCI7 EMI Test Receiver Specifications

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer

R&S RSC Step Attenuator Specifications

Power Sensors NRV-Z. For RF and microwave power measurements

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

HZ530 Near-Field Probe Set

R&S ZN-Zxxx Calibration Units Specifications. Data Sheet V04.00

Exposure Level Tester ELT-400

khz to 2.9 GHz Spectrum Analyzer

Signal Generator SMA 100A

R&S SMB100N SIGNAL GENERATOR

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

R&S SMC100A Signal Generator Specifications

Agilent 8902A Measuring Receiver

Audio Analyzers UP 300/UP 350

Fluke 83V and 87V Digital Multimeters

Complimentary Reference Material

DSA700 Series Spectrum Analyzer

Frequency range 100 khz to 3 GHz 100 khz to 6 GHz 10 MHz to 18 GHz Reference frequency. 2 ppm in addition 2 ppm/10 C. 0 Hz, 100 Hz to 3 GHz

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

HP 8901B Modulation Analyzer. HP 11722A Sensor Module. 150 khz MHz. 100 khz MHz. Technical Specifications. Four Instruments In One

FSH3 100 khz to 3 GHz FSH6 100 khz to 6 GHz First Edition May 2004i

RADIATED IMMUNITY TEST SYSTEM 6 GHz

Spectrum Analyzer R&S FSP

METRAClip87 and 88 Clamp Multimeters

Advanced Test Equipment Rentals ATEC (2832)

N432A Thermistor Power Meter DATA SHEET

R&S FSV Signal Analyzer Specifications

True RMS Bench Multimeter 5492B

R&S FSV Signal and Spectrum Analyzer Specifications

True RMS Bench Multimeter 5492B

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

Spectrum Analyzers R3132/3132N/3162 R3132/3132N/3162. Low cost, high performance. General-Purpose Spectrum Analyzer Adaptable to Various Applications

2026Q CDMA/GSM Interferer MultiSource Generator

Agilent N9320B RF Spectrum Analyzer

FMU36 Baseband Signal Analyzer

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

R&S NRP-Zxx Power Sensors Specifications

R&S OSP Open Switch and Control Platform Specifications

Safety Evaluation Within a Magnetic Field Environment

Agilent E4428C ESG Analog Signal Generator

Complimentary Reference Material

MA24104A. Inline High Power Sensor. True-RMS, 600 MHz to 4 GHz

METRAHIT WORLD. International TRMS Multimeter /2.16. Features

Chapter 5 Specifications

METRATESTER 5+ Tester for DIN VDE /6.15

Phase Matrix, Inc. 545B 548B. Phase Matrix, Inc. EIP 545B and 548B CW Frequency Counters. Instruments You Can Count On

Keysight N9320B RF Spectrum Analyzer

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

GSM/EDGE Application Firmware R&S FS-K5 for R&S FSP and R&S FSU

Charge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...

R&S ZVL Vector Network Analyzer Specifications

R&S NRPC Calibration Kits Calibration of power sensors

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Spectrum Analyzer FSU

R&S OSP Open Switch and Control Platform Specifications

1587/1577 Insulation Multimeters

R&S FSWP Phase Noise Analyzer Specifications

Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Instant value. Extreme values ors statistic measurements

MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

Modulation Analyzers FMA/FMB

Keysight Technologies E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Advanced Test Equipment Rentals ATEC (2832)

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

DECLARATION OF CONFORMITY

R&S NRP USB and LAN Power Sensors Specifications

GAMMA 12 DIGITAL MULTIMETER

Keysight N9320B RF Spectrum Analyzer

Transcription:

Complimentary Reference Material This PDF has been made available as a complimentary service for you to assist in evaluating this model for your testing requirements. TMG offers a wide range of test equipment solutions, from renting short to long term, buying refurbished and purchasing new. Financing options, such as Financial Rental, and Leasing are also available on application. TMG will assist if you are unsure whether this model will suit your requirements. Call TMG if you need to organise repair and/or calibrate your unit. If you click on the Click-to-Call logo below, you can all us for FREE! TMG Corporate Website TMG Products Website Disclaimer: All trademarks appearing within this PDF are trademarks of their respective owners. Form 080/01

Level Meter URV35 Power and voltage measurements from DC to 40 GHz with analog/digital display Compact, handy and mobile Wide range of measuring heads Combined analog and digital display Battery or AC supply Menu-guided operation RS-232 interface

WF 43 227-3 General Operating concept Frequency-response correction Level Meter URV35 from Rohde & Schwarz is a versatile voltmeter and power meter. Its rugged design, optional battery or AC supply operation and a remote-control interface are key features that afford manifold applications. URV35 is just as suitable for use in service and production as for precise measurements in the laboratory. The large variety of measuring heads available for the URV5-Z and NRV-Z series opens up a wide level and frequency range to the URV35. The high RF shielding provides for precise measurements even in the near field of antennas ISO 9001 Certified Quality System DQS REG. NO 1954-04 URV35 is menu-controlled a feature that is normally found with larger instruments only. The menus allow the numerous measuring and setting functions to be selected in plain text and do away with difficult-to-remember numbers for special functions. Each measuring head is calibrated individually. The entire information stored in the measuring head such as calibration data, temperature response, frequency response, detector type is automatically evaluated in the URV35. The measuring head impedance is also taken into account so that the values displayed in W or dbm are always correct. Thanks to this intelligent operating concept and the autorange facility, the user has only to read the measurement result displayed. Resolution and measurement range The filtering which is dependent on the level and resolution as well as the optional 4 1 / 2 - or 3 1 / 2 -digit readout guarantee a perfect display of the measured values for every application. The autorange facility ensures the correct setup of the instrument. With the frequency-response correction being enabled, the correction data stored in the measuring head are automatically taken into account to increase the measuring precision. For this purpose, the frequency is entered manually or via the serial interface. However, the frequency can also be entered in terms of an equivalent DC voltage at the DC FREQ input of the URV35. The full calibration precision is thus utilized during manual measurements with sweep generators. For this type of measurement, just two pairs of values (start, stop frequency + corresponding voltages) need to be entered. Long-term measurements For long-term measurements, a YT recorder can be connected to the rear analog output. 2 Level Meter URV35

Measuring heads Probes URV5-Z1 395.0512.02 URV5-Z7 395.2615.02 with 20 db plugon divider*) with 40 db plugon divider*) DC Probe 1 mv to 400 V, 9 MΩ 3 pf RF Probe 200 µv to 10 V, 20 khz to 1 GHz For low-capacitance DC voltage measurements in RF circuits at minimum load For measurements in open RF circuits at low capacitive and resistive load 2 mv to 100 V, 1 to 500 MHz The 20 db and 40 db plug-on dividers increase the voltage measuring range of the RF probe; the high Q factor of the capacitive divider makes the resistive loading negligible, the capacitive loading goes down to 20 mv to 1000 V, 500 khz to 500 MHz 0.5 pf (40 db divider) With integrated termination for power or level measurements on test items with 50 Ω Adapter URV-Z50 200 µv to 10 V, 20 khz to 1 GHz with a source impedance of 50 Ω in the frequency range up to 1 GHz (BNC female/male) with 75 Ω Adapter URV-Z3 200 µv to 10 V, 20 khz to 500 MHz *) included in accessory URV-Z6 (Order No. 292.5364.02) With integrated termination for power or level measurements in 75 Ω systems such as antenna or video assemblies (BNC male) RF insertion units (with N male/female connectors) URV5-Z2 395.1019.02 URV5-Z4 395.1619.02 10 V Insertion Unit 50 Ω 200 µv to 10 V, 9 khz to 3 GHz 100 V Insertion Unit 50 Ω 2 mv to 100 V, 100 khz to 3 GHz Low-load RF voltage measurements in coaxial 50 Ω systems, low-loss power measurements on well-matched RF lines Virtually no-load RF voltage measurements in coaxial 50 Ω systems even at higher voltages. Due to minimum insertion loss and reflection coefficient this unit causes practically no interference on a 50 Ω line Power sensors (unless otherwise specified, power sensors come with N male connectors) NRV-Z1 828.3018.02 NRV-Z2 828.3218.02 NRV-Z3 828.3418.02 NRV-Z4 828.3618.02 NRV-Z5 828.3818.02 NRV-Z6 828.5010.02 NRV-Z15 1081.2305.02 NRV-Z31 857.9604.02/3/4 NRV-Z32 1031.6807.04/5 NRV-Z33 1031.6507.03/4 NRV-Z51 857.9004.02 NRV-Z52 857.9204.02 NRV-Z53 858.0500.02 NRV-Z54 858.0800.02 NRV-Z55 1081.2005.02 10 MHz to 18 GHz, 200 pw to 20 mw 10 MHz to 18 GHz, 20 nw to 500 mw Diode Power Sensor 75 Ω 1 MHz to 2.5 GHz, 100 pw to 13 mw 100 khz to 6 GHz, 100 pw to 20 mw 100 khz to 6 GHz, 10 nw to 500 mw 50 MHz to 26.5 GHz, 400 pw to 20 mw 50 MHz to 40 GHz, 400 pw to 20 mw Peak Power Sensor 50 Ω 30 MHz to 6 GHz, 1 µw to 20 mw Peak Power Sensor 50 Ω 30 MHz to 6 GHz, 100 µw to 2(4) W Peak Power Sensor 50 Ω 30 MHz to 6 GHz, 1 mw to 20 W DC to 18 GHz, 1 µw to 100 mw DC to 26.5 GHz, 1 µw to 100 mw DC to 18 GHz, 100 µw to 10 W DC to 18 GHz, 300 µw to 30 W DC to 40 GHz, 1 µw to 100 mw Power measurements of highest sensitivity up to 18 GHz in 50 Ω systems Power measurements with minimum mismatch, for high powers in 50 Ω systems Power measurements in 75-Ω systems Power measurements of highest sensitivity in the frequency range 100 khz to 6 GHz, very large dynamic range Like NRV-Z4, but for high powers and minimum mismatch Power measurements up to 26.5 GHz with high sensitivity in 50 Ω systems (PC3.5 connector, male) Power measurements up to 40 GHz with high sensitivity in 50 Ω systems (2.92 mm connector, male) Peak power measurements, pulse width 2 (200) µs, pulse repetition rate 10 (100) Hz, 3 models Peak power measurements, pulse width 2 (200) µs, pulse repetition rate 25 (100) Hz, 2 models Peak power measurements up to 20 W, pulse width 2 (200) µs, pulse repetition rate 100 Hz, 2 models High-precision power measurements also with non-sinusoidal signals Like NRV-Z51, but with PC3.5 connector (male) for measurements up to 26.5 GHz High-power measurements up to 10 W also with non-sinusoidal signals High-power measurements up to 30 W also with non-sinusoidal signals Like NRV-Z51, but with 2.92 mm connector (male) for measurements up to 40 GHz Level Meter URV35 3

Specifications Frequency range DC to 40 GHz, depending on sensor Display backlit LCD for display of measured value plus unit and for meter scale; additional moving-coil meter with short response time Readout absolute in dbm, V, W or dbµv relative in db referred to reference value Resolution of digital display HI: 4 1 / 2 digits (19,999 steps) 0.001 db with readout in db, dbm or dbµv LO: 3 1 / 2 digits (1,999 steps) 0.01 db with readout in db, dbm or dbµv Analog display steps of 1/2.5/5 with readout in V, W or db; steps of 5 (10) db with readout in dbm or dbµv and windows of 10(20) db, manually or automatically selected; free scaling by entry of lefthand and right-hand scale limits Display noise see diagram; negligible for DC Probe URV5-Z1 Display filtering level-dependent digital averaging filter 4 1 / 2 -digit resolution: averaging over 16 to 256 readings, 3 1 / 2 -digit resolution: averaging over 1 to 32 readings Measurement rate approx. 5 readouts per s in manual operation; measurement time in case of triggered measurement (RS-232): see diagram; with DC Probe URV5-Z1 approx. 0.1 s (3 1 / 2 digits) or 0.25 s (4 1 / 2 digits) Error limits Digital display Moving-coil meter 18 to 28 C ±0.02 db ±1 digit 1.5% of scale length 10 to 40 C ±0.04 db ±1 digit 2.5% of scale length 0 to 50 C ±0.06 db ±1 digit 3.5% of scale length Zero adjustment via RS-232 interface or key, duration approx. 4 s, for residual error see measuring head specifications Frequency-response correction sensor-specific calibration factors taken into account; input of frequency via keypad, serial interface or DC voltage at rear control input Attenuation compensation ext. attenuation or gain taken into account; data entry via serial interface or keypad, range ±199.99 db Input of reference value measured value on keystroke, or numerical value entered via serial interface or keypad HOLD function displayed measurement result retained upon keystroke Reference impedance 50 Ω or 75 Ω depending on sensor, Remote control 50 Ω/75 Ω selectable for RF probe all device functions controlled via serial interface (V.24, RS-232); X on /X off protocol; 110, 300, 1200, 2400, 4800, 9600 bauds; parity: odd, even, none; 8 data, 1 start, 1 stop plus 1 parity bit, if required; 9-contact D-sub connector (male) DC voltage input DC FREQ for control of frequency-response correction ±12 V (max. 50 V), 9 MΩ, freely selectable linear scaling, BNC connector (female) DC voltage output EMF proportional to pointer deflection, left-hand scale limit corresponding to 0 V, right-hand scale limit corresponding to +3 V, 1 kω source impedance, additional settling time 250 ms, error 5 mv, ripple typ. 5 mv pp, BNC connector (female) Sensor Check Source NRVS-B1 (option) Frequency 50 MHz, crystal-stabilized Power 1.00 mw; factory-set to ±0.7% (traceable to PTB) Deviation from nominal 1.2% max. (0.9% RSS) at 10 to 40 C or 1.6% (1.2% RSS) at 0 to 50 C, for 1 year in each case SWR 1.05 RF connector N female (at rear panel); N male/sma female adapter for NRV-Z6/-Z52/-Z15/ -Z55 included The sensor check source is permanently on. The operating time of one set of cells/ rechargeable batteries (model 02) is reduced by approximately 25%. General data Temperature range to DIN IEC 68-2-1/68-2-2 Operating 0 to +50 C Storage 40 to +70 C Permissible humidity Sinusoidal vibration Measurement time Display noise (2 x standard deviation) 10 1 s 0.1 0.3 0.1 db 0.01 0.001 4½ digits Add 0.1 s for NRV-Z31/-Z32/-Z33, models 03/04, 0.4 s for NRV-Z32, model 05, and 1 s for NRV-Z31, model 02 3½ digits max. 80%, without condensation 5 to 55 Hz, max. 2 g; 55 to 150 Hz, 0.5 g cont. (DIN IEC 68-2-6, IEC 1010-1, MIL-T-28800 D, class 5 complied with) Random vibration 10 to 500 Hz, 1.9 g rms (to DIN IEC 68-2-36) Shock 40 g shock spectrum (to MIL-STD-810 D; EMC Safety to EN 61010-1 Power supply Model 02 (battery operation) Model 02 (AC supply) Model 03 (AC supply) DIN IEC 68-2-27 complied with) to EN 50081-1 and 50082-1, EMC directive of EC (89/336/EEC) and EMC law of the Federal Republic of Germany 5 x 1.5 V dry cell LR20, approx. 125 h (included in scope of supplies), or 5 x 1.2 V NiCd storage battery to IEC KR35/62, approx. 60 h; charging time with UZ-35 approx. 24 h with plug-in Power Unit/Battery Charger UZ-35 for 230 V ±10%, 47 Hz to 63 Hz, Euro connector (Mod. 02) or 120 V ±10%, 57 Hz to 63 Hz, US connector (Mod. 04); dimensions of UZ-35: 96 mm x 55 mm x 58 mm 115 V +15%/ 22%, 47 to 440 Hz or 230 V +15%/ 22%, 47 to 63 Hz (selectable) 6 VA, safety class 1 to VDE 0411 and IEC 348, AC transformer with integrated thermal overload protection Dimensions (W x H x D) 219 mm x 103 mm x 240 mm Weight 3.1 kg with batteries (model 02) 2.4 kg (model 03) 4½ digits 0 +10 +20 db +30 Relative level referred to specific sensitivity *) *) Specific sensitivity of measuring heads: URV5-Z2/-Z7 200 µv ( 60 dbm) URV5-Z4 2 mv ( 40 dbm) NRV-Z1 1 nw ( 60 dbm) NRV-Z2 100 nw ( 40 dbm) NRV-Z3 400 pw ( 64 dbm) NRV-Z4 500 pw ( 63 dbm) NRV-Z5 50 nw ( 43 dbm) NRV-Z6/-Z15 2 nw ( 57 dbm) NRV-Z31 100 nw ( 40 dbm) NRV-Z32 10 µw ( 20 dbm) NRV-Z33 100 µw ( 10 dbm) NRV-Z51/-Z52/-Z55 1 µw ( 30 dbm) NRV-Z53 100 µw ( 10 dbm) NRV-Z54 300 µw ( 5 dbm) 3½ digits +10 +20 db +30 Relative level referred to specific sensitivity *) upper limit upper limit Level Meter URV35 4

urv35_de.fm Seite 5 Mittwoch, 2. Dezember 1998 10:59 10 Applications Unsurpassed display unit Analog or digital no problem for the URV35, as it has a combined analog/ digital display which optimally integrates the advantages of a true movingcoil meter with those of a digital display. The results are indicated in all the usual units of measurement either as absolute or relative values. The scaling on the LCD is freely selectable, which provides for an unprecedented ease of reading: In the AUTO mode, the measure- WF 39 815 ment range and the matching scale are selected automatically. In the FIX mode, the scale selected is retained. Scaling is made in steps of 1/2.5/5 as in the AUTO mode. The digital display shows correct values but the deflection of the analog pointer is limited according to the scale selected. WF 39 817-2 In the LIMIT mode, the desired lefthand and right-hand scale limits can be entered; this allows a specific section of the scale to be displayed (zoom function). Depending on the application, it is possible to choose between three display modes, ie analog, digital, analog plus WF 39 819 digital. The selectable display backlighting ensures good readability of the measured values even under unfavourable ambient lighting. WF 39 881-3 Ordering information Order designation Battery-operated model AC supply model Level Meter URV 35 Option Sensor Check Source NRVS-B1 1029.2908.02 Recommended extras Power Supply/Charger for European AC supply for US AC supply Transit Case Accessory Bag Carrying Strap Rack Adapter Service Kit UZ-35 UZ-35 UZ-22 ZZT-91 ZZT-96 ZZA-97 URV35-S1 1020.1709.02 1020.1709.04 1029.2008.02 0827.6365.00 0396.9813.00 0827.4527.00 1029.2608.02 1020.0002.02 1020.0002.03 Level Meter URV35 5

Fax Reply (Level Meter URV35) Others: Please send me an offer I would like a demo Please call me I would like to receive your free-of-charge CD-ROM catalog (including Test&Measurement Products) Name: Company/Department: Position: Address: Country: Telephone: Fax: E-mail: PD 756.9497.23 Trade names are trademarks of the owners Subject to change Data without tolerances: typical values Printed in Germany 1198 (Bi we) ROHDE&SCHWARZ GmbH & Co. KG Mühldorfstraße 15 D-81671 München P.O.B. 8014 69 D-81614 München Telephone +49894129-0 Internet: http://www.rsd.de CustomerSupport: Tel. +491805124242, Fax +4989 4129-3777, E-mail: CustomerSupport@rsd.rsd.de