Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Similar documents
Conductive Sensors 2 to 4-point level controller Type CL with potentiometer

Single Channel Loop Detector

USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS

PD132 Loop Detector Specification

Single Channel Loop Detector

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

SMARTSCAN INFORMATION

Single Channel Loop Detector

BEA s digital inductive single loop solution

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR

Short form User Manual

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

601/602 Series Inductive Loop Detector

MD12-2 Metal Loop Detector

Single Channel Loop Detector

AGP-0230 USER MANUAL AMANO

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC ULD 920

USER MANUAL ULD 910. October 2003 Revision: 03. Single Channel Vehicle Detector ULD 910. Part Number: MIC

Single Channel Loop Vehicle detector User Manual

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR

Single Channel Loop Detector

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Dual Channel Traffic/Parking Detector User Guide

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

FACTORY AUTOMATION. MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2

FG2 TWO-CHANNEL DETECTOR

Single Channel Loop Detector

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

27/04/2015

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

ULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

02/11/2015

38 Series - Relay interface modules A

05/09/2012

40 Series - Miniature P.C.B. Relays A

38 Series - Relay interface modules A

The power in relays and timers since Catalogue

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

MATRIX INDUCTIVE LOOP CONTROL BOX

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

48 Series - Relay interface modules A. Features

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Pluggable interface relays CR-U Universal relays

PD230 Enhanced Vehicle Detector USER MANUAL

Double Channel Loop Detector

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

With Audible Detect Signal

E-STOP relays, safety gate monitors

02/11/2015

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PART NUMBERING SYSTEM

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

PART NUMBERING SYSTEM

05/09/2014

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

62 Series - Power relays 16 A. Features / /

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Operations Manual. Model NT11 & NT11-E. June 18 th 2002

Relay interface modules A

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

PD140FNT60QMU-02C. Through Beam. Main features. Description

G2RL-1A G2RL-1 G2RL-2A G2RL-2

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

38 Series - Relay interface modules A. Features /

Monitoring Relays 3-Phase Active power Types DWB02, PWB02

Classification Enclosure rating Contact form Contact material

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Modular step relays 16 A

Photo-electric Amplifier ISG-A123 1-channel automatic amplifier

22/10/2012

MasterINTERFACE 39 Series - Relay interface modules

RME1-RME1BT INSTRUCCIONES DE INSTALACION INSTALLATIEVOORSCHRIFTEN INSTRUCTIONS D INSTALLATION ИНСТРУКЦИИ ПО УСТАНОВКЕ ISTRUZIONI DI INSTALLAZIONE

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers


Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

MasterINTERFACE 39 Series - Relay interface modules

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

SVP CONTROL AND VISUALIZATION OF VOLTAGE, PHASE AND FREQUENCY IN THREE-PHASE LINES WITH NEUTRAL

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

REMOTE SENSOR SERIES. Description

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Transcription:

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation via 11 pin circular plug Rated operational voltage: 24 VAC/DC, 115 VAC or 230 VAC Pulse or presence relay output Output 1A/250 VAC SPDT relay LED indication for power, relay status and loop fault boost only LDP1 Selectable frequency prevents cross-talk Direction logic only LDP2 Product Description Loop detectors for detection of vehicles. The vehicle loop detector is designed to handle all parking, drive-through and access control applications for controlling doors, gates, barriers or fences. Type Selection The principle is based on a change in the inductance within the loop when a metallic object (vehicles) is passing. The microprocessor evaluates the changes. Ordering Key Type Plug mounting Loop inputs Function Adjustment Outputs Relay versions Power supply LDP1 SA1 B 230 Mounting Relay Ordering no. Ordering no. Ordering no. Supply: 24 VAC/DC Supply: 115 VAC Supply: 230 VAC Single loop SPDT LDP1SA1BM24 LDP1SA1B115 LDP1SA1B230 Dual loop SPST LDP2TA2BM24 LDP2TA2B115 LDP2TA2B230 Specifications Rated operational voltage (U B) Pin 2 & 1 230 195 to 265 VAC, 45 to 65 Hz 115 98 to 132 VAC, 45 to 65 Hz M24 19.2 to 28.8 VAC/DC Rated insulation voltage <2.0 kvac (rms) Rated impulse withstand voltage 4 kv (1.2/50 µs) (line/neutral) Rated operational power AC supply AC/DC supply Power on delay (t V) Outputs Minimum switching current Rated insulation voltage 3 VA 1.5 VA / 1.5 W < 10 sec Typ. 4 sec 10 ma @ 12 V 250 VAC (rms) (cont./elec.) Relay Rating (AgNi 90/10) µ (micro gap) Resistive loads AC1 1 A / 250 VAC (250 VA) DC1 1 A / 30 VDC (30 W) Mechanical life (typical) 15 x 10 6 operations @ 18 000 imp/h Electrical life (typical) AC1 > 250 000 operations 8 sensitivity settings available Frequency range 13-120 khz Loop inductance 15-1500 µh Operating frequency (f) Relay output Response time 1 HZ 400 ms Environment Overvoltage category III (IEC 60664) Degree of protection IP 20 (IEC 60529, 60947-1) Pollution degree 2 (IEC 60664/60664A, 60947-1) Temperature Operating Storage Housing material Weight AC supply AC/DC supply Approvals CE marking -40º to +70ºC (-40º to + 158ºF) -50º to +85ºC (-58º to +185ºF) NORYL SE1, light grey 150 g 85 g UL508, CSA Yes Specifications are subject to change without notice (10.07.2009) 1

Mode of Operation Application The LDP Vehicle Loop Detector is based on microprocessor technology, which has enabled a large number of functions to be implemented. The functions are primarily for use in the Parking/Access Control Industry like control for gates, barriers, fences, etc. Standard operations are implemented including programmable pulse and presence option. Principle The Vehicle Loop Detector is based on the inductive principle, using a coil of wire buried in the driveway and connected to the loop detector. The change in inductance will be measured as a change in frequency. The output relay activates when the loop is activated and releases again when the loop returns to a non-activated condition. Setup The loop has to be in a passive condition (no object in the loop area) during startup and adjustment. The loop detector will automatically calibrate when the reset button has been activated, which will be indicated by the yellow LED flashing. The functioning can now be checked by activating the loop with the actual object. Now the yellow LED will go on, and the output relay will be activated according to the dip-switch settings. If the loop detector does not react, the sensitivity must be manual adjusted by means of the dip-switches. Important: reset the system after changing the Dipswitch settings. Temperature compensation The frequency will increase as a result of decreasing temperatures and vice versa. To compensate for this, or any other situation that courses slowly change in frequency, the LD auto tunes constantly. That means if the frequency changes slowly there will be no detection. The auto tune function compensates for both increasing or decreasing in frequency. Fault detection This function is useful if the cable disconnect. The alarm will be indicated via the red LED in front of the housing. This LED is constantly lighting when the loop is open or too large and flashing when a short circuit occurs or a loop is too small. Loop Under Roadway 8 sensitivity settings are available on the dip-switches in front of the module, to allow flexibility in configuration and application (Compensation for variation in loop construction). Reset switch The reset switch enables the detector to be manually reset during commissioning and testing. The detector will re-tune the sensing loop and become ready for vehicle detection. Relay output The single loop detector has two SPDT relays one for pulse output and one for presence output. The dual loop detector has two SPST relays one for each loop. Pulse output (one shot): It is possible to select the length of the output period to 0.2s or 1 second. The pulse output can be setup to activate on detection of a vehicle or when the vehicle leaves the loop. Presence output: The output will be activated as long as there is a vehicle parked in the loop. It will be possible to activate a filter (-delay of 2 seconds), which prevents a false detection from a small or fast moving object. Pulse output mode The relay activates only for a short period when the vehicle enters or leaves the loop. Permanent output mode The relay will remain active as long as there is a vehicle parked in the loop. Extends the pulse length from 0.2 sec to 1 sec. On-delay Prevents false detections of small or fast moving objects. Sense boost (only single channel loop detector) This feature sets the undetected level to maximum sensitivity and is used to prevent loss of detection of high-bed vehicles. Selectable frequency The frequency of the loop is determined by the inductance of the loop and the frequency switch setting. If the frequency switch is on, the frequency is reduced. It may be necessary to change the frequency to prevent cross talk between adjacent loops. The frequency function will only change the frequency of one channel of the dual loop detector. Important: Be careful when installing the detector next to another inductive load, as this can have an effect on the detector and cause false detections. Operation Diagram LDP1 / Presence and Pulse mode Vehicle Entering Vehicle Leaving Loop Relay 1, Presence t : 2 s 2 Specifications are subject to change without notice (10.07.2009)

Operation Diagram (cont.) LDP2 / Direction Logic Mode Vehicle Passing, 1 to 2 Vehicle Passing, 2 to 1 t : 2 s t : 2 s LDP2 / Presence Mode Vehicle Passing Relay 1, Presence t : 2 s Relay 2, Presence t : 2 s LDP2 / Pulse Entering Vehicle Entering t : 2 s t : 2 s LDP2 / Pulse Leaving Vehicle Leaving t : 2 s t : 2 s Specifications are subject to change without notice (10.07.2009) 3

Dip Switch Settings LDP1 LDP2 Minimum Maximum 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 1 sec 0.2 sec 4 4 Leaving 5 5 6 6 7 7 A 8 8 Entering 2 sec On B 1 sec 0.2 sec 4 4 Leaving 5 5 6 6 Pulse 7 7 A 8 8 Entering 2 sec Pulse mode On delay boost Loop frequency Cross talk Presence Pulse/presence mode B Pulse mode On delay Loop frequency Cross talk Direction logic Function The Dual loop detector (LDP2) is implemented with direction logic as standard. The function enables the detector to give a pulse output on relay#1 for a vehicle travelling from loop 1 to loop 2 and a pulse output on relay#2 for a vehicle travelling from loop 2 to loop 1. Direction Relay 2 Important: Reset the detector after changing the Dip-switch settings If a vehicle is detected, and the corresponding direction is indicated, both loops must be in a non-activated condition again before the next object can be detected. For Direction logic mode set Dipswitch 5 to Entering and Dipswitch 7 to Presence. Relay 1 Direction Loop Diagram Loop installation The loop geometry must be adapted to the respective application. The setup will be optimal if the loop has the same size as the object to be detected. After determining the loop geometry, a groove must be cut in the ground for installing the loop. Cut an inclined groove of 45 angle at the corners of the loop, which will protect it from excessive wear. Clean the groove for moisture and place the wire as tight as possible along the button of the groove. Before sealing up the groove, it is recommandable to check the loop inductance using a measuring device. Optimum value: 80-300 µh. When sealing up the groove, ensure that the temperature of the sealing compound does not exceed the max temperature of the loop insulation, as this might cause an earth fault. Loop turns The number of turns strongly depends on the circumference of the loop. The smaller the loop, the more turns are required. Cable Recommandations - Use 1.5mm squared cable. Use silicon coated cable, if placed directly into the ground - Use 2m of spacing between two adjacent loops. - Use screened feeder cable in electrically noisy environments or where feeder runs parallel to power cables. Max Max depth depht into road: 50mm Typical 30 mm Loop circumference No. of turns (m) >10 2 6-10 3 <6 4 300 mm Twisted wire --> 20 Twisted turns wire per meter -> 20 turns per meter max length: 20 mt max lenght: 20 m 45 2 m 1 m ROAD 300 mm 4 Specifications are subject to change without notice (10.07.2009)

Dimension Drawing Wiring Diagram Plug version 45 LDP1 63 μ Pulse Pres 5 4 3 6 7 8 9 21 2 1 11 10 SUPPLY 80 35,5 LDP2 Loop 2 μ 4 3 5 6 7 Loop 2 8 9 2 1 11 10 SUPPLY Pin configuration Pin n. Single Channel Detector Dual Channel Detector 1 Supply Supply 2 Supply Supply 3 Pulse relay NO NO Loop #1 4 Pulse relay COM Loop #1 5 Presence relay NO Loop #2 6 Presence relay COM Loop #2 7 Loop Pulse/Presence relay #2 NO 8 Loop Pulse/Presence relay #2 COM 9 Earth Earth 10 Presence relay NC Pulse/Presence relay #1 NO 11 Pulse relay NC Pulse/Presence relay #1 COM Accessories Delivery Contents 11-pole circular socket ZPD11 Detector Packaging: Carton box Specifications are subject to change without notice (10.07.2009) 5