RMV-122D, RMV-132D ANSI

Similar documents
DATA SHEET Differential current relays, RMC-131D ANSI code 87

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

DATA SHEET Selectable AC transducer TAS-311DG

DEIF A/S. Insulation monitor. Type SIM-Q

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

TCM-2 Thyristor Control Module DATA SHEET

DEIF A/S. User s manual. Read synchroscope type RSQ-3. Precision LED synchronoscope. High immunity to harmonic distortion F (UK)

DATA SHEET. Voltmeters and Ammeters,

Function. Adjustment. Extra functions included. Modes. Housing

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

Automatic synchronising relay

Installation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar

DATA SHEET. Switchboard instruments,

Installation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar

Installation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

27/04/2015


Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current

Installation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10...

Installation / Monitoring Technique

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

DEIF A/S. Application note. Generators parallel with mains Multi-line 2 version 2. Application description. Power import control. Power export control

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Multi Differential Relay, MDR-2 DESCRIPTION OF OPTIONS

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

DEIF A/S. Application Notes. MDR-2 test procedures. Test of current measurement. Test of differential current measurement.

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

Summation current transformers, type KSU/SUSK

Primary winding current transformer, type WSK

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

XUA1 - AC Voltage and phase balance relay

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

ISOMETER IRDH575. Approvals

Electronic relays. Monitoring. Monitoring

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Installation- / Monitoring technique

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Three-phase monitoring relay CM-PFS

XF2 Frequency Relay. Manual XF2 (Revision A)

RCMS460 and RCMS490 Series

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Zelio Control Measurement Relays

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

22/10/2012

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-SDS.22

Single-phase Current Relay

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Installation Instructions and Reference Handbook. Installation instructions

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Type Nominal voltage (V) Code HSV V

Functional Safety Application Guide

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Reactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

05/09/2014

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

CM-IWM.11 Insulation monitoring relay

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Protection and safety SQZ3 phase and sequence relay

Three-phase monitoring relays

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

Liquid level monitoring relay CM-ENS.2x

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Transcription:

DATA SHEET Voltage relays, RMV-112D, RMV-122D, RMV-132D ANSI codes 27/59, 59, 27 Under-voltage/over-voltage 3-phase measurement LED indication of fault condition Timer-controlled tripping LED indication for activated relay DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921240096I SW version:

1. General information 1.1. Application and features...3 1.1.1. Application... 3 1.1.2. Measuring principle...3 1.1.3. Timer functions... 3 1.1.4. Relay outputs...4 2. Technical information 2.1. Technical specifications and dimensions...5 2.1.1. Technical specifications... 5 2.1.2. Settings and indication...6 2.1.3. Connections/dimensions (in mm)... 7 3. Ordering information 3.1. Order specifications and disclaimer... 8 3.1.1. Available variants...8 3.1.2. Order specifications...8 3.1.3. Disclaimer...8 DEIF A/S Page 2 of 8

General information 1. General information 1.1 Application and features 1.1.1 Application The protective voltage relays types RMV-112D, RMV-122D and RMV-132D form part of a complete DEIF series of relays for protection and control of generators and are applicable to both marine and land-based installations. Also available are voltage relays for single phase measurement (RMV-142D). The relays are type-approved by major classification societies. The voltage relays are applied for protection of generators, motors and transformers against adverse system voltage conditions. The relay supervises all 3-phase voltages. The following types are available: - Type RMV-112D (ANSI codes 27/59) under-voltage and over-voltage relay (U< + U>) - Type RMV-122D (ANSI code 59) over-voltage relay (2 levels: U> + U>) - Type RMV-132D (ANSI code 27) under-voltage relay (2 levels: U< + U<) 1.1.2 Measuring principle The relays measure all 3-phase voltages, providing an RMS measurement of sinusoidal voltages. Under-voltage/over-voltage (U< + U>) If the voltage either drops below the lower set point or exceeds the upper set point, the associated output is activated. Over-voltages (U> and U>) The highest input voltage is detected, and if this exceeds its set point, the output is activated. Under-voltages (U< and U<) The lowest input voltage is detected, and if this is lower than the set value, the output is activated. The set point values are set on the front of the relays by means of potentiometers. 1.1.3 Timer functions When the set point is exceeded, the associated timer starts and will run as long as the fault condition prevails. The delay does not depend on the exceeding of the set point. If the fault disappears, the timer is reset. When the timer expires, the contact and its built-in hysteresis circuit are activated and the associated red LED is lit. Hysteresis The relays are provided with an adjustable hysteresis (common to both contacts), that is a difference of 1 to 10 % of U n between energising and de-energising of the relay. The relay is deactivated when the fault voltage equals or is less than the preset hysteresis. DEIF A/S Page 3 of 8

General information 1.1.4 Relay outputs The relays are provided with two outputs: U< outputs with a minimum contact, U> outputs with a maximum contact, either normally energised or normally de-energised. The contact may be set to open or to close on activation. Normally energised contact Recommended for land-based installations for warning and alarm purposes. In case of an auxiliary supply dropout, the contact is immediately activated. Normally de-energised contact Recommended for marine installations for regulating and control purposes. An auxiliary supply failure will not result in an unwanted activation of the contact. Latch circuit The contact can be locked in its warning position, even if the input voltages return to normal (add "L" to contact type in order specifications if this is required). The latch circuit is reset by disconnecting the auxiliary supply. Power-up/power-down circuits The relays are provided with a 200 ms power-up circuit, ensuring the correct function of the relay on connection of the auxiliary voltage. Normally energised contacts are not activated (contact does not open/close) until 200 ms after connection of the auxiliary voltage. Likewise, the relays are provided with a 200 ms power-down circuit, ensuring supervision and maintenance of any set point exceedings for 200 ms after disconnection of the auxiliary voltage. DEIF A/S Page 4 of 8

Technical information 2. Technical information 2.1 Technical specifications and dimensions 2.1.1 Technical specifications Meas. range (U n ) Frequency range Max. input voltage 57.7-63.5-100-110-127-200-220-230-240-380-400-415-440-450-480-660-690 V AC UL/cUL Listed: 57.7 to 450 V AC 40 to 45 to 65 to 70 Hz 1.2 U n, continuously 2 x U n for 10 s Load Outputs Contact type Relay contacts Contact ratings Contact voltage Response time Temperature 2 kω/v RMV-112D 1 minimum + 1 maximum contact RMV-122D 2 maximum contacts RMV-132D 2 minimum contacts Relays B + C: Normally energised ("NE"), or normally de-energised ("ND") with or without latch circuit ("L") 1 change-over switch per relay 250 V AC/24 V DC, 8 A (200 x 10 3 change-overs at resistive load) UL/cUL Listed: Resistive load only Max. 250 V AC/150 V DC <100 ms -25 to 70 C (-13 to 158 F) (operating) UL/cUL Listed: Max. surrounding air temp. 60 C/140 F Temperature drift Set points: Max. 0.2 % of full scale per 10 C/50 F Galv. separation Supply voltage (U n ) Climate HSE, to DIN 40040 Between inputs and outputs: 3250 V - 50 Hz - 1 min. 57.7-63.5-100-110-127-220-230-240-380-400-415-440-450-480-660-690 V AC ±20 % (max. 3.5 VA) 24-48-110-220 V DC -25/+30 % (max. 2 W) UL/cUL Listed: Only 24 V DC and 110 V AC DC supply must be from a class 2 power source EMC To IEC/EN 61000-6-1/2/3/4 Connections Materials Max. 4.0 mm 2 (single-stranded) Max. 2.5 mm 2 (multi-stranded) All plastic parts are self-extinguishing to UL94 (V1) Protection Case: IP40. Terminals: IP20, to IEC 529 and EN 60529 Type approval The Uni-line components are approved by the major classification societies. For current approvals see www.deif.com or contact DEIF A/S. DEIF A/S Page 5 of 8

Technical information UL markings 2.1.2 Settings and indication Setting of LED Relay Under-voltage limit: "U<" Yellow LED is lit when the input voltage is lower than the preset limit, but (80 to 100 %) of U n the relay has not yet been activated Over-voltage limit: "U>" Yellow LED is lit when the input voltage exceeds the preset limit, but the (100 to 120 %) of U n relay has not yet been activated Time delay: (0 to 10 s) in seconds UL Listed only on request UL Listing will be lost if the product is re-customised outside DEIF DK's production plant Wiring: Use 60/75 C (140/167 F) copper conductors only Wire size: AWG 12-16 or equivalent Installation: To be installed in accordance with the NEC (US) or the CEC (Canada) "RE- LAY" Relay is activated and red LED lit after the timer has expired Hysteresis: Relay contact is reset when fault voltage equals or is less than the preset (1 to 10 %) of U n hysteresis The relays are furthermore equipped with a green LED marked "POWER" for indication of power ON. Once the relay has been mounted and adjusted, the transparent front cover may be sealed to prevent unwanted change of the setting. DEIF A/S Page 6 of 8

Technical information 2.1.3 Connections/dimensions (in mm) AUX SUPPLY + ~ ~ - RELAY B RELAY C AUX SUPPLY + ~ ~ - RELAY B RELAY C 1 3 6 7 8 X1 X2 B C 13 14 15 1 3 6 7 8 X1 X2 B 13 14 15 C RMV-112D RMV-122D RMV-132D N L1 L2 L3 L1 L2 L3 16 17 19 21 17 19 21 RMV-112D RMV-122D RMV-132D L1 L1 L2 L2 L3 L3 N Star coupling Delta coupling Shown contact positions: Aux. voltage not connected 85.0 75.0 61.0 4.5 99.7 110.0 Weight: Approx. 0.650 kg DEIF A/S Page 7 of 8

Ordering information 3. Ordering information 3.1 Order specifications and disclaimer 3.1.1 Available variants Item no. Variant no. Variant description 2913210120 01 RMV-112D - DC supply 2913210120 02 RMV-112D - AC supply 2913210530 01 RMV-122D - DC supply 2913210530 02 RMV-122D - AC supply 2913210660 01 RMV-132D - DC supply 2913210660 02 RMV-132D - AC supply 3.1.2 Order specifications There are no additional options to the standard variant. Variants Mandatory information Item no. Type Variant no. Coupling Measuring voltage (U n ) Relay B Relay C Supply voltage Example: Mandatory information Item no. Type Variant no. Coupling Measuring voltage (U n ) Relay B Relay C Supply voltage 2913210120-01 RMV-112D 01 Delta 400 V AC NDL NDL 24 V DC 2913210530-02 RMV-122D 02 Star 230 V AC NDL NDL 230 V AC 2913210660-01 RMV-132D 01 Delta 400 V AC NE NE 110 V AC 3.1.3 Disclaimer DEIF A/S reserves the right to change any of the contents of this document without prior notice. DEIF A/S Page 8 of 8