Disturbance Elimination for Partial Discharge Detection in Spacer of Gas-Insulated Switchgears

Similar documents
LEVEL DEPENDENT WAVELET SELECTION FOR DENOISING OF PARTIAL DISCHARGE SIGNALS SIMULATED BY DEP AND DOP MODELS

Partial Discharge Source Classification and De-Noising in Rotating Machines Using Discrete Wavelet Transform and Directional Coupling Capacitor

ANALYSIS OF PARTIAL DISCHARGE SIGNALS USING DIGITAL SIGNAL PROCESSING TECHNIQUES

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

The Application of Partial Discharge Measurement and Location on CGIS

NOISE REDUCTION AND SOURCE RECOGNITION OF PARTIAL DISCHARGE SIGNALS IN GAS-INSULATED SUBSTATION

Partial Discharge Patterns in High Voltage Insulation

Simulation Model of Partial Discharge in Power Equipment

IEEE Transactions on Power Delivery. 15(2) P.467-P

Frequency Spectrum Analysis of Electromagnetic Waves Radiated by

Abstract. 1 Introduction

High Field Electrical Conduction and Breakdown in Solid Dielectrics

WAVELET TRANSFORM ANALYSIS OF PARTIAL DISCHARGE SIGNALS. B.T. Phung, Z. Liu, T.R. Blackburn and R.E. James

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

Why partial discharge testing makes good sense

Non-intrusive Measurement of Partial Discharge and its Extraction Using Short Time Fourier Transform

An UWB Printed Antenna for Partial Discharge UHF Detection in High Voltage Switchgears

PULSE-SEQUENCE ANALYSIS OF PARTIAL DISCHARGES IN POWER TRANSFORMERS

Multi-Resolution Wavelet Analysis for Chopped Impulse Voltage Measurements

Analysis of Partial Discharge Detection in Power Cable by WTST-NST Filter Technology

Application of Wavelet Transform Technique for Extraction of Partial Discharge Signal in a Transformer

Partial Discharge Classification Using Novel Parameters and a Combined PCA and MLP Technique

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES

INVESTIGATION ON THE TECHNOLOGIES FOR DEFECT LOCALIZATION AND CHARACTERIZATION ON MEDIUM VOLTAGE UNDERGROUND LINES

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer

The Analysis of GIS Defect Model Partial Discharge Test

SDMF based Interference Rejection and PD Interpretation for Simulated Defects in HV Cable Diagnostics

Measurement Of Partial Discharge (PD) In High Voltage Power Equipment

Suppression of Pulse Interference in Partial Discharge Measurement Based on Phase Correlation and Waveform Characteristics

Basics of Partial Discharge. Prepared for 2015 Phenix RSM Meeting January 2015

Fault Location Technique for UHV Lines Using Wavelet Transform

Self-adaptive partial discharge signal de-noising based on ensemble empirical mode decomposition and automatic morphological thresholding

Nonlinear Filtering in ECG Signal Denoising

Comparison of capacitive and inductive sensors designed for partial discharges measurements in electrical power apparatus

Application of Singular Value Energy Difference Spectrum in Axis Trace Refinement

PD Solutions. On-Line PD Measurement Devices

ANALYSIS OF PARTIAL DISCHARGE SIGNALS USING STOCKWELL TRANSFORM

Classification of Voltage Sag Using Multi-resolution Analysis and Support Vector Machine

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

THE POWER OF LIFE. WinTech Partial Discharge based Predictive Intelligence of insulation system to eliminate power failure risk.

Sound pressure level calculation methodology investigation of corona noise in AC substations

HVDC Transmission. Michael Muhr. Institute of High Voltage Engineering and System Performance Graz University of Technology Austria P A S S I O N

KEYWORDS On-line diagnostics, cable termination, partial discharge (PD), ultra-high frequency (UHF), sensitivity check.

UHF PD-DIAGNOSIS AT HIGH VOLTAGE CABLE TERMINATIONS INTERNATIONAL CASE STUDIES

Investigation of PD Detection on XLPE Cables

Application of spectrum estimation and wavelet packet transform in suppression of partial discharge s discrete spectral interference

Partial Discharge Signal Detection by Piezoelectric Ceramic Sensor and The Signal Processing

Oil metal particles Detection Algorithm Based on Wavelet

The importance of partial discharge testing throughout the development and operation of power transformers

Extended analysis versus frequency of partial discharges phenomena, in support of quality assessment of insulating systems

Coherence and time-frequency analysis of impulse voltage and current measurements

PD ANALYSIS OF GAS INSULATED MEDIUM VOLTAGE SWITCHGEAR DURING FACTORY ASSEMBLY AND SITE COMMISSIONING

This is an author-deposited version published in : Eprints ID : 18223

PD Diagnostic Applications and TechImp solutions

Diagnostic testing of cast resin transformers

Research Article Design of a UHF Antenna for Partial Discharge Detection of Power Equipment

CONTINUOUS ON-LINE MONITORING OF PARTIAL DICHARGES IN HV DISTRIBUTION CABLES

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

1409. Comparison study between acoustic and optical sensors for acoustic wave

NOISE REDUCTION OF PARTIAL DISCHARGE SIGNALS USING LINEAR PREDICTION AND WAVELET TRANSFORM

The Elevator Fault Diagnosis Method Based on Sequential Probability Ratio Test (SPRT)

AC CREEPAGE DISCHARGES IN SF 6, CO 2, N 2 AND SF 6 -CO 2 AND SF 6 - N 2 MIXTURES

Open Access Application of Partial Discharge Online Monitoring Technology in ± 660kV Converter Transformer

Chapter 5. Signal Analysis. 5.1 Denoising fiber optic sensor signal

IEEE (2016) (2016). IEEE.,

A COMPARATIVE STUDY: FAULT DETECTION METHOD ON OVERHEAD TRANSMISSION LINE

Introduction to Wavelet Transform. Chapter 7 Instructor: Hossein Pourghassem

Open Access Research of Dielectric Loss Measurement with Sparse Representation

Spectrum and Energy Distribution Characteristic of Electromagnetic Emission Signals during Fracture of Coal

Simulation of Partial Discharge in High Voltage Power Equipment

Prediction of Transient Transfer Functions at Cable-Transformer Interfaces

International Conference on Information Sciences, Machinery, Materials and Energy (ICISMME 2015)

Partial Discharge Signal Denoising by Discrete Wavelet Transformation

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

Detection of Partial Discharges and its Effect on Solid Insulation used in High Voltage Cable

Testing of 400 kv GIS

technology, Algiers, Algeria.

A COMPARISON OF AC AND DC PARTIAL DISCHARGE ACTIVITY IN POLYMERIC CABLE INSULATION *

HV AC TESTING OF SUPER-LONG CABLES

LabVIEW Based Condition Monitoring Of Induction Motor

IMPROVING THE MATERIAL ULTRASONIC CHARACTERIZATION AND THE SIGNAL NOISE RATIO BY THE WAVELET PACKET

Software System for Finding the Incipient Faults in Power Transformers

CVVOZE Power Laboratories (CVVOZEPowerLab)

WAVELET DE-NOISING AND ANALYSIS OF UHF PARTIAL DISCHARGES IN HIGH VOLTAGE POWER TRANSFORMER

Partial Discharge Classification Using Acoustic Signals and Artificial Neural Networks

World Journal of Engineering Research and Technology WJERT

USING DAMPED AC VOLTAGES

Denoising different types of acoustic partial discharge signals using power spectral subtraction

Partial Discharge Measurements on 110kV Current Transformers. Case Study. Results

Enhancement of Speech Signal by Adaptation of Scales and Thresholds of Bionic Wavelet Transform Coefficients

Corona noise on the 400 kv overhead power line - measurements and computer modeling

PD Testing Considerations for MV Plant Cables

The Influence of Antenna Positioning Errors on the Radio-Frequency Localization of Partial Discharge Sources

Development of Bolt Crack Detection Device Based on Ultrasonic Wave

Partial Discharge Inception and Propagation Characteristics of Magnet Wire for Inverter-fed Motor under Surge Voltage Application

Ferroresonance Signal Analysis with Wavelet Transform on 500 kv Transmission Lines Capacitive Voltage Transformers

Open Access Partial Discharge Fault Decision and Location of 24kV Composite Porcelain Insulator based on Power Spectrum Density Algorithm

Application of Wavelet Transform to Process Electromagnetic Pulses from Explosion of Flexible Linear Shaped Charge

Open Access Sparse Representation Based Dielectric Loss Angle Measurement

Transcription:

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Article Disturbance Elimination for Partial Discharge Detection in Spacer of Gas-Insulated Switchgears Guoming Wang 1, Gyung-Suk Kil 1,*, Hong-Keun Ji 2 and Jong-Hyuk Lee 3 1 Department of Electrical and Electronics Engineering, Korea Maritime and Ocean University, Busan 49112, Republic of Korea; journey@kmou.ac.kr 2 Forensic Safety Section, National Forensic Service Busan Institute, Yangsan, 50612, Republic of Korea; hkji1024@korea.kr 3 HVDC Production Team, LSIS Co., Ltd, Busan, 46739, Republic of Korea; jhlee5@lsis.biz * Correspondence: kilgs@kmou.ac.kr; Tel.: +82-51-410-4414 Abstract: With the increasing demand for precise condition monitoring and diagnosis of gas-insulated switchgears (GIS), it has become a challenge to improve the detection sensitivity of partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the capacitive component from the phase resolved partial discharge (PRPD) signal generated in GIS spacer based on the discrete wavelet transform. Three types of typical insulation defects were simulated using PD cells. The single PD pulses were detected and were further used to determine the optimal mother wavelet. As a result, the bior6.8 was selected to decompose the PD signal into 8 levels and the signal energy at each level was calculated. The decomposed components related with capacitive disturbance were discarded whereas those associated with PD were de-noised by a threshold and a thresholding function. Finally, the PRPD signals were reconstructed using the de-noised components. Keywords: partial discharge; gas-insulated switchgears; spacer; capacitive component; wavelet transform; multi-resolution analysis 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 1. Introduction Detection and analysis of partial discharge (PD) in insulation structures for gas-insulated switchgears (GIS), transformers, cables, and rotating machines are important to ensure their stable and reliable operation [1-6]. Among the components of GIS, the epoxy spacer is a critical part and can result in eventual failure of GIS. It is usually examined by AC withstand voltage tests with high electrical stress and by PD tests [7], [8]. It is specified that the maximum permissible PD level for GIS should not exceed 5 picocoulombs (pc) [9]. It is also indicated that the spacer should be replaced if the PD induced in spacer is greater than 1 pc [7]. However, the sensitivity of PD measurement is influenced by the capacitive current flowing in the GIS test section, especially in the spacer. Figure 1 shows a PD signal detected within a cycle of the applied voltage, accumulation of such signals forms the phase-resolved partial discharge (PRPD) pattern. It can be seen that the disturbance due to the capacitive component is so high that the PD signal is seriously overlapped. Since the PRPD pattern is extracted using the peak detection technique, such distortion lowers the sensitivity of PD measurement and invalidates the specific feature of a defect, consequently, making it inaccurate for defect identification. This problem has been dealt with by applying a high pass filter (HPF), however, it is difficult to determine the exact cutoff frequency of the filter since an improper filter attenuates the magnitude of PD. In addition, the filter cannot remove the disturbance completely. 2017 by the author(s). Distributed under a Creative Commons CC BY license.

2 of 13 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 Figure 1. Partial discharge (PD) signal detected within a cycle of applied voltage in gas-insulated switchgear (GIS) spacer. The wavelet transform (WT) is an effective signal processing method and has achieved its application in the field of condition monitoring and diagnosis. It has been used for de-nosing of the ultra-high frequency signal and eliminating the corona from PD signal [11-16]. In addition, parameters derived from wavelet decomposition are implemented in the feature extraction for defect classification [17], [18]. Satish L. and Nazneen B. studied the de-noising of PD signals buried in excessive discrete spectral, stochastic, and random interferences using the WT method. The simulated signals and pulses detected from a point-plane gap were analyzed. The results revealed that the wavelet method was successful in rejecting all the three types of interference [11]. Ma X. et. al. proposed the automatic level-dependent thresholding criterion for de-noising the damped exponential and damped oscillatory pulses immersed in noise when the narrow-band and the ultra-band detection circuit were used [12]. Zhou X. et. al. introduced the filter pairs for wavelet decomposition and analyzed the frequency bands of the wavelet coefficients. By investigating the energy distribution at each decomposition level, the de-noising effect was significantly improved [13]. Zhang H.et al. implemented WT technique to reject noise in on-site PD measurement in cables. The continuous sinusoidal noise, pulse-like noise, and white noise were successfully rejected [14],[15]. Chang C. S. et. al. presented separation of corona form PD signal by wavelet packet transform and neural network method. The parameters including node energy, kurtosis, and skewness were calculated and used for characterizing PD signal and corona [16]. However, few works have been carried out to deal with the capacitive current for PD detection in GIS spacer using the WT method. This paper discusses the elimination of the capacitive component based on the WT technique for the purpose of improving the PD detection sensitivity in GIS spacer. 2. Insulation Defects in Spacer Although various types of insulation defects have been introduced and evaluated, the ones existing in an epoxy spacer are regarded as the most critical and initiate the failure of GIS. Such defects are usually minute imperfections that are difficult to be detected, including a void inside spacer (VIS), a particle on spacer (POS), and a crack [6], [19], [20]. The VIS is the result from air bubbles produced during the manufacturing process of solid spacers, such as high temperature casting and curing of epoxy. The POS is a conductive contaminant or particle which adheres to the surface of insulating materials. The crack is one of the most common defects in GIS, which is formed due to mechanical impacts from the outside, operations of circuit breaker, and strains generated by heat shock [7], [8], [21]. These three types of defects were simulated using artificial PD cells and the epoxy resin insulator for GIS spacer was used. The PD cells were filled with SF6 gas with a pressure of 0.5 MPa. Figure 2 shows a PD cell for POS. The plane electrodes were made of tungsten copper alloy with a diameter of 80 mm and a thickness of 20 mm. Their edges were rounded to prevent the concentration of the electric field [22]. An epoxy insulator with a height of 30 mm, and a length as

3 of 13 81 82 83 84 well as a width of 10 mm was placed between the high- voltage electrode (upper) and the grounding electrode (lower). The metallic particle was attached to the insulator by a very small amount of epoxy compound. For VIS and crack cells, epoxy plates with a diameter of 80 mm and a thickness of 20 mm were used, both of them were collected from a GIS manufacturer. 85 86 87 88 89 90 91 92 93 94 Figure 2. PD cell for a particle on spacer. 3. Experimental Setup Figure 3 illustrates the experimental setup. A 220 V/50 kv PD-free dry-type transformer was used to apply high voltage to the PD cell. The transformer was immersed in insulation oil to ensure that there is no PD occurring adjacent to the transformer at high voltage. The applied voltage was tested using a high-voltage divider with a ratio of 10,000:1. The artificial PD cell was filled with SF6 gas with a pressure of 0.5 MPa. For accurate measurement, PD signals were detected by a 50Ω non-inductive resistor. A digital storage oscilloscope (DSO) with a sampling rate of 5GS/s and a NI PXI with a sampling rate of 250MS/s were used for signal acquisition and analysis. The input impedance of DSO and PXI were set as 50Ω for impedance matching. 95 96 97 98 99 100 101 102 Figure 3. Experimental setup. 4. Wavelet Transform 4.1. Selection of Mother Wavelet The WT analyzes a signal in both time and frequency domain simultaneously using the scaled and shifted versions of the mother wavelet [23]. Therefore, a proper mother wavelet is of great importance to characterize a given signal. The mother wavelet can be categorized into the orthogonal wavelets (Daubechies (dbx), Coiflets (coifx), Symmlets (symx)) that are suitable for signal de-noising and compression, and the bi-orthogonal wavelets (biorx) that are fit for signal

4 of 13 103 104 de-noising and feature extraction, where X is the order of the wavelet. The higher the order, the smoother the wavelet [12], [24], [25]. Two kinds of mother wavelets were considered in this section. 105 106 107 108 109 110 111 112 113 Figure 4. Typical detected PD pulses. (a) in the void inside spacer (VIS); (b) in the particle on spacer (POS); (c) in the crack. Since the PRPD pattern is the accumulation of single pulses within a certain period of time, the single PD pulses rather than the PD signal detected in a cycle of the applied voltage used to determine the optimal mother wavelet. Single PD pulses were extracted from three types of artificial PD cells. Figure 4 shows the typical detected pulses. The apparent charge values of PD pulses in the VIS, POS, and crack were 17.5 pc, 13.9 pc, and 20.4 pc, respectively [26]. Such pulses were compared with the mother wavelets by calculating their correlation coefficient that is given by = [ ][ ] [ ] (1) [ ]

5 of 13 114 115 116 117 118 119 120 where X(i) and Y(i) are the single PD pulse and the mother wavelet, respectively, and and are their mean values. A larger value of correlation coefficient indicates a higher similarity between these two signals. The calculation results of correlation coefficient are shown in Figure 5. The results show that bior6.8 has the highest similarity with PD pulses occurring in the VIS and crack. In the POS, the mother wavelet that has the highest γ value of 0.421 with discharge pulses was bior2.8, and γ value of bior6.8 with pulses was 0.419. According to the average correlation coefficient value, bior6.8 was selected as the optimal mother wavelet for further investigation 121 122 123 124 125 Figure 5. Correlation coefficient between the single PD pulses and the mother wavelets. 4.2. Determination of Decomposition Level A desirable decomposition level should avoid being redundant and have sufficient resolution to decompose a signal. According to (2), the maximum number of decomposition level Jmax depends on the record length (LR) of signals, which is given by = (2) 126 127 128 129 130 131 132 133 134 135 136 137 where fix specifies the level to be the largest integer no greater than log2lr [24]. In this paper, the record length of PRPD signal was 125k bit, thus the maximum decomposition level was 16. This value was too high to cause a large amount of computation and a waste of time. The decomposition level can be also determined by = (3) 1 where LW is the length of the octave band filter associated with the corresponding mother wavelet [13], [27]. The length of the selected wavelet bior6.8 is 17, as a result, the maximum decomposition level was12. In this paper, the decomposition level was selected as 8, which could characterize the PRPD signal with a sufficient resolution. 4.3. Decomposition of PRPD and Signal Energy After selecting the optimal mother wavelet and determining the decomposition level, the PRPD signals were decomposed by discrete wavelet transform (DWT), using filter banks to calculate the wavelet coefficients. The signal was first down-sampled by a pair of HPF and low pass filter (LPF),

6 of 13 138 139 140 141 142 generating the detail (D) and approximation (A) coefficient, respectively. The approximation component was then fed through another filter pair and down-sampled till the maximum decomposition level. This process is also known as multi-resolution analysis (MRA) [2], [12], [28-30]. Therefore, the result of MRA is the detail component at each level and an approximation component at the highest level. 143 144 145 146 147 148 149 150 Figure 6. Decomposition of the PRPD signal in the VIS into 8 levels. Figure 6 demonstrates the decomposition of the PRPD signal in the VIS into 8 levels, generating the detail components D1-D8 at level 1-8 and the approximation component A8 at the 8th level. It can be seen that the detail components D1-D5, which are in the high frequency range, are associated with PD signal, whereas the components D6-D8 that are in the low frequency range do not contain any PD information since they are related to the background noise. In addition, the approximate component A8 is regarded as capacitive component. The signal energy of detail component at each level was calculated by Signal energy = (4)

7 of 13 151 152 153 154 155 where xi is the signal at each level and N is the signal length. The result is shown in Figure 7. In the detail components, 95.6% of signal energy was distributed in D1-D5, which were expected to be used for signal reconstruction. However, as indicated in Figure 6, there is still background noise interfering with the decomposed components. Therefore, a threshold and a thresholding function were implemented for de-noising the signals in D1-D5. 156 157 158 Figure 7. Signal energies distribution of detail components in the VIS. 4.4. Threshold and Thresholding Function The automatic scale-dependent threshold was used, which is given by = 0.6745 2 (5) 159 160 161 162 where mj are the median values of detail components at each level [13,25]. The intermediate thresholding function is defined as = (6) 0 where δ is a positive integer [31]. The intermediate thresholding function is between the hard and the soft function and provides good continuity at ±λ. Figure 8 shows the result of de-noising D1. 163 Figure 8. De-noising of detail component D1.

8 of 13 164 165 166 167 168 4.5. Signal Reconstruction The decomposed signals were reconstructed using inverse DWT. Based on the above analysis, the de-noised detail components D1-D5 were used for signal reconstruction. The result is illustrated in Figure 9, which led a reduction in noise level of 16.83 db compared with the original detected signal and of -11.43 db relative to the noised D1-D5. 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 Figure 9. Reconstruction of PRPD signal in the VIS using D1-D5. 5. Results and Discussions From the above analysis, the optimal mother wavelet for analyzing PD pulses in spacer was bior6.8, and the decomposition level of 8 was implemented to decompose the PRPD signal. After applying the MRA, it was investigated that the PD events in the VIS were associated with components of D1-D5, which were then de-noised using the automatic scale-dependent threshold and the intermediate thresholding to eliminate the background noise and capacitive disturbance. Finally, PRPD signal was reconstructed with the de-noised D1-D5. To verify the validity of the proposed method, a simulated PRPD signal and the signals detected in the POS and crack were analyzed. 5.1. Simulated PRPD Figure 10(a) shows the simulated PD pulse sequences with different magnitudes and phase distributions. They were mixed with the applied voltage detected at 0.8 time of the discharge inception voltage in the VIS, resulting in a signal-noise ratio (SNR) of -43.08 db. The simulated PRPD signal is demonstrated in Figure 10(b). Its disturbance was eliminated by the proposed wavelet de-noising method and by the HPF with cutoff frequencies of 1 khz, 9 khz, and 100 khz. The results evaluated in terms of correlation coefficient and SNR are shown in Table 1. Figures 10(c) and (d) show the signals de-noised by the filters with the cutoff frequencies of 1 khz and 100 khz, respectively. It is indicated that the filter with a low cutoff frequency could not totally eliminate the disturbance and even that with a high cutoff frequency still could not completely eliminate the background noise. As a result, the correlated coefficients as well as the SNRs between the simulated signal and de-noised signal were very low. Figures 10(e) and (f) illustrate the signals reconstructed using the noisy and de-noised components D1-D5, respectively. Both the capacitive disturbance and background noise were well eliminated after applying the threshold and thresholding function. The signal reconstructed by noisy D1-D5 resulted in a correlation coefficient of 0.141 and a SNR of -16.76 db, whereas that processed by the de-noised D1-D5 led to a correlation coefficient of 0.814 and a SNR of 4.17 db, achieving an improvement in SNR of 47.25 db. Table 1 also gives the results of extraction of PRPD using all of the de-noised detail components. However, an increase in the reconstruction level could not improve the correlation coefficient or SNR, but causes the computational complexity. From

9 of 13 199 200 201 Table 1, the application of WT method may cause reduction in pulse amplitude, but the reduction is much lower compared with using filters. In addition, implementation of filters resulted in a lower SNR. (a) (b) (c) (d) (e) (f) 202 203 Figure 10. Disturbance elimination for simulated PRPD signal. (a) Simulated PD pulse sequences; (b) simulated PRPD; (c) by 1 khz filter; (d) by 100 khz filter; (e) by noisy D1-D5; (f)by de-noisedd1-d5.

10 of 13 204 Table 1. Results of Disturbance Elimination. Method Correlation coefficient SNR Reduction in amplitude [%] 1 khz filter 0.063-23.91 2.69 9 khz filter 0.135-17.35 3.02 100 khz filter 0.134-16.77 5.51 Wavelet, noisy D1-D5 0.141-16.76 0.19 Wavelet, de-noised D1-D5 0.814 4.17 2.30 Wavelet, de-noised D1-D8 0.813 4.09 1.70 205 206 207 208 209 210 5.2. PRPD in the POS and the Crack Figures 11 and 12 demonstrate the results of disturbance elimination for PRPD in the POS and crack, respectively. In the POS, 95.4% of the signal energy was distributed in the components of D1-D5, and the disturbance elimination resulted in a reduction in noise level of 0.46 db. D1-D5 occupied 96.0% of the energy of PRPD signal in the crack, and a reduction in noise level of 17.18 db was achieved. (a) (b) 211 212 Figure 11. Disturbance elimination for PRPD in the POS. (a) Signal energy distribution; (b) extraction of PRPD.

11 of 13 (a) (b) 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 Figure 12. Disturbance elimination for PRPD in the crack. (a) Signal energy distribution; (b) extraction of PRPD. 5. Conclusions In this paper, the WT was used to eliminate the capacitive disturbance from PD signals induced by typical defects in GIS spacers. The optimal mother wavelet was determined as bior6.8 by calculating the correlation coefficients with single PD pulses. The PRPD signals were decomposed into 8 levels using the MRA method. It was revealed that more than 95% of signal energy was distributed in the detail components of D1-D5 whereas the components of D6-D8 and A8, which were related with background noise and capacitive component, respectively, were discarded. Furthermore, components of D1-D5 were de-noised by the automatic scale-dependent threshold and the intermediate thresholding function. The PRPD signals were reconstructed using the de-noised D1-D5. Compared to dealing with filters, the proposed method extracted the PRPD signals with higher correlation coefficient and SNR, resulting in a high sensitivity for PD detection in GIS. Acknowledgments: There were no funding resources. Author Contributions: Guoming Wang and Hong-Keun Ji conceived the experiments and wrote the manuscript. Guoming Wang and Jong-Hyuk Lee performed the experiments and analyzed the data. Gyung-Suk Kil was the supervisor of this work and provided the insight and technical expertise to improve the quality of this paper. Conflicts of Interest: The authors declare no conflict of interest

12 of 13 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 References 1. Bartnikas, R. Partial discharges their mechanism, detection and measurement. IEEE Trans. Dielectr. Electr. Insul. 2002, 9, 763-808, DOI 10. 1109/TDEI.2002.1038663. 2. Liu, M.; Tang, J.; Yao, Q.; Miao, Y. Study on the characteristic decomposition components of DC SF6-insulated equipment under positive DC partial discharge. Energies 2017, 10, 640, doi:10.3390/en10050640. 3. Tang, J.; Yang, X.; Yang, D.; Yao, Q.; Miao, Y.; Zhang, C.; Zeng, F. Using SF6 decomposed component analysis for the diagnosis of partial discharge severity initialted by free metal particle defect. Energies 2017, 10, 1119; doi:10.3390/en10081119. 4. Zhu, M. X.; Zhang, J. N.; Li, Y.; Wei, Y, H.; Xue, J. Y.; Deng, J. B.; Mu, H. B.; Zhang, G. J.; Shao, X. J. Partial discharge signals separation using cummulative energy function and mathematical morphology gradient. IEEE Trans. Dielectr. Electr. Insul. 2015, 23, 482-493, 10.1109/TDEI.2015.005481. 5. Neumann, C.; Rusek, B.; Balzer, G.; Jeromin, I. End of life estimation and optimisation of maintenance of HV switchgear and GIS substations. CIGRE A3 202 2012, 1-12. 6. CIGRE WG, Long-Term Performance of SF6 Insulated Systems, 2002. 7. Ueta, G.; Wada, J.; Okabe, S.; Miyashita, M.; Nishida, C. ; Kamei, M. Insulation performance of three types of micro-defects in inner epoxy insulators. IEEE Trans. Dielectr. Electr. Insul. 2012, 19, 947-954, DOI 10.1109/TDEI.2012.6215098. 8. Braun, J. M.; Ford, G. L.; Fujimoto, N.; Rizzetto, S.; Stone, G. C. Reliability of GIS EHV epoxy insulators: The need and prospects for more stringent acceptance criteria. IEEE Trans. Power Del. 1993, 8, 121-131, DOI 10.1109/61.180327. 9. IEC 62271-203, High-voltage switchgear and controlgear-part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kv, 2003. 10. Yang, L.; Judd, M. D.; Bennoch, C. J. Denoising UHF signal for PD detection in transformers based on wavelet technique. Proceedings of the Electrical Insulation and Dielectric Phenomena, USA, 20 Qct. 2004. 11. Satish, L.; Nazneen, B. Wavelet-based denoising of partial discharge signals buried in excessive noise and interference. IEEE Trans. Dielectr. Electr. Insul. 2003, 10, 354-367, DOI 10.1109/TDEI.2003.1194122. 12. Ma, X; Zhou, C.; Kemp, I. J. Automated wavelet selection and thresholding for PD detection. IEEE Electr. Insul. Mag. 2002, 18, 37-45, DOI 10.1109/57.995398. 13. Zhou, X.; Zhou, C.; Kemp, I. J. An improved methodology for application of wavelet transform to partial discharge measurement denoising. IEEE Trans. Dielectr. Electr. Insul. 2015, 12, 586-594, DOI 10.1109/TDEI.2005.1453464. 14. Zhang, H.; Blackburn, T. R.; Phung B.T.; Sen D. 17. A novel wavelet transform technique for on-line partial discharge measurements part 1: WT de-nosing algorithm. IEEE Trans. Dielectr. Electr. Insul. 2007, 14, 3-14, DOI 10.1109/TDEI.2007.302864. 15. Zhang, H.; Blackburn, T. R.; Phung B.T.; Sen D. 17. A novel wavelet transform technique for on-line partial discharge measurements part 2: On-site nois rejection application. IEEE Trans. Dielectr. Electr. Insul. 2007, 14, 15-22, DOI 10.1109/TDEI.2007.302865. 16. Chang, C. S.; Jin, J.; Chang, C.; Hoshino, T.; Hanai, M.; Kobayashi, N. Separation of corona using wavelet packet transform and neural network for detection of partial discharge in gas-insulated substations. IEEE Trans. Power Del. 2005, 20, 1363-1369, DOI 10.1109/TPWRD.2004.839187. 17. Wu, M.; Cao, H.; Cao, J.; Nguyen, H. L.; Gomes, J. B.; Krishnaswamy, S. P. An overview of state-of-the-art partial discharge analysis techniques for condition monitoring. IEEE Electr. Insul. Mag. 2015, 31, 22-35, DOI 10.1109/MEI.2015.7303259. 18. Ma, H.; Chan, J. C.; Saha, T. K.; Ekanayake, C. Pattern recognition techniques and their applications for automatic classification of artificial partial discharge sources. IEEE Trans. Dielectr. Electr. Insul. 2013, 20, 468-478, DOI 10.1109/TDEI.2013.6508749. 19. CIGRE WG, Risk Assessment on defects in GIS based on PD diagnosis, 2013. 20. Mansour, D. A.; Kojima, H.; Hayakawa, N.; Endo, F.; Okubo, H. Partial discharges and associated mechanisms for micro gap delamination at epoxy spacer in GIS. IEEE Trans. Dielectr. Electr. Insul. 2010, 17, 855-861, DOI 10.1109/TDEI.2010.5492259. 21. Ji, H. X.; Li, C. R.; Ma, G. M.; Pang, Z. K.; Tang, Z. G.; Wen, H.; Cui, B. Y. Partial discharge occurrence induced by crack defect on GIS insulator operated at 1100 kv. IEEE Trans. Dielectr. Electr. Insul. 2016, 23, 2250-2257, DOI 10.1109/TDEI.2016.7556501.

13 of 13 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 22. Wang, G. M.; Jo, H. E.; Kim, S. J.; Kim, S. W.; Kil, G. S. Measurement and analysis of partial discharge in SF6 gas under HVDC. Measurement 2016, 91, 351-359, DOI 10.1016/j.measurement.2016.05.033. 23. Grgic, S.; Grgic, M.; Zovko-Cihlar, B. Performance analysis of image compression using wavelets. IEEE Trans. Ind. Electron. 2001, 48, 682-695, DOI 10.1109/41.925596. 24. Moula, B.; Mekhaldil, A.; Teguar, M.; Haddad, A. Characteristics of discharge on non-uniformly polluted glass surface using a wavelet transform approach. IEEE Trans. Dielectr. Electr. Insul. 2013, 20, 1457-1466, 10.1109/TDEI.2013.6571469. 25. Carvalho, A. T.; Lima, A. C. S.; Cunha, C. F. F. C.; Petraglia, M. Identification of partial discharge immersed in noise in large hydro-generators based on improved wavelet selection methods. Measurement 2015, 75, 122-133, DOI 10.1016/j.measurement.2015.07.050. 26. IEC 60270, High-voltage test techniques-partial discharge measurements, 2000. 27. Ma, X.; Zhou, C.; Kemp, I. J. Interpretation of wavelet analysis and its application in partial discharge detection. IEEE Trans. Dielectr. Electr. Insul. 2002, 9, no. 446-457, DOI 10.1109/TDEI.2002.1007709. 28. Hsieh, M. S.; Tseng, D. C.; Huang, Y. H. Hiding digital watermarks using multiresolution wavelet transform. IEEE Trans. Ind. Electron. 2001, 48, 875-882, DOI 10.1109/41.954550. 29. Li, J.; Jiang, T.; Grzybowski, S.; Cheng, C. Scale dependent wavelet selection for de-noising of partial discharge detection. IEEE Trans. Dielectr. Electr. Insul. 2010, 17, 1705-1714, DOI 10.1109/TDEI.2010.5658220. 30. Shim, I.; Soraghan, J. J.; Siew, W. H. Detection of PD utilizing digital singal processing method. Part 3: open-loop noise reduction. IEEE Electr. Insul. Mag. 2001, 17, 6-13, DOI 10.1109/57.901611. 31. Wang, G. M.; Kim, S. J.; Kil, G. S.; Kim, S. W. Optimization of wavelet and thresholding for partial discharge detection under HVDC. IEEE Trans. Dielectr. Electr. Insul. 2017, 24, 200-208, DOI 10.1109/TDE I.2016.005969.