Lab 1. Objectives. Single Line Diagram. Methodology. Observations. Jon Jawnsy Yu 26 October 2009

Similar documents
Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

Exercises on overhead power lines (and underground cables)

Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian institute of Technology, Kharagpur

R10. III B.Tech. II Semester Supplementary Examinations, January POWER SYSTEM ANALYSIS (Electrical and Electronics Engineering) Time: 3 Hours

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

Chapter 10: Compensation of Power Transmission Systems

Impact of Thyristor Controlled Series Capacitor on Voltage Profile of Transmission Lines using PSAT

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

EE 740 Transmission Lines

Extended Transmission Line Loadability Curve by Including Voltage Stability Constrains

In Class Examples (ICE)

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

Design and Simulation of Passive Filter

Transmission Line Models Part 1

REACTIVE POWER AND VOLTAGE CONTROL ISSUES IN ELECTRIC POWER SYSTEMS

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

ELEMENTS OF FACTS CONTROLLERS

Constant Terminal Voltage. Working Group Meeting 4 19 th September 2014

Delayed Current Zero Crossing Phenomena during Switching of Shunt-Compensated Lines

LARGE-SCALE WIND POWER INTEGRATION, VOLTAGE STABILITY LIMITS AND MODAL ANALYSIS

HVDC CAPACITOR COMMUTATED CONVERTERS IN WEAK NETWORKS GUNNAR PERSSON, VICTOR F LESCALE, ALF PERSSON ABB AB, HVDC SWEDEN

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

Voltage Source Converter Modelling

Implementing Re-Active Power Compensation Technique in Long Transmission System (750 Km) By Using Shunt Facts Control Device with Mat Lab Simlink Tool

A new control scheme for an HVDC transmission link with capacitorcommutated converters having the inverter operating with constant alternating voltage

Analysis of a 405 km transmission line with series compensation

Interline Power Flow Controller: Review Paper

IGEE 402 Power System Analysis. FINAL EXAMINATION Fall 2004

Keywords: Stability, Power transfer, Flexible a.c. transmission system (FACTS), Unified power flow controller (UPFC). IJSER

Optimal Allocation of FACTS Devices in Power Networks Using Imperialist Competitive Algorithm (ICA)

Improving the Transient and Dynamic stability of the Network by Unified Power Flow Controller (UPFC)

Analysis of Power System Oscillation Damping & Voltage Stability Improvement Using SSSC in A Multimachine System

Facilitating Bulk Wind Power Integration Using LCC HVDC

P Shrikant Rao and Indraneel Sen

Influence of Wind Generators in Voltage Dips

REACTIVE POWER TCIPG READING GROUP, OCTOBER 3, 2014 TIM YARDLEY AND PETE SAUER TRUSTWORTHY CYBER INFRASTRUCTURE FOR THE POWER GRID TCIPG.

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

Cork Institute of Technology. Autumn 2008 Electrical Energy Systems (Time: 3 Hours)

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

Determination of Optimal Account and Location of Series Compensation and SVS for an AC Transmission System

1

Optimal Allocation of TCSC Devices Using Genetic Algorithms

Variable Shunt Reactors. Johann Griebichler I EM TR LPT GTC

Increasing Dynamic Stability of the Network Using Unified Power Flow Controller (UPFC)

Line Loadability in Indian Perspective

PV CURVE APPROACH FOR VOLTAGE STABILITY ANALYSIS

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

Optimal Placement of Shunt Connected Facts Device in a Series Compensated Long Transmission Line

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

Address for Correspondence

Optimal Placement of Unified Power Flow Controllers to Improve Dynamic Voltage Stability Using Power System Variable Based Voltage Stability Indices

Voltage Level and Transient Stability Enhancement of a Power System Using STATCOM

Voltage Drop Compensation and Congestion Management by Optimal Placement of UPFC

Dynamic Power Factor Correction Using a STATCOM

MITIGATION OF VOLTAGE SAG AND SWELL FOR POWER QUALITY IMPROVEMENT USING DISTRIBUTED POWER FLOW CONTROLLER

VOLTAGE STABILITY OF THE NORDIC TEST SYSTEM

ANALYTICAL AND SIMULATION RESULTS

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

Standard PRC Coordination of Generating Unit or Plant Voltage Regulating Controls with Generating Unit or Plant Capabilities and Protection

Fatima Michael college of Engineering and Technology

Application of SVCs to Satisfy Reactive Power Needs of Power Systems

Enhancement of Power System Voltage Stability Using SVC and TCSC

Dynamic Series Compensation for the Reinforcement of Network Connections with High Wind Penetration

Design of SVPWM Based Inverter for Mitigation of Harmonics in Power System

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

Form B. Connection Impact Assessment Application Form Distribution System

A Real-Time Platform for Teaching Power System Control Design

Grounding Resistance

BE Semester- VI (Electrical Engineering) Question Bank (E 605 ELECTRICAL POWER SYSTEM - II) Y - Y transformer : 300 MVA, 33Y / 220Y kv, X = 15 %

System Operating Limit Definition and Exceedance Clarification

ECE 692 Advanced Topics on Power System Stability 5 - Voltage Stability

Fault Ride Through Technical Assessment Report Template

COMPARATIVE PERFORMANCE OF SMART WIRES SMARTVALVE WITH EHV SERIES CAPACITOR: IMPLICATIONS FOR SUB-SYNCHRONOUS RESONANCE (SSR)

EL 403 MODEL TEST PAPER - 1 POWER SYSTEMS. Time: Three Hours Maximum Marks: 100

ELEN 460 Computer Laboratory Exercise No: 2 Analysis and Operation of Three-Phase Power Systems

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

COURSE PLANNER Subject: POWER SYSTEM OPERATION AND CONTROL [ ]

Adaptive Settings Of Distance Relay For MOV- Protected Series Compensated Line With Distributed Capacitance Considering Wind Power

A Comprehensive Approach for Sub-Synchronous Resonance Screening Analysis Using Frequency scanning Technique

ECEN 615 Methods of Electric Power Systems Analysis Lecture 8: Advanced Power Flow

UNIVERSITY OF SWAZILAND MAIN EXAMINATION, DECEMBER 2016

Available online at ScienceDirect. Energy Procedia 53 (2014 ) 86 94

EE 340 Transmission Lines

ECE 2006 University of Minnesota Duluth Lab 11. AC Circuits

MINISTERIE VAN ECONOMISCHE ZAKEN GENERAL COST COMPARISON BETWEEN UNDERGROUND CABLES AND O.H. LINE SYSTEMS FOR H.V. TRANSMISSION

Chapter L Power factor correction and harmonic filtering

SIMPLE SOLUTIONS FOR IMPROVING LIFE OF BREAKERS USED IN TRANSMISSION AND DISTRIBUTION SYSTEMS

factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is vo

International Journal of Engineering & Computer Science IJECS-IJENS Vol:12 No:06 14 Smart Power Transmission System Using FACTS Device

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

Design and Control of Small Scale Laboratory Model of a Thyristor Controlled Series Capacitor (TCSC) to Improve System Stability

Overview of Actuation Thrust

Smart Power Transmission System Using FACTS Device

SYNCHRONOUS MACHINES

The Impact of Connecting Distributed Generation to the Distribution System E. V. Mgaya, Z. Müller

Transcription:

Lab 1 Objectives In this lab, our objective is to simulate a simple single machine infinite bus configuration using the PowerWorld Simulator software. We design a local generator system (a synchronous generator) having a nominal generation capacity of 500MW and with no predefined peak generation (that is, the generator is modelled as having infinite generation capability). In this manner, we can explore various phenomena like power transfer, power system stability and the effect of shunt compensation on the midline. We model a 600km span of transmission line with a shunt compensation device installed at the midline (300km from both ends) and determine the stability limit with and without this compensation device enabled. Single Line Diagram Methodology Because PowerWorld does not have a concept of an infinite bus system, we simulate it by using a generator on the slack bus that does not enforce power generation/absorption limits, allowing it to generate or absorb as much power as necessary. Both the local synchronous machine and the infinite bus generator are set to have Automatic Voltage Regulation (AVR) in order to maintain the voltage magnitude at 1.0 per unit. Observations The following table lists some observations without any mid line compensation: Generated Sending Line Voltage Midline Voltage Infinite Bus Voltage 100 MW 1.000 5.06 1.151 2.12 1.000 0 200 MW 1.000 10.25 1.148 4.71 1.000 0 300 MW 1.000 15.50 1.142 7.34 1.000 0 400 MW 1.000 20.86 1.133 10.02 1.000 0 500 MW 1.000 26.39 1.122 12.78 1.000 0 600 MW 1.000 32.16 1.107 15.67 1.000 0 700 MW 1.000 38.27 1.089 18.72 1.000 0 1

800 MW 1.000 44.89 1.065 22.03 1.000 0 900 MW 1.000 52.28 1.034 25.73 1.000 0 1000 MW 1.000 61.02 0.993 30.09 1.000 0 1100 MW 1.000 72.79 0.927 35.98 1.000 0 1167 MW 1.000 90.35 0.812 44.76 1.000 0 1170 MW Catastrophic power system failure All voltage measurements are in per unit with a 1000MVA system base. As indicated from the above chart, local generation of 500MW results in a midline voltage of 1.122 per unit. The challenge, then, is to design a compensation device (a shunt inductor installed at the midline bus) to bring the voltage down to the desired 1.050 per unit value. Using a continuous shunt compensation element (which essentially models the operation of a synchronous condenser) installed at the midline, we can determine the exact amount of reactive power needed to bring the voltage down to our desired value. At 500MW, the condenser behaves as an inductor that consumes 236.6 Mvar of reactive power and the midline voltage is 1.050 as desired. By varying the inductance around the 236 Mvar region, we find that a nominal rating of 214.0 Mvar results in an actual reactive power consumption of 236.0 Mvar, bringing the midline voltage down to 1.050 for 500MW of generation. The following chart shows the system voltages after installation of the shunt inductor: Generated Sending Line Voltage Midline Voltage Infinite Bus Voltage 100 MW 1.000 5.46 1.082 2.55 1.000 0 200 MW 1.000 10.99 1.078 5.31 1.000 0 300 MW 1.000 16.58 1.072 8.11 1.000 0 400 MW 1.000 22.32 1.062 10.98 1.000 0 500 MW 1.000 28.26 1.050 13.94 1.000 0 600 MW 1.000 34.50 1.034 17.07 1.000 0 700 MW 1.000 41.19 1.014 20.41 1.000 0 800 MW 1.000 48.55 0.987 24.09 1.000 0 900 MW 1.000 57.05 0.952 28.34 1.000 0 1000 MW 1.000 67.80 0.899 33.72 1.000 0 1100 MW 1.000 90.88 0.760 45.26 1.000 0 1101 MW Catastrophic power system failure In this case, because of the reactive compensation installed in shunt with the (invisible) line charging capacitances, the reactance of the inductor compensates for a portion of the Ferranti effect and brings 2

the voltage down. However, this results in power system instability earlier than in the uncompensated case, giving a maximum power transfer of only 1100MW. Note from the above that the 1.00pu midline voltage value occurs with a sending side generation of between 700 and 800MW, rather than at the SIL of 1000MW. Graphs The following graph demonstrates the change in the midline voltage with power generated (and therefore transferred) across the lines. Note that the power generated does not equal the actual power transferred across the lines because some of it is lost during transmission (as heating of the lines). Voltage (per unit) 1.20 1.15 1.10 1.05 1.00 0.95 0.90 0.85 0.80 Power vs Mid line Voltage 0 200 400 600 800 1000 1200 Power Generated (MegaWatts) Without Compensation Shunt Inductor The above plot includes information from the first part of the lab (without compensation) as well as the second part, where a fixed inductor is installed at Bus 3. If a synchronous condenser is placed at the midline instead of the fixed inductive element, the midline voltage will remain at the 1.050 setpoint regardless of the other system voltages, due to the reactive power dynamically injected into or removed from the system. Discussion What is the effect of varying power flows on midline voltage? Explain. As we can see from the graph, the mid line voltage is higher than that at both the sending and receiving ends, a phenomenon known as the Ferranti effect. Physically, it is due to the line charging capacitances (line to line and line to ground via the air). As the generated power increases, however, the series inductance of the line begins to play a greater role. When we are transferring power at a rate higher than the SIL limit (we only have two such measurements of this before the system goes unstable), we can see that the uncompensated voltage drops below 1.0 per unit. 3

The voltage is very close to 1.00pu at the Surge Impedance Loading (SIL), which is, in this case, 1000MW. This particular figure is consistent with the given line parameters (500 kv, R=0.028 Ω/km, X L =0.325 Ω /km, B C =5.2 μs/km) according to Appendix H: Transmission Line Parameters. The SIL as indicated on Appendix H is indeed 1000MW. Because it is significantly less expensive both in terms of initial investment and ongoing maintenance costs to install solid state power electronic components on high voltage lines, I simulated a simple fixed reactor (inductor) installed at Bus 3. As we can see from the above graph, the shunt inductor results in a constant per unit voltage drop, but the power vs. mid line voltage relationship remains the same. Was there a limit to the output power of the synchronous generator? Explain. By default, the generator is set to have a generation limit of 1000MW and an unlimited amount of reactive power (both capacitive and inductive). In my experiment, I raised the generation maximum limit to 3000MW to allow me to see what other factors limit the power transferred from the local machine to the infinite bus. With that limit aside, there are other factors limiting the total stability of the system. Most notably, both sides (the machine and the infinite bus) of our system maintained a voltage of 1.0 per unit, which is necessary if there are other loads connected to a nearby local bus. This results in a tightly restricted voltage profile. From the classic power transfer equation, neglecting the resistance on the transmission lines: 1 sin Because the bus voltages must necessarily remain the same, the only thing we can do to increase transferred power from the generator to the infinite bus is to increase the difference in power angles. However, the system is limited because increasing the angle over 90 degrees results in instability. In our simulation, we measured a difference in sending and receiving angles that exceeded 90 degrees and yet remained stable; this is probably due to a flaw in PowerWorld. Even so, note that the angle is still close to 90 degrees. In the compensated configuration, we had a difference of 90.88 between the local system and slack bus before the system became unstable. What happened when that limit was reached? When the power system reached its maximum stability limit, there was a catastrophic failure resulting in a blackout. 4

What effect did the compensator that you designed have on the bus voltages and angles? Jon Jawnsy Yu Because the compensator counteracts the effects of line charging capacitance, it resulted in a lower midline voltage than would have been possible otherwise. However, in order to ensure the same power transfer while having a lower midline voltage, the power angle must increase slightly (per the above power transfer equation). As a result, the system becomes unstable earlier, at 1101MW instead of 1167MW. Conclusions In this computerized simulation, we saw the effect of changing power transfer on the sending, mid line and infinite bus voltages. We performed a load flow study under various load/generation conditions. We saw the effect of compensation installed at the midline bus on power system stability. We also learned how to make use of various features of the PowerWorld Simulator software to model and learn from power systems. 5