HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

Similar documents
FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

RESONANT TRANSFORMER

High Voltage Generation

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY EHV AC AND DC TRANSMISSION

9. How is an electric field is measured?

High Voltage Engineering

ROEVER ENGINEERING COLLEGE ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1402 HIGH VOLTAGE ENGINEERING UNIT I

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

The Hartley Oscillator

, ,54 A

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

Practical Transformer on Load

CONTENTS. 1. Introduction Generating Stations 9 40

The power transformer

3. (a) List out the advantages and disadvantages of HRC fuse (b) Explain fuse Characteristics in detail. [8+8]

Generation of Sub-nanosecond Pulses

Chapter 16: Mutual Inductance

EE High Voltage Engineering UNIT IV - MEASUREMENT OF HIGH VOLTAGES AND HIGH CURRENTS PART-A 1. Mention the techniques used in impulse current

Onsite Mobile AC High Voltage Test System

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

By Gill ( ) PDF created with FinePrint pdffactory trial version

148 Electric Machines

CHAPTER 4. Distribution Transformers

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

Cork Institute of Technology. Autumn 2008 Electrical Energy Systems (Time: 3 Hours)

Oscillators. An oscillator may be described as a source of alternating voltage. It is different than amplifier.

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

International Journal of Advance Research in Engineering, Science & Technology

86 chapter 2 Transformers

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Transformer Factory Testing

Insulation Level and Test Technology of. 1000kV Power Transformer

Module 2 : Current and Voltage Transformers. Lecture 8 : Introduction to VT. Objectives. 8.1 Voltage Transformers 8.1.1Role of Tuning Reactor

Radar. Radio. Electronics. Television. .104f 4E011 UNITED ELECTRONICS LABORATORIES LOUISVILLE

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Power Factor. Power Factor Correction.

Electronic Measurements & Instrumentation. 1. Draw the Maxwell s Bridge Circuit and derives the expression for the unknown element at balance?

Chapter 11. Alternating Current

EE 1402 HIGH VOLTAGE ENGINEERING

Chapter 7 Conclusion 7.1 General

Cornerstone Electronics Technology and Robotics Week 32 Transformers

Welding Transformer: Principle, Requirement and Types

UNIT II MEASUREMENT OF POWER & ENERGY

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

CHAPTER 2. Transformers. Dr Gamal Sowilam

Position Paper on IEEE Task Force on Insulator Icing Test Methods. Item # 5 Power Supply Requirements By Rudi F. Kremer Vice President


Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Lecture 36 Measurements of High Voltages (cont) (Refer Slide Time: 00:14)

Preface...x Chapter 1 Electrical Fundamentals

Reg. No. : BASIC ELECTRICAL TECHNOLOGY (ELE 101)

Accurate Modeling of Core-Type Distribution Transformers for Electromagnetic Transient Studies

Switching Induced Transients:

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI UNIT III TUNED AMPLIFIERS PART A (2 Marks)

PANIMALAR ENGINEERING COLLEGE Department of Electrical and Electronics Engineering

Design and Simulation of Passive Filter

DIFFERENCE BETWEEN SWITCHING OF MOTORS & GENERATORS WITH VACUUM TECHNOLOGY

Conventional Paper-II-2011 Part-1A

BY V.BALAJI, AP/EEE, DCE

Basic Principles and Operation of Transformer

HV AC TESTING OF SUPER-LONG CABLES

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

SECTION 4 TRANSFORMERS. Yilu (Ellen) Liu. Associate Professor Electrical Engineering Department Virginia Tech University

Transformers. Dr. Gamal Sowilam

Prediction of Transient Transfer Functions at Cable-Transformer Interfaces

Realisation of the galvanic isolation in customer-end DC to AC inverters for the LVDC distribution

~=E.i!=h. Pre-certification Transformers

thepower to protect the power to protect i-gard LITERATURE Low and medium voltage

VARIABLE FREQUENCY RESONANT TEST SYSTEM

MAHALAKSHMI ENGINEERING COLLEGE

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (EE, EN, EC, CE)] QUIZ TEST-3 (Session: ) Time: 1 Hour ELECTRICAL ENGINEE

Transformer Protection

Electrical Machines I : Transformers

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment)

BE Semester- VI (Electrical Engineering) Question Bank (E 605 ELECTRICAL POWER SYSTEM - II) Y - Y transformer : 300 MVA, 33Y / 220Y kv, X = 15 %

An induced emf is the negative of a changing magnetic field. Similarly, a self-induced emf would be found by

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Feedback Amplifier & Oscillators

Transformer & Induction M/C

Properties of Inductor and Applications

AUTO-TRANSFORMER. This is having only one winding; part of this winding is common to both primary and secondary.

PROBLEMS on Transformers

SRI VIDYA COLLEGE OF ENGG AND TECH

I p = V s = N s I s V p N p

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

IOCL Electrical Engineering Technical Paper

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

2. Current interruption transients

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6

Power Supplies in Accelerators

Converters for Cycling Machines

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

Transcription:

LECTURER-24 GENERATION OF HIGH ALTERNATING VOLTAGES When test voltage requirements are less than about 300kV, a single transformer can be used for test purposes. The impedance of the transformer should be generally less than 5% and must be capable of giving the short circuit current for one minute or more depending on the design. In addition to the normal windings, namely, the low voltage windings, a third windings known as meter windings is provided to measure the output voltage. For higher voltage requirements, a single unit construction becomes difficult and costly due to insulation problems. Moreover, transportation and erection of large transformers become difficult. These drawbacks are by series connection or cascading of the several identical units of transformers, where in the high voltage windings of all the units effectively come in series.

1.Cascade Transformers The above Figure shows the cascade transformer units in which the first transformer is at the ground potential along with its tank. The second transformer is kept on insulators and maintained at a potential of V2, the output voltage of the first unit above the ground. The high voltage winding of the first unit is connected to the tank of the second unit. The low voltage winding of this unit is supplied from the excitation winding of the first transformer, which is in series with the high voltage winding of the first transformer at its high voltage end. The rating of the excitation windings is almost identical to that of the primary or the low or the low voltage winding. The high voltage connection from the first transformer winding and the excitation winding terminal are taken through a bushing to the second transformer. In a similar manner, the third transformer is kept on insulators above the ground at a potential of 2V2 and is supplied likewise from the second transformer. The number of stages in this type of arrangement are usually two four, but very often, three stages are adapted to facilitate a three-phase operation so that3v 2 can be obtained between the lines. Supply to the units can be obtained from a motor-generator set or through an induction regulstor for variation of the output voltage. The rating of the primary or the low voltage windings is usually 230 or 400 V for small units up to 100 kva. For larger outputs the rating of the low voltage winding may be 3.3 kv, 6.6kV or 11 kv.

In the above figure a second scheme for providing the excitation to the second and the third stages is shown. Isolating transformers I s1, I s2 and I s3 are 1:1 ratio transformers and are meant for supplying the excitation for the second and the third stages at their tank potentials. Power supply to the isolating transformers is also fed from the same a.c. input. This scheme is expensive and requires more space. The advantage of this scheme is that the natural cooling is sufficient and the transformers are light and compact. Transportation and assembly is easy. Also the construction is identical for isolating transformers and the high voltage cascade units. Three phase connection in delta or star is possible for three units. Testing transformers of ratings up to 10 MVA are cascade connection to give high voltages up to 2.25 MV are available for both indoor and outdoor applications. In order to reduce the size and cost of the insulation, sometimes transformers with a centre tap on high voltage windings earthed or connected to the tank are used. This connection results in a cheaper construction, and the high voltage insulation now needs to be designed for V2 / 2, that of second transformer at3v 2 / 2, and that of the third transformer at 5V2 / 2.

All the cascade transformer units which are meant for the supply of excitation to the next stage have large leakage between the primary (or the low voltage winding) and the excitation windings. Hence, they are invariably provided with compensating windings. 2.Resonant Transformers The equivalent circuit of a high voltage testing transformer consist of the leakage reactances of the windings, the windings resistances, the magnetizing reactance, and the shunt capacitance across the output terminal due to the bushing of the high voltage terminal and also that of the test object. This is shown in Fig. bellow. It may be seen that it is possible to have series resonance at power frequency With this condition, the current in the tests object is very large and is limited only by the resistance of the circuit. The waveform of the voltage across the test object will be purely sinusoidal. The magnitude of the voltage across the capacitance C of the test object will be where R is the total series resistances of the circuit. The factor C X /R is the Q factor of the circuit and gives the magnitude of the voltage multiplication across the test object under resonance conditions. Therefore, the input voltage required for excitation is reduced by a factor 1/Q, and the output kva required is also reduced by a factor 1/Q. the secondary power factor of the circuit is unity. This principle is utilized in testing at very high voltage and on occasions requiring large current outputs such as cable testing, dielectric loss measurements, partial discharge measurements, etc. a transformer with 50 to 100 kv voltage rating and a relatively large current rating is connected

together with an additional choke, if necessary. The test condition is set such that,c where L is the total equivalent leakage inductance of the transformer including its regulating transformer. The chief advantages of this principle are: a) it gives an output of pure sine wave, b) power requirements are less (5 to 10% of total kva required), c) no high power arcing and heavy current surges occur if the test object failed, as resonance ceases at the failure of the test object, d) cascading is also possible for very high voltage, e) simple and compact test arrangement, and f) no repeated flashovers occur in case of partial failures of the test object and insulation recovery. It can be shown that the supply source takes Q number of cycles at least to charge the test specimen to the full voltage. The disadvantages are the requirements of additional variable chokes capable of withstanding the full test voltage and the full current rating. 3 Generation of High Frequency a.c. High Voltages High frequency high voltage are required for rectifier d.c. power supplies as discussed. Also, for testing electrical apparatus for switching surges, high frequency high voltage damped oscillators are needed which need high voltage high frequency transformers. The advantages of these high frequency transformers are: i) the absence of iron core in transformers and hence saving in cost and size, ii) pure since wave output, iii) slow build-up of voltage over a cycles and hence no damage due to switching surges, and iv) uniform distribution of voltage across the winding coils due to subdivision of coil stack into a number of units. The commonly used high frequency resonant transformer is the Tesla coil, which is a doubly tuned resonant circuit shown schematically in Fig bellow

The primary voltage rating is 10 kv and the secondary may be rated to as high as 500 to 1000 kv. The primary is fed form a.d.c. or a.c. supply through the condenserc 1. A spark gap G connected across the primary is triggered at the desired voltage V1 which induces a high self excitation in the secondary. The primary and the secondary windings (L1 and L 2 ) are wound on an insulated former with no core (air cored) and are immersed in oil. The windings are tuned to a frequency of 10 to 100kHz by means of the condensers C1 and C2.The output voltage V2 is a function of the parameters L1, L2, C1, C2, and the mutual inductances M. usually, the windings resistance will be small and contribute only for damping of the oscillations. The analysis of the output waveform can be done in a simple manner neglecting the winding resistance. Let the condenser C1 be charged to a voltage V 1 when the spark gap is triggered. Let a current i1 flow through the primary windings L1 and produce a current i2 through L2 and C2. Then, where I1 and I2 are the Laplace trans formed values of i1 and i2. The output voltage V across the condunser C 2 is

The peak amplitude of the secondary voltage V2 can be expresses as, A more simplified analysis for the Tesla coil may be presented by considering that the energy stored in the primary circuit in the capacitance C1 is transferred to C2 via the magnetic coupling. If W1 is the energy stored in C1 and W2 is the energy transferred to C2 and if efficiency of the transformer is then It can be shown that if the coefficient of coupling K is large oscillation frequency is less, and for large values of the winding resistance and K, the waveform may become a unidirectional impulse. This is shown in the next sections while dealing with the generation of switching surges.