Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe

Similar documents
PLASTIC PIPE DEFECT DETECTION USING NONLINEAR ACOUSTIC MODULATION

Multiple crack detection of pipes using PZT-based guided waves

vibro-acoustic modulation

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

High Frequency Acoustic Signal Analysis for Internal Surface Pipe Roughness Classification

New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

The influence of gouge defects on failure pressure of steel pipes

Long Range Ultrasonic Testing - Case Studies

Enhanced Resonant Inspection Using Component Weight Compensation. Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241

The Development of Laser Ultrasonic Visualization Equipment and its Application in Nondestructive Inspection

Corrosion Assessment of Offshore Oil Pipeline Based on Ultrasonic. Technique

Generation Laser Scanning Method for Visualizing Ultrasonic Waves Propagating on a 3-D Object

Corrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing

INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING

The Application of TOFD Technique on the Large Pressure Vessel

Ultrasonic sensors in subsea oil & gas production current use and opportunities

NONDESTRUCTIVE EVALUATION OF CLOSED CRACKS USING AN ULTRASONIC TRANSIT TIMING METHOD J. Takatsubo 1, H. Tsuda 1, B. Wang 1

Experimental investigation of crack in aluminum cantilever beam using vibration monitoring technique

WAVE PROPAGATION SCATTERING DUE TO DEFECTS ON THIN COMPOSITE PLATES. Queensland, Toowoomba QLD 4350, Australia

Overview. Corrosion detection improvement of oil and gas pipelines with industrial radiography method by using image processing.

Modelling of Pulsed Eddy Current Testing of wall thinning of carbon steel pipes through insulation and cladding

Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor

Research and Application of Pulsed Eddy Current Testing for Ferromagnetic Metallic Components

THE INFLUENCE OF GOUGE DEFECTS ON FAILURE PRESSURE OF STEEL PIPES

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

DETECTION AND SIZING OF SHORT FATIGUE CRACKS EMANATING FROM RIVET HOLES O. Kwon 1 and J.C. Kim 1 1 Inha University, Inchon, Korea

DATA ANALYSIS FOR VALVE LEAK DETECTION OF NUCLEAR POWER PLANT SAFETY CRITICAL COMPONENTS

Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures

Detectability of kissing bonds using the non-linear high frequency transmission technique

Introduction To NDT. BY: Omid HEIDARY

EMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)

Experimental Vibration-based Damage Detection in Aluminum Plates and Blocks Using Acoustic Emission Responses

Control Valve Fault Detection by Acoustic Emission: Data Collection Method

Paper Title: FIELD MONITORING OF FATIGUE CRACK ON HIGHWAY STEEL I- GIRDER BRIDGE

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

IMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES USING REMOTE FIELD EDDY CURRENT

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

A Novel Self Calibrating Pulsed Eddy Current Probe for Defect Detection in Pipework

FATIGUE CRACK DETECTION IN METALLIC MEMBERS USING SPECTRAL

Research on An Inspection Method for De-bond Defects in Aluminum. Skin-Honeycomb Core Sandwich Structure with Guided Waves

Feasibility Study of Using Acoustic Signal for Material Identification in Underwater Application Using a Single Transceiver

Hardware Development of Reflection Mode Ultrasonic Tomography System for Monitoring Flaws on Pipeline

Fretting Fatigue of Slot-dovetails in Turbo-generator Rotor

Application of Guided Wave Technology to Tube Inspection

Quasi-Rayleigh Waves in Butt-Welded Thick Steel Plate

Spectral Distance Amplitude Control for Ultrasonic Inspection of Composite Components

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

EMBEDDED NON-DESTRUCTIVE EVALUATION FOR DAMAGE DETECTION USING PIEZOELECTRIC WAFER ACTIVE SENSORS

Properties of Interdigital Transducers for Lamb-Wave Based SHM Systems

An instrument for detecting corrosion in anchorage zones of bridge cables using guided waves

Reference wavelets used for deconvolution of ultrasonic time-of-flight diffraction (ToFD) signals

SPARSE ARRAY TOMOGRAPHY SYSTEM FOR CORROSION EXTENT MONITORING H. Bian, H. Gao, J. Rose Pennsylvania State University, University Park, PA, USA

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho

A STUDY ON NON-CONTACT ULTRASONIC TECHNIQUE FOR ON-LINE INSPECTION OF CFRP

Pipeline Technology Conference 2010

Study on monitoring technology of aircraft engine based on vibration and oil

Magnetic Eddy Current (MEC) Inspection Technique

Signal Processing in an Eddy Current Non-Destructive Testing System

GUIDED WAVES FOR DAMAGE MONITORING IN PLATES FOR NOTCH DEFECTS

NDT OF FREEZE-THAW DAMAGED CONCRETE SPECIMENS BY NONLINEAR ACOUSTIC SPECTROSCOPY METHOD

Investigation on Acoustic Emission of Hydrogen Induced Cracking for Carbon Steel Used in Pressure Vessel

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK

Title: Reference-free Structural Health Monitoring for Detecting Delamination in Composite Plates

SonaFlex. Set of Portable Multifunctional Equipment for Non-contact Ultrasonic Examination of Materials

Ultrasonic Guided Waves for NDT and SHM

Rock Bolt Inspection by Means of RBT Instrument

Excitation and reception of pure shear horizontal waves by

ASSESSMENT OF REINFORCEMENT CORROSION USING NONLINEAR ULTRASONIC SPECTROSCOPY

Research Article An Investigation of Structural Damage Location Based on Ultrasonic Excitation-Fiber Bragg Grating Detection

430. The Research System for Vibration Analysis in Domestic Installation Pipes

An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array

D DAVID PUBLISHING. Eddy Current Test for Detection of Foreign Material using Rotating Probe. 2. Theory. 1. Introduction

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement

Quantitative Crack Depth Study in Homogeneous Plates Using Simulated Lamb Waves.

Sonic Distance Sensors

DAMAGE DETECTION IN PLATE STRUCTURES USING SPARSE ULTRASONIC TRANSDUCER ARRAYS AND ACOUSTIC WAVEFIELD IMAGING

Study on Propagation Characteristics of Ultrasonic Guided Wave for EMAT Sensor

Experimental and theoretical investigation of edge waves propagation and scattering in a thick plate with surface-breaking crack-like defect

Guided Wave in Engineering Structures Using Non-Contact Electromagnetic Acoustic Transducers A Numerical Approach for the Technique Optimisation.

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA

NDT-PRO Services expands service offering

NDT KONFERANSEN ZENOVIEA VOROSCIUC

Detecting 1 st and 2 nd Layer Simulated Cracks in Aircraft Wing Spanwise Splice Standards Using Remote-Field Eddy Current Technique

Objectives Demonstrate new sensing techniques to improve performance of CA refrigeration systems.

Dr. P. SREENIVASULU REDDY 2

ULTRASOUND IN CFRP DETECTED BY ADVANCED OPTICAL FIBER SENSOR FOR COMPOSITE STRUCTURAL HEALTH MONITORING

Curved arrays for improved horizontal sizing in small pipe welds

Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection

STUDY OF FAULT DIAGNOSIS ON INNER SURFACE OF OUTER RACE OF ROLLER BEARING USING ACOUSTIC EMISSION

Fault detection in small diameter pipes using ultrasonic guided wave technology

Developer Techniques Sessions

DEVELOPMENT OF STABILIZED AND HIGH SENSITIVE OPTICAL FI- BER ACOUSTIC EMISSION SYSTEM AND ITS APPLICATION

Application Research on Hydraulic Coke Cutting Monitoring System Based on Optical Fiber Sensing Technology

Testing of Buried Pipelines Using Guided Waves

In-Situ Damage Detection of Composites Structures using Lamb Wave Methods

Development of Automatic Neural Network Classifier of Defects Detected by Ultrasonic Means

Developments in Ultrasonic Guided Wave Inspection

Ultrasonic Imaging of Tight Crack Surfaces by Backscattered Transverse Wave with a Focused Transducer

Transducer degradation and high amplitude behavior of broadband piezoelectric stack transducer for vibrothermography

Transcription:

Ultrasonic Guided Wave Method For Crack Detection In Buried Plastic Pipe Wan Sofian Wan Hamat 1,a, Mohd Fairusham Ghazali 1 and Gigih Priyandoko 1 1 Faculty of Mechanical Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia Abstract. Plastic pipe are widely used in many fields for the fluid or gaseous product conveyance but basic components of a plastic material made it very sensitive to damage, which requires techniques for detecting damage reliable and efficient. Ultrasonic guided wave is a sensitive method based on propagation of low-frequency excitation in solid structures for damage detection. Ultrasonic guided wave method are performed to investigate the effect of crack to the frequency signal using Fast Fourier Transform (FFT) analysis. This paper researched to determine performance of ultrasonic guided wave method in order to detect crack in buried pipeline. It was found that for an uncrack pipe, FFT analysis shows one peak which is the operating frequency by the piezoelectric actuator itself while the FFT analysis for single cracked pipe shows two peak which is the operating frequency by the piezoelectric actuator itself and the resultant frequency from the crack. For multi cracked pipe, the frequency signal shows more than two peak depend the number of crack. The results presented here may facilitate improvements in the accuracy and precision of pipeline crack detection. 1 Introduction Recent developments in pipelines systems have heightened the need for study about the pipe defect detection using ultrasonic guided wave method. In recent years, several studies have focused on defect detection in pipeline systems because it is very important used extensively all over the world to transport and distribute natural gas, crude oil, water, and other easy-flowing products. Indeed, in the process of continuous transportation, gas pipeline leakage cannot be avoided because of the corrosion of pipe walls [1], third-party interference [2], aging of the pipes [3], and so on. Therefore, leakage detection and localization is one of the paramount concerns of pipeline operators and researchers all over the world. Many researchers have argued that Non-destructive testing (NDT) is a wide group of analysis techniques used in science and industry to evaluate the properties of a material, component or system without causing damage. NDT is a highly valuable technique that can save both money and time in product evaluation, troubleshooting, and research. Coon NDT methods include ultrasonic, magnetic-particle, liquid penetrant, radiographic, remote visual inspection (RVI), eddy-current testing, and low coherence interferometry. According to K Haller (2007), damage can be monitored in many ways [4]. The choice of composite materials is no longer restricted to specific applications. In other fields, using these new materials as innovation tool and performance rising of their products such civil engineering. It is important first to have the best possible knowledge about these materials in somehow to monitor any changes in these properties and consequently their influence on the structure behavior [5, 6]. Plastic pipe is a good material because high resistance, light, cheap and longer life span. Therefore, plastic pipes usually are used to transport gas, water and chemicals. In general, plastic pipes are widely used over metal or concrete pipes. Due to the material being iune to water corrosion and highly resistant to fouling, it is also being considered as a replacement for stainless steel in safety-critical applications in nuclear power stations [7]. According to Carvalho et al. (2008), researchers have spent an ample amount of time, investigations and researched on non-destructive test techniques. As much as during the setting up phase during their useful life, these techniques are used as a method to asses engineering structures and system [8]. Crack inspection is a valuable non-destructive test (NDT) method in many industries. Crack inspection method is useful, which often exhibit complex geometries, are exposed to high thermal and mechanical loads and are expected to satisfy a Corresponding author: w_sofian45@yahoo.com The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Coons Attribution License 4.0 (http://creativecoons.org/licenses/by/4.0/).

strict safety requirements. Lately, there is a need to expand a powerful crack defect detection methods [9]. Early detection of damage is not necessarily visible from the external face and even when it is the case of visual inspection does not realize its case state. In order of reliable and efficient use, these new materials, the development of a measurement system that can answer the following two questions of primary importance is required whether it could be measured directly in NDT and reliable mechanical properties of a composite structure. Is it possible to detect damage as quick as possible in order to monitor, evaluate and repair if necessary the structure [10]. Piezoelectric materials constitute another important research topic with respect to Structural Health Monitoring (SHM) applications. Piezoelectric transducers are often used to excite and receive ultrasonic guided waves due to their low costs and an easy integration into existing structures. This research area offers a wide variety of contributions [11, 12]. Although there were many researches about ultrasonic guided wave method to detect pipe damage, few of them focused on result obtained only for this method. So it is necessary to do deep research on the design and develop an experimental test rig for pipe defect detection to run easily, faster, efficient and cost-effective. 2 Experimental Set Up Design of Experiment The aim of this paper is to determine the performance of ultrasonic guided wave method in detecting cracks in the pipeline system using an experiment. An experimental test rig design and develop for buried plastic pipe defect detection to prevent the leakage in the piping system. All the experiments were conducted on plastic pipe specimens with piezoelectric wafer actuator (PSI-5A4E) and accelerometer mounted on the surface of each pipe. Piezoelectric wafer actuator as a transmitter and the accelerometer as a receiver. A National Instruments Data Acquisition system (NI USB-4431) was used to drive the transmitter and to record data and waveform at the receiver. The specifications of the experimental specimens are given in Table 1. Table 1. Specification of the experimental specimens Exp. No. ( a OD: outside diameter; b WT: wall thickness; c Dist: distance between the transmitter and the receiver). Experimental Procedure Buried Plastic Pipe Specimens Dimensions [] Length OD a WT b 1.1 600 40 2 Sensors & Transducers Specifications Dist. c [] 300 1.2 600 40 2 Difference distance 1.3 1300 40 2 between the 600 1.4 1300 40 2 transmitter and the 900 1.5 1300 40 2 receiver. 1200 2.0 600 40 2 1 lateral saw cut. 3.0 600 40 2 2 lateral saw cut. This experiment carried out a few times to make sure a more accurate result is obtained. First, the experiment will be carried out on an uncrack specimen. Data will be collected and analyzed. Next, the experiment will be carried out on a specimen with a single crack. Lastly, the experiment will be carried out on a specimen with multi cracks. All the data were collected and analyzed. From the data collected, we can compare the result of all the three specimen. Piezoelectric wafer actuator (PSI-5A4E) was used to excite the specimen. By placing the specimen on the foams and using a significantly smaller size of wafer actuator, this is the best compromise method for diagnosing defects. Nonlinear effects and noise effects from the attachment of the mechanical shaker or rigid supports can be prevented by using this method. A comparison was made between this method and the former method that using a mechanical shaker for the excitation. Although the maximum excitation level from the piezoelectric actuator is relatively lower than with the mechanical shaker, results from the latter method also showed a good signature of the sidebands effect against the defects [10, 13]. The experiment for uncrack specimen begin with distance between piezoelectric wafer actuator as a transmitter and accelerometer as a receiver is 300. The frequencies applied to the specimen are Hz, 3000 Hz, 6000 Hz, and 9000 Hz. After the data is collected and recorded, the experiment is repeated with different value of distance 2

between transmitter and receiver. This process is repeated with 600, 900 and 1200 distance between transmitter and receiver. The relationship between the distance and amplitude for frequency signal can be identify from results obtained for this experiments. The experiment for single crack specimen and multi cracks specimen was performed on a pipe with length 600 which the piezoelectric wafer actuator and accelerometer are placed on the surface of the pipe where the distance between each other is. Figure 1 illustrates the specimen for (a) uncrack specimen, (b) single crack specimen and (c) multi cracks specimen. Lateral saw cut made as a crack shown at Figure 1(b) and Figure 1(c). The crack made at the middle of this distance (250 ) for single crack specimen; see Figure 1(b). For multi cracks specimen, two crack made at distance 165 from piezoelectric stack actuator and 165 from accelerometer; see Figure 1(c). Figure 2(a). Full view for the experimental setup Figure 2(b). Buried pipe specimen Figure 1. Piezoelectric wafer actuator and accelerometer placed on the surface of three pipe specimens. (a) Uncrack specimen; (b) Single crack specimen; (c) Multi cracks specimen. The data collected will undergo analysis using the Dasylab and Matlab software. The data will also undergo amplification and filtering module. The amplification module is to amplify the data collected and filtering of the data is extremely vital in obtaining an accurate time base response graph. The plastic pipe will be attached the sensors and then it will be connected to Data Acquisition (DAQ) system. The Data Acquisition system will be synchronized to the Dasylab software using the NI-MAX software. The system will be configured to analyze the voltage as the sensor medium. The accelerometer will be controlled using the Dasylab software. After collecting the raw data, analyzing data were done by using Matlab software. The experiments setup for this study are illustrated in Figure 2(a) and Figure 2(b). 3 Results and Discussion The relationship between distance and amplitude The experiment results will be shown in the form of graph for Fast Fourier Transform (FFT) analysis which is produced by using Matlab software. Table 2 shows the comparison of amplitude value for each of the spectrum at different distance between sensor and actuator for uncrack specimen. The value of the amplitude decreases as the distance between actuator and sensor increases. This can be deduced that the waves tend to dissipate more when the distance traveled by the wave is increased. So, the waves will become weaker when the distance is increased and this explained the reason for the value of amplitude decreases when the distance increases. The amplitude value is inversely proportional with distance between sensor and actuator. 3

Table 2. Comparison of amplitude value for each spectrum at different distance and frequency applied Frequency (Hz) 300 Amplitude 600 900 1200 3000 0.13267 0.06291 0.05385 0.02730 6000 0.09017 0.04210 0.02834 0.01482 9000 0.08762 0.00753 0.00376 0.00135 From the FFT analysis graph in Figure 3, Figure 4, and Figure 5, it could be clearly seen that the amplitude of the frequency response signal decreases as the distance between the piezoelectric wafer actuator and accelerometer increases. For 3000 Hz, the frequency signal response amplitude is 0.13267 at 300 followed by 0.06291 at 600, 0.05385 at 900 and 0.02730 at 1200 ; see Figure 3. For 6000 Hz, the frequency signal response amplitude is 0.09017 at 300 followed by 0.04210 at 600, 0.02834 at 900 and 0.01482 at 1200 ; see Figure 4. For 9000 Hz,, the frequency signal response amplitude is 0.08762 at 300 followed by 0.00753 at 600, 0.00376 at 900 and 0.00135 at 1200 ; see Figure 5. All the frequencies show that that the frequency signal amplitude are the highest at the shortest distance. This shows that it is capable of travelling at a short distance. Figure 3. Results obtained for 3000 Hz frequency applied to the 300, 600, 900 1200 of uncrack specimen. In general, the frequency signal amplitude decreases in all samples due to the attenuation inside the testing medium as the distance from the source is increased too. It is clear that the attenuation increases with increasing distance. The transmitted signal is attenuated by the transmission medium which is the time required by the signal to reach the sensor point. This transmission makes some turbulence in the transmission medium and such turbulence may remain exist over this period of time. When transmission frequency increases, the transmission medium will contain effects of consecutive signals and constructive and destructive interferences would take place. Accordingly, the accelerometer would receive transmitted signals at a higher frequency and if the accelerometer needs longer time to distinguish the received signals from each other, then higher frequency may cause destructive interference at the sensor, which in turn affects the final recorded signal amplitude. Comparing the results for uncrack and crack specimen. Figure 4. Results obtained for 6000 Hz frequency applied to the 300, 600, 900 1200 of uncrack specimen. Figure 6. FFT analysis graph for (a) uncrack specimen, (b) single crack specimen, (c) multi cracks specimen. Figure 5. Results obtained for 9000 Hz frequency applied to the 300, 600, 900 1200 of uncrack specimen. 4

Figure 6(a) shows the FFT analysis graph of the results obtained for an uncrack specimen. From the results obtained, the FFT analysis graph shows one peak which is the operating frequency by the piezoelectric actuator itself. Figure 6(b) shows the FFT analysis graph for single crack specimen. The graph FFT analysis shows two peak which is the operating frequency by the piezoelectric wafer actuator itself and the resultant frequency from the crack. Figure 6(c) shows FFT analysis graph for multi cracks specimen. From the frequency signal obtained, the data shows more than two peaks which one peak is the operating frequency by the piezoelectric actuator itself and other peaks is the resultant frequency from the cracks. Accelerometer has its own area of influence characterized by a sensing radius and the corresponding circle. Damage within the area of influence of the sensor is highly sensitive as it creates higher disturbances than the damage outside the area of influence. An exciting vibration at creates appreciable stress in the material affecting interfaces at all scales of damage. An ultrasound probe wave traveling through these interfaces is modulated due to vibration-induced changes in the interface condition and, as a result, additional spectral components appear at the frequencies. These new frequency components indicate that a flaw or crack is present. 4 Conclusions This study set out to determine the performance of ultrasonic guided wave method in detecting cracks in the pipeline system using an experiment. An experimental test rig design and develop for buried plastic pipe defect detection to prevent the leakage in the piping system. The findings of this study suggest that detecting the defects in buried pipe using ultrasonic guided wave method is faster, efficient and cost-effective. From the data collected and analyzed, uncrack and crack specimen can be distinguished more obviously in a short time. The FFT analysis graph clearly shows only one peak for the uncrack specimen and two peak for the single crack specimen. There are more than two peak for the multi cracks specimen. Further investigation and experimentation for defect detection in pipe is strongly recoended. A number of possible future studies using the same experimental set up are apparent. It would be interesting to assess the effects of ultrasonic guided wave detecting the defect in pipe. Acknowledgements The work presented in this paper was supported by Universiti Malaysia Pahang (UMP) through the RDU Grant research project (RDU130111) lead by Dr. Mohd Fairusham Bin Ghazali. The authors are grateful to the Universiti Malaysia Pahang and Education Sponsorship Division, Ministry Of Education Malaysia for supporting the present study. References 1. Edalati K, R.N., Kermani A, Seidi M, Movafeghi A, The use of radiography for thickness measurement and corrosion monitoring in pipes. International Journal of Pressure Vessels and Piping, 2006. 83: p. 736-741. 2. Liang, W., et al., Assessing and classifying risk of pipeline third-party interference based on fault tree and SOM. Engineering Applications of Artificial Intelligence, 2012. 25(3): p. 594-608. 3. Vargas-Arista, B., J.M. Hallen, and A. Albiter, Effect of artificial aging on the microstructure of weldment on API 5L X-52 steel pipe. Materials Characterization, 2007. 58(8 9): p. 721-729. 4. Haller, K., Nonlinear Acoustics Applied to NonDestructive Testing. 1st ed. 2007, Department of Mechanical Engineering, School of Engineering Blekinge Institute of Technology, Sweden: Blekinge Institute of Technology. 5. Lakhdar, M., et al., Damages Detection in a Composite Structure by Vibration Analysis. Energy Procedia, 2013. 36: p. 888-897. 6. Xu, H.L.H., Damage Detection for Structural Health Monitoring Using Ultrasonic Guided Waves, in School of Energy, Power and Mechanical Engineering. 2013, North China Electric Power University: Beijing, China. 7. Assunção E, C.L., Hagglund F, Troughton M, & Spicer M, Advanced NDT techniques for plastic pipeline inspection. 2013, European Union under the Framework-7 TestPEP: EWF, Oeiras, Portugal. 8. Zenzinger, G., et al., Crack Detection Using EddyTherm. AIP Conference Proceedings, 2005. 760(1): p. 1646-1653. 9. Carvalho, A.A., et al., Reliability of non-destructive test techniques in the inspection of pipelines used in the oil industry. International Journal of Pressure Vessels and Piping, 2008. 85(11): p. 745-751. 10. Jenal, R., Fatigue crack detection using nonlinear acoustic Analysis of vibro acoustic modulations., in Department of Mechanical Engineering. 2010, The University of Sheffield, United Kingdom. 11. C. Willberg, S.D., J.M. Vivar-Perez, Z.A.B. Ahmad, Simulation Methods for Guided Wave-Based Structural Health Monitoring: A Review. Applied Mechanics Reviews. January 2015. Vol. 67/010803-1. 12. Ahmed, M.N., A Study of Guided Ultrasonic Wave Propagation Characteristics in Thin Aluminum Plate for Damage Detection, in Graduate Faculty. 2014, The University of Toledo: United States. 13. Shi Yan, J.Q., Nai-Zhi Zhao, Yang Cheng and Sheng-Wenjun Qi, Multiple Crack Detection of Pipes Using PZT-based Guided Waves, in School of Civil Engineering. 2014, Shenyang Jianzhu University, Shenyang Liaoning 110168, China. 5