SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and output signals, respectively to amplify and/or change the signal level or type (current or voltage) of the input signals. The amplifi er fulfi ls all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 00 resp. EN 6 00). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 900. The device has two channels and provides two independent isolating amplifi ers in an extremely small space. The user has a wide choice of input and output ranges and can set the desired one with the aid of soldered jumpers and potentiometers. A version with one input and two outputs is available that enables two electrically insulated outputs to be obtained from a single input signal. Fig.. Isolating amplifi er SINEAX TV 808- in housing S7 clipped onto a top-hat rail or screw hole mounting brackets pulled out. Variants 5 standard input and output combinations selected by soldered jumpers User-specific input and/or output ranges Isolating amplifier with one input and two electrically insulated outputs Power supply 4 60 V DC/AC or 85 30 V DC/AC Please request our data sheet TV 808- Le for single-channel versions. Features / Benefits Electric insulation between inputs, outputs (.3 kv) and power supply (3.7 kv) / Prevents measurement errors due to potential leakage Flexibility provided by more than 50 different input and output combinations selected by simply positioning soldered jumpers / Reduced stocking Non-standard user-specific ranges available AC/DC power supply / Universal Provision for either snapping the isolating amplifier onto top-hat rails or securing it with screws to a wall or panel Housing only 7.5 mm (size S7 housing) / Low space requirement Standard versions Inputs and outputs set to 0 0 ma. Any of the standard ranges given in the Section Technical data, measuring inputs are simply selected by positioning soldered jumpers. The fi ne adjustment is accomplished using the potentiometers Zero and Span. Table : Standard version with inputs and outputs Standard range Order Inputs Outputs Power supply No. and and 4 60 V DC/AC 8 80 0 0 ma 0 0mA 85 30 V DC/AC 8 80 Table : Standard version with input and outputs Standard range Order Input Outputs Power supply No. and 4 60 V DC/AC 8 88 0 0 ma 0 0 ma 85 30 V DC/AC 8 836 Please complete the Order Code 808-..... according to Table 4: Ordering information for versions with user-specifi c input and/ or output ranges. Camille Bauer Data sheet TV 808- Le 05.08
SINEAX TV 808, channels Technical data Measuring inputs DC current: 0 0. ma 0 0. ma 0 0.5 ma 0 ma 0 ma 0 5 ma 0 0 ma 0 0 ma 0. ma 5 ma 0 ma 4 0 ma 0 0. to 0 40 ma or span 0. to 40 ma between 40 and 40 ma R i = 5 Ω DC voltage: 0 0.06 V 0 0. V 0 0. V 0 0.5 V 0 V 0 V 0 5 V 0 0 V 0 0 V 0 40 V 0. V 5 V 0 V 4 0 V 0 0.06 to 0 40 V or span 0.06 to 40 V between 40 and 40 V R i = 00 kω Overload: DC current continuously -fold DC voltage continuously -fold Measuring outputs DC currents: Burden voltage: 0. + 0. ma 0. + 0. ma 0.5 + 0.5 ma + ma + ma 5 + 5 ma 0 +0 ma 0 + 0 ma 0. + 0. V 0. + 0. V 0.5 + 0.5 V + V + V 5 + 5 V 0 +0 V 0 + 0 V 0 0 ma, 4 0 ma, ± 0 ma 0 to 0 0 ma 0. to 4 0 ma 0 + to 0 0 + 0 ma V V External resistance: R ext max. [kω] = I AN [ma] I AN = Output circuit full-scale value DC voltage: Burden: Current limiter at R ext max.: Voltage limiter at R ext = : Residual ripple in output current: Response time: 0 0 V, 0 V, ± 0 V 0 to 0 0 V 0. to 0 V 0 + to 0 0 + 0 V U R ext min. [kω] AN [V] 5 ma U AN = Output circuit full-scale value Approx.. x I AN for current output Approx. 3 V < 0.5% p.p. < 50 ms Power supply H AC/DC power pack (DC and 45...400 Hz) Table 3: Nominal voltages and tolerances Nominal voltage U N Tolerance 4... 60 V DC / AC DC 5... + 33% 85... 30 V DC / AC AC ± 5% Power input:.6 W resp. 3.4 VA Accuracy data (acc. to DIN/IEC 770) Basic accuracy: Limit error ± 0.% Including linearity and reproducibility errors Reference conditions: Ambient temperature Power supply Output burden 3 C, ± K 4 V DC ± 0% and 30 V AC ± 0% Current: 0.5 R ext max. Voltage: R ext min. Influencing factors: Temperature < ± 0.% per 0 K Burden infl uence < ± 0.% for current output < ± 0.% for voltage output if R ext < R ext min. Longtime drift < ± 0.3% / months Switch-on drift < ± 0.% Common and transverse mode infl uence < ± 0.% Output + or connected to ground < ± 0.% For power supply > 5 V, the auxiliary circuit should include an external fuse with a rating 0 A DC. Data sheet TV 808- Le 05.08 Camille Bauer
SINEAX TV 808, channels Installation data Housing: Material of housing: Mounting: Position of use: Housing S7 See section Dimensional drawings for dimensions Lexan 940 (polycarbonate) fl ammability class V-0 acc. to UL 94, self-extinguishing, non-dripping, free of halogen For snapping onto top-hat rail (35 x 5 mm or 35 x 7.5 mm) acc. to EN 50 0 or directly onto a wall or panel using the pull-out screw hole brackets Any Terminals: DIN/VDE 0609 Screw terminals with wire guards, for light PVC wiring and max. x 0.75 mm or x.5 mm Permissible vibrations: g acc. to EN 60 068--6 Shock: Weight: 3 x 50 g 3 shocks each in 6 directions acc. to EN 60 068--7 Approx. 0, kg Electrical insulation: All circuits (measuring inputs / measuring outputs / power supply) are electrically insulated Regulations Electromagnetic compatibility: Protection (acc. to IEC 59 resp. EN 60 59): Housing IP 40 Terminals IP 0 The standards DIN EN 50 08- and DIN EN 50 08- are observed Electrical standards: Acc. to IEC 00 resp. EN 6 00 Operating voltages: Contamination level: Overvoltage category acc. to IEC 664: Double insulation: < 300 V between all insulated circuits III for power supply II for measuring input and measuring output Power supply versus all other circuits Measuring input versus measuring output Test voltage: Environmental conditions Climatic rating: Power supply versus: all 3.7 kv, 50 Hz, min. Measuring inputs versus: measuring outputs.3 kv, 50 Hz, min. Measuring input versus: measuring input.3 kv, 50 Hz, min. Measuring output versus: measuring output.3 kv, 50 Hz, min. Climate class 3Z acc. to VDI/VDE 3540 Commissioning temperature: 0 to + 55 C Operating temperature: 5 to + 55 C Storage temperature: 40 to + 70 C Annual mean relative humidity: 75% Altitude: 000 m max. Indoor use statement!! Table 4: Ordering information (see also Table and : Standard versions ) DESCRIPTION MARKING. Mechanical design Housing S7 for rail and wall mounting 808-. Number of channels channels 3. Version / Power supply Standard, 4 60 V DC/AC Standard, 85 30 V DC/AC 4. Function inputs, electrically insulated outputs input, electrically insulated output 3 5. Input signal, input Input [V] 9 [V] 0 0.06 to 0 40 or span 0.06 to 40 V between 40 and 40 V Input [ma] Z [ma] 0 0. to 0 40 or span 0. to 40 ma between 40 and 40 ma Camille Bauer Data sheet TV 808- Le 05.08 3
SINEAX TV 808, channels DESCRIPTION MARKING 6. Output signal, output Output [V] 9 [V] 0 to 0 0 0. to 0 0 + to 0 0 + 0 Output [ma] Z [ma] 0 to 0 0 0. to 4 0 0 + to 0 0 + 0 7. Input signal, input Without input 0 Input [V] 9 Input [ma] Z Ranges possibles see input 8. Output signal, output Output [V] 9 Output [ma] Z Ranges possibles see output Electrical connections 6 7 Span Zero Camille Bauer AG CH-560 Wohlen Switzerland Span Zero 3 8 4 9 Front 6 7 ON 3 8 4 9 Space e.g. for MSK designation ON Green LED for device standing by Possible special versions, e.g. increased climatic rating on inquiry. 5 0 Without transparent cover 5 0 With transparent cover 6 7 4 9 3 8 5 0 I+ U+ I+ U+ + + + E E A A H E = Input E = Input A = Output A = Output H = Power supply Configuration. Standard input ranges Soldered jumpers are provided for the coarse setting of the input ranges and the fi ne adjustment is accomplished using the potentiometers Zero and Span. 00 must be added to the designations of the soldered jumpers in the table for channel and 00 for channel. (Example: input range for input and input = 0 0 ma. Jumpers, 5, 6 and must be inserted for this range. The corresponding jumpers for channel are B 0, B 05, B 06 and B. The corresponding jumpers for channel are B 0, B 05, B 06 and B ). 4 Data sheet TV 808- Le 05.08 Camille Bauer
SINEAX TV 808, channels Current [ma] Soldered jumpers Voltage [V] Soldered jumpers 0 0. 0 0. 0 0.5 0 0 0 5 0 0 0 0, 3, 3, 4, 4, 4, 5, 5, 5 7, 0, 8, 9, 0, 7, 0, 8, 6, 7, 8, 0, 0, 6, 0 0.06 0 0. 0 0. 0 0.5 0 0 0 5 0 0 0 0 0 40 6, 9, 0, 7, 8, 0, 6, 8, 9, 6, 7, 8, 9, 0 6, 7, 8, 0, 7, 8, 9, 8, 0 0, 6, 8 0. 5 0 4 0, 4, 4, 5, 5 8, 0, 6, 9 6, 7, 0, 6, 7, 8,, 5, 5, 5, 5 0. 5 0 4 0 9, 0, 6, 8, 9, 0 6, 7, 0, 6, 7, 8,, 5, 5, 5, 5 0. 0 + 0. 0. 0 + 0. 0.5 0 + 0.5 0 + 0 + 5 0 + 5 0 0 + 0 0 0 + 0, 3, 3, 4, 4, 4, 5, 5, 5 8, 7, 9 7, 0, 8, 6, 9 0, 6, 6, 7 0. 0 + 0. 0. 0 + 0. 0.5 0 + 0.5 0 + 0 + 5 0 + 5 0 0 + 0 0 0 + 0 6, 8, 9, 6, 7, 9, 0 7, 8, 0, 7, 8, 9, 6, 8, 9, 0 0, 6, 8. Standard output ranges Soldered jumpers are provided for the coarse setting of the output ranges and the fi ne adjustment is accomplished using the potentiometers Zero and Span. B06 B0 B0 B03 B04 B05 B07 B08 B09 B0 B Current [ma] Soldered jumpers Voltage [V] 0 0 B 0 B 0 0 0 4 0 B B 0 ± 0 ± 0 Soldered jumpers B 0 B B 3 B B B 3 B B 3 B 0 B B 3 B B B 3 B B 3 Span Zero Span Zero B B B0 B3 B B B0 B06 B3 B B3 B4 B5 B6 B7 B3 B4 B5 B6 B7 B07 B08 B09 B0 B B 3. Specific user output ranges Units that have been confi gured for a specifi c user output range cannot be subsequently reconfi gured. B0 B0 B03 B04 B05 Fig.. Position of the soldered jumpers B and the potentiometers Span and Zero. Camille Bauer Data sheet TV 808- Le 05.08 5
SINEAX TV 808, channels Dimensional drawings 4 6.5 0 0 34 Ø4.5 0 7.5 +0.5 +0 46.5 7.5 +0.5 +0 45.5 Fig. 3. SINEAX TV 808 in housing S7 clipped onto a top-hat rail (35 5 mm or 35 7.5 mm, acc. to EN 50 0). Fig. 4. SINEAX TV 808 in housing S, screw hole mounting brackets pulled out. Standard accessories Operating instructions in three languages: German, French, English Withdrawing handles (for opening the housing) Labels (under transparent cover) Rely on us. Camille Bauer Ltd Aargauerstrasse 7 CH-560 Wohlen / Switzerland Phone: +4 56 68 Fax: +4 56 68 35 35 e-mail: info@camillebauer.com www.camillebauer.com Subject to change without notice Edition 05.08 Data sheet TV 808- Le