PF/PFQ. High Amperage plug and receptacle. Main Advantages

Similar documents
Meltric Part Numbering...

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

Baymaster LED Luminaire High Bay for Hazardous Locations

Amphenol. Amphenol 97 Series Standard Cylindrical Connector. MIL-5015 Style Connectors widely used for:

Alternating Current Power

Pentagon. Fileguard Installation Instructions 1 IMPORTANT NOTE

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

FEATURES OPTIONAL FEATURES

LN-25 PRO WIRE FEEDERS

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

Open Type Without Enclosure

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

P3-19 Series Connectors For Entertainment Lighting

Overview The Thomas & Betts Method is Better. Just Four Easy Steps to a Perfect Connection! Step 1. Step 2

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration

LN-25 PRO Wire Feeder

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

LR Position Switches TECHNICAL DATASHEET

General Information...SA1-SA4

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Connection by Compression

Open Type Without Enclosure

Ground Clamps Cable Tray

Connection by Compression

LN-25 PRO Wire Feeder

Thru Wall Floor Seals For New Installation

Position switches FM series

Amphenol. Advantage. R-Line R-146. Rectangular Attached Multi-Pin Industrial Cable Assemblies. Amphenol - Sine Systems

Warehouse Stock Transformers

Micro-Change. Cordset Family

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

INTERMEDIATE METAL CONDUIT

FM series position switches

NEMA Contactor and Starter Specifications

Spring Return DuraDrive Proportional Actuator

KRPA, KRP, KA, KR series

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Safety switches with slotted hole lever

KING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834

Installation & Operation Manual

Color-Keyed. Compression Connector System. Table of Contents

Rectangular Industrial Connectors: Technical Data Overview EPIC HBE SERIES

DeviceNet Series. Cables Cordset Accessories Receptacles Receptacle Accessories Junction Blocks

242, , FAX.

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

Microminiature MTB1

Installation Instructions. Materials Needed. Parts Included. Tools You Will Need

18500 PORTABLE ELECTRIC POWER DRIVE

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

18600 PORTABLE POWER DRIVE THREADER PRODUCT INFORMATION AND OPERATING INSTRUCTIONS:

KING-GAGE ES2. Installation and Operation Instructions Manual. Electronic Liquid Level Transmitter. ESR Serial No. Versions and Slimline Versions

7000 Series Bronze Globe Valves Two-Way Normally Open

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

Active UTP Transceiver Hub Installation Guide

PSOL. Remove mounting screws. Remove ears. Add 6" leads PSOL = #12 AWG solid PSTR = #12 AWG stranded

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Sealed Interface Control: EC20300

Datasheet MIL-C-5015 series connectors

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

Professional Features: Base Unit Includes: Required Options: TECHNICAL SPECIFICATIONS

Self-Powered Counters H7ET

Torque Sensor Accessories and Services

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

HLC-1000 High-limit Humidity Control

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Double thick tongue. Tongue Wire Stud Hole CT-930, CT-930CH, S4-10R-E

Installation Instructions

SERIES 70 ELECTRIC ACTUATORS THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

Electrical Power Transfer Products

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Components for safety applications

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

1904, 1904Pg, 1904PgSB, and 1906SB High Capacity Ratchet Knockout Drivers

Precision and High Reliability Thermostats Issue 3. Datasheet. Table of Contents

FITTINGS & GAUGES 20,000 PSI

Holemaking. FEATURED Products. Slug-Splitter SC (Self-Centering) Knockout Punches NEW. Bi-Metal Hole Saws with Stops. NEW Quick Connect Extensions

Cable & Bolt Cutters. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Power Distribution Blocks with Short-Circuit Current Ratings

Metal Bending Tools, Scribes & Awls

tings fi t fl ex/mc/ac

10 to 30 VDC (10% max. permissable ripple peak-to-peak)

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM )

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance.

MEDIUM VOLTAGE

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

Model Number Structure

FDM Medium Voltage Controller

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

Electrical dielectric withstanding voltage. sea level Vrms Vrms m Vrms Vrms

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Transcription:

High Amperage plug and receptacle Main Advantages u u u Durable in harsh environments Safety features provide maximum protection Easy plug insertion and removal Watch the PF video and other product videos at meltric.com/video Features and Ratings p. 133 300-600A p. 134 Lugs p. 136 Spare parts p. 138 Dimensions p. 139 PFQ300 devices are differentiated from similarly rated PF300 devices in their smaller size, lighter weight and additional pilot contacts. 132

PRODUCT FEATURES Operating Instructions Auxiliary Pilot Contacts Provided for use with control circuits. They close after and open before the phase contacts. Mechanical Locking System Ensures safety and watertightness. Mechanical lock secures the inlet to the receptacle and engages the auxiliary/pilot contacts. 1 PF devices are preferred for the ease of operation relative to pin and sleeve devices. 2 Casing Epoxy/powder coated aluminum material offers great resistance to harsh environments. Silver Pressure Contacts Silver material and self-cleaning action provides maximum conductivity and performance in dirty and corrosive conditions. Safety Shutter Protects recessed female contacts and inhibits user access to live parts. Insert the plug into the receptacle this is done with little resistance relative to competitive devices. General Ratings Amperage Voltage + Frequency Environmental 300 to 600A 1000 VAC*, 1000 VDC Max 50-400 Hz (not UL at 50 Hz) IP66/IP67 Listings Category UL CSA Plugs and Receptacles UL 1682 C22.2 No. 182.1 * Listings only apply to 300A and 400A devices at 600v or less. Twist plug approximately 30 clockwise to engage the phase contacts and make unit watertight. 3 HIGH AMPACITY Temperature min -40 F/max 140 F * 600 VAC max for PFQ devices + IUL listings do not apply above 600 VAC and 250 VDC. Highlighted Feature TO LOAD A B C INLET/PLUG MALE PILOT CONTACTS JUMPER 2 PILOT CONTACTS TO COMPLETE CIRCUIT NOTE: ROTATE RECEPTACLE LOCKING CAM TO ENGAGE PILOTS RECEPTACLE/ CONNECTOR FEMALE PILOT CONTACTS PHASE PILOT CIRCUIT Line diagram of typical PF pilot control circuit For multiple devices in a parallel circuit, contact factory for example control circuit diagrams. A B C Pilot Contacts CONTACTOR OR BREAKER WITH UNDER VOLTAGE TRIP COIL LINE PILOT CIRCUIT POWER SWITCH ETC. Category PF PFQ # Contacts 4 8 Pilot Amperage 10A standard duty 5A @ 240VAC Interlocking Type Mechanical Mechanical Terminal Type Screw Solder/crimp Notes: The mechanical locking of the plug to the receptacle via the rotation of a cam, closes the pilot contacts. Failure to use a pilot/relay system can create an electrical shock hazard. 4 Turning the mechanical lock secures the inlet to the receptacle and engages the pilot contacts which energize the circuit. 5 To disconnect, turn mechanical lock to disengage pilot contacts and de-energize the circuit. Twist plug 30 counterclockwise to disengage the phase contacts, withdraw plug. 133

High Ampacity Plugs & Receptacles 300A-600A UL/CSA Ratings Max Amperage & Voltage PF = 600A, 1000 VAC*, 250 VDC PFQ = 300A, 600 VAC, 250 VDC Current Interruption Capability Not for current interrupting Environmental Ratings IP66/IP67 Temperature Range Min -40 F/Max 140 F See pg 253 for temps below -15 F. Wiring Capacity PFQ = 2 AWG to 600 MCM PF = 2 AWG to 600 MCM Certifications UL 1682*, CSA 182.1* * Listings apply only to 300A & 400A devices at 600V or less devices are not intended for connection or disconnection under load. To prevent live making or breaking electrical interlocking is required. Don t forget to add installation accessories to your order Voltage Polarity Receptacle/Cap 300A (female) PFQ shown North American UL/CSA Configurations Inlet/Cap 300A (male) PFQ shown Part # Part # PFQ 300** PF300 PFQ 300** PF300 277V 1P+N+G 47-34045 49-34045 47-38045 49-38045 347V 1P+N+G 47-34145 49-34145 47-38145 49-38145 480V 2P+G 47-34042 49-34042 47-38042 49-38042 480V 2P+N+G 47-34046 49-34046 47-38046 49-38046 480V 3P+G 47-34043 49-34043 47-38043 49-38043 480V 3P+N+G 47-34047 49-34047 47-38047 49-38047 600V 2P+G 47-34142 49-34142 47-38142 49-38142 600V 2P+N+G 47-34146 49-34146 47-38146 49-38146 600V 3P+G 47-34143 49-34143 47-38143 49-38143 600V 3P+N+G 47-34147 49-34147 47-38147 49-38147 ** PFQ300 devices are differentiated from similarly rated PF300 devices in their smaller size, lighter weight and different pilot contacts. For international configurations and ratings (IEC,CE) visit meltric.com/international-catalog or contact customer service at 800.433.7642. Main Options Part # 134 Receptacle with no cap Recept # - 48 Receptacle with lockout hole Recept # - 843 Inlet with no cap Inlet # - 48 Receptacle with lockout hole Inlet # - 843 Notes: Metal caps are provided as standard with male and female devices. Heat shrink wrap is provided with each inlet and receptacle to provide insulation between terminals. Lugs are not included. The PF and PFQ contacts utilize bolt-on lug type wire terminals, which require a compression lug with a 9/16 or 5/8 hole. The angled handle requires straight lugs; the straight handle requires 90 lugs. See pages 230-239 for detailed information on these options Voltage Polarity Receptacle/Cap 400A/600A (female) North American UL/CSA Configurations Inlet/Cap 400A/600A (male) Part # Part # PF400 PF600 PF400 PF600 277V 1P+N+G 49-44045 49-64045 49-48045 49-68045 347V 1P+N+G 49-44145 49-64145 49-48145 49-68145 480V 2P+G 49-44042 49-64042 49-48042 49-68042 480V 2P+N+G 49-44046 49-64046 49-48046 49-68046 480V 3P+G 49-44043 49-64043 49-48043 49-68043 480V 3P+N+G 49-44047 49-64047 49-48047 49-68047 600V 2P+G 49-44142 49-64142 49-48142 49-68142 600V 2P+N+G 49-44146 49-64146 49-48146 49-68146 600V 3P+G 49-44143 49-64143 49-48143 49-68143 600V 3P+N+G 49-44147 49-64147 49-48147 49-68147 For international configurations and ratings (IEC,CE) visit meltric.com/international-catalog or contact customer service at 800.433.7642.

INSTALLATION ACCESSORIES SIZE C & F HANDLES METAL STRAIGHT HANDLE Part # PF shown PFQ300 0 47-3A013-XXX PF300 0 49-3A013-XXX PF400 0 49-4A013-XXX Standard Clamp shown PF600 0 49-6A013-XXX Metal Angled Handle PF shown Standard Clamp shown PFQ300 90 47-3A913-XXX PF300 90 49-3A913-XXX PF400 90 49-4A913-XXX PF600 90 49-6A913-XXX BOXES METAL JUNCTION BOX Part # * 7.0 in 3 PFQ300 PF300 See table See table MB40PFQ-XX MB40-XX This box is a heavy duty powder coated Aluminum back box PF400 See table MB40-XX with removable cover. Conduit entry hub up to PF600 See table MB40-XX 4 NPT can be ordered on one or both ends or even on the back of the enclosure. Multiple hubs and sizes can be ordered for installs with parallel entry s on one end of the box. STAINLESS STEEL JUNCTION BOX PFQ PF NPT Adapter NPT Size XXX (Suffix #) 2.0 47-4A023-N020 47-4A023-N520 2.0 2.5 3.0 Standard Clamp w/cable Range -N20 -N25 -N30 2.000-2.125-200 2.125-2.250-225 2.250-2.375-237 2.375-2.500-250 2.500-2.750-275 For available cord grips, see pg 178. 2.5 47-4A023-N025 47-4A023-N525 3.0 47-4A023-N030 47-4A023-N530 3.5 47-4A023-N035 47-4A023-N535 4.0 47-4A023-N040 47-4A023-N540 STAINLESS STEEL JUNCTION BOX PFQ PF 2.0 49-6A023-N020 49-6A023-N520 2.5 49-6A023-N025 49-6A023-N525 3.0 49-6A023-N030 49-6A023-N530 3.5 49-6A023-N035 49-6A023-N535 These enclosures offer additional interior volume for extra wiring space. Both size enclosures have two removable covers and a one piece back pan installed for customer convenience. Conduit entry up to 4 NPT is limited to the bottom of the enclosure. 2.750-3.000-300 4.0 49-6A023-N040 49-6A023-N540 3.000-3.125-312 Hub Sizes Fitting Size XX (Suffix #) 3.125-3.350-335 2.0-20 3.350-3.577-350 Accessory Spotlight NPT Adapter NPT Adapter Straight or Angled Handle Cord Grip w/mesh (not included with adapter) A NPT adapter accessory allows the user to connect a third party cord grip to the handle. MISCELLANEOUS ACCESSORIES WEIGHTS INLET METAL CAP PF shown 2.5-25 3.0-30 3.5-35 4.0-40 RECEPTACLE METAL CAP PFQ300 47-3A126 PF300 49-3A126 PF400 49-4A126 PF600 49-6A126 PFQ300 47-3A925 PF300 49-3A925 PF400 49-4A925 PF600 49-6A925 PART PF PFQ Inlet 15 lbs 9 lbs Receptacle 25 lbs 12 lbs HIGH AMPACITY Angled Handle 15 lbs 12 lbs Straight Handle 10 lbs 10 lbs Junction Box 45 lbs 45 lbs Cap 3 lbs 3 lbs Stainless Steel Box 85 lbs 55 lbs 135

High Ampacity Plugs & Receptacles 300A-600A Straight Barrel Lugs MELTRIC recommends using lugs with tangs that do not exceed 1 3/4. Lugs are not included with PF/ PFQ devices - order separately Part # Wire Size Application Note PFLUG4 PFLUG3 PFLUG2 PFLUG1 PFLUG10 PFLUG20 PFLUG30 PFLUG40 PFLUG250 PFLUG300 PFLUG350 PFLUG400 PFLUG500 PFLUG600 PFLUG650 4 AWG 3 AWG 2 AWG 1 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG 250kcmil 300kcmil 350kcmil 400kcmil 500kcmil 600kcmil 650kcmil Installation Accessory: Angled Handle Straight Barrel Lugs are utilized on PF/ PFQ devices along with angled handles. Typical wiring of a PF male inlet for angled handle applications. Apply heat shrink over lungs at terminals (supplied but not shown). Receptacle shown 136

90 Bent/Angle Lugs MELTRIC recommends using lugs with tangs that do not exceed 1 3/4. Lugs are not included with PF/ PFQ devices - order separately Part # Wire Size Application Note PFLUG4-90 PFLUG3-90 4 AWG 3 AWG Installation Accessory: Straight Handle PFLUG2-90 2 AWG PFLUG1-90 1 AWG PFLUG10-90 1/0 AWG PFLUG20-90 2/0 AWG PFLUG30-90 3/0 AWG PFLUG40-90 4/0 AWG PFLUG250-90 250kcmil PFLUG300-90 300kcmil PFLUG350-90 350kcmil PFLUG400-90 PFLUG500-90 PFLUG600-90 400kcmil 500kcmil 600kcmil 90 Bent Lugs are utilized on devices along with straight handles. HIGH AMPACITY Typical wiring of a PF male inlet for straight handle applications. Apply heat shrink over lungs at terminals (supplied but not shown). Inlet shown 137