Cat# 71440A LED Classic Large Wall-Pack Dimming: 0-10V/PWM/VR QPL ID # PL8EA2B65DY8 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Surface Output Voltage Output Current Driver Efficiency LED Type LED Quantity LED Manufacturer LED Efficacy Color Temperature Lifespan Warranty IP Rating Operating Temperature Storage Temperature.Humidity Safety Norms Withstand Voltage Grounding Resistance Electromagnetic Compatibility 71440A 100-277VAC.98@120VAC,.47@277VAC 120W PF 0.9 13520 LM 115 LM/W >70 120 Alluminium + Tempered Glass Baking Varnish 25.2-42VDC 1.2A 88% LUMILED LUXEON 3030 100 PCS Philips 130 lm/w 5000K 50,000 Hrs. 5 Years IP65-40 F +131 F -40 F +176 F, 10 90% RH EN60598, EN61347-2-13, EN62031, EN62471, UL1598, UL8750 I/P-FG: 2121VDC 25A 100mΩ EN55015, EN61000-2-3, EN61000-3-3, EN61547 OTHERS Diamension Net Weight(Kg) Gross Weight(Kg) Box Size Carton Size Q'ty / Carton Pls refer to attached dimension drawing 4.3 5.2 -- 390*230*315 1
Dimension: 71440A www.morrisproducts.com
LM-79-08 Test Report For Morris Products Inc. 53 Carey Rd. Queensbury, NY 12804 Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): 71440A, 71441A Representative (Tested) Model: 71440A Model Different: All construction and rating are the same, except CCT Test & Report By: Sevon Li Engineer: Sevon Li Date: Apr.05,2017 Review By: Manager: Tommy Liang Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. 1 / 10
1.1 Product Information: Organization Name Morris Products Inc. Brand Name MORRIS Model Number 71440A SKU (if available) N/A Type of Luminaire (for integral lamps, list base type and lamp type) Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Rated Voltage / Frequency 100-277Vac, 50/60 Hz Nominal Power 120W Rated Initial Lamp Lumen -- Declared CCT 5000K LED Manufacturer Philips Lumileds LED Model LUXEON 3030 2D Sample Number GZE170125-Z1(4000K),Z2(5700K) Luminaire Aperture (for downlights) -- in. Luminaire Length -- mm Luminaires Width -- mm Number of Units (modular products) N/A s Photo 2 / 10
1.2 Test Specifications: Date of Receipt Mar. 28,2017 Date of Test Mar. 31,2017 1. Total Luminous Flux 2. Luminous Distribution Intensity 3. Luminous Efficacy Test item 4. Correlated Color Temperature 5. Color Rendering Index 6. Chromaticity Coordinate 7. Electrical Parameters 1. IES LM-79-2008 Electrical and Photometric Measurements of Solid-State Lighting Products 2. ANSI C78.377-2008 Specifications for the Chromaticity of Solid State Lighting Products Reference Standard 3. CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering Properties of Light Sources 4. CIE 15-2004 Technical Report Colorimetry 5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source 6. IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED) Sources and Systems Reference Work Instruction QD25 1.3 Test Methods 1) Photometric and Light Distribution Measurement Goniophotometer Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1 vertical intervals and 22.5 horizontal intervals. 2) Chromaticity Measurement Sphere-Spectroradiometer Method: Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25ºC ± 1ºC. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral power distribution taken at 5 nm intervals over the range of 380 to 780 nm. 3) Electrical Measurements: Electrical parameters were measured using power meters incorporated in goniophotometer or sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at 25ºC ± 1ºC. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion were measured by and read from the power meter. 3 / 10
2.1 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date 2017-03-31 Test Ambient: 25.2 ºC Test Orientation As intended Stabilization Time (min) 90 Model Number 71440A Electrical Measurement : Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE170125-120.0 60 0.9775 116.7 0.9949 7.78 Z1 277.0 60 0.4689 116.8 0.8992 11.37 DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Chromaticity Measurement - Sphere-Spectroradiometer Method : Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 R1 71 R9 0 Frequency (Hz) 60 R2 78 R10 47 CCT (K) 4078 R3 83 R11 70 Duv -0.0012 R4 73 R12 46 Chromaticity (x, y) x=0.3763 y=0.3717 R5 70 R13 71 Chromaticity (u, v ) u'=0.2244 v'=0.4987 R6 69 R14 90 Color Rendering Index (CRI) 72.5 R7 80 R15 65 R9 0 R8 56 -- -- Photometric Measurement Goniophotometer Method : Parameter Result DLC V4.0 Pass Criteria Test Voltage (V) 120.0 277.0 Frequency (Hz) 60 60 -- Total Luminous (lm) 14293 14212 >=10000 (-10%) Luminous Efficacy (lm/w) 122.48 121.68 -- Total Luminous (lm) (0-90 zone) 11749.3 11683.0 -- Luminous Efficacy (lm/w) (0-90 Standard: >= Premium: >= 100.68 100.03 zone) 100(-3%) 120(-3%) Zonal lumens in the 80-90 zone (%) (0-90 zone) 10.97% -- <=10(+3) Beam Angle ( ) 109.0 -- -- Center Beam Candle Power (cd) 3273 -- -- 4 / 10
Spectral Power Distribution & Chromaticity Diagram Zonal Lumen Tabulation Zonal Lumen Summary Lumens Per Zone Zone Lumens % Luminaire Zone Lumens % Total Zone Lumens % Total 0-30 2,462.3 17.2% 0-40 3,880.3 27.1% 0-60 7,113.9 49.8% 60-90 4,634.7 32.4% 70-100 3,933.8 27.5% 90-120 2,158.0 15.1% 0-90 11,748.6 82.2% 90-180 2,544.0 17.8% 0-180 14,292.6 100% 0-10 322.9 2.3% 90-100 1,031.1 7.2% 10-20 889.9 6.2% 100-110 719.9 5% 20-30 1,249.5 8.7% 110-120 407.0 2.8% 30-40 1,418.0 9.9% 120-130 191.9 1.3% 40-50 1,539.5 10.8% 130-140 103.1 0.7% 50-60 1,694.1 11.9% 140-150 58.2 0.4% 60-70 1,732.1 12.1% 150-160 24.6 0.2% 70-80 1,613.4 11.3% 160-170 7.1 0% 80-90 1,289.3 9.0% 170-180 1.0 0% 5 / 10
Photometric Data 6 / 10
7 / 10
2.2 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date 2017-03-31 Test Ambient: 25.2 ºC Test Orientation As intended Stabilization Time (min) 90 Model Number 71440A Electrical Measurement : Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE170125-120.0 60 0.9791 116.9 0.9950 7.75 Z2 277.0 60 0.4706 117.3 0.8998 11.61 DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Chromaticity Measurement - Sphere-Spectroradiometer Method : Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 R1 81 R9 9 Frequency (Hz) 60 R2 89 R10 72 CCT (K) 5785 R3 92 R11 80 Duv 0.0028 R4 82 R12 56 Chromaticity (x, y) x=0.3261 y=0.3409 R5 82 R13 84 Chromaticity (u, v ) u'=0.2026 v'=0.4765 R6 83 R14 96 Color Rendering Index (CRI) 83.1 R7 88 R15 77 R9 9 R8 69 -- -- Photometric Measurement Goniophotometer Method : Parameter Result DLC V4.0 Pass Criteria Test Voltage (V) 120.0 277.0 Frequency (Hz) 60 60 -- Total Luminous (lm) 14658 14645 >=10000 (-10%) Luminous Efficacy (lm/w) 125.39 124.85 -- 8 / 10
Spectral Power Distribution & Chromaticity Diagram 9 / 10
3. Test Equipment Equipment ID Equipment Name Last Calibration Date Next Calibration Date ST-R-336 2 meter Integrating Sphere 2016-07-01 2017-06-30 ST-R-331 Spectral analysis system HAAS-2000 2016-07-01 2017-06-30 D204 Standard Lamp 2016-07-01 2017-06-30 PF2010 Power Meter for Integrating Sphere 2016-07-01 2017-06-30 EE-09 Goniophotometer system 2016-07-01 2017-06-30 D908S Standard Lamp 2016-07-01 2017-06-30 PF210 Power Meter for Goniophotometer 2016-07-01 2017-06-30 ST-R-181A Temperature Tester 2016-07-01 2017-06-30 Uncertainty: Photometric Measurement (Sphere):1.74% Chromaticity Measurement(Sphere):14.3K Photometric Measurement(Goniophotometer):1.62% ****** END OF REPORT ****** 10 / 10