Pentagon. Fileguard Installation Instructions 1 IMPORTANT NOTE

Similar documents
Tubular Deadbolts. Deadbolt Series HDD Features Ordering String HDD Functions Trim Sets Suggested Specification

DOOR TECHNOLOGY ORDER CATALOG SECTION SECURY Automatic Door Lock & Gripset Handle

Hookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel

Locks. Locks OUTLETS NATIONWIDE

M O R T I S E L O C K S

OFFSET PIVOTS STOREFRONT HARDWARE

PF/PFQ. High Amperage plug and receptacle. Main Advantages

MEETS ADA REQUIREMENTS!

Mortise Locks. European Mortise Locks Series EML Features Ordering String Functions Trim Sets European Profile Cylinders Specifications

MORTISE LOCKS RESIDENTIAL SERIES

Mortise Locks. Narrow Mortise Locks Series NML Features Ordering String Functions Trim Sets Cylinders Strikes Specifications

2000/2100/2200 Series

Tubular Latches. 3 a. Heavy Duty Lever Latches Series HLL Features Ordering String Functions Dummy Mounts Trim Sets Specifications

Your global resource for quality commercial door hardware. Euroline Catalog Euroline Catalog

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

PD5000 Sliding/Pocket Door Locks

Universal Voice Coil and 70 Volt Door Speaker V / V

No. 059FL. No. 251FL. No. 260FL. No. 305RE. Etruscan Bronze. Florentine Brass. Siena Brass (D) All designs available in these finishes.

COJSAWBX Electric Jig Saw Assembly & Operating Instructions

BC145 SIGNAL ISOLATOR BOARD

Deadlatch & Deadbolt Accessories

Junction Box Padlock Kit. Field installed kit requires drilling of only 4 holes. Compatible with 1414 Series

Weslock-Molten Bronze Collection Entry Handle Features

ELECTRIC LOCKS & ACCESSORIES

In-Tube Motorized SCREEN-PRO. All Season Roll-Up Doors IN-JAMB MOUNTING METHOD INSTALLATION INSTRUCTIONS READ THIS FIRST

General Installation Instructions

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

MC CHANGER CABINET INSTALLATION INSTRUCTIONS

Mortise Locks 185 Series

Assembly Instructions 10 X 10 Aluminum Frame Building

METRIC LIGHTNING PROTECTION PRODUCTS

This section describes the design requirements and materials/products for door hardware.

STOPS. TRIMCO# 1207 B 2-1/4 P 3-3/4 EYE 7/8 x 2-1/4 HOOK 2-3/4 BHMA L01351

DB1000 SERIES. Heavy-Duty Tubular Grade 1 Deadbolts. Standard Features. Optional Features. Options

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Daloc S33 (Y33) Security door RC3

Deadlatch 451 Series. Faceplates - Deadlatch. Strikes - Deadlatch. DeadLatch for Aluminum Stile Doors. Non-Handed. 451 NC0772 1¹ 8 Backset Deadlatch 4

NEXUS NX50-1, -2 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION

PRODUCT MANUAL 5-IN-1 MITER SAW STATION *SAVE THIS MANUAL FOR FUTURE REFERENCE

Fire Rating 3 hours- hollow metal doors mounted singly 90 minutes- hollow metal and composite core wood fire doors 20 minutes- wood doors

INSTALLATION INSTRUCTIONS LARGE FLAT PANEL IN WALL ENCLOSURE Model: PAC-500

Mounting Instructions for Cisco Aironet 1550 Series Outdoor Access Point Pole-Mount Kits

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

5570M Series Intercom Installation and Operation Guide

A. Keyless, electronic access control using a PIN (Personal Identification Number)

Elderfield & Hall, Inc., Kama Bandsaw AD 105S. Instruction Manual: Introduction to the Manual. General Precautions. Equipment. Machine.

18500 PORTABLE ELECTRIC POWER DRIVE

18600 PORTABLE POWER DRIVE THREADER PRODUCT INFORMATION AND OPERATING INSTRUCTIONS:

55 Series Exit Device

SLW 6 Channel Letter Brake. User Guide. Operation and Mounting Instructions

MTS-SP100. RENOGY Pole Mount System E Philadelphia St, Ontario, CA Version: 1.2

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N)

ACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES WIRE MESH PARTITION FOLDING GATE

E-PLEX 3X00 SERIES NARROW STILE LOCK INSTALLATION INSTRUCTIONS

OXYGEN INSTALLATION. Revision date

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

PIN Access Electronic Pushbutton Lock 100 Access Codes 1,000 Audit Events Cylindrical, Mortise, and Exit Trim ANSI/BHMA Grade 1 Certified

376E Series Exit devices

PREMIUM QUALITY GATE LOCKS DESIGNED IN THE UK

Push and Pull Door Furniture. Plate Door Furniture Door Furniture and General Hardware

P USHbutton 500 series

SLIDING DOOR LOCKS MISCELLANEOUS

Available in two PVD finishes

HERCULES EXTENDED TOWER


Architectural Door & Cabinet Door

Aluminum Continuous Geared Hinges

ELECTRONIC ROTARY GEAR MOTOR SERIES SED (AR2...SE )


General Machine Instructions

D800 DB600. Grade 1 Heavy-Duty and Grade 2 Dead Bolts

TABLE OF CONTENTS DRAWINGS

Assembly Instructions 10 X 10 Aluminum Roof Support

Ribcage Installation. Part 2 - Assembly. Back-Bone V1.06

CSS Central Mount System

Auxiliary Hardware Brass Padlocks

INSTRUCTIONS FOR HIT LOCK MORTISER

L-Series Commercial Locks

EC centrifugal fan - RadiCal

INSTRUCTION MANUAL. Model 18AVQII Five Band Vertical Antenna 10, 15, 20, 40, 80 Meter. General Description. Theory of Operation

Introduction. Commitment To The Environment

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

Headline Push/Pull Latches

Installation Instructions (For Dealer or Contractor)

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

Assembly Instructions

Tools Required. * When installing on a fire door, please see instructions below. *

Hardware Fitting Accessories Bolts

alpro Commitment to Excellence door furniture

Mounting instructions SZ210 Full-frame pedestal with screw-on tube with placement hinge, for type SCHATTELLO

FINISTA FRENCH DOOR RANGE. Finista French Door Range. > Functional style and security

Bravura. UL Listed Commercial Locksets FORGED. Designs from Great European Homes. Fall 2009

MEDIUM DUTY LOCKS - LEVERS. Distributed By. DH Pace National Key Service Center DHPace.

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

Industrial Wall Fan SAX Installation and Maintenance Instructions

COMPONENTS P A N E L + S H E L F F I X I N G S A C R Y L I C S A C C E S S O R I E S F I N m m C A B L E m m R O D.

Tuf-Lite III Fans 5000K Series Hub

Architectural Door & Cabinet Hardware

PHONE: FAX:

Transcription:

Fileguard Installation Instructions 1 Tools that will be needed for this installation are: NOTE: DO NOT THROW OUT ANY PACKAGING MATERIAL UNTIL THE INSTALLATION IS COMPLETE AND YOU ARE SURE THAT YOU HAVE FOUND ALL OF THE COMPONENTS SENT WITH THE SHUTTER. nents: (see Figure A below) SHUTTER BOX S WITH EXTENDERS INSTALLATION KIT WITH CLAMPS Figure A IMPORTANT NOTE PRESSURE ON THESE LEGS DURING THE INSTALLATION.

Fileguard Installation Instructions 2 OPTION 1- NO HEADROOM (see Figure C & D SIDE A/ COIL SIDE EXTENDER Figure C Figure D

Fileguard Installation Instructions 3 Figure E & F MAKE SURE EXTENDER SHELVING UNIT Figure E Figure F BOLT ON CLAMP FACING EXTENDER Figure G

Fileguard Installation Instructions 4 OPTION 2-12 OF HEADROOM Figure E & F Figure G Figure H FASTEN SUPPORT BAR TO BOX AT THIS LOCATIONS Figure H Figure I Figure I 1-866-705-4668

KEY SWITCH CONTROL SPECIFICATIONS FEATURES Single gang standard. Narrow style Left and/or right operation and double gang models available Momentary operation standard mortise UL/CSA approved switches cylinders, 1 1 1/4 Indoor or outdoor applications Heavy duty ¼ thick aluminum Tamper proof screws provided plate Cylinder sits flush to faceplate 1 piece die cast construction Fast & easy to install Locators prevent cylinder from Casted centre rib protects spinning switches from damage No set screws required Brushed aluminum finish Vandal resistant Custom colour finishes & engraving available DESCRIPTION recessed and surface mount key switches meet the stringent demands of key switch controls. They are designed for use with standard 1, 1 1/8 or 1 1/4 mortise cylinders. These switches are fabricated from ¼ thick aluminum, in a one piece die cast construction. Standard Is a single gang (2 ¾ ) width. Also available is a double gang model. Both models accept one or two switches, and have a counter sunk cylinder opening, in a one piece casted assembly. A brass cylinder with Schlage keyway, a brass cylinder lock ring, socket/slotted screws, and 2 tamperproof screws are also supplied. The design and construction makes it ideal for all weather environments. The assembly is tamper and vandal resistant. Key Switches are flexible and can accept numerous types of mortice cylinders to suit varied commercial and industrial applications and functions. Key Switches provide a practical, cost effective means for authorized personnel to control and signal various functions within a complex. APPLICATION Key Switches will control rolling shutters, grilles, screens and overhead doors which require both an up and a down command. They are constructed for high frequency use, and will accept any standard mortise cylinder.

CAST ALUMINUM KEY SWITCH CONTROLS ARCHITECTS / ENGINEERS SPECIFICATONS Key switch controls are available in both a recessed (flush) mount and surface mount with weather and vandal proof cast aluminum box and rubber weather seal. The faceplate will incorporate a mounting platform for both the cylinder and switches, in a single piece construction. The faceplate will have 180 locators so that set screws shall not be required to prevent the cylinders from rotating. Only a brass cylinder lock ring will be employed to hold the mortise cylinder to the faceplate. The one piece ¼ thick aluminum assembly shall be tamper and vandal resistant, with a countersunk cylinder opening and the edges beveled. The key switch shall be supplied with stainless steel Torx or snake eye security screws. The one piece faceplate with casted mounting platform will have two holes for switch mounting. It shall be possible to select either left or right operation. In areas requiring dual control, two switches shall be used offering bi-directional operation from the same key switch. The switch used will be a UL/CSA approved type, rated for 6A/125V AC, and 3A/250V AC. The switch must be protected from accidental damage from the cylinder cam, by having an integral metal centre rib incorporated into the design of the faceplate. ORDERING INFORMATION Recessed Key switches are supplied with a brushed aluminum cast faceplate, brass key cylinder with Schlage keyway, brass cylinder lock ring, 2 socket/slotted screws and 2 tamperproof screws with a bit for the tamper proof screws. Surface Key Switches are supplied with a brushed aluminum cast faceplate, cast aluminum electrical box, rubber weather seal, brass key cylinder with Schlage keyway, brass cylinder lock ring, 4 socket/slotted screws and 4 tamper proof screws with a bit for the tamper proof screws. For orders with multiple key switches, the cylinders can be ordered keyed alike. MODEL ER ES DESCRIPTION Recessed Key Switch Surface Key Switch

SECURITY E SHUTTERS S H U TTER S Wiring Diagram for Key Switch NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, and the following instructions. CAUTION: Risk of electrical shock. Disconnect power before installing. Never wire energized components. WARNING DO NOT wire more than one operator to a single pole switch without an isolation control. DO NOT connect more than one switch to an operator without an isolation control. If your application requires more than one switch for each motor, or you want to control more than one motor with one switch, refer to isolation control instruction sheet. The motor warranty is subject to cancellation if the above instructions are not followed. PRECAUTIONS: Select conductors having 90 C or higher rated insulation having sufficient ampacity in accordance with the 60 C column of National Electric Code Table 310-16 or Canadian Electric Code Table 2. Power from Source 120VAC Black Neutral White Ground Green Motor Leads Direction 1 Direction 2 Neutral Motor Ground Shutter Ground MOTOR BLACK Red Standard Motor Black White Green LG Green LG GREEN (Shutter Ground) This extra ground wire is to ensure that the shutter is properly grounded to prevent electrical shock. Connect this wire to the same ground as the motor ground in the motor cable. MOTOR BLACK (Direction 2) MOTOR RED (Direction 1) Power from source GREEN (Motor Ground) WHITE (Neutral) Black (120V - 60Hz JUMPER WIRE E WD-2 Your Co n fide n ce Secured