Manual BC20 Control Service Guide

Similar documents
BULLETIN # B

INTAC Microprocessor Humidifier Controller

Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS

ERROR MESSAGES: Click on Error for further detail PROBE ERROR: PROBE IS OPEN OR NOT CONNECTED.

vacon 100 flow ac drives application manual

TC 204 Heating Controller

vacon 100 flow ac drives application manual

R PROFLAME Instruction Book Collection

Model 12200A RCN PTAC/PTHP/FAN COIL CONTROL NODE OPERATION OUTPUTS G1 = FAN 1 G2 = FAN 2 G3 = FAN 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR

electrical components

Operator Manual 1.4 FRACSIM MINI

INSTRUCTION MANUAL Redox sensor M 1322 C

LIGHT- INDUSTRIAL SLIDING GATE OPERATORS

The Smallest, Quietest & Safest Garage Door Operator in the World!

D3000 Installation Guide

Click Here for Live Online Chat

Fan Coil Actuator FCA 2

534I, 650, 739I, 1200, 1300, 1500, MF28I

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

RWD44U Controller. Installation and Commissioning Guide Document No October 5, Function. Application

Operation Instruction Manual KAM-TC1000. Precision Temperature Controller


Universal Controller

V21 Parts & Service Manual All V21 Identified Equipment REV A 10/2013 P/N: HV3 / CHAMELEON. V Programming HV3 / CHAMELEON P1-1

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

TLC3-BCR-U Series Thermostat

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

Communicative heating controller

CAUTION All safety information must be followed as provided in Service Manual

Quick Start Guide V1.1

User Instructions For TopTronic RS-10

OVEN INDUSTRIES, INC. Model 5C7-362

Relay Driver Overview and Applications

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

Vacon 100 Flow Course

EUROSTER 2026/2026TX

Troubleshooting Guide for Aquatrac Smart AS and Flex

DIGITAL ph / ORP / mv CONTROLLER PMH-2 USERS GUIDE. PMH-2 Instruction manual PAGE 1

1 SAFETY INSTALLATION OPERATION COMPONENTS FAULT DIAGNOSTICS FUNCTIONS TECHNICAL SPECIFICATIONS...

CONTROL MANUAL. Dry-Pic 09PE - 09VE

V22 Thermostat N515/R00( )

User Manual. User manual Version 1.0. Company Information

PHASE CUT SIGNAL DRIVERS

Self-learning Room Temperature Controller Receiver

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

ITV. Spare parts suitable for: Spare parts suitable for ice-cube machines

Model No. DFC Support DIGITAL ENHANCED GAS FIRED MODULATING CONTROL

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

HP 33120A Function Generator / Arbitrary Waveform Generator

SmartZone-2 & SmartZone-4

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

GV60 PLUS. GV60 PLUS Electronic Ignition Remote Control. used on Valor heaters of Series Portrait, Horizon, H4, G3, L1, L2, L3, MF and RFD

2016 Motorized Shades Basic Programming

beginning with version 1.01

TROUBLE SHOOTING FOR 1001-A SERIES REMOTES

STC-KNX (32-channel AP)

Conductivity +/ 2% 1 or 2 point remotely through PLC or directly on board. Any two lead Conductivity probe (K 0.01, K 0.1, K 1.

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

Master Series Electric Xpress Grills

Control panel touch screen MOD. 80

KNX ENO 634 (32-channel AP)

vacon 100 ac drives application manual

PIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

vacon 100 hvac ac drives application manual

The CM Range. Clearly different

KNX manual 1-channel flush-mounted switch actuator SU 1

for SUNNEN TUBE HONING MACHINES HTC SERIES Version: VC-40 50/ VCSC11 30, V -6.43/44b File: CME-V643 Date: 15 March, 2006

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

CG-503 OPERATION MANUAL

Chapter5 Camera Settings and Other Functions

AEROCONNECT 1B NA C Control manual

Please enter the identity code of your device here!

Instruction Notes for 108A L Sensor Input

Guidelines to Using a Three Phase Voltage Monitor

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

Kurz Instruments Inc. 19 August 2010

The keypad is used to set the flowmeter. The function of the keys are as follows: This key selects the figures to be changed.

Operation. Section 4. Additional Information. Operation 4-1

The MFT B-Series Flow Controller.

NX Series Inverters. HVAC Pocket Programming Guide

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION

GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES

WELCOME TO BINGO CALLER

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

TA-Slider 160 KNX R24 Protocol Implementation

Control module 2 circuits AD290. Installation and Service Manual

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

DIGITAL CONTROL UNIT FOR THERMAL SOLAR SYSTEMS

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

1 Digital input (24Vac or dry contact) Inputs

How it works... 3 Key features... 3 Specifications... 3

RADIO DRIVER. * _Rev.1* Installation guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 5

Océ User Manual. Océ CS550/CS6xx Pro Calibration

Transcription:

Manual BC20 Control Service Guide To Access the following menus, with the in the OFF mode, press and hold the upper encoder (Timer Knob) until "0000" appears. Then turn the encoder till the first number of the desired code appears, and push in the knob to proceed to the next number. Continue until the code is entered and push in the knob to access the menu associated with the code. 1 P a g e

Factory Programming: Code = 3228 Parameter Selection Description Default Value Setting BC20G P-01 Temperature Unit (F/C) F P-02 Cool Down Temp 100F P-03 Ready Beep ON P-04 Fan Reversal Time 00:00 (No reverse) P-05 Cook Done Beeper Yes P-06 Delime Interval 30 Hours P-07 Flush Interval 24 Hours P-08 Appliance Type Gas P-09 Machine Type BC20 P-10 Max Steam On Demand Time 20 P-11 Min Hot Air Set Point 140F P-12 Man Hot Air Set Point 500F P-13 Min Steam Set Point 85F P-14 Max Steam Set Point 225F P-15 Max Core Probe Pull Temp 200F P-16 Upper Hot Air Hysteresis 2F P-17 Lower Hot Air Hysteresis 2F P-18 Upper Steam Hysteresis 2F P-19 Lower Steam Hysteresis 2F P-20 Upper Ready Band 25F P-21 Lower Ready Band 10F P-22 Cavity Probe Offset 0F P-23 Core Probe Offset -2F P-24 Boiler Duty Cycle % 33 P-25 User Response Timeout 5 P-26 Sleep Mode Timeout 1 P-27 Counter Start Delay 2 P-28 Quench Probe NO P-29 SCK Address 30 P-30 Act Oven Temp Display NO P-31 Remote Beeper YES P-32 Calibrate Cavity Set Temp CCDR/CDR End Exit Factory Programming END 2 P a g e

Manager Programming: Code = 6647 Parameter Selection Description Default Value Setting BC20G P-01 Temperature Unit (F/C) F P-03 Ready Beep ON P-04 Fan Reversal Time 00:00 (No reverse) P-05 Cook Done Beeper Yes P-25 User Response Timeout 5 P-26 Sleep Mode Timeout 1 P-27 Counter Start Delay 2 P-31 Remote Beeper YES P-32 Calibrate Cavity Set Temp CCDR/CDR End Exit Factory Programming END Service Access: Code = 7378 CNT (Count) Count Number Count Description C-01 Heat-Hot Air Time C-02 Heat-Boiler Time C-03 High Float Counts C-04 Low Float Counts C-05 Drain Counts C-06 Fill Valve Counts C-08 Quench Valve Counts C-09 Motor Reversal Counts C-10 Motor Gentle Time C-11 Motor Low Time C-12 Motor High Time C-13 Motor Turbo Time C-14 Door Counts C-16 Delime Pump Time C-17 Preheat Thermostat Counts C-18 Steam Time C-19 Combi Time C-20 Hot Air Time C-21 Cavity Hi Limit C-22 Boiler Hi Limit Counts C-23 Cavity Probe Error Counts C-24 Delime Counts C-25 Delime Cancel Counts 3 P a g e

C-26 Flush Counts C-27 Flush Cancel Counts DIAG (Diagnostics) Diagnostic Number Diagnostic Test D-01 Cavity Heat Relay D-02 Boiler Heat Relay D-03 Water High Level Float Status D-04 Water Low Level Float Status D-05 Drain Relay D-06 Fill Relay D-07 Steam Relay D-08 Quench Relay D-09 Motor Reversal Relay (Gentle Speed) D-10 Motor Gentle D-11 Motor Low D-12 Motor High D-13 Motor Turbo D-14 Door Status D-15 Lights Relay D-16 Delime Pump Relay D-17 Software Flash Number D-18 Software Number D-19 Software Download Number D-20 SIB Software Number D-21 Cavity Set Temperature D-22 Cavity Act Temperature D-23 Cooling Fan Probe Temperature D-24 Quench Probe Temperature D-25 Core Probe Temperature D-26 Boiler Probe Temperature D-27 Main Switch D-28 Fan Feedback Input D-29 Cook Done Relay D-30 Vent Relay D-33 Cool Fan Relay D-34 Hot Air Relay D-35 Hot Air Enable Relay D-37 All Relays D-38 Display and LED Test END 4 P a g e

Below are the Error Codes the control can display and their meaning: Code Meaning E-01 Cavity Probe Error - The reading from the probe is registering less than 32F or greater than 675F. E-02 Boiler Probe Error - The reading from the probe is registering less than 32F or greater than 575F. E-03 High Float Error - The High Level switch has not opened after 15 minutes of FILL output from the control. E-04 Low Float Error - The Low Level switch has not opened after 15 minutes of FILL output from the control. E-05 Communication Error - The control lost signals from the relay board for 3 seconds. E-06 Cooling Fan Probe Error - The reading from the probe is registering less than 32F or greater than 575F. E-07 Delime Error - The Level Switches do not close after 10 minutes of Drain output. OR the Level Switches do not Open after 10 minutes of Fill output. E-08 Cavity High Temp Error - Up to Rev J: If the cavity probe reads 565F or over 150F above set point. Rev K and up: If the cavity probe reads 665F (to 674) this error will occur. E-09 Boiler Over Temp Error - The boiler probe is reading greater than 220F. E-10 Quench Probe Error - The reading from the probe is registering less than 32F or greater than 575F. E-11 Fill Valve Error - The High AND Low Level Switches do not open after 15 minutes of Fill Output. E-12 Fan Error - The Drive at Speed input was missing for 15 seconds. E-13 Meat Probe Error - The reading from the probe is registering less than 675F and greater than 565F. E-14 Flush Error - The High AND Low Level Switches do not close after 10 minutes of Drain Output. 5 P a g e

Also note the following functions: To Manually Flush the Unit: To initiate the flush process the user turns the mode switch to COOL DOWN and pushes in the upper encoder knob (3 seconds) until display scrolls message FLUSHING, flush cycle is started. During display scrolling message FLUSHING, the display scrolls message CLOSE DOOR and beeper is one once every second if the door is opened. To Manually Delime the Unit: To initiate the Delime process the user turns the mode switch to COOL DOWN and pushes in the lower encoder knob (3 seconds) until the DELIME LED flashes at 5 times per second. The user then turns the mode switch to the OFF position. To Manually Prime the Delime Pump: To initiate the Pump the user turns the mode switch to COOL DOWN and pushes in the lower and upper encoder knobs together which activates the pump. When primed, release the knobs and turn the unit OFF. 6 P a g e