Straight Isolation - Hard Wired (169 Series)

Similar documents
Straight Isolation - Plug In (171 Series)

Amveco Toroidal Solutions. Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications.

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Differential Probes P6248 P6247 P6246 Datasheet

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

2.1. Product Description

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

High-voltage Differential Probes

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

HPS Universal BUCK-BOOST TRANSFORMERS

Passive High Voltage Probes P5100 P5102 P5120 P6015A

Power Processor - Series 700F 10KVA to 150KVA

BUCK-BOOST TRANSFORMERS

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

Steps for Selecting the Proper Transformer

Tube Driver - Interstage (124 Series)

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

T S 15KVA 1PH 240/480 Transformer

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

Established 1942 Quality Service Competitive Prices Single Phase Transformers Three Phase Transformers Open frame or Enclosed Smoothing Chokes

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

Encapsulated Transformers 115V + 115V Primary, Low Profile

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

StatiVolt. Inverter UPS Systems. Features. Contents

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

Power-Sure 700. Technical Data TD158001EN. Contents

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

PRODUCT DATA. Falcon Range 1/4-inch Microphone Preamplifier Type 2670

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

MAJORSINE Power Inverter

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

1.5 GHz Active Probe TAP1500 Datasheet

PRODUCT DATA. Sound Intensity Calibrator Type 4297

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

TOSHIBA International Corp

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

General Description & Features Selection Charts Definition of Terms... 42

Agilent U9397A/C FET Solid State Switches (SPDT)

Power Conditioners product guide

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

Agilent U1700 Series Handheld LCR Meters

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

PERFORMANCE SPECIFICATION SHEET TRANSFORMERS, AUDIO FREQUENCY, MICRO-MINIATURE

Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note.

Isolation Addresses Common Sources of Differential Measurement Error

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

ULTRA-K Series 600K - he

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description

Drives 101 Lesson 5. Power Input Terminology for a VFD

Keysight Technologies N4985A System Amplifiers

Dry-Type Transformers

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

DOBLE F6150e TECHNICAL SPECIFICATIONS

TSM100 SINGLE OPERATIONAL AMPLIFIER AND SINGLE COMPARATOR

Three-Phase Transformer Turns Ratio Tester TRT03B

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

Energy Efficient Distribution Transformers

S3 Series. Standard Recovery Power Diodes. Features: Mechanical Data: SMC/DO-214AB. Foot Print. Dimensions. Page 1 27/03/06 V1.0

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Agilent 87075C Multiport Test Set

46 GBaud Multi-Format Optical Transmitter OM5110 Datasheet

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center

Arbitrary/Function Generator AFG1000 Series Datasheet

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

True Three-Phase Transformer Turns Ratio Tester TRT30A

Agilent U9391C/F/G Comb Generators

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

AC Current Probes CT1 CT2 CT6 Data Sheet

Using the Ramp Rate Method for Making Quasistatic C-V Measurements with the 4200A-SCS Parameter Analyzer APPLICATION NOTE

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

ENCOUNTER AMPLIFIER MANUAL EN-1502 EN-3001 EN-3004

TRANSFORMERS CHASSIS TANSFORMERS FERRITE ROD 2328 LIGHTING TRANSFORMERS 2328 TOROIDAL TRANSFORMERS 2327 TRANSFORMERS

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

BZW06- Series DO-15. Mechanical Data. Page <1> 14/05/08 V1.1

True Three-Phase Transformer Turns Ratio Tester TRT40A

AC/DC Current Measurement Systems

General Purpose Transformers

Transcription:

LINE ISOLATION TRANSFORMERS (115V to 115V) Primary 115C, 60 Hz., Secondary 115C Electrostatic shield between primary & secondary Connection by flexible leads, 8" minimum length Perfect for circuit isolation or "Classic" bias power supply CSA certified (# LR3902) Remember - These units do NOT convert line frequency Straight Isolation - Hard Wired (169 Series) Transformer Schematic Primary Blk Yel Blk Yel Secondary Sec. Current ma A B C D E Lbs. 169PS 15 130 1.88 2.07 2.50 1.50 1.19 1.3 169QS 40 260 2.19 2.50 2.63 1.75 1.44 2.5 169RS 60 435 2.50 2.75 3.06 2.00 1.69 3.3 169SS 90 650 2.50 3.25 3.06 2.00 2.19 4.5 169TS 135 870 3.13 3.50 3.81 2.50 2.19 6.5 169VS 175 1300 3.13 4.00 3.81 2.50 2.69 7 169WS 250 1700 3.75 4.00 4.56 3.00 2.81 12 LINE ISOLATION - TAPPED TRANSFORMERS (115V to 90-130V) Primary 115C, 60 Hz. Secondary taps @ 90, 100, 110, 115, 120 & 130C Electrostatic shield between primary & secondary Connection by flexible leads, 8" minimum length Perfect for critical line voltage needs (ex. Japanese 100V equipment). CSA certified (# LR3902) - except 169J Remember - These units do NOT convert line frequency Transformer Schematic 115V Primary Blk Blk 130V Red 120V Grn 115V Brn 110V Yel 100V Blk/Red 90V Blk/Yel Secondary Lbs. A B C D E 169C 100 2.50 3.50 3.06 2.00 2.44 4 169E 250 3.75 4.00 4.56 3.00 2.81 7 169G 500 6.75 5.50 4.56 3.00 4.31 15 169J 750 4.38 6.13 5.25 3.50 4.50 22 0V Blu

Straight Isolation - Plug In (171 Series) LINE ISOLATION PLUG & RECEPTACLE TRANSFORMERS (115V to 115V) Primary 115C, 50/60 Hz., Secondary 115C Electrostatic shield between primary & secondary. Hi-pot tested to 2 KV RMS. Circuit breaker in primary. Standard 3-wire, grounded plug & receptacle. Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P). Output (secondary) connected to 1 foot long 3-wire, standard North American grounded receptacle (NEMA 5-15R). North American Mark of Safety - C UL & UL listed (File #E211544) Remember - These units do NOT convert line frequency Primary 3-wire plug Secondary 3-wire receptacle A B C D E Lbs. 171A 100 3.80 5.06 4.68 3.00 3.38 6.5 171B 200 3.80 5.56 4.68 3.00 3.88 8 171C 300 3.80 6.06 4.68 3.00 4.38 11 171E 500 3.80 7.06 4.68 3.00 5.38 14 171F 750 4.40 8.70 5.39 3.50 6.78 30 171G 1000 5.28 7.75 6.38 4.25 4.38 34.5

Toroidal Straight Isolation - Plug In (178 & 240 Series) Toroidal Isolation Plug In (120V to 120V) Primary 120C, 50/60 Hz., Secondary 120C. Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step down (120C to 120 C). Standard 3-wire, grounded plug (for use with adaptors for proper grounding). Input (primary) connected to a 5 foot long cord & standard North American plug (NEMA 5-15P). Output (secondary) connected to two standard 3 wire grounded receptacles (NEMA 5-15R). Features include ventilated black steel case, rocker lighted on-off switch & circuit breaker protected output. North American Mark of Safety - C UL & UL listed (File #E211544). Remember - These units do NOT convert line frequency. # of Outlets Length Width Height 178CT 250 2 8.25 6.00 4.00 178DT 500 2 9.00 6.00 4.00 178ET 750 2 10.25 7.50 5.00 178FT 1000 2 10.25 7.50 5.00 178GT 1500 2 12.50 9.00 5.00 Toroidal Isolation Plug In (240V to 240V) Primary 240C, 50/60 Hz., Secondary 240C. Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step down (240C to 240C). Standard 3-wire, grounded plug (for use with adaptors for proper grounding). Input (primary) connected to a 5 foot long cord & standard North American plug (NEMA 6-15P). Output (secondary) connected to a standard 3 wire grounded duplex receptacle (NEMA 6-15R). Features include ventilated black steel case, rocker lighted on-off switch & circuit breaker protected output. North American Mark of Safety - C UL & UL listed (File #E211544). Remember - These units do NOT convert line frequency. # of Outlets Length Width Height 240CT 250 2 8.25 6.00 4.00 240DT 500 2 9.00 6.00 4.00 240ET 750 2 10.25 7.50 5.00 240FT 1000 2 10.25 7.50 5.00 240GT 1500 2 12.50 9.00 5.00

Straight Isolation - Constant Voltage - Plug In (CV Series) Constant Voltage A.C. Regulator - Plug In (120 V to 120V) AC regulating - protects against both brownouts & over voltage conditions. Protects against any power problem other than a blackout. Will operate through a 3 millisecond (minimum) blackout. Long life - ferroresonant design - no moving parts. Ferroresonant design also filters out surges, line harmonics, and RF noise. Input 120C (+10 % to -25 %), 60 Hz Output 120C (+/- 3 %). Noise Isolation (RF) of 120 db common mode, 60 db normal mode. Spike attenuation: 250:1 minimum. Sine wave output - total harmonic distortion (THD): 3 % Units also include a 2nd stage of high frequency filtering on the output - a Hammond Mfg. exclusive. Operating temperature range of -40 degrees C to +40 degrees C. Standard 3-wire, grounded plug & receptacle. Front panel lighted power switch. Input (primary) connected to an extra long 15 foot, heavy duty 14/3 SJTW cord for extreme temperature ranges. Integral molded, standard North American plug (NEMA 5-15P). Output (secondary) connected to a rear mounted, standard North American, grounded receptacle (NEMA 5-15R) - quantity depends on power capacity of unit (see table below). Rugged two piece ventilated steel enclosure. Finished in a grey/beige color, textured powder paint with rubber feet installed. NOTE 1: Due to the nature of ferroresonant designs - these units do produce audible noise. We have reduced this through careful design, but these units are NOT usable in an office environment. NOTE 2: These units provide complete isolation from the source voltage. In other words, the "neutral" output wire has no connection to ground, this is a UL requirement for this type of device. Therefore plug-in circuit testers & line "polarity" testing devices will NOT function on the output as it is completely isolated. North American Mark of Safety: C UL & UL listed (File #E211544). Number of Amps Rear Outlets Height Width Depth Lbs. (RMS) CV120300 300 2.5 2 7.00 7.13 12.30 25.3 CV120600 600 5 4 9.00 10.13 19.50 48 CV1201200 1200 10 4 9.00 10.13 19.50 74 CV1201800 1800 15 6 12.00 12.13 20.50 95

Toroidal Isolation - Step Up - Plug In (298 Series) LINE ISOLATION STEP UP - PLUG IN (120V to 240V) Primary 120C, 50/60 Hz., Secondary 240C. Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step UP (120C to 240 C). Standard 3-wire, grounded plug (for use with adaptors for proper grounding). Input (primary) connected to a 5 foot long cord & standard North American plug (NEMA 5-15P). Output (secondary) connected to a standard N. American duplex - 3 wire grounded receptacles (NEMA 6-15R). Features include ventilated black steel case, rocker lighted on-off switch & circuit breaker protected output. North American Mark of Safety - C UL & UL listed (File #E211544). Remember - These units do NOT convert line frequency. # of Outlets Length Width Height 298CT 250 2 8.25 6.00 4.00 298DT 500 2 9.00 6.00 4.00 298ET 750 2 10.25 7.50 5.00 298FT 1000 2 10.25 7.50 5.00 298GT 1500 2 12.50 9.00 5.00

Isolation - Step Down - Plug In (172 & 289 Series) LINE ISOLATION - STEP DOWN PLUG-IN TRANSFORMERS (230V to 115V) Primary 230C, 50/60 Hz. Secondary 115C Circuit breaker in primary. Provides circuit isolation & steps down primary voltage. Hi-pot tested to 2 KV RMS. Electrostatic shield between primary & secondary. Input (primary) connected to a 5 foot long cord & North American 250V, 3-wire grounded plug (NEMA 6-15P). Output (secondary) connected to a 1 foot long cord & standard North American 125V, 3-wire grounded receptacle (NEMA 5-15R). North American Mark of Safety - C UL & UL listed (File #E211544). Remember - These units do NOT convert line frequency A B C D E Lbs. 172A 100 3.80 5.06 4.68 3.00 3.38 6.5 172B 200 3.80 5.56 4.68 3.00 3.88 8.5 172D 500 3.80 7.06 4.68 3.00 5.38 18.5 172E 750 4.40 8.70 5.39 3.50 6.78 30.0 172F 1000 5.28 7.75 6.38 4.25 4.38 34.5 LINE ISOLATION - TOROIDAL STEP DOWN - PLUG IN (240V to 120V) # of Outlets Length Width Height 289CT 250 2 8.25 6.00 4.00 289DT 500 2 9.00 6.00 4.00 289ET 750 2 10.25 7.50 5.00 289FT 1000 2 10.25 7.50 5.00 289GT 1500 2 12.50 9.00 5.00 Primary 240C, 50/60 Hz., Secondary 120C. Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. World wide applications, 50 or 60 Hz. operation, step down (240C to 120 C). Standard 3-wire, grounded plug (for use with adaptors for proper grounding). Input (primary) connected to a 5 foot long cord & standard 250V 2 pole, 3 wire - North American plug (NEMA 6-15P). Output (secondary) connected to two standard 125V, 3-wire grounded receptacles (NEMA 5-15R). Features include ventilated black steel case, rocker lighted on-off switch & circuit breaker protected output. North American Mark of Safety - C UL & UL listed (File #E211544) Remember - These units do NOT convert line frequency

Isolation - Step Down - Plug In (179 Series) LINE ISOLATION STEP DOWN - PLUG IN (115V to 95V) Primary 115C, 50/60 Hz., Secondary 95C. Electrostatic shield between primary & secondary. World wide applications, 50 or 60 Hz. operation, step down (115C to 95C). Designed mainly for Japanese equipment operating in North America. Perfect for operating "Classic" equipment that can not tolerate todays higher line voltages (ie..125c input will produce a stress free 105C output - at full load - PLUS - isolation and shielding). Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding). Input (primary) connected to a 5 foot long cord and standard 3-wire, 125V North American plug (NEMA 5-15P). Output (secondary) connected to two standard 3-wire, 125V grounded receptacles (NEMA 5-15R). Features include ventilated black steel case, rocker lighted on-off switch & fuse protected output. Remember - These units do NOT convert line frequency # of Outlets Length Width Height 179C 250 2 6.00 6.75 4.75 179D 500 2 6.00 8.25 4.75 179E 750 2 7.00 8.25 5.38 179F 1000 2 7.00 9.75 5.38 179G 1500 2 8.50 9.00 6.75 Output 3-wire receptacle (2) Input 3-wire plug

"Auto" - Hard Wired (170 Series) HARD WIRED LINE AUTOTRANSFORMERS Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. Flexible world wide applications, 50 or 60 Hz. operation, step down (230C to 115 C) or step up (115C to 230C). Connection by flexible leads, 8" minimum length. Models 170A, 170B, 170C & 170D are CSA certified (# LR 3902). Remember - These units do NOT convert line frequency. Lbs. A B C D E 170 50 2.19 2.63 2.63 1.75 1.56 2 170A 100 2.50 3.00 3.06 2.00 1.94 3 170B 200 3.13 3.50 3.81 2.50 2.19 4.5 170C 300 3.13 4.00 3.81 2.50 2.69 6 170D 500 3.75 4.50 4.56 3.00 3.31 10 170E 750 3.75 5.50 4.56 3.00 4.31 14 170F 1000 3.75 5.50 4.56 3.00 4.31 14.5 170G 1500 4.38 6.63 5.30 3.50 5.10 22 170J 2000 4.38 6.63 5.25 3.50 5.10 23 230V Red 115V Blk 0V Yel HARD WIRED LINE AUTOTRANSFORMERS Lbs. A B C D E 170SE 50 3.13 4.00 4.13 2.25 3.13 3.5 170AE 100 3.13 4.00 4.13 2.25 3.13 4 170BE 200 3.13 4.25 4.13 2.25 3.38 5 170CE 300 3.13 4.75 4.13 2.25 3.88 6.5 170DE 500 3.75 5.00 4.88 2.75 4.13 10 170EE 750 3.75 6.00 4.88 2.75 5.13 15 170FE 1000 3.75 6.00 4.88 2.75 5.13 15.5 170GE 1500 4.38 7.00 5.50 3.25 5.88 23.5 170JE 2000 4.38 7.00 5.50 3.25 5.88 24.0 Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. Flexible world wide applications, 50 or 60 Hz. operation, step down (230C to 115 C) or step up (115C to 230C). Totally enclosed rear case, includes handy internal grounding bolt. Extra vacuum varnish for use in high humidity. Includes a rear mounted (but not wired), standard 115C, 3-wire receptacle. Enclosed case with convenient knockouts and includes two cable clamps allowing for easy wire connections. Models 170SE, 170AE, 170BE, 170CE & 170DE are CSA certified (# LR3902) Connection by flexible leads, 8" minimum length Remember - These units do NOT convert line frequency. 230V Red 115V Blk 0V Yel

"Auto" - Hard Wired (168 Series) HARD WIRED LINE AUTOTRANSFORMERS Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. Flexible world wide applications, 50 or 60 Hz. operation, 115C input. Output taps @ 85, 95, 105, 110, 115 and 125C. Ideal for manual line voltage adjustment for electronic equipment or small appliance operation. Models 168B, 168C & 168D are CSA certified (# LR3902) Connection by flexible leads, 8" minimum length. Remember - These units do NOT convert line frequency. Lbs. A B C D E 168B 200 3.13 3.25 3.81 2.50 1.94 4.3 168C 350 3.13 4.00 3.81 2.50 2.69 6.5 168D 500 3.75 4.00 4.56 3.00 2.81 8 168E 750 3.75 4.50 4.56 3.00 3.31 10 168F 1000 3.75 5.50 4.56 3.00 4.31 14 168H 1500 4.38 6.13 5.25 3.50 4.50 20 168J 2000 4.38 6.63 5.25 3.50 5.10 23 125V Orn 115V Yel 110V Red 105V Grn 95V Brn 85V Wht 0V Common Blk

"Auto" Step Down - Plug In (175 Series) PLUG IN - STEP DOWN AUTOTRANSFORMERS (230V to 115V) Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. World wide applications, 50 or 60 Hz. operation, step down (230C to 115C). Input is circuit breaker protected. Hi-pot tested to 2 KV RMS. Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding). Input connected to a 5 foot cord & grounded North American 250V 3-wire plug (NEMA 6-15P). Output connected to standard North American 115V - 3 wire grounded receptacle (NEMA 5-15R). North American Mark of Safety - C UL & UL listed - File #E211544 Remember - These units do NOT convert line frequency. A B C D E Lbs. 175A-NA 100 3.16 4.25 3.81 2.50 2.94 3.5 175B-NA 200 3.16 4.50 3.81 2.50 3.19 4.5 175C-NA 300 3.16 5.00 3.81 2.50 3.69 6 175D-NA 500 3.80 6.00 4.68 3.00 4.38 10 175E-NA 750 3.80 7.06 4.68 3.00 5.38 14 175F-NA 1000 3.80 7.06 4.68 3.00 5.38 14.5 175G-NA 1500 4.40 6.63 5.39 3.50 6.09 22

"Auto" Step Up - Plug In (176 Series) Autotransformer Step Up - Plug In (115V to 230V) Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. World wide applications, 50 or 60 Hz. operation, step up (115C to 230C). Input is circuit breaker protected. Hi-pot tested to 2 KV RMS Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding). Input is connected to a 5 foot cord & standard grounded 125V North American plug (NEMA 5-15P) Output is connected to a grounded North American 250V receptacle (NEMA 6-15R). North American Mark of Safety - C UL & UL listed (File #E211544) Remember - These units do NOT convert line frequency. A B C D E Lbs. 176A 120 3.16 4.25 3.81 2.50 2.94 3.5 176B 200 3.16 4.50 3.81 2.50 3.19 4.5 176C 300 3.16 5.00 3.81 2.50 3.69 6 176D 500 3.80 6.00 4.68 3.00 4.38 10 176E 750 3.80 7.06 4.68 3.00 5.38 14 176F 1000 3.80 7.06 4.68 3.00 5.38 14.5 176G 1500 4.40 6.63 5.39 3.50 6.09 22

Transformers - Accessories INTERNATIONAL - GROUNDED ADAPTOR PLUGS For use with our 171, 172, 175, 176, 179, 289 & 298 transformers. Heavy duty design with plastic shell & double wipe contacts. Allows for ground connection between equipment and international power sources. With a set of all 4 adaptors, they will accept equipment with plugs from virtually every country except South Africa! Adaptors do not affect voltages, they are a mechanical device only to match foreign "pinouts" of receptacles and/or plugs. Grounded Plug Type Used in the Countries of: 298G4 European Austria, Belgium, Finland, France, Germany, Middle East, Netherlands, Norway, s of Africa/Asia/South America/China/Tahiti & Caribbean, Sweden 298G3 British Hong Kong, Ireland, Malaysia, s of Africa, Caribbean, Singapore, U.K. 298G6 Australian Australia, People s Republic of China, S. Pacific Islands, New Zealand 298G7 N. American Canada, s of the Caribbean/South America, Philippines, USA Rear View of all adaptors 298G4 298G3 298G6 298G7

Transformer - Selection Guide Steps To Proper Transformer Selection 1. 2. 3. 4. What power is available (you need to know both voltage & frequency)? Check the operating voltage of your equipment (is it single voltage or multiple?). What line frequency will your equipment run on? Either 50, 60 or dual 50/60 Hz. (remember, a transformer can NOT change line frequency). Use the chart below to determine your requirements: Power Available Your Equipment Transformer Type Required Voltage Frequency Voltage Frequency (You may also need plug adaptors) 115 60 100 50/60 Step Down 115 50 115 50 None Required - or - Straight Isolation 115 50 115 60 Will Not Work 115 50 115/230 50/60 None Required - or - Straight Isolation 115 60 115 60 None Required - or - Straight Isolation 115 60 230 50 Will Not Work 115 60 230 60 Step Up 115 60 115/230 50/60 None Required - or - Straight Isolation 230 50 115 50 Step Down 230 50 115 60 Will Not Work 230 50 115/230 50/60 None Required - or - Straight Isolation 230 60 115 60 Step Down 230 60 230 50 Will Not Work 230 60 230 60 None Required - or - Straight Isolation 230 60 115/230 50/60 None Required - or - Straight Isolation 1. Determine if your equipment is Electronic or Electrical: - Electronic = containing IC chips, transistors or a circuit such as a radio, shavers, electric toothbrush, computer printers, camcorder battery rechargers etc...(if in doubt, check with the manufacturer or refer to your manual). - Electrical = Simple heating device, such as irons, hair dryers, electric blankets, curling irons, etc... 2. Use the chart below to locate correct series & voltage conversion in the catalog series that follow: Transformer Type (determined from Your Equipment Type chart above) Electronic Electrical Step Up Use Isolation (series 298) Could use Auto (series 170 or 170E) Step Down Use Isolation (series 172, 179 or 289) Could use Auto (series 175) Straight Isolation Use Isolation (series 169 or 171) - IMPORTANT NOTES Isolation Transformers: Used for maximum safety, versatility (can be used on both electrical & electronic equipment) and isolation from the power source, used to step-up, step-down or for straight isolation. The disadvantage to using them is weight (about double the "Auto"), more expensive and larger size. This type of transformer is sometimes referred to as "double-wound" "Auto" Transformers: are non-isolating units and should be used where only a voltage change is required. The advantages to using them are light weight (generally half that of an isolation unit), less expensive and smaller size. The disadvantage is no isolation from the power source. This type of transformer is sometimes referred to as a "converter". Adaptors: We strongly recommend that 3-prong "grounded" plugs be used with all of our products. They should be used only with our "grounded" adaptors. Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.