Safety detection solutions Preventa

Similar documents
SAFETY LIGHT CURTAINS

Safety Light Curtain Orion1 Extended

MiniSafe Light Curtains

series. Safety sensor for Palletisers. Features. For Palletiser. 3 Different types available. Active - Passive system and Plug and play

SF4-AH SERIES. Small Light Curtain Type 4. Compact size of mm in Type 4 light curtain ORDER GUIDE.

Technical data. General specifications. Transducer frequency Indicators/operating means

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Technical data. General specifications. Transducer frequency Indicators/operating means

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

F3SN-A & F3SH-A. Safety Light Curtain & Multiple-beam Safety Sensor

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

F3SJ-B. Safety Light Curtain. Basic Type with a combination of performance and functionality. Ordering Information. Main Units Safety Light Curtain

panasonic-electric-works.net/sunx Type 2 safety solution International regulations for safety measures at reasonable cost

Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

Online data sheet STR1-SASM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Absolute Encoders Multiturn

Safety Light Curtain / Multi-beam Safety Sensor. Sense the Difference, Make a Difference!

Lexium integrated drives

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

Protection components

Three models available: Relay output with 24 VDC power input Relay output with 85 to 250 VAC power input Solid-state output with 24 VDC power input

Photo-electric sensors

References 1 for asynchronous motors 1

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

Positioning drives DC motor, brushless Absolute multiturn position detection, Profibus-DP

Acceleration sensors With relay output for limit monitoring Analog / CANopen

Absolute Encoders Singleturn

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

QL50 Luminescence Sensor

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

XXXX e. X d.. X X X a

02/11/2015

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

INSTRUCTION MANUAL SF4B- G<V2>

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Rotary Measurement Technology Incremental Encoders

Custom "Compact" range with display CD20 Custom Part number

Absolute Encoders Multiturn

Online data sheet MRS1104C MRS1000 3D LIDAR SENSORS

QUINT-PS/ 3AC/24DC/10

Incremental encoders Blind or through hollow shaft ø12 mm pulses per revolution

MULTI-BEAM LS10 Light Screen System

panasonic-electric-works.net/sunx Supports beam axis alignment at startup and quick restoration in case of trouble

SAFETY LIGHT CURTAINS

FEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3.

em4 em4 alert em4 alert 2G

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

Safety Light Curtain F3SG-R Series

QUINT-PS/ 3AC/24DC/40

02/11/2015

Original operating instructions Fail-safe inductive sensor GG507S

FF-SB Series. Type 4 self-contained light curtain For the protection of operators in Industry FF-SB

Rotary Measuring Technology

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

XXXX e. X d.. X X X a

QL55 Series Luminescence Sensor

Miniature resistance thermometer Model TR33, thread-mounted

Original operating instructions Fail-safe inductive sensor GM705S

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

PHOTOELECTRIC SENSORS. Online data sheet

SISNet Repeater. SISNet Repeater. Introduction. DeltaV SIS Product Data Sheet. Dedicated safety communications. Full communications redundancy

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

Distance sensors. System description. Distance measurement using triangulation

Outside Temperature Sensors

Emergency stops and safety stops

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES

Absolute encoders - analog Blind hollow shaft ø12 mm Magnetic single- or multiturn encoders 12 bit ST / 16 bit MT

QUINT-PS-24DC/24DC/10

Photo-electric miniature sensors OsiSense XUM. Catalogue

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

WORLD-BEAM QS30AF Sensor

Online data sheet. RT-P3221 ZoneControl PHOTOELECTRIC SENSORS

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Absolute encoders - SSI

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

Spring Return DuraDrive Proportional Actuator

Photoelectric Sensors XUV Sensors with Separate Optical Heads

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

POINTAX 6000L2 Point Recorder

CA18CAxxBPxIO - IO-Link

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Type Nominal voltage (V) Code HSV V

em4 local - Robust Specific characteristics Part number

Light Curtain / Type4. SF4B<V2> Series. Instruction Manual WUME-SF4BV panasonic.net/id/pidsx/global

Zelio Control Measurement Relays

Pressure transmitter for general industrial applications Model A-10

Transcription:

Characteristics Light curtain type XUS LPpppp Environmental characteristics Conformity to standards ANSI/RIA R15.06, ANSI B11:19-1990, OSHA 1910.217(C), OSHA 1910.212, EN/IEC 61496-1-2 for type 4 ESPE Certifications e, TUV, UL, CSA European directives Machinery directive 98/37/EC, Work equipment directive 89/655/EEC and EMC directive 89/336 EEC Maximum safety level (1) PL = e/category 4 conforming to EN/ISO 13849-1 SIL 3 conforming to EN/IEC 61508 Reliability data PFH d = 2.7E -9 1/h conforming to EN/IEC 61508 Ambient air temperature Operating C 0 + 55 For storage C - 25 + 75 Relative humidity 95% maximum, without condensation Degree of protection IP 65 and IP 67 Shock and vibration resistance Materials Fixings Conforming to IEC 61496-1 Shock resistance: 10 gn, impulse 16 ms, Vibration resistance: 10 55 Hz, amplitude: 0.35 ± 0.05 mm Casing: aluminium with electrostatically applied red (RAL 3000) polyester paint fi nish; end caps: 20% fi breglass impregnated polycarbonate. Front face: acrylic. End brackets (included) Optical characteristics Minimum detection capacity mm 300, 400, 500, 600 and single beam (Body protection) Nominal sensing distance (Sn) m 0.8 to 20 or 0.8 to 70 depending on configuration and 0.8 to 8 m for light curtains with passive receiver Height protected Depending on number of light beams, see table on page 38131-EN/3 Effective aperture angle (EAA) 2.5 at 3 m Light source aaias LED, 850 nm Immunity to ambient light Conforming to EN/IEC 61496-2 Electrical characteristics Response time ms < 16 < 24 depending on light beam coding selected Power supply c 24 V ± 20% 2 A conforming to EN/IEC 61496 and EN/IEC 60204-1 Transmitter ma 100 (SELV: Safety Extra Low Voltage) Receiver A 1.6 (with maximum load) Maximum current consumption (no-load) Transmitter ma 100 Receiver ma 300 Immunity to interference Conforming to EN/IEC 61496-1 Safety outputs OSSD (Output Signal Switching Devices) 2 solid-state PNP (N/O) outputs 650 ma, c 24 V (Short-circuit protected) Auxiliary output 1 solid-state output 100 ma, c 24 V, PNP Monitoring activation of output switching devices 50 ma, c 24 V (MPCE/EDM) Signalling Transmitter 1 LED (power supply) Receiver 3 LEDs (stop, run, interlock) and a 2-digit display for diagnostics Connections (2) Transmitter M12, 5-pin, male connector or terminal block Receiver M12, 8-pin, male connector or terminal block Conductor c.s.a. Transmitter-receiver pre-wired mm 2 0.35. Tinned wires. connector Cable resistance Transmitter-receiver Ω 0.055 per metre for 0.35 mm 2 c.s.a. cable Cable lengths m Pre-wired connectors with cable lengths of 5, 10, 15 and 30 m are available separately. The maximum cable length is 120 m, depending on the load current and power supply. Functions Functions Monitoring of external switching devices (EDM = External Devices Monitoring) Test function Muting function (inhibition) (1) Using an appropriate and correctly connected control system. (2) Pre-wired female connectors to be ordered separately, see page 30313-EN/5. : - Auto/Manual, manual 1 st cycle, - Monitoring of external switching devices (EDM: External Devices Monitoring), - Test (MTS: Monitoring Test Signal) for XUS LPZ only, - Alignment aid by display of each light beam broken, - Display of operating modes and alarm by LEDs and 2-digit display. Selection of Auto/Manual, relay monitoring, alarm or auxiliary output functions, light beam coding and selection of sensing distance using confi guration switches. Monitoring of the function (open or closed) as well as the response time of the power components. Parameterable using configuration switches. Instigates the stop instruction of the light curtain by opening the contact (simulated intrusion) Possible with external module XPS LCM1150 pages 30313-EN/3 and 30313-2

References, with connector 105558 Transmitter-receiver pairs for body protection (1) Detection capacity 300, 400, 500, 600 mm and single beam. Sensing distance 0.8 to 20 m and 0.8 to 70 m (depending on configuration) b 2 PNP safety outputs Detection capacity Response time Light beam coding Number of light beams Auxiliary output Reference (2) Weight A B C mm ms ms ms kg < 24 < 20 < 16 1 PNP XUS LPZ1AM 4.500 500 < 24 < 20 < 16 2 PNP XUS LPZ2A0500M 6.300 600 < 24 < 20 < 16 2 PNP XUS LPZ2A0600M 6.700 400 < 24 < 20 < 16 3 PNP XUS LPZ3A0400M 7.200 500 < 24 < 20 < 16 3 PNP XUS LPZ3A0500M 8.600 105561 300 < 24 < 20 < 16 4 PNP XUS LPZ4A0300M 8.200 300 < 24 < 20 < 16 5 PNP XUS LPZ5A0300M 9.500 XUS LPZ1AM XUS LPZ3AppppM 300 < 24 < 20 < 16 6 PNP XUS LPZ6A0300M 10.400 (1) Supplied with 2 sets of 2 brackets with fi xings and a user guide with certificate of conformity. Pre-wired female connectors to be ordered separately, see page 30313-EN/5. (2) To order a receiver only, add the letter R to the end of the reference for the corresponding Example: reference XUS LPZ2A0600M becomes XUS LPZ2A0600MR for the receiver only. To order a transmitter only, add the letter T to the end of the reference for the corresponding Example: reference XUS LPZ2A0600M becomes XUS LPZ2A0600MT for the transmitter only. Transmitter-receiver pairs for body protection, with passive receiver(1) Detection capacity 500 and 600 mm. Sensing distance 0.8 to 8 m b 2 PNP safety outputs 105559 Detection capacity Response time Light beam coding Number of light beams Auxiliary output Reference (2) Weight A B C mm ms ms ms kg 500 < 24 < 20 < 16 2 PNP XUS LPB2A500M 6.300 600 < 24 < 20 < 16 2 PNP XUS LPB2A600M 6.700 (1) Supplied with 2 sets of 2 brackets with fixings and a user guide with certificate of conformity. Pre-wired female connectors to be ordered separately, see page 30313-EN/5. (2) To order a passive receiver, replace the letter M by the letter P to the end of the reference for the corresponding Example: reference XUS LPB2A500M becomes XUS LPB2A500P for the passive receiver. To order a transmitter only, add the letter R to the end of the reference for the corresponding Example: reference XUS LPB2A600M becomes XUS LPB2A600MR for the transmitter only. Other versions Combining type 4 safety light curtains with external module for muting function. See pages 30311/2 to 30311/9. XUS LPB2pp 3

References (continued), with terminal block 535341 Transmitter-receiver pairs for body protection (1) Detection capacity 300, 400, 500, 600 mm and single beam. Sensing distance 0.8 to 20 m and 0.8 to 70 m (depending on configuration) b 2 PNP safety outputs Detection capacity Response time Light beam coding Number of light beams Auxiliary output Reference (2) Weight A B C mm ms ms ms kg < 24 < 20 < 16 1 PNP XUS LPZ1AB 4.500 500 < 24 < 20 < 16 2 PNP XUS LPZ2A0500B 6.300 600 < 24 < 20 < 16 2 PNP XUS LPZ2A0600B 6.700 400 < 24 < 20 < 16 3 PNP XUS LPZ3A0400B 7.200 500 < 24 < 20 < 16 3 PNP XUS LPZ3A0500B 8.600 535340 300 < 24 < 20 < 16 4 PNP XUS LPZ4A0300B 8.200 300 < 24 < 20 < 16 5 PNP XUS LPZ5A0300B 9.500 XUS LPZ1AB XUS LPZ3AppppB 300 < 24 < 20 < 16 6 PNP XUS LPZ6A0300B 10.400 (1) Supplied with 2 sets of 2 brackets with fi xings and a user guide with certifi cate of conformity. (2) To order a receiver only, add the letter R to the end of the reference for the corresponding Example: reference XUS LPZ2A0600B becomes XUS LPZ2A0600BR for the receiver only. To order a transmitter only, add the letter T to the end of the reference for the corresponding Example: reference XUS LPZ2A0600B becomes XUS LPZ2A0600BT for the transmitter only. Other versions Combining type 4 safety light curtains with external module for muting function. See pages 30311/2 à 30311/9. 4

References (continued) Accessories for compact light curtains XUS LP Separate components Power supplies, 90 mirror adaptors, protective covers, anti-vibration kit, fixing bases See pages 30308-EN/2 to 30308-EN/9. Accessories Description Usage Length Reference Weight m kg Fixing kit (2 brackets) For light curtains XUS LP XUS LZ219 0.450 563528 XSZ PCTpp XSZ PCRpp Pre-wired female connectors Transmitter type 5 XSZ PCT05 0.350 10 XSZ PCT10 0.700 15 XSZ PCT15 1.020 30 XSZ PCT30 2.020 Receiver type 5 XSZ PCR05 0.350 10 XSZ PCR10 0.700 15 XSZ PCR15 1.020 30 XSZ PCR30 2.020 Sliding nuts for side fixing XUS LZ320 0.450 (4 nuts) User guide on CD-ROM All types of light curtain XUS LZ450 0.020 Arc suppressor (pair) All types of light curtain XUS LZ500 0.020 5

Dimensions Light curtains XUS LPZppp b b b 38,1 Ø 6,75x11,45 38,1 Ø 6,75x11,45 38,1 Ø 6,75x11,45 Ø6,8x16,7 Ø6,8x16,7 231,6 130,4 80 211,2 130,4 80 211,2 55 10,2 52 52,8 52 52,8 10,2 XUS b LPZ1Ap 231,6 220.7 LPZ2A0500p 731,6 500 720.7 LPZ2A0600p 831,6 600 820.7 LPZ3A0400p 1031,6 400 1020.7 LPZ3A0500p 1231,6 500 1220.7 LPZ4A0300p 1141,1 300 1120.7 LPZ5A0300p 1431,6 300 1411.2 LPZ6A0300p 1731,6 300 1711.2 pages 30313-EN/3 and 30313-6

Dimensions (continued) Light curtains XUS LPBppp 110 110 b 110 110 55 73,5 73,5 50,52 50,52 XUS b LPB2A500M 781.1 500 760.7 LPB2A600M 881.1 600 860.7 page 30313-EN/3 7

Connections Direct connection with XUS LPppp N L F1 Earth N L Power supply ABL 8RPS (4) Receiver XUS LPZ and transmitter-receiver XUS LPB Transmitter XUS LPZ (1) Earth 0 V 24 V 0 V 24 V MPCE/EDM AUX OSSD1 OSSD2 0 V 24 V MTS MTS Ret K1 K2 (3) NO To PLC (2) K1 K2 Test (1) For testing prior to installation, the user can select MPCE/EDM OFF (default factory setting). In this case, the MPCE/EDM line must be connected to the 0 V line of the system. (2) The auxiliary output connects to a PLC (optional). (3) If remote start is not used, connect the start line to the 0 V line. (4) The power supply must conform to EN/IEC 61496 and EN/IEC 60204-1 standards. Connection via a XPS AFL module Control panel L N L K3 K4 F3 F4 N L Power supply ABL 8RPS (3) F1 A1 C8 C7 S33 S34 S39 13 23 33 XPS AFL T Logic K1 K2 Control circuit K3 K4 0 V 24 V A2 S11 S12 S11 S22 14 24 34 To PLC (1) N K3 K4 Test 0 V 24 V MPCE/EDM AUX OSSD1 OSSD2 0 V 24 V MTS MTS Ret Transmitter XUS LPZ Receiver XUS LPZ and transmitter-receiver XUS LPB (2) (1) The auxiliary output connects to a PLC (optional). (2) The light curtain must be confi gured with MPCE/EDM OFF and with automatic start. (3) The power supply must conform to EN/IEC 61496 and EN/IEC 60204-1 standards. pages 30313-EN/3 and 30313-8

Connections XUS LPZ/LPBp Transmitter Pre-wired connector of transmitter (XUS LPZ) Transmitter status indicator Configuration indicator XUS LPZ Configuration indicator XUS LPB MTS return BK BU MTS 1 CODE 1 2 3 CODE 3 2 1 c 0 V BN N WH c + 24 V 1 Yellow LED Receiver Pre-wired connector of receiver (XUS LPZ) and pre-wired connector of transmitter-receiver (XUS LPB) Receiver status indicator Configuration indicator XUS LPZ and XUS LPB Auxiliary output MPCE/EDM BU PK WH Y OSSD2 YE N BN 1 2 3 4 1 Interlock or Alarm yellow LED 2 Machine stop red LED 3 Machine run green LED 4 2-digit display CODE 1 2 3 MODE 1 2 3 c + 24 V RD OSSD1 c 0 V Connection to terminal block Connection to M12 connector pages 30313-EN/3 to 30313-9