Performance of DVR & Distribution STATCOM in Power Systems

Similar documents
SIMULATION OF D-STATCOM IN POWER SYSTEM

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Performance of DVR under various Fault conditions in Electrical Distribution System

Power Quality Improvement in Distribution System Using D-STATCOM

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Mitigating Voltage Sag Using Dynamic Voltage Restorer

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

Power Quality enhancement of a distribution line with DSTATCOM

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

A Review on Improvement of Power Quality using D-STATCOM

Improvement of Power Quality Using a Hybrid Interline UPQC

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

DESIGN A D STATCOM FOR VOLTAGE HARMONIC SUPPRESSION IN DISTRIBUTION SYSTEM

DESIGN AND DEVELOPMENT OF SMES BASED DVR MODEL IN SIMULINK

Unit.2-Voltage Sag. D.Maharajan Ph.D Assistant Professor Department of Electrical and Electronics Engg., SRM University, Chennai-203

Enhancement of Power Quality in Distribution System Using D-Statcom

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

FUZZY CONTROLLED DSTATCOM FOR HARMONIC COMPENSATION

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

ICCCES Application of D-STATCOM for load compensation with non-stiff sources

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

Investigation of D-Statcom Operation in Electric Distribution System

Multi-Pulse Voltage Source Converter Statcom For Voltage Flicker Mitigation

Voltage Control and Power System Stability Enhancement using UPFC

FUZZY LOGIC CONTROL BASED DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT IN DISTRIBUTION SYSTEM

Power Quality and the Need for Compensation

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

A CONTROL TECHNIQUE FOR INSTANT MITIGATION OF VOLTAGE SAG/SWELL BY DYNAMIC VOLTAGE RESTORER

Power Quality Improvement using Hysteresis Voltage Control of DVR

Power Control Scheme of D-Statcom

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Voltage Sags in Distribution Systems with Induction Motor Loads Fed by Power Converters and Voltage Mitigation using DVR and D-STATCOM

Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Design of Interline Dynamic Voltage Restorer for Voltage Sag Compensation

Performance Improvement of Power System Using Static Synchronous Compensator (STATCOM) Priya Naikwad, Mayuri Kalmegh, Poonam Bhonge

SIMULATION RESULTS OF EIGHT BUS SYSTEM USING PUSH-PULL INVERTER BASED STATCOM

A NOVEL APPROACH ON INSTANTANEOUS POWER CONTROL OF D-STATCOM WITH CONSIDERATION OF POWER FACTOR CORRECTION

ISSN Vol.07,Issue.21, December-2015, Pages:

UNIFIED POWER QUALITY CONDITIONER IN DISTRIBUTION SYSTEM FOR ENHANCING POWER QUALITY

Voltage Correction Methods in Distribution System Using DVR

Voltage Sag Mitigation of DVR using Matlab Simulation

COMPARITIVE STUDY ON VOLTAGE SAG COMPENSATION UTILIZING PWM SWITCHED AUTOTRANSFORMER BY HVC

Analysis & Function of Unified Power Quality Conditioner for Power Quality Improvement of Distributed Network

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

IMPROVEMENT OF VOLTAGE SAG MITIGATION USING DYNAMIC VOLTAGE RESTORER (DVR)

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

IMPROVEMENT OF POWER QUALITY USING CUSTOM POWER DEVICES

D-STATCOM FOR VOLTAGE SAG, VOLTAGE SWELL MITIGATION USING MATLAB SIMULINK

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR)

Improvement of Dynamic Voltage Restorer (DVR) Using Proportional Integral (PI)Controller for Mitigation of Voltage Sag

factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is vo

CHAPTER 5 CONTROL SYSTEM DESIGN FOR UPFC

Power flow improvement using Static Synchronous Series Compensator (SSSC)

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Voltage Improvement Using SHUNT FACTs Devices: STATCOM

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

Volume I Issue VI 2012 September-2012 ISSN

Reduction of Voltage Imbalance in a Two Feeder Distribution System Using Iupqc

International Journal of Advance Engineering and Research Development CONTROL OF REDUCED-RATING DYNAMIC VOLTAGE RESTORER

Implementation of SPWM Technique in D-STATCOM for mitigating Power Quality Problem - Voltage Sag and Swell

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Improvement in Power Quality of Distribution System Using STATCOM

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

Design and Control of Interline Unified Power Quality Conditioner for Power Quality Disturbances

Mitigation of voltage sags/swells unbalanced in low voltage distribution systems

SIMULATION OF DSTATCOM FOR POWER FACTOR IMPROVEMENT

Interline Power Flow Controller: Review Paper

Compare Stability Management in Power System Using 48- Pulse Inverter, D-STATCOM and Space Vector Modulation Based STATCOM

Direct and Indirect Control Strategies of DSTATCOM Power Factor Controller

A New Unified Power Quality Conditioner for Grid Integration of PV System and Power Quality Improvement Feature Distribution System

Design and Development of DVR model Using Fuzzy Logic Controller for Voltage Sag Mitigation

Increasing Dynamic Stability of the Network Using Unified Power Flow Controller (UPFC)

Mitigation of Voltage Sag and Voltage Swell by Using D-STATCOM and PWM Switched Autotransformer

COMPENSATION OF VOLTAGE SAG USING LEVEL SHIFTED CARRIER PULSE WIDTH MODULATED ASYMMETRIC CASCADED MLI BASED DVR SYSTEM G.Boobalan 1 and N.

ISSN: ; e-issn

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

Implementation of UPQC for Voltage Sag Mitigation

Damping Power system Oscillation using Static Synchronous Series Compensator (SSSC)

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

Modeling of Statcom. P.M. Sarma and Dr. S.V. Jaya Ram Kumar. Department of Electrical & Electronics Engineering GRIET, Hyderabad, India

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Designing Of Distributed Power-Flow Controller

Transcription:

International Journal on Recent and Innovation Trends in Computing and Communication ISSN: 232-869 Volume: 3 Issue: 2 83 89 Performance of DVR & Distribution STATCOM in Power Systems Akil Ahemad Electrical Department Anjuman College Of Engg & Tech. Nagpur,India akil_35@rediffmail.com Prof. Pramod Gadge 2 Electrical Department Anjuman College of Engg.& Tech. Nagpur,India gadgepm@rediffmail.com Mohammad Safique 3 Electrical Department Anjuman College of Engg.& Tech. Nagpur,India safikm8@gmail.com Abstract-This paper investigates the effects of D-Statcom & Dynamic voltage Restorer (DVR) on voltage stability of a power system. This paper will discuss and demonstrate how both the devices succtssfully been applied to power system for effectively regulating system voltage. One of the major reasons for installing a & D-Statcom is to improve dynamic voltage control and thus increase system load ability. This paper describes the techniques of correcting the supply voltage sag, swell and interruption in a distributed system. At present, a wide range of very flexible controllers, which capitalize on newly available power electronics components, are emerging for custom power applications. Among these, both the devices are most effective, based on the VSC principle. A DVR injects a voltage in series with the system and D-Statcom inject the current with the system to correct the voltage sag, swell and interruption.results are presented to assess the performance of devices as a potential custom power solution. Improve dynamic voltage control and thus increase system load ability. This paper presents modelling and simulation of DVR & D-Statcom in MATLAB/Simulink Keywords-. Custom power, distribution static compensator (D-STATCOM), dynamic voltage restorer (DVR), PWM, voltage source converter. ***** I. INTRODUCTION The electrical power system is considered to be consisting three functional blocks like generation, transmission and distribution. For reliable power system, the generation unit must produce adequate power to meet customer s demand, transmission systems should transport bulk power over long distance without overloading or maintain system stability and distribution system must deliver electric power to each customer s premises from bulk power systems. Distribution system locates the end of power system and is connected to the customer directly, so the power quality mainly depends on distribution system.[4] One of the most common power quality problems today is voltage sag and swells. Voltage sag is a short time event during which a reduction in r.m.s voltage magnitude occurs similarly swell is event during which rise in r.m.s voltage magnitude. Initially for the improvement of power quality or reliability of the system FACTS devices like static synchronous compensator (STATCOM), static synchronous series compensator (SSSC), interline power flow controller (IPFC) and unified power flow controller(upfc) etc are introduce. These FACTS devices are designed for the transmission system. But now a day more attention is on the distribution system for the improvement of power quality, these devices are modified and known as custom power devices. The main custom power devices which used in distribution system for power quality improvement are distribution static synchronous compensator (D-STATCOM), dynamic voltage Restorer (DVR), active filter (AF), unified power quality conditioner (UPQC) etc. In this paper from the above custom power devices, D-STATCOM and DVR are used with PI controller for the power quality improvement in the distribution system. Here, different loads are considered with different fault condition and analyze the operation of D- STATCOM and DVR in distribution system.[] The DVR is a solid state dc to ac switching power converter that injects a set of three single phase ac output voltages in series with the distribution feeder and in synchronism with the voltages of the distribution system. By injecting voltages of controllable amplitude, phase angle and frequency (harmonic) into the distribution feeder in instantaneous real time via a series injection, the DVR can restore the quality of voltage at its load side terminals when the quality of the source side terminal voltage is significantly out of specification for sensitive load equipment. [3] The reactive power exchanged between the DVR and distribution system is internally generated by the DVR without any ac passive reactive components, i.e. reactors and capacitors. For large variations in the source voltage, the DVR supplies partial power to the load from a rechargeable energy source attached to the DVR dc terminal. The DVR, with its three single phase independent control and inverter design is able to restore line voltage to critical loads during sags caused by unsymmetrical as well as symmetrical three phase faults on adjacent feeders or disturbances that may originate many miles away on the higher voltage interconnected transmission system. Connection to the distribution network is via three single-phase series s there by allowing the DVR to be applied to all classes of distribution voltages. At the point of connection the DVR will, within the limits of its inverter, provide a highly regulated clean output voltage.[4] II DYNAMIC VOLTAGE RESTORER (DVR) Fig. block diagram of DVR IJRITCC February 25, Available @ http://www.ijritcc.org 83

International Journal on Recent and Innovation Trends in Computing and Communication ISSN: 232-869 Volume: 3 Issue: 2 8 2 III.DISTRIBTION STATIC COMPENSTOR (D-STATCOM) frequency in the range of few KHz. The IGBT Inverter is This presents the operating principles of D- controlled with PI controller in order to maintain p.u voltage STATCOM. The D-STATCOM is basically one of the custom at the load side. An advantage of proportional pulse integral power devices. It is nothing but a STATCOM but used at the controller is an actuating signal which is the difference Distribution level. The key component of the DSTATCOM is between the reference voltage and feedback load voltage. a power VSC that is based on high power electronics Output of the controller is in the form of an angle δ, which technologies. introduces additional phase-lag/lead in the three-phase voltage. The Distribution STATCOM is a versatile device for The output of error detector is the missing voltage. The providing reactive compensation in ac networks. The control controller output when compared at PWM signal generator of reactive power is achieved via the regulation of a controlled hence, the result in the desired firing sequence.[3] voltage source behind the leakage impedance of a, in much the same way as a conventional synchronous compensator. However, unlike the conventional synchronous compensator, which is essentially a synchronous generator where the field current is used to adjust the regulated voltage, the D-STATCOM uses an electronic voltage sourced converter (VSC), to achieve the same regulation task. The fast control of the VSC permits the STATCOM to have a rapid rate of response. [5] The sinusoidal signal V control phase modulated by means of the The DSTATCOM is the solid-state based power angle δ is, converter version of the SVC. Operating as a shunt connected V A =Sin (ωt + δ ) V B =sin (ωt + δ π/3) V C =sin SVC, its capacitive or inductive output currents can be (ωt + δ+2π/3) controlled independently from PWM technique. Because of the fast-switching characteristic of power converters, the D- STATCOM provides much faster response. D-STATCOM is a shunt connected, reactive compensation equipment, which is capable of generating and or absorbing reactive power whose output can be varied so as to maintain control of specific parameters of the electric power system. D-STATCOM employ solid state power switching devices, hence, it provides rapid controllability of the three phase voltages, both in magnitude and phase angle. [3] Fig. 3 phase modulation of the control angle δ. This modulated signal is compaired with triangular signal and generates the switching signals for the converter valves. The main parameters of the sinusoidal PWM scheme are the amplitude modulation index of signal, and the frequency modulation index of the triangular signal. The modulating angle is applied to the PWM generator in phase A. the angles for Phase B and phase C are shifted by 2º and 24º lagging respectively. [6] Fig.2 block diagram of D-statcom IV CONTROLLER A controller is required to control or to operate both D-Statcom and DVR during the fault condition only. Load voltage is sensed and passed through a sequence analyzer. The magnitude of the actual voltage is compared with reference voltage i.e Vref. Pulse width modulated(pwm) control system is applied for inverter switching so as to generate a three phase 5Hz sinusoidal voltage at the load terminals. Switching V PARAMETERS OF DVR TEST SYSTEM The test system consists of 3KV, 5Hz generation system (considered to be source). This source, feeding two transmission lines through a three winding connected in Y/ / 3/5/5 KV. Such transmission lines feed two distribution network through two connected in /Y, 5/KV. [3] Table. System parameters. Sr. System Quantities Standards No. Source 3KV,5Hz MVA 2 Three winding MVA,Y/ / 3/5/5 KV 3 Impedance of R=.5Ω/Km, L=.486 IJRITCC February 25, Available @ http://www.ijritcc.org 84

Voltage(KV) International Journal on Recent and Innovation Trends in Computing and Communication ISSN: 232-869 Volume: 3 Issue: 2 8 2 transmission line H/Km 4 Impedance of R2=mΩ/Km, L2=5mH/KM transmission line2 5 Two winding MVA,5Hz, /Y 5/ KV 6 Injection MVA, 5Hz, /Y /KV 7 Load on bus P=6.5MW(resisitive load) 8 Load on bus2 P=3.4922KW 9 Inverter parameters Q=2MVAR(highly inductive) IGBT based, 3 arms, 6 pulse, carrier Frequency=8Hz PI controller Kp=.5, Ki=5, Sample time=5µs Filter unit L= 7mH C=5 µf 2 Rating of DVR 5MVA Fig.5 Simulation of test system without fault and without DVR The following result shows the system when considering no fault and no connection of DVR..2 VI SINGLE LINE DIAGRAM OF THE DVR TEST SYSTEM.8.6.4.2..2.3.4.5.6.7.8.9 fig. 4 single line diagram of DVR In the above test system we have a generating unit of 3KV, 5Hz which is considered as source of MVA. The test system is constructed with concerning the DVR actuation. The output from the source is fed to the primary of tertiary winding. Now, further two parallel feeders of KV each are drawn with the help of two winding. In one of the feeder (L2) DVR is connected in series and on other line fault is applied to create sag. VII SIMULINK MODEL OF TEST SYSTEM AND RESULTS A Simulation of test system without fault and without DVR 2 x 4.5.5 -.5 -..2.3.4.5.6.7.8.9 line to line voltage (KV) at load side B Simulink model of test system with fault but without DVR In this simulink model we have system which fed the two buses or feeders through two winding as shown. On the upper bus we are applying the 3phase Line to ground fault(3lg), here we are not considering the presence IJRITCC February 25, Available @ http://www.ijritcc.org -.5 85

Voltage (KV) International Journal on Recent and Innovation Trends in Computing and Communication ISSN: 232-869 Volume: 3 Issue: 2 8 2 of DVR and have to observe the effect on voltages on the lower bus(second bus or second feeder). Fig. 6 Simulink model with fault without DVR. C Simulation Result of test system with fault and without DVR From the following results it is observed that during the fault time i.e.4-.6 sec, the voltage sag to some finite value. Since the fault is on upper bus, hence sag may be 7-8%. The sag on the lower bus at the load side is nearly - 5%, and measured the line to line voltage value during fault time is.kv..2 E Fig.7simulation test system with DVR Simulation Results with fault and with DVR From the following results it is clear that the DVR compensate the voltage sag during the fault time.4-.6 sec. the compensated results of sag with respective rms value of voltage, instantaneous value, line to line voltage injected by the DVR which is nearly.5kv..5.5 -.5 -.5 2 x 4 -.8.6.4.2..2.3.4.5.6.7.8.9 (sec)..2.3.4.5.6.7.8.9 (sec) line to line voltage (KV) at load side D Simulink model of test system with fault and with DVR In this simulink model we have system which fed the two buses or feeders through two winding as shown. On the upper bus we are applying the three phase Line to ground fault (3LG). And on the lower bus we have connected the DVR because in this bus sag is low and custom device can compensate easily. The system is shown in following fig..5.5 -.5 -.5.2.8.6.4.2 2 x 4 -..2.3.4.5.6.7.8.9..2.3.4.5.6.7.8.9 line to line voltage (KV) at load side VIII PARAMETERS OF D-STATCOM TEST SYSTEM The test system consists of 23KV, 5Hz transmission line (considered to be source). This source, feeding two distribution network through a three winding connected in Y/ / 23// KV. [3] Table system parameters Sr. System Quantities Standards No. Source 23KV, 5Hz MVA IJRITCC February 25, Available @ http://www.ijritcc.org 86

International Journal on Recent and Innovation Trends in Computing and Communication ISSN: 232-869 Volume: 3 Issue: 2 8 2 2 Three winding MVA,Y/Y/Y 23// KV 3 Load on bus P=.776MW, Q=65.26MVAR(highly inductive) 4 Load on bus2 P=385.24KW Q=2MVAR(highly inductive) 5 Injection MVA, 5Hz, /Y /KV 6 Inverter parameters IGBT based, 3 arms, 6 pulse, carrier Frequency=8Hz 7 Rating of D- STATCOM 5 MVAR IX SINGLE LINE DIAGRAM OF THE DVR TEST SYSTEM In the above test system we have a transmission line of 23KV, 5Hz which is considered as source of MVA. The test system is constructed with concerning the D-Statcom actuation. The source is fed to the primary of tertiary winding. Now, further two parallel feeders of KV each are drawn from secondary winding the. In one of the feeder D-STATCOM is connected in shunt and on other line two parallels loads are connected. The fault is applied at load side to create sag. fig.9 simulink model without fault and without D- STATCOM. A Simulation Results without fault and without D-STATCOM The following results shows the system when considering no fault and no connection of D-STATCOM rms value of Voltage in p.u, instantaneous voltages, line to line voltage. The line to line voltage nearlykv is measured..9.8.7.6.5.4.3.2...2.3.4.5.6.7.8.9.5.5 -.5 -.5 2 x 4 -..2.3.4.5.6.7.8.9 line to line voltage (KV) at load side. Fig.8 single line diagram of D-Statcom B Simulation of test system with fault but without D-STATCOM X Simulation of test system without fault and without D- STATCOM. This simulink model presents the test system without any fault and no connecting custom device like D-Statcom. Fig. Simulation test system without D-STATCOM C Simulation Results with fault but without D-STATCOM From the following results it is observed that during the fault time i.e.4-.6 sec, the voltage sag to some finite 87 IJRITCC February 25, Available @ http://www.ijritcc.org

Voltage(KV) International Journal on Recent and Innovation Trends in Computing and Communication ISSN: 232-869 Volume: 3 Issue: 2 8 2 value.the sag during the fault at the load side is nearly - 5%, and measured the line to line voltage value during fault time is.25kv..8.6.8.6.4.2 D.5.5 -.5 -.5 2 x 4 -.4.2..2.3.4.5.6.7.8.9..2.3.4.5.6.7.8.9 line to line voltage (KV) at load side. Simulation of test system with D-STATCOM In this simulink model we have system which fed the load through secondary winding of tertiary as shown. Out of two parallel loads, sag is created by providing the switching on one of load. The D-STATCOM is connected to one of the secondary winding of tertiary.the system is shown in following..5.5 -.5 -.5 2 x 4 -..2.3.4.5.6.7.8.9..2.3.4.5.6.7.8.9 line to line voltage (KV) at load side with fault but without D-STATCOM XI CONCLUSION The paper presented the study and simulation model of custom power equipment, namely D-STATCOM and DVR, and applied them for power quality problem such as voltage sag. The highly develop graphic facilities available in MATLAB is used to conduct all the aspect of model implementation and to carry out extensive simulation studies. A controller which is based on closed loop technique is used which generate error signals and this signals are used to trigger the switches of inverter using pulse width modulation (PWM) scheme in the D-STATCOM and DVR, this PWM control scheme only requires voltage measurements. The simulations are carried out for both sag on KV feeder using both D- Statcom and DVR as custom power devices and it has been found that DVR provide excellent voltage regulation capabilities. It is also observed that the DVR capacity for power compensation and voltage regulation depends mainly on two factors that is, the rating of the dc storage device and the coupling. [6] REFERENCES Fig. Simulation test system with D-STATCOM E Simulation Results with fault and with D-STATCOM From the following results it is clear that the D- STATCOM compensate the voltage sag during the fault time.4-.6 sec. the compensated results of sag with respective rms value of voltage, line to line voltage. [] N.G.Hingorani, Flexible AC Transmission, IEEE Spectrum, vol. 3, pp.4-44,993. [2] N.G.Hingorani, Introducing Custom Power, IEEE Spectrum, vol. 32 pp.4-48,995. [3] Anaya-Lara O, Acha E., Modeling and analysis of custom power system by PSCAD/EMTDC, IEEE Transactions on Power Delivery, Vol.7, and Issue:, Jan. 22. Pp.26672. [4] M.J.H.Bollen, Voltage sags in three-phase system Power Engineering Review, IEEE, Vol.2 Issue:9, Sept.2.pp.8-. [5] Haque. M.H, Compensation of distribution system voltage sag by DVR and D-STATCOM. Power Tech. proceeding. 2IEEE Porto, vol., Issue: Sept. 2 pp.-3 [6] S.V Ravi Kumar SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS ARPN Journal of Engineering and Applied Sciences.VOL. 2, NO. 3, JUNE 27 IJRITCC February 25, Available @ http://www.ijritcc.org 88

International Journal on Recent and Innovation Trends in Computing and Communication ISSN: 232-869 Volume: 3 Issue: 2 8 2 [7] Arindam Ghosh, Copensation of Distribution System Voltage Using DVR. IEEE Transaction on power delivery, vol.7, No.4, Oct. 22. pp.3-36 [8] H.P Tiwari and Sunil Kumar Gupta Dynamic Voltage Restorer against Voltage Sag International of Innovation, Management and Technology vol.3, pp. 23237,2. [9] C.S Chang, Y.S Ho, The Influence of Motor Load on the Voltage Restoration Capability of Dynamic Voltage Restorer. Power System Technology, Proceedings, Power Con, International Conference, vol.2,pp. 637-642,2. [] M.H. Rashid, Power Electronics 2nd edition, Elsevier, Inc, Publication, Californial, U.S.A 27. [] Rakosh Das Begamudre, Extra High Voltage AC Transmission Engineering, 2nd Edition, New Age International Limited, New Delhi 99. [2] Majid Moradlou and Hamid R. Karshenas, Design Strategy for Optimum Rating Selection of Interline DVR IEEE, VOL. 26, NO., Jan, 2 IJRITCC February 25, Available @ http://www.ijritcc.org 89