Company Directive POLICY DOCUMENT: SD4/7. Relating to 11kV and 6.6kV System Design

Similar documents
Company Directive STANDARD TECHNIQUE: SD1E/2. Technical Requirements for Customer Export Limiting Schemes

Company Directive STANDARD TECHNIQUE: TP6F/1. Power Measurement Conventions

STANDARD TECHNIQUE: SD4A/1

Company Directive STANDARD TECHNIQUE: SD5R/2. Earth Fault Loop Impedances and Phase to Neutral Loop Impedances at LV Installations

QUESTIONNAIRE for Wind Farm Power Stations only

Connection of Embedded Generating Plant up to 5MW

Company Directive STANDARD TECHNIQUE: SD5F. Relating to connecting multiple small low voltage connections with limited network analysis

Table of Contents. Introduction... 1

G81 PART 1 FRAMEWORK APPENDIX

Company Directive STANDARD TECHNIQUE: SD7F/2. Determination of Short Circuit Duty for Switchgear on the WPD Distribution System

SYNCHRONISING AND VOLTAGE SELECTION

Network Monitoring and Visibility Summary

TS RES - OUTSTANDING ISSUES

POWER CORPORATION. Power Quality. Specifications and Guidelines for Customers. Phone: Fax:

each time the Frequency is above 51Hz. Continuous operation is required

Energy Networks Association

Power Quality Summary

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Embedded Generation Connection Application Form

EDS FAULT LEVELS

INTERIM ARRANGEMENTS FOR GRID TIED DISTRIBUTED ENERGY RESOURCES. Technical Requirements for Grid-Tied DERs

J Project Methods. V (%) Network with high generation and low load. Network with low generation and high load

Embedded Generation Connection Application Form

Low Frequency Demand Disconnection Summary

Protection of Electrical Networks. Christophe Prévé

ELECTRICITY ASSOCIATION SERVICES LIMITED 2001

BED INTERCONNECTION TECHNICAL REQUIREMENTS

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

Impact of Distributed Generation on Voltage Regulation by ULTC Transformer using Various Existing Methods

Intermittent Renewable Resources (Wind and PV) Distribution Connection Code (DCC) At Medium Voltage (MV)

MidAmerican Energy Company Reliability Planning Criteria for 100 kv and Above

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

EUROPEAN CONNECTION CONDITIONS (ECC) CONTENTS. (This contents page does not form part of the Grid Code)

Wind Power Facility Technical Requirements CHANGE HISTORY

VOLTAGE MANAGEMENT BY THE APPORTIONMENT OF TOTAL VOLTAGE DROP IN THE PLANNING AND OPERATION OF COMBINED MEDIUM AND LOW VOLTAGE DISTRIBUTION SYSTEMS

IEEE sion/1547revision_index.html

T-68 Protecting Your Equipment through Power Quality Solutions

Digital Fault Recorder Deployment at HVDC Converter Stations

Revision 24 of Issue 3 of the Grid Code has been approved by the Authority for implementation on 19 th November 2007.

Technical Requirements for Connecting Small Scale PV (sspv) Systems to Low Voltage Distribution Networks

Tasmanian Networks Pty Ltd Guideline. Technical Requirements for the Connection of Embedded Generation

VI 3 - i TABLE OF CONTENTS

Engineering Recommendation M30 Issue Standard Electricity Network Operator Electricity Smart Meter Configurations

SYSTEM MONITORING FAULT RECORDING

Distribution transformers Part 2 Ground mounted transformers not closecoupled

Revision Control. 0 18/07/2012 Initial Document Creation. STAKEHOLDERS The following positions shall be consulted if an update or review is required:

Company Directive STANDARD TECHNIQUE: TP14C. Distribution Business Provided Metering Facilities

BC HYDRO REAL TIME OPERATIONS OPERATING ORDER 7T-30A. NORTH COAST INTERCONNECTION: SKEENA BOB QUINN SUBSYSTEM Supersedes OO 7T-30A dated 07 July 2014

Generation and Load Interconnection Standard

Key DRAFT EUROPEAN CONNECTION CONDITIONS LEGAL TEXT DATED 13/12/17

WFPS1 WIND FARM POWER STATION GRID CODE PROVISIONS

POWER QUALITY SPECIFICATIONS AND GUIDELINES FOR CUSTOMERS ENGINEERING STANDARDS CITY OF LETHBRIDGE ELECTRIC

Electrical Description

Impact Assessment Generator Form

LIMITS FOR TEMPORARY OVERVOLTAGES IN ENGLAND AND WALES NETWORK

ESB National Grid Transmission Planning Criteria

Southern Company Power Quality Policy

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

INCREASING NETWORK CAPACITY BY OPTIMISING VOLTAGE REGULATION ON MEDIUM AND LOW VOLTAGE FEEDERS

IEEE 1547: Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces

E N G I N E E R I N G M A N U A L

STANDARDS/MANUALS/ GUIDELINES FOR SMALL HYDRO DEVELOPMENT

Draft Kenya Standard for Balloting Not to be Cited as Kenya Standard

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

Distributed generation on 11kV voltage constrained feeders

ECP HV INSULATION TESTING

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Renewable Interconnection Standard & Experimental Tests. Yahia Baghzouz UNLV Las Vegas, NV, USA

Customer Standard. Standard for Embedded Generation (5MW and above)

Loss of Mains Protection

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

DUKE ENERGY CAROLINAS TRANSMISSION SYSTEM PLANNING GUIDELINES. Transmission Planning

Company Directive STANDARD TECHNIQUE: TP21D/2. 11kV, 6.6kV and LV Earthing

MODELLING AND ANALYSIS OF THE ENHANCED TAPP SCHEME FOR DISTRIBUTION NETWORKS

SUBJECT HEADING: Switching Programmes ISSUE: 18

Embedded Generation Connection Application Form

Earthing Guidance Notes

SPTS 1 - Ratings and General Requirements for Plant, Equipment and Apparatus for The ScottishPower System and Connection Points to it.

Fault Ride Through Technical Assessment Report Template

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

Distribution Code. Approved by CER. Version: 5.0 Date: April Distribution System Operator ESB Networks Limited

Modeling and Validation of an Unbalanced LV Network Using Smart Meter and SCADA Inputs

Data Sheet. RISH Master Record %THD

The Advantages and Application of Three Winding Transformers

Contents. All Rights Reserved

PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION

Network Equilibrium Balancing Act Conference Thursday 8th September 2016

EI HIGH VOLTAGE INSULATION TESTING POLICY

NIC Project Medium Voltage Direct Current Link Technical Specification

The development of the SA grid code on Power Quality emission. Dr. Gerhard Botha 2017/08/08

FAQ ON EARTHING STANDARDS 16/08/2018

TTC Study for: the PEGS-Ambrosia Lake 230 kv Line and the PEGS-Bluewater 115 kv Line

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction. See the Implementation Plan for PRC

Utility Licence Annual Technical Report

GRID CONNECTION CODE FOR RENEWABLE POWER PLANTS

Company Directive ENGINEERING SPECIFICATION EE SPEC: 5/5. Relating to 11kV Distribution Transformers

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

TECHNICAL SPECIFICATIONS AND OPERATING PROTOCOLS AND PROCEDURES FOR SMALL GENERATION INTERCONNECTIONS

KENYA ELECTRICITY GENERATING COMPANY LTD

Transcription:

Company Directive POLICY DOCUMENT: SD4/7 Relating to 11kV and 6.6kV System Design Policy Summary This document describes the standard requirements for the design of the 11kV and 6.6kV systems. Reference is also made to the Distribution Code, ENA Engineering Recommendations P2 P28, P29, G5, G59, G74 and to Western Power Distribution Engineering Directives POL:SD1 and POL:TP4 (as amended). NOTE: The current version of this document is stored in the WPD Corporate Information Database. Any other copy in electronic or printed format may be out of date. Copyright 2017 Western Power Distribution POL:SD4/7 September 2017-1 of 12 -

IMPLEMENTATION PLAN Introduction POL: SD4 specifies the high level requirements for 11kV and 6.6kV System Design. Main Changes A new section has been added for networks that include active load management. Impact of Changes New design requirements have been introduced for networks that include active load (generation and/or demand) management. Planners shall ensure these requirements are satisfied. Implementation Requirements Managers shall ensure that staff involved in the design of the 11kV and/or 6.6kV network, or with the appraisal / approval of 11kV and/or 6.6kV capital sanctions, are aware of the requirements of this document. Implementation Timescale Document implemented on issue. POL:SD4/7 September 2017-2 of 12 -

REVISION HISTORY Document Revision and Review Table Date Comments Name September 2017 Section 2.1.1 relating to the requirements for networks that include active load management has been added. Andy Hood February 2017 June 2015 The minimum voltage limits listed in Table 1 and Table 2 have been reduced by approximately 0.5% Point 3.1.2 on page 5 amended - voltage drop values corrected Andy Hood Andy Hood January 2015 Table 2 has been expanded to include +8.4%, +4.2%, -4.2% and -8.4% tap positions that are provided on some dual ratio 11000/6600/433V transformers when set to their 6600V/433V ratio. An additional footnote has been added to Table 3 Andy Hood November 2014 Links to ENA Engineering Recommendations, the Distribution Code and Grid Code have been updated. Document version numbers have been removed and replaced by the term as amended. Section 3.1 regarding Voltage Limits has been rewritten. Table B1 which stated the % voltage regulation across different parts of the network has been replaced by Table 1 and Table 2 which now define specific voltage limits for 11kV and 6.6kV networks. 3.1.4 specifies requirements for back-feed conditions. Table 3 (formerly Table B2) has been expanded to take account of leading power factors. Andy Hood POL:SD4/7 September 2017-3 of 12 -

1.0 INTRODUCTION This document describes the standard requirements for the design of the 11kV and 6.6kV systems and details the security, supply quality, safety, asset utilisation and capital investment requirements. Where any difficulty is encountered with the application of this policy, the author should be notified, who will consider if a variation to this policy is appropriate. Where the term load is used within the document this refers to the load associated with both generation and demand. The practical details of the application of this policy are contained in a range of ST documents with a reference beginning ST:SD4. 2.0 POLICY The design of the 11kV and 6.6kV systems shall satisfy the requirements of the Distribution Code of Licensed of Distribution Network Operators of Great Britain, as amended. 2.1 System Security 11kV and 6.6kV systems shall be designed to: provide a standard of security not less than that set out in ENA EREC P2, as amended. have less than 5000 customers fed from single 66kV or single 33kV transformers, unless there is an automatic or remotely operable backfeed arrangement. 2.1.1 Where the load is actively managed, e.g. using Active Network Management (ANM), soft intertrip, conventional intertripping or other equivalent load constraint / control schemes, the network shall satisfy the following criteria: (a) When the effect of active load management schemes are disregarded (i.e. the network is modelled without such schemes): The maximum load on any overhead circuit shall not exceed 110% of its rating The maximum load on any item of plant or equipment, excluding overhead lines, shall not exceed 125% of its rating The voltage on the 11kV and 6.6kV network shall remain within the following limits: Nominal Voltage +/- 10% POL:SD4/7 September 2017-4 of 12 -

(b) Active load management systems shall, as far as possible, include watchdog and communications failure facilities that curtail the load in the event of a scheme failure. Such systems shall be designed to curtail the load before the thermal ratings of plant and equipment are exceeded. (c) In the event of the failure of an active load management system or its associated communications / control systems, no more than 50MW of load shall be curtailed per minute and no more than 200MW of load shall be curtailed in total, across all voltage levels. 2.1.2 Improvements to system reliability will be considered in accordance with ST:AM5C and POL:FI 06/04/01. 2.2 Supply quality 11kV and 6.6kV systems will be designed: to ensure that the voltage at customers supply terminals comply with the limits defined in the Electricity Safety, Quality and Continuity Regulations 2002. Further guidance on maintaining voltage limits is provided in section 3.0. to ensure that new connections comply with the voltage unbalance limits contained in ENA EREC P29, as amended. to ensure that new connections comply with the voltage fluctuation requirements of ENA EREC P28, as amended. to ensure that new connections comply with the limits for harmonics in the UK contained in ENA EREC G5, as amended. 2.3 Safety 11kV and 6.6kV systems will be designed: to be protected in accordance with POL:TP4 to ensure that generator connectors comply with ENA EREC G59, as amended. to take account of the fault level calculation methodology as detailed in ENA EREC G74, as amended. to operate within equipment design ratings including any appropriate cyclic or short term rating as defined in the appropriate Engineering Instructions and Engineering Directives. POL:SD4/7 September 2017-5 of 12 -

2.4 Asset Utilisation and Capital Investment 11kV and 6.6kV systems will be designed: using equipment approved by the Policy Manager. using equipment of standard capacities. to improve asset utilisation unless the system security, supply quality or safety criteria of this policy will be impaired. for the lowest lifetime cost in accordance with POL:AM5 and POL:FI 06/04/01. 3.0 BACKGROUND 3.1 Voltage Limits 3.1.1 WPD s distribution transformers generally have manually adjustable (rather than automatically adjustable) tap positions. This means that the voltage on the LV network is normally controlled by the automatic tap-changers and automatic voltage regulators on the 11kV and 6.6kV networks. 3.1.2 It is assumed that the maximum voltage regulation across the LV network and distribution transformer is +1.5% and - 8% (of nominal voltage). This equates to a maximum voltage rise of +3.45V on the LV network + transformer and maximum voltage drop of 18.4V on the LV network + transformer. 3.1.3 In order to maintain statutory voltage at LV, 11kV and 6.6kV connections the maximum and minimum voltage limits defined in Table 1 and Table 2 shall be satisfied. These tables specify the voltage limits at the HV terminals of WPD owned distribution transformers, and at HV connected customers. The limits at the HV terminals of a distribution transformer depend on the transformer tap position. 3.1.4 Lower voltage limits for back feed conditions are also listed in Table 1 and Table 2 (within brackets). Despite this, all reasonable steps shall be taken to satisfy the normal voltage limits when outages are taken, for example by: Only taking planned outages during periods of low load. Splitting the back fed network between different circuits. Feeding some substations from mobile generators. Where it is not possible to satisfy the normal limits during back feed conditions the lower limits may be used, however the duration shall be kept to a minimum. POL:SD4/7 September 2017-6 of 12 -

These steps will minimise the risk of a network running outside of statutory limits whilst still allowing the network to be back fed under the most extreme conditions. 3.1.5 In addition, in order to ensure equipment ratings are not exceeded, the RMS voltage on any part of WPD s 11kV network shall not exceed 12kV and on any part of WPD s 6.6kV network shall not exceed 7.2kV. 3.1.6 When assessing the maximum voltage rise and maximum voltage drop on the network the bandwidth of the tap change control scheme shall be taken into account. This bandwidth is specified by Primary System Design and depends on the size of the tap steps, the make and type of tap-change control relay (e.g. electromechanical or electronic / solid state) and, to some extent, on the characteristics of the load. The bandwidth is set between +/- 1.0% and +/- 2.0% and a value of +/-1.25% is typical. Consideration shall also be given to line drop (or load drop) compensation settings, where applied. 3.1.7 Distribution Transformer Voltage Regulation The value of voltage drop / rise across 11kV/LV or 6.6kV/LV distribution transformer depends on the magnitude of current flowing through the transformer and the power factor. Table 3 lists the voltage drop across different types of distribution transformers operating at their name plate rating (based on a phase to neutral voltage of 230V) for a number of different power factors. POL:SD4/7 September 2017-7 of 12 -

Table 1 Voltage Limits on the 11kV Network [3] Distribution Transformer Tap (%) Voltage Limits for the HV terminals of WPD 11kV Distribution Transformers Voltage Limits for HV Metered Connections Max. [2] Min. Max. [2] Min. +7.5% [5] 11.66kV 10.93kV (10.50kV) [1] +5% 11.59kV 10.68kV (10.25kV) [1] +2.5% 11.31kV 0 11.04kV 10.42kV (10.01kV) [1] 10.17kV (9.77kV) [1] 11.66kV 10.34kV (9.90kV) [1] -2.5% 10.76kV 9.92kV (9.52kV) [1] -5% 10.49kV 9.66kV (9.28kV) [1] Note: [1] The minimum values in brackets only apply under abnormal feeding arrangements. Further guidance on the application of these values is given in 3.1.4. [2] The maximum voltage values apply under both normal and abnormal feeding arrangements. [3] Under no circumstances shall the RMS voltage on the 11kV network exceed 12kV. [4] The transformer tap numbers apply to transformers with 5 tap positions. Some small transformers only have 3 tap positions (+5%, 0 and -5%). [5] At the time of issue of this document distribution transformers are specified with a tap range of +5% to -5%. This tap range is expected to change to +7.5% to -2.5% in the future. POL:SD4/7 September 2017-8 of 12 -

Table 2 Voltage Limits on the 6.6kV Network [3] Distribution Transformer Tap (%) Voltage Limits for the HV terminals of WPD 6.6kV Distribution Transformers Voltage Limits for HV Metered Connections Max. [2] Min. Max. [2] Min. +8.4% [5] 7.00kV 6.61kV (6.35kV) [1] +5% [5] 6.95kV 6.41kV (6.15kV) [1] +4.2% [5] 6.90kV 6.36kV (6.10kV) [1] +2.5% [5] 6.79kV 6.25kV (6.01kV) [1] 0 6.62kV 6.10kV (5.86kV) [1] 7.00kV 6.20kV (5.94kV) [1] -2.5% [5] 6.46kV 5.95kV (5.71kV) [1] -4.2% [5] 6.35kV 5.85kV (5.62kV) [1] -5% [5] 6.29kV 5.80kV (5.57kV) [1] -8.4% [5] 6.07kV 5.59kV (5.37kV) [1] Note: [1] The minimum values in brackets only apply under abnormal feeding arrangements. Further guidance on the application of these values is given in 3.1.4. [2] The maximum voltage values apply under both normal and abnormal feeding arrangements. [3] Under no circumstances shall the RMS voltage on the 6.6kV network exceed 7.2kV. [4] The transformer tap numbers apply to transformers with 5 tap positions. Some small transformers only have 3 tap positions (e.g. +5%, 0 and -5%). [5] 11000/6600/433V dual ratio transformers either have 2.5% tap steps or 4.2% tap steps when connected to their 6600/433 ratio. Please refer to the transformer name-plate for the available tap steps. POL:SD4/7 September 2017-9 of 12 -

Table 3: Voltage Drop / Rise across Distribution Transformers (% of 230V) at Rated Current T/F Type/Rating R(Ω) X(Ω) Percentage Voltage Change (230V base) [1] Current Lagging Power Factor Leading Power factor [2] (A) 1.00 0.99 0.98 0.95 0.90 0.85 0.80 0.99 0.98 0.95 0.9 Conventional Ground Mounted Transformers 1500 kva 3Ø 0.0013 0.0067 2000.00 1.13% 1.94% 2.27% 2.89% 3.56% 4.03% 4.40% 0.30% -0.05% -0.75% -1.52% 1000 kva 3Ø 0.0022 0.0086 1333.33 1.28% 1.97% 2.24% 2.77% 3.32% 3.71% 4.01% 0.56% 0.26% -0.35% -1.03% 800 kva 3Ø 0.0029 0.0107 1066.67 1.34% 2.03% 2.31% 2.83% 3.37% 3.76% 4.05% 0.63% 0.33% -0.27% -0.95% 750 kva 3Ø 0.0031 0.0115 1000.00 1.35% 2.04% 2.32% 2.84% 3.39% 3.39% 4.08% 0.63% 0.33% -0.28% -0.97% 500 kva 3Ø 0.0051 0.0171 666.67 1.48% 2.16% 2.44% 2.95% 3.49% 3.49% 4.16% 0.76% 0.46% -0.14% -0.83% 315 kva 3Ø 0.0090 0.0268 420.00 1.64% 2.32% 2.58% 3.09% 3.61% 3.61% 4.25% 0.94% 0.64% 0.03% -0.65% 300 kva 3Ø 0.0095 0.0277 400.00 1.65% 2.32% 2.58% 3.07% 3.59% 3.59% 4.21% 0.96% 0.66% 0.07% -0.61% 200 kva 3Ø 0.0158 0.0406 266.67 1.83% 2.48% 2.73% 3.21% 3.70% 3.70% 4.29% 1.15% 0.86% 0.27% -0.40% Pole Mounted Transformers 315 kva 3Ø 0.0090 0.0268 420.00 1.64% 2.32% 2.58% 3.09% 3.61% 3.97% 4.25% 0.94% 0.64% 0.03% -0.65% 200 kva 3Ø 0.0158 0.0406 266.67 1.83% 2.48% 2.73% 3.21% 3.70% 4.04% 4.29% 1.15% 0.86% 0.27% -0.40% 100 kva 3Ø 0.0371 0.0810 133.33 2.15% 2.79% 3.04% 3.51% 3.98% 4.30% 4.54% 1.47% 1.17% 0.58% -0.11% 50 kva 3Ø 0.0876 0.1440 66.67 2.54% 3.10% 3.32% 3.72% 4.10% 4.36% 4.54% 1.92% 1.66% 1.11% 0.47% 25 kva 3Ø 0.2080 0.2660 33.33 3.01% 3.53% 3.72% 4.07% 4.39% 4.59% 4.72% 2.44% 2.19% 1.66% 1.03% 100 kva Split Phase 0.0223 0.0510 200.00 1.93% 2.54% 2.78% 3.22% 3.67% 3.98% 4.21% 1.29% 1.10% 0.45% -0.19% 50 kva Split Phase 0.0532 0.0992 100.00 2.31% 2.90% 3.13% 3.54% 3.96% 4.24% 4.44% 1.68% 1.41% 0.85% 0.20% 25 kva Split Phase 0.1124 0.1888 50.00 2.44% 3.00% 3.21% 3.60% 3.99% 4.24% 4.42% 1.84% 1.58% 1.04% 0.41% 100 kva 1Ø 0.0111 0.0255 400.00 1.93% 2.54% 2.78% 3.22% 3.67% 3.98% 4.21% 1.29% 1.01% 0.45% -0.19% 50 kva 1Ø 0.0266 0.0496 200.00 2.31% 2.90% 3.13% 3.54% 3.96% 4.24% 4.44% 1.68% 1.41% 0.85% 0.20% 25 kva 1Ø 0.0612 0.0944 100.00 2.66% 3.21% 3.42% 3.81% 4.18% 5.42% 4.59% 2.06% 1.79% 1.25% 0.61% 16 kva 1Ø 0.1390 0.1390 64.00 3.87% 4.37% 4.56% 4.88% 5.17% 5.33% 5.41% 3.28% 3.02% 2.47% 1.80% 15 kva 1Ø 0.1460 0.1460 60.00 3.81% 4.31% 4.49% 4.81% 5.09% 5.24% 5.33% 3.23% 2.97% 2.43% 1.77% 10 kva 1Ø 0.2060 0.2060 40.00 3.58% 4.05% 4.22% 4.52% 4.79% 4.93% 5.02% 3.04% 2.80% 2.28% 1.66% 5 kva 1Ø 0.3620 0.3620 20.00 3.15% 3.56% 3.71% 3.97% 4.21% 4.33% 4.41% 2.67% 2.46% 2.01% 1.46% [1] Where power flow is in the conventional direction, i.e. from the HV side to the LV side of the transformer, positive figures indicate voltage drop values and negative figures (i.e. the shaded areas) indicate voltage rise values. This convention is reversed where power flow is in the opposite direction (e.g. due to generation). [2] A demand customer with a leading power factor imports real power and exports reactive power. A generator operating with a leading power factor exports real power (kw) and imports reactive power (kvar) POL:SD4/7 September 2017-10 of 12 -

Table 3 (continued): Voltage Drop across Distribution Transformers (% of 230V) at Rated Current T/F Type/Rating R(Ω) X(Ω) Padmount Transformers Current (A) 1.00 Percentage Voltage Change (230V base) [1] Lagging Power Factor Leading Power Factor [2] 0.99 0.98 0.95 0.90 0.85 0.80 0.99 0.98 0.95 0.9 200 kva 3Ø (Coopers) 0.0074 0.0258 266.67 0.86% 1.27% 1.44% 1.75% 2.08% 2.31% 2.48% 0.43% 0.25% -0.12% -0.53% 100 kva 3Ø (Coopers) 0.0271 0.0401 133.33 1.57% 1.88% 2.00% 2.22% 2.43% 2.56% 2.65% 1.23% 1.08% 0.77% 0.40% 50 kva 1Ø (Coopers) 0.0182 0.0206 200.00 1.58% 1.82% 1.91% 2.06% 2.21% 2.29% 2.34% 1.31% 1.19% 0.94% 0.64% 315 kva 3Ø (ABB) 0.0090 0.0268 420.00 1.64% 2.32% 2.58% 3.09% 3.61% 3.97% 4.25% 0.94% 0.64% 0.03% -0.65% 200 kva 3Ø (ABB) 0.0158 0.0406 266.67 1.83% 2.48% 2.73% 3.21% 3.70% 4.04% 4.29% 1.15% 0.86% 0.27% -0.40% 100 kva 3Ø (ABB) 0.0371 0.0810 133.33 2.15% 2.79% 3.04% 3.51% 3.98% 4.30% 4.54% 1.47% 1.17% 0.58% -0.11% 50kVA 3Ø (ABB) 0.0876 0.1440 66.67 2.54% 3.10% 3.32% 3.72% 4.10% 4.36% 4.54% 1.92% 1.66% 1.11% 0.47% 50 kva 1Ø (ABB) 0.0266 0.0496 200.00 2.31% 2.90% 3.13% 3.54% 3.96% 4.24% 4.44% 1.68% 1.41% 0.85% 0.20% [1] Where power flow is in the conventional direction, i.e. from the HV side to the LV side of the transformer, positive figures indicate voltage drop values and negative figures (i.e. the shaded areas) indicate voltage rise values. This convention is reversed where power flow is in the opposite direction (e.g. due to generation). [2] A demand customer with a leading power factor imports real power and exports reactive power. A generator operating with a leading power factor exports real power (kw) and imports reactive power (kvar) POL:SD4/7 September 2017-11 of 12 -

APPENDIX A SUPERSEDED DOCUMENTATION This document supersedes POL:SD4/6 dated February 2017 which should now be withdrawn. ANCILLARY DOCUMENTATION National Engineering Recommendation P2, Security of Supply APPENDIX B National Engineering Recommendation P29, Planning limits for voltage unbalance in the United Kingdom National Engineering Recommendation P28, Planning limits for voltage fluctuations caused by Industrial, Commercial and Domestic equipment in the United Kingdom National Engineering Recommendation G5, Planning levels for harmonic voltage distortion and the connection of non-linear equipment to transmission systems and distribution networks in the United Kingdom. National Engineering Recommendation G59, Recommendations for the connection of generating plant to the electricity systems of Licensed Distribution Network Operators. National Engineering Recommendation G74, Procedure to meet the requirements of IEC 909 for the calculation of short-circuit currents in three-phase AC power systems POL:AM5, Technical Appraisal, Approval and Post Investment Appraisal for Network Relating Capital projects ST:AM5C, Technical Appraisal Approval and Post Investment Appraisal for Network Related Capital Projects POL:FI 06/04/01, Capital expenditure and project management - Investment appraisal, financial recommendation, and approval of capital sanctions KEY WORDS APPENDIX C HV, system, design, security, imbalance, fluctuation, harmonics, utilisation, regulation. POL:SD4/7 September 2017-12 of 12 -