OCCUPANCY SENSOR REMOTE USER GUIDE

Similar documents
FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

High/Low Bay Passive Infrared Occupancy Sensor

Single-zone Daylighting Control Sequences of Operation. Topic: DLM Operation with LMLS-400 Photosensor, v2.xx Issue: # TB185 Date: March 10, 2012

Installing the FSP-211 Sensor in Light Fixture

CONTINUOUS DIMMING MOTION SENSOR & COMPATIBLE REMOTE PROGRAMMER MSITXLRD509 & RMTITXSRP280

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

This document is intended for Lighting Control Systems professionals


HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

Fixture Built-in Sensor Daylight Harvest Version

MANUFACTURER MODEL NUMBER LUMENS COLOR TEMPERATURE OPTIONS 3100LM 4500LM 5800LM

Philips Ledalite Phone: Fax: Web: Programming Guide Version 2.0

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

HBL Series High Bay LED

Wireless Ceiling Mount Sensor for Occupancy / Vacancy Detection INSTALLATION GUIDE

with Light Level, Isolated Relay and Manual On features

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

RPT LEDCF 4000K LEDCF LOW-PROFILE LED CANOPY LUMINAIRE PART NUMBER BUILDER

Wireless Ceiling Motion Sensor for Occupancy / Vacancy Detection with integrated diagnostic tools INSTALLATION GUIDE

v3 360 Passive Infrared Line Voltage Occupancy Sensor

Crestron CLS-C6 Series ilux Integrated Lighting System User Guide

Radio Window Sensor and Temperature Sensor Programming in HomeWorks QS

Wireless Occupancy Sensor User Guide

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

Data sheet. Function description. Benefits

Model # PCYFC-10kW-250A PCYFC-20kW-250A PowerCycle Battery Conditioner Operation Manual

Installation Instructions

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

OCC Motion Sensor. Guide: how to program and use

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

SIMPLUX Standalone Wireless Lighting Control System Setup guide Light is OSRAM

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

Planning Guidelines. Lightcloud. Best Practices for Installing Lightcloud

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

Installation Instructions

Product Specifications

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

LEDCF LOW-PROFILE LED CANOPY LUMINAIRE

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide

RF Wireless Version On/off Control

BATTERY MONITOR User Manual

Wireless Ceiling Mount Sensor

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

Model 532 ma/v Loop Calibrator with Loop Diagnostic Operating Instructions

LightFlex Tunable-White LED nlight Programming Guide Programming Guide Overview

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Model OI-6940 Notis Quad 4-Gas Sensor Assembly

Introducing the 3000T Series Electronic Faucet Programming Guide Posted: 02/02/2006

Human Centric Lighting System

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Model No. DFC Support DIGITAL ENHANCED GAS FIRED MODULATING CONTROL

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow

netzerotools.com USER GUIDE Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter LED Light Meter Model LT45 netzerotools.

Connect + compatible

Allure RS-Smart-Sense. End-User Manual

Motorola APX. G1 SCBA Radio Pairing Guide Motorola APX. G1 SCBA Radio Pairing Guide for

Application Programs Descriptions

Qflash Pilot QF9. Shoe Mount Wireless Radio Commander for Qflash 5d-R and TRIO. F tested to comply with FCC standards. Operating Instructions

Model 12200A RCN PTAC/PTHP/FAN COIL CONTROL NODE OPERATION OUTPUTS G1 = FAN 1 G2 = FAN 2 G3 = FAN 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR

XIM Gen4 Sensor Programming Examples. Rev /05/2016

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

FT-2500 Advanced Tachometer Operation manual

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

ivu Series TG Image Sensor

Marshall Electronics. Full-HD (3G/HD-SDI) Mini-Broadcast POV Cameras. CV343, CV502, CV345, CV505 models. Operation Manual

luxcontrol DALI MSensor 5DPI 14 Product Manual

Quick Start. DTA Self-Install Guide

RSS Rectilinear Suspended Series

R2009/R3016 Radar system Quick Reference Card

Operation Manual Full-HD Miniature POV Camera

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications

INSTRUCTION MANUAL IMPORTANT: Please read this manual in its entirety prior to using this device!

Electrical devices may only be mounted and connected by electrically skilled persons.

NX Series Inverters. HVAC Pocket Programming Guide

Job Name VITAMIN COTTAGE / NATURAL GROCERS WARRENTON OR. Bid Date Dec 13, Submittal Date Dec 13, 2017

Maestro Occupancy Sensor C L Dimmer Additional Programming, Installation, and Troubleshooting Help

WATTSTOPPER OEM SENSOR GUIDE INTEGRATED LIGHTING CONTROLS. designed to be better.

S! Applications & Widgets

Pressure Field Unit User Guide

BIPRO-S600VF12 and BIPRO-S700VF50 OSD Manual. Please visit these product pages for more information on the BIPRO-S600VF12 and BIPRO-S700VF50 Cameras

VIENTO LARGE SITE & AREA LED LUMINAIRE

ECM HIGH EFFICIENCY CIRCULATORS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

CX105 Conductivity/Resistivity Transmitter

CCTV P TVI HD Camera USER S MANUAL THANKYOU FOR PURCHASING OUR PRODUCTS, PLEASE READ THE MANUAL CAREFULLY BEFORE OPERATION.

LED LOW-PROFILE CANOPY CPL SERIES

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium

TRACEABLE RADIO-SIGNAL REMOTE THERMOMETER INSTRUCTIONS

opponent; your phaser says tagged. Number of tags is shown on your display after the letter T. How to Play:


LP B C D E F G H I MOUNTING FINISH

STC-KNX (32-channel AP)

Transcription:

OCCUPANCY SENSOR REMOTE USER GUIDE Use the handheld programming remote to test and adjust the settings of your occupancy sensor, which can accommodate up to six sensor parameter profiles. FSP-2X1 is the occupancy sensor installed in your fixture. On/Off Select FSP-2x1 FSP-2X1 HBP-111 BAT= Battery Three bars indicates full charge. Back Go back one screen. Changes in progress will not be saved. Return to Main Menu Select Activate a menu or field to adjust its settings. Arrows Press to navigate from one field to another or adjust settings. Press and hold to move faster through increments.

After selecting your sensor, you can adjust parameter settings, view current settings, copy settings from one sensor to another, test parameters, or manually turn your light on/off. Adjust Settings To adjust parameter settings, highlight New Settings on the Sensor Configuration menu. Point the remote at the desired sensor and press the Select button. Once all settings are finalized, select Save. The following parameters can be adjusted for each sensor. High Mode The maximum brightness the light turns on to when motion is detected. High Mode: <10 Vo lts> Low Mode: <1 Vo lts > Time Delay: <5 M i n > <1 h o u r > N EXT Low Mode Recommended: 10 V Range: 0 10 V Increment: 0.2 V Default: 10 V Light output is decreased to this minimum when motion is no longer detected. Used with Time Delay. High Mode: <10 Vo lts> Low Mode: <1 Vo lts > Time Delay: <5 M i n > <1 h o u r > N EXT Recommended: 1.0 Range: 0 (off) 9.8 V Increment: 0.2 V Default: 1 V

Time Delay Number of minutes with no movement after which light output fades to Low Mode. High Mode: <10 Vo lts> Low Mode: <1 Vo lts > Time Delay: <5 M i n > <1 h o u r > N EXT Cut Off Recommended: 5 minutes Range: 30 seconds or 1 30 minutes Increment: 1 minute Default: 5 minutes Period of time with no movement before the lights turn off (after fading to Low Mode). Can be disabled. High Mode: < 10 Vo lts> Low Mode: < 1 Vo lts > Time Delay: < 5 Min> < 1 h o u r > < D i s > NEXT Sensitivity Recommended: 1 hour Range: 1 59 minutes or 1 5 hours Increment: 1 minute or 1 hour Default: 1 hour The motion sensitivity level of the sensor. High Mode: < 10 Vo lts> Low Mode: < 1 Vo lts > Time Delay: < 5 Min > < 1 h o u r > < D i s > NEXT Recommended: Max Range: On-Fix, Off-Fix, Low, Med, Max Default: Max

Setpoint When motion is detected, the ambient light level (foot candle) threshold that keeps the lights off or at the low setting. High Mode: < 10 Vo lts> Low Mode: < 1 Vo lts > Time Delay: < 5 Min > < 1 h o u r > < D i s > NEXT Ramp Up Recommended: Disabled Range: Auto, Disable, 1 fc to 250 fc Increment: 1 fc Default: Disable How quickly the light increases from Low Mode to High Mode. FSP- 2X1 Setti n g s Ramp Up: Fade Down: Photocell: < Dis> PRIO R S AVE SEN D Fade Down Recommended: Disabled Range: 1 60 seconds Increment: 1 second Default: Disable When Time Delay is reached, the light fades from High Mode to Low Mode. Recommended: Ramp Up: Fade Down: Pho t o cell : PRIOR SAVE SEN D Disabled Range: 1 60 seconds Increment: 1 second Default: Disable

Photocell On/Off When light level exceeds this setting, the light turns off even if the space is occupied. The sensor will monitor for a short period of time to confirm the light level increase is not temporary before forcing the light off. FSP- 2X1 Setti n g s Ramp Up: Fade Down: Pho t o cell : Recommended: Disabled Range: 1 250 fc Increment: 1 fc Default: Disable View Current Settings To view the current settings in read-only mode, highlight Current Settings. Point the remote at the desired sensor and press Select. Light Level PRIOR S AV E S E N D The light level reading can be used as a reference for setpoint adjustments. Copy Settings After you adjust parameters for one sensor and saved them as a profile, you can copy them to surrounding sensors using the Recall Profiles feature. To use existing settings on another sensor, highlight Recall Profiles, point the remote at the desired sensor, and press Select. Select the desired profile and press Select again.

Test Parameters To test a sensor s parameters, point the remote at the sensor with Test Mode highlighted, and press Select. Test Mode will disable after 10 minutes. Note: Test Mode shortens the time delay to allow quick verification of coverage for motion detection. Troubleshooting If the display does not come on after pressing the power button, do the following, make sure the batteries are charged and installed correctly. If the No Response screen appears, do the following: Make sure there are no obstructions between the remote and the sensor, and try again. Move closer to the fixture. Adjust the angle of the remote to point more directly at the sensor. Make sure the light fixture has power. If the sensor is still unresponsive, there may be too much IR interference from other sources. Try programming the sensor at night when there is no daylight.