Sirius F 250 Handbook (Page 1 of 5) Part Number 17133

Similar documents
NV100 Handbook Part Number 17195

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

AC/DC Power Supply Series APPLICATION NOTE

AC/DC Power Supply Series APPLICATION NOTE

NEVO+1200M. 6 x6 x W. 1.2kg DATA SHEET MAIN FEATURES

AC/DC Power Supply Series APPLICATION NOTE

Industrial Serie +600S

AC/DC Power Supply Series APPLICATION NOTE

Output Power (W) Industry Leading Performance. Fuse

General. Environmental. EMC & Safety

Voltage Adjustment. Load Regulation

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

NV-350 / NV Watts Modular power solution With up to 1450W peak rating for 10 seconds

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

SPECIFICATION FOR APPROVAL

300µA max at 264Vac & 63Hz (normal condition, 500µA Single Fault Condition) Adjustment Range V V. Channel

NV-350 / NV W W Modular power supply. Features Benefits Input How To Create A Product Description NV3 Converter NV3 3 NV7 7

TEST REPORT IEC Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements

AC/DC Power Supply Series APPLICATION NOTE

Electrical Specifications

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

CCH400 & CCH600 Series

Inrush Current (cold start)

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

Electrical Specifications

Electrical Specifications

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Electrical Specifications

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Power Supplies 3. SDN-C Compact DIN Rail Series

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

Power supply CP-D 24/4.2 Primary switch mode power supply

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

NV /180/200 Watts AC/DC Flexible Power Solution

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Electrical Specifications

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

Low cost of ownership. Adjustment Range V V V. Channel V / 15A 2.7V / 15A 3.3V / 15A Omit 5V / 10A 10 Omit 5V / 8A 8 Omit

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Power supply CP-D 12/2.1

Low cost of ownership. Input Frequency. Adjustment Range V V V. Channel 3 3

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

General. Environmental. EMC & Safety

TEST REPORT IEC Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Output Voltage (Vfan) & Current

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

Power supply CP-E 24/2.5

Kattegat JP Groningen, The Netherlands High Efficiency High Power Audio SMPS

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

Power supply CP-E 24/20.0

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

Power supply CP-D 24/1.3

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

NV W Configurable power supply. NV-300. Input. How To Create A Product Description. QUICK SELECTOR - example configurations

1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W

Product Specification

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/0.75

Power Supplies. SCL Series. Features. Related Products. Applications

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Input Frequency. Input Fuse 6.3A Fast acting (not user accessible) Inrush Current 15A typical at 25 C and 230Vac (cold start) Earth Leakage Current

Power Supplies. Certifications and Compliances Recognized Component, ITE - UL Certified, ITE - CSA C22.2 CSA

Power supply CP-T 24/10.0 Primary switch mode power supply

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

DSM Dynamic Shunt

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

TB65 65W Single Output Test and Measurement/Industrial Series

PSU s e r i es

C B. Models. Models 2MOPP

American Power Design, Inc.

Power supply CP-T 24/40.0 Primary switch mode power supply

1500W Single Output Power Supply AK V 100A 0~100A 1500W. 150mVp-p. Adjustment of output current is between 40 ~ 105% of rated output

3000W Single Output Power Supply AK V 200A. 0 ~ 200A 3000W 150mVp-p

PRetrans Table of contents

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

3000W Single Output Power Supply AK V 24V 250A 200A 125A 0 ~ 250A 0 ~ 125A 3000W 0 ~ 200A. 3000W 150mVp-p 3000W

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

Transcription:

Sirius F 250 Handbook (Page 1 of 5) Part Number 17133 Input Parameters NOMINAL INPUT VOLTAGE RANGE MAX. INPUT VOLTAGE RANGE INPUT FREQUENCY MAXIMUM INPUT CURRENT INRUSH CURRENT Output Parameters 94.5-240VAC or 133-330VDC 85-264VAC or 120-360VDC 47-63Hz or DC 5A AC or 3.4A DC <50 AMPS Adjustment and Derating. The Sirius F 250 series is designed to provide a max output power of 250W at nominal output voltages. The following procedure must be used to ensure the PSU is operated within its ratings. a Calculate user power for each module (volts x amps). b Add all the individual module powers together. The total power must not exceed the value given in the following tables. c Calculate secondary transformer turns x amps for each module. (See outputs table for transformer secondary turns). d Add all the module turns x amps together and this must not exceed 90AT. e If necessary reduce the loading until the conditions are met, ie. power and ampere-turns maxima. OUTPUTS Cooling,Output Power and Output Current Limitations (see Tables 1, 2 & 3) i) Power limitation method. Table 1 Customers Airfl ow (all orientations) (NM *) Normal Airfl ow (air into unit at input end) Reverse Airfl ow (air into unit at output end) 2.5m/sec 3m/sec 2.5m/sec 3m/sec 220W/90AT for 85-90VAC I/P, 250W/90AT for 90-264VAC I/P or 120-360VDC I/P 240W/90AT for 85-90VAC I/P, 250W/90AT for 90-264VAC I/P or 120-360VDC I/P Table 2 Integral Fan Cooling (all orientations) 150W/70AT at 40 C ambient, both derating at 2.5% / C to 50 C max Normal Airfl ow (air into unit at input end) (SI, SIF, EI, EIF) Top Fan with Molex (TM) End Fan(s) with Molex (EM & SM) End Fan(s) with IEC (SI, SIF, EI, EIF) 250W/90AT 250W/90AT 250W/90AT 150W 56AT Reverse Airfl ow (air into unit at output end) End Fan with IEC (EIR & EIFR) 200W/90AT at 40 C, both derating 2.5% / C to 50 C Max * Orientations not approved for NM version are vertical with the input end at the bottom and horizontal with the base of the unit uppermost. ii) Temperature Measurement Method: The following method must be used for determining the safe operation of PSU s with the LM option (open frame). It may be used as an alternate method to (i) above, for determining the safe operation of NM option PSU s. For PSU s cooled by customer supplied airfl ow the components listed in the table below must not exceed the temperatures given (including when the end use equipment is operated at its maximum permitted ambient), consequently the maximum temperature rise permitted is given by the temperatue given in the table minus the T mra (maximum ambient) of the end use environment (maximum permitted T mra is 50 0 C). All other ratings given in this handbook remain unchanged except that the maximum output power is 250W. To determine the component temperatures tests must be conducted in accordance with the requirements of IEC/EN/UL/CSA 60950-1 clause 4.5: Consideration should also be given to the requirements of other safety standards. Note: Max. temperatures given are as required by IEC/EN/UL/CSA 60950-1 or to provide satisfactory reliability, whichever is the lower. Test requirements include: PSU to be fi tted in its end-use equipment and operated under the most adverse conditions permitted in the end-use equipment handbook/specifi cation and which will result in the highest temperatures in the PSU. To determine the most adverse conditions consideration should be given to the maximum operating ambient, PSU loading and input voltage, ventilation, equipment orientation, the position of doors & covers, etc. Temperatures should be monitored using type K fi ne wire thermocouples (secured with cyanoacrylate adhesive, or similar) placed on the hottest part of the component and the equipment should be run until all temperatures have stabilised. Table 3 Circuit Ref Description Max Temp ( 0 C) TX1 Power transformer primary, secondary and core 130 TX2 Drive transformer windings 110 L1 & L6 Choke winding 110 L12 Choke winding and core 120 - All other choke windings 115 F1 Input fuse end cap and clip 100 C1 & C18 X capacitors 100 C5 Reservoir electrolytic capacitor 85 - Electrolytic capacitors < 10mm diaameter 90 - Electrolytic capacitors >- 10mm diameter 95 Refer to drawing on page 5 for components to be monitored. Output Ratings Module Transformer Turns Voltage Range CH1 ** Voltage Range CH2 ** Short Circuit Current * Current O/P1 (3V) 1T 1.8-3.8V - 90A 30A O/P1 (5V) 2T 4.5-7.5V - 45A 25A O/P2 (5V) 2T - 4.5-6V 45A 20A O/P2 (12V) 3T - 9-13V 30A 10A O/P2 (24V) 6T - 18-25V 15A 6A A 2T + 2T 4.5-6V - 45A 10A B 4T + 4T 9-16V - 23A 8A C 7T + 7T 17-30.V - 13A 4A D 2T + 2T 4.5-6V 2.7-4V 45A/45A 5A/5A E 2T + 4T 4.5-6V 9-16V 45A/23A 5A/4A F 2T + 7T 4.5-6V 17-30V 45A/13A 5A/2A G 4T + 4T 9-16V 9-16V 23A/23A 4.5/4.5A*** H 4T + 7T 9-16V 17-30V 23A/13A 4A/2A J 7T + 7T 17-30V 17-30V 13A/13A 2A/2A L 1T 1.8-3.8V - 90A 14A M 2T + 2T 4.5-6V 4.5-6V 45A/45A 5A/5A N 4T + 4T 9-15.5V - 23A 8A *Maximum current if output is short circuited, within 1 minute current limit changes to hiccup mode to give a lower average current. **These voltages are at the output power terminals and must be reduced by a line drop when remote sense is used. *** For PSU S with a single end fan rating is 4/4A. Custom Models Specifi c confi gurations with different operating perameters to the rest of the range are permitted. These are as follows: a) CSF 250 SM 3.3/5 15B 15/24H Loading Conditions Output 1 3.3V@18A Output 2 5V@13A Output 3 15V@2A Output 4 15V@0.5A Output 5 24V@0.25A This unit, with these maximum loading conditions, can operate with a maximum ambient of 60 C horizontally. b) CSF 250 NM 6.5/12 5/3.3D 12/26H Loading Conditions Output 1 6.5V@1.2A Output 2 12V@4A Output 3 5V@3.6A Output 4 3.3V@1.5A Output 5 12V@0.2A Output 6 26V@0.5A There is no internal fan with this unit, cooling is provided externally. Airfl ow is to be supplied at a minimum of 1.5m/s at the inptu end of the unit, drawing air from the output end towards the input end. This unit, with these maximum loading conditions, can operate with a maximum ambient of 60 C horizontally c) CSF 250 TM 5.2/24 12/12G 15/15G Loading Conditions Output 1 5.2V@9.04A Output 2 24V@4.38A Output 3 12V@2.5A Output 4 12V@0.5A Output 5 15V@4.8A Output 6 15V@1A This unit uses a Papst 8412MNLE fan and can be used in all orientations except fan facing downwards, with a minimum input voltage of 90Vac.

Sirius F 250 Handbook (Page 2 of 5) Part Number 17133 Safety approvals These products carry the following approvals: UL60950-1 and CSA22.2 No.60950-1 - UL Recognised. C-UL for Canada. IEC/EN60950-1 - CE mark. CE marking when applied to any Sirius product, indicates compliance with the Low Voltage Directive (2006/95/EC) in that it complies with EN60950-1. Input markings and symbols Environmental parameters alternating current (a.c.). direct current (d.c.). danger, shock hazard. caution, refer to supplementary documents. Operation Temperature 0 to 50 0 C (derating 2.5% 0 C above 50 0 C to 65 0 C -Not covered by approvals). Humidity 5 to 95% RH non-condensing. Air Pressure 78kPa to 106kPa. Altitude -200m to 3000m Storage and Transportation Temperature -40 0 C to +85 0 C. Humidity 5% to 95% RH non-condensing. Air Pressure 54kpa to 106kpa. Altitude -200m to 5000m. Vibration and shock 10-200Hz @ 1.5G sinewave, 20G for 15 minutes in 3 axes random vibration / 3000 bumps, 10G (16mS) half sinewave. Cooling These units may be mounted in any orientation, unless stated otherwise. The airfl ow around the power supply air inlets and outlets must not be impeded when it is fi tted in the end use application. Level of insulation Dielectric Strength testing is carried out as follows: Primary mains circuit to earth 2.25-2.35 KVDC *Primary mains circuits to transformer core 4.25-4.35 KVDC *Primary mains circuits to secondary 4.25-4.35 KVDC Outputs to each other and to earth are isolated to 100 VDC except: i) Output 1 and output 2 on the 3/5 base boards. ii) Outputs of twin D module to each other. *Important Note: This test is not possible with Y capacitors fi tted to the unit as damage to these capacitors will occur. It is also necessary to short circuit the outputs together and to earth. EMC performance Emissions : EN55022 Conducted RFI-Class A or B (depending on product - Consult Technical Sales). Radiated RFI - Class A. EN61000-3-2 - Pass - Class A and D. EN61000-3-3 - Pass Immunity: EN61000-4-2 - Level 4 Criteria B EN61000-4-3 - Level 3 Criteria B EN61000-4-4 - Level 4 Criteria B EN61000-4-5 - Level 3 (Installation Class 3) Criteria B EN61000-4-6 - Level 3 Criteria B EN61000-4-11 - Pass VDE 0160 - Class 2 (Clause 7.3.1.1.) General installation instructions i) The Sirius family of component power supplies is designed for use within other equipment or enclosures which restrict access to authorised competent personnel only. For safe installation and operation of this product, carefully follow the instructions below. ii) The unit cover/chassis is designed to protect skilled personnel from hazards. They must not be used as part of the external covers of any equipment where they may be accessible to operators, since under full load conditions, part or parts of the unit chassis may reach temperatures in excess of those considered safe for operator access. On units with end fans and IEC60320 connector, the fan and connector end of the unit is permitted to be user accessible, this also applies to the top fan on units where this is fi tted. Enclosures made with punched ventilation grilles are not to be user accessible. iii) The mains switch, where fi tted, is a single pole device and must not be used as the main disconnect device. The IEC60320 mains appliance coupler is intended to be the main disconnect device for the Sirius power supply. The switch is marked I and O. The I indicates on and O indicates off. CAUTION: Where the IEC60320 is fused, then it is double-pole/neutral fused. When the fused IEC60320 inlet is fi tted, the IEC input must not be user or externally accessible in the end use equipment. iv) These products are Class 1 and must therefore be reliably earthed and professionally installed in accordance with the prevailing electrical wiring regulations and the safety standards covered herein. v) These products are IPX0 and chemicals/solvents, cleaning agents and other liquids must not be used. Mechanical parameters DO NOT USE MOUNTING SCREWS WHICH PENETRATE THE UNIT BY MORE THAN 4.5 MM. Weight 2.4 Kg dependent upon confi guration. Important safety instructions Servicing These products are not customer serviceable. Repairs may only be carried out by Lambda UK or their authorised agents. These products are not authorised for use as critical components in nuclear control systems, life support systems or equipment for use in hazardous environments without the express written approval of the Managing Director of Coutant Lambda Ltd. Energy and Voltage Hazards Certain modules are capable of providing hazardous energy (240VA) according to output voltage setting. Final equipment manufacturers must provide protection to service personnel against inadvertent contact with these module output terminals. If set such that hazardous energy can occur then the module terminals or connections must not be user accessible.non-seriesed outputs that are earthed in the end use equipment are SELV.If outputs are not earthed they must be considered hazardous, as a single fault in the secondary may make them exceed the SELV limits between output and earth. If any output is non-selv then all outputs become non SELV. Outputs connected in series may produce non-selv levels, and this must be taken into account in the end-use application. Approval Limitations: Use in North America (AC units only) When this product is used on 180VAC-250VAC mains with no neutral, connect the two live wires to L(live) and N (neutral) terminals on the input connector. In this instance double pole fusing is required. High Voltage Warning Dangerous voltages present within the power supply. Do not remove covers. External Hot Surfaces Section 6 of the Health and Safety at Work Act requires that manufacturers have an obligation to protect service engineers as well as users. In order to comply with this, a label must be fi tted to these products which is clearly visible to service personnel accessing the overall equipment, and which legibly warns that surfaces of these products may be hot and must not be touched when the products are in operation. Safety Class of Protection These products are designed for the following parameters : Material Group IIIb, Pollution Degree 2, Overvoltage Category II, Class 1 (earthed), Indoor use as part of an overall equipment such that the product is accessible to service engineers only. Safety Earthing Screw On products with an enclosure, special safety earthing screws are used which connect the cover to the chassis. They must not be removed.

Sirius F 250 Handbook (Page 3 of 5) Part Number 17133 Connection details Input Connections Input tabs - 6.3mm x 0.8mm, tin plated brass, rated 15A. Internal fuse (F1) 6.3 x 32mm, F6.3AH/250V. Sirius F250 Outline Drawing - Top Mounted Fan Sirius F250 Outline Drawing - End Mounted Fan (includes molex opt) Output Connections Output Connector Ratings: 6.35mm fastons are rated at 15A. CUSTOMER SIGNALSUUCUSTOMER SIGNALS Customer Signals Customer signals are available via 8-way connector (PCB reference J7) adjacent to output 1 terminals. A connector kit (Molex housing 90142 and Molex crimp pins 90119-2109) is supplied with each PSU. Pin designations for this connector are as follows: PIN FUNCTION 1 Ch1 -ve sense 2 Inhibit 8 7 6 5 3 A/C Fail/Reset 4 Ch2 -ve sense 5 AC Good/Reset 6 Ch2 +ve sense 4 3 2 1 7 Ch1 -ve sense 8 Ch1 +ve sense Inhibit (Pin2) Connecting Pin2 (Inhibit) to Pin1,7 (Ch1 ve sense) via open-collector driver or relay/switch contact shuts off all DC outputs (cooling fan continues to operate). Pin2 is internally pulled high via 2K2 resistor to a 5Volt supply with respect to Pin1,7. AC Fail/Reset (Pin3) Pin3 (AC Fail/Reset) is an open-collector output referenced to Pin1,7 (Ch1 ve sense) that is normally low and goes high at least 5mS before DC outputs are lost. Maximum sink current is 16mA, the signal is pulled high internally via 2K2 resistor to a 5Volt supply. AC Good/Reset (Pin5) Pin 5 (AC Good/Reset) is an open collector output referenced to Pin1,7 (Ch1 -ve sense) that is normally high and goes low at least 5mS before DC outputs are lost. The signal can also be used to provide a power-on reset function. At power-on, pin5 goes high minimum of 100mS after DC outputs have established. Maximum source current is 16mA, the signal is internally pulled low via 2K2 resistor to Pin1,7 (Ch1 -ve sense). Ch1/Ch2 sense (Pins1,4,6,7,8) Connecting sense terminals to the load will compensate for power cable voltage drop under load conditions. With sense terminals connected, the voltage drop along any power cable should not be allowed to exceed 0.5volts. The sense terminals can be left unconnected if remote sense is not required (sense terminals are internally connected via a 10ohm resistor to the corresponding power terminal). Sense cables should be connected as twisted pairs (+ve and -ve sense) with at least 1 twist per centimeter and sense cable harness should be kept separate from the power cable harness wherever possible.

Sirius F 250 Handbook (Page 4 of 5) Part Number 17133 Sirius F250 Outline Drawing - Single Fan Sirius F250 Outline Drawing - No Fan Max screw torque for customer fi xings 0.9Nm

Sirius F 250 Handbook (Page 5 of 5) Part Number 17133 CEL Part No. 17133 Issue 19 October 2007 Coutant Lambda Limited, Kingsley Avenue, Ilfracombe, Devon, EX34 8ES. Telephone - Sales and Service (01271) 856666. Head Offi ce and Works (01271) 856600. Facsimile (01271) 864894. WEBSITE: www.lambda-gb.com