SUPPLEMENTARY INSTALLATION INSTRUCTIONS Ventilating Fan (Contractor Pack)

Similar documents
GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

MasterFlow Green Machine Dual Powered Roof Vent

General Installation Instructions

Installation Instructions (For Dealer or Contractor)

General Installation Instructions LED

INSTALLATION INSTRUCTIONS FOR WHOLE HOUSE FANS CAUTION

IMPORTANT! READ BEFORE PROCEEDING! SV Weather Caps

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

Healthcare LED TROFFER FLANGE (HSTLED Family)

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

FW / FIG Partition Kit(s) Installation Instructions

1/4in. SHEET PALM SANDER

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

Installation Instructions

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

WHITE - Accessories. Series 500 Greenhouse Kit w/blackout System, Ventilation & Evaporative Cooling

Rough-In Frame OVERVIEW OF INSTALLATION PROCEDURE PLANNING GUIDE MODEL IR-105 INSTALLATION DON'TS

MADELINE METAL CHANDELIER

Installation Instructions: T-Lite LED Signage Tube Lamps

ZIP CLOUD SUSPENDED INSTALLATION MANUAL

Installation Instructions

Type XTSR71 Sizes

Lightplane 3.5 Recessed

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

PORTABLE HALOGEN WORK LIGHT OWNER S MANUAL

BEFORE YOU BEGIN Read these instructions completely and carefully.

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

Custom Pendant- Hardwire Assembly and Installation Instructions

Senior Swing. Caution

Installation Manual. (for qualified service personnel) Table of Contents. For Your Safety... 39

ROPE CHANDELIER - FRAME ASSEMBLY & INSTALLATION INSTRUCTIONS

GENERAL OPERATIONAL PRECAUTIONS

Wall Mount Dust Collector 650 CFM Instructions

Round or Square Chicago Plenum Down Light Housing with Lamp

EOS LED Surface Mounted Luminaire

Page 1 of 6 Systems Inc.

Instructions for Stone Cutting Machine

Installation Guide. SN-LM42 Brilliance Series Photoluminescent Area of Rescue Signs

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

Over the Range Microwave Oven

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles.

Fabric tiered drum pendant 30in Assembly and Installation Instructions

SHELTON THERMOSTATIC SHOWER PANEL

Nash Chandelier Assembly and Installation Instructions

Installation Instructions

ELECTRIC RANGE INSTALLATION MANUAL. Please read these instructions thoroughly before installing and operating the range.

RESIDENTIAL MOTORIZED STORAGE UNIT


MaxLite Linear Strip ECO Series

INSTALLATION INSTRUCTIONS LARGE FLAT PANEL IN WALL ENCLOSURE Model: PAC-500

Thanks for shopping with Improvements! 7 ft. Wall Christmas Tree w/ Stand Item #419359

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

DRILL BIT GRINDER MODEL: MR-26A

Angle Grinder MODEL 9553B MODEL 9555B

SECTION LOW PRESSURE DUCTWORK

DUST COLLECTOR 70 GALLON, 2 HP

BEFORE YOU BEGIN Read these instructions completely and carefully.

Dust Collector. Model No: DC2200 (FM300S)

LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT CM2420

CAELI THERMOSTATIC SHOWER PANEL

Installation Instructions In-bottom/Out-back Cooling Kit for E3h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302

10" Wet Tile Cutting Saw

TOYOTA TACOMA 2005 TRAILER WIRE HARNESS Preparation

Installation Instructions

Pow-R-Feed Systems Service Manual

BEFORE YOU BEGIN Read these instructions completely and carefully.

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

GARAGE DOOR WITH TORSION SPRING

CAUTION: BEFORE INSTALLING THE LUMINAIRE, MAKE SURE THAT THE CURRENT IS CUT TO THE BOX FUSES / MAIN CIRCUIT BREAKER.

FREUD. Operating Instructions. JS104K Biscuit Joiner Kit

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

ClearSpan Mini Grab Bag Shelters

TOYOTA TACOMA TRAILER WIRE HARNESS Preparation

3HP BAG CYCLONE DUST COLLECTOR MANUAL

GENERAL OPERATIONAL PRECAUTIONS PRECAUTIONS ON USING CUT-OFF MACHINE

EC MOTOR SUPPLEMENTAL MANUAL

Installation and Operation Manual. Ajustable Valance Kits CAUTION: Duke Manufacturing Co.

Blackout Fan Kits with Breathable Wall Light Traps

VERTICAL PLATFORM LIFT

EOS Direct/Indirect LED Pendant Luminaire

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

ClearSpan Mini Grab Bag Shelters

MEC Auto-Mate Assembly Manual. For MEC 9000G/GN and 8567 Grabber Series

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

2011 / Circuit Tracer

Horizontal Array Bracket Installation Instructions

Woven Leather Chandelier Large Assembly and Installation Instructions

Sliding Door Kit

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

M o d u l a r Design

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

Installation Instructions

INTERIOR DUCTWORK KIT

2018+ Mustang Corner Pockets Installation Instructions P/N: (R B972)

SAFETY DIRECTIVE 2.0 DEPARTMENTS AFFECTED. This Administrative Directive shall apply to all Town of Marana departments and employees.

INSTALLATION INSTRUCTIONS F Series Floodlight

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

Installation Manual. This installation is for the Odyssey H1800 Series Ventilation System.

Transcription:

SUPPLEMENTARY INSTALLATION INSTRUCTIONS Ventilating Fan (Contractor Pack) Model No. FV-08VSLA2 Contents Housing Can FV-08VSLA2 General Safety lnformation Unpacking Supplied Accessories Wiring Diagram lnstallation ( Mounting- ) lnstallation ( Mounting- ) 2-3 3 5-7 7-8 lnstallation lnstallation lnstallation lnstallation ( - Mounting) (Between Mounting) (Wooden Header) (ln Existing Construction) 9 9-10 11 Back cover Product Service Back cover Motor/Light Kit/Grille Assembly FV-08VSLB2, FV-10VSLB2 Applicable to Model: FV-08VSL2, FV-10VSL2 READ AND SAVE THESE INSTRUCTIONS Thank you very much for having purchased our product. Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Failure to comply with instructions could result in personal injury or property damage. Please explain to users how to operate and maintain the product after installation, and this booklet should be presented to users. Please retain this booklet for future reference.

GENERAL SAFETY INFORMATION WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following: 1. Use this unit only in the manner intended by the manufacturer. lf you have any questions, contact the manufacturer. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified person (s) in accordance with all applicable codes and standards, including fire-rated construction.. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer' s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit lnterrupter) - protected branch circuit. 8. These models are UL listed for tub and shower enclosures. 9. Do not use this fan with any solid-state speed control device. 10. Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R0. 11. Do not disassemble the unit for reconstruction. lt may cause fire or electric shock. 12. A statement to the effect that when the product is to no longer be used, it must not be left in place but removed, to prevent it from possibly falling. 13. Ceiling joist must be subjected to static load more than five times the weight of the product. 1. The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are provided. 15. Do not install the product as the method which is not approved in the instruction. 16. This product must be properly grounded. 17. The Housing Can FV-08VSLA2 must be installed with Motor/Light Kit/Grille Assembly FV-08VSLB2 or FV-10VSLB2 that are marked on their Cartons to indicate the suitability with this model. Other Motor/Light Kit/Grille Assembly cannot be substituted. 2

GENERAL SAFETY INFORMATION CONTINUED CAUTION: 1. Do not install this ventilating fan where interior room temperature may exceed 10 F (0 C). 2. Make sure that the electric service supply voltage is AC 120V, 60 Hz. 3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA).. Always disconnect the power source before working on or near the fan, motor, light fixture or junction box. 5. Protect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 6. Do not kink the supply wiring. 7. Provide make up air for proper ventilation. 8. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 9. Do not install the unit where ducts are configured as shown in Fig. A. Prohibition Prohibition Prohibition Prohibition Adaptor 10. Not for use in cooking area. (Fig. B) Fig. A (Cooking area) Do not install above or inside this area 5 5 Cooking equipment Floor Fig. B UNPACKING Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. 3

SUPPLIED ACCESSORIES ( sets) (A) For Motor/ Light Kit/ Grille Assembly of model: FV-08VSLB2, FV-10VSLB2 Part name Appearance Quantity Part name Appearance Quantity Grille Lighting unit 32W Fluorescent lamp Screw (ST.2X16) 8 W Night lamp Machine screw (MX8) (B) For Housing Can of model: FV-08VSLA2 Part name Appearance Quantity Part name Appearance Quantity Screw (ST.2X8) 8 Long screw Machine screw (MX8) 2 Screw (ST.2X12) 8 WIRING DIAGRAM Wiring diagram White Black Electronic ballast Night lamp Fluorescent lamp Lighting unit Black Live (Light) White Neural Red White Capacitor Black Black Live (N.Light) Motor White White Black White Black Neural Live Power supply AC120V 60Hz Fuse in motor Thermally protected Green Green Earth ground Junction box

INSTALLATION (JOIST MOUNTING- ) 1. Before installation, secure the fan body to adaptor by using machine screw(mx8). (Fig.1) Machine screw (MX8) IMPORTANT: Remove the tape from damper and adaptor before installation. As shown below: Tape Fig. 1 A=12 inches Adaptor Damper 2. lnsert the suspension into the fan body and adaptor. (Select the suspension as shown below) Fig. 2-1 A=16 inches s Fig. 2-2 Spacing A on center joists lnsert A=19.2 inches(vertical joist) 12 inches Refer to Fig. 2-1 16 inches 19.2 inches vertical joists 2 inches Refer to Fig. 2-2 Refer to Fig. 2-3 Refer to Fig. 2- Fig. 2-3 lf spacing A on center joists is 2 inches, connect suspension and (C mark to C mark) as shown below: 2 Screw (ST.2X8) A=2 inches Fig. 2-5

INSTALLATION (JOIST MOUNTING- ) CONTINUED 3. Install the suspension and the flange of fan body to joists by using long screws. (If spacing A between joists is 10 1/ 12 inches, install the flange of fan body according to Fig.3-2, others according to Fig.3-1 install the product.). Install the suspension to joists by using long screws and secure it to the fan body by using screw (ST.2X12). (Fig.) A=10 1/ 12 inches Long screws Fig. 3-1 5. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig.5) 2 Long screws Fig. 3-2 6. Refer to wiring diagram (page ). Using wire nuts, connect house power wires to ventilating fan wires and lighting unit wires: black to black; white to white; green to green; Replace the junction box cover. (Fig.5) 2 Long screws Screw (ST.2X12) Fig. CAUTION: Mount junction box cover carefully so that lead wires are not pinched. 7. Squeeze the circular duct to fit the adaptor, then slipped onto the adaptor and secure it with duct tape. Junction box cover Knock-out hole Conduit Circular duct Duct tape inches Squeeze Conduit Junction box Wire nut Green wires Lead wires Fig. 5 6

INSTALLATION (JOIST MOUNTING- ) CONTINUED 8. Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. (Fig.6) 12 1/ 8 ( 305) 12 1 / 8 (3 0 5) 9.Follow the Fig.12-3,12-(page 9) and the Fig.6,7 (page 8) of the original installation instruction to complete the Motor/Light Kit/Grille Assembly installation. Ceiling Unit: inches (mm) Fig. 6 INSTALLATION (JOIST MOUNTING- ) 1. Disconnect plug connector from receptacle and remove adaptor from fan body before starting installation. Adaptor 2. Insert the suspension into the adaptor and secure it to joists by using long screws. (Fig.7) CAUTION: Backside of flange should mount directly to bottom of joist. 2 Long screws s If spacing A between joists is 21 1/ to 23 1/ 2 inches, connect suspension and (C mark to C mark) according to page 5. Select the suspension according to spacing A as shown below. Spacing A between s inches (mm) suspension 13 1/15 1/ 2 (33639) suspension 16 1/ 218 3/ (1980) suspension 21 1/ 23 1/ 2 (50597) suspension & 2 Long screws 13 1/15 1/ 2(33639) 16 1/ 218 3/ (1980) 21 1/ 23 1/ 2(50597) Adaptor 3. Follow step 5 to 7 of the installation (page 6) to complete the duct work and wiring.. Insert the suspension into fan body (refer to step 2 of Installation, page 5). Unit: inches (mm) Fig. 7 7

INSTALLATION (JOIST MOUNTING- ) CONTINUED 5. Insert the fan body into joists. (Fig.8) IMPORTANT: Make sure that adaptor claws are properly inserted Conduit Circular duct into body slots. Junction box cover 6. Secure the fan body to adaptor by using machine screw. (Fig.9) 7. Secure the suspension to joists by using long screws and secure it to fan body by using screw (ST.2X12) in vertical direction. (Fig.9) 8. Follow step 8 to 9 of installation (page 7) to complete the installation work. Adaptor claws Fig. 8 Screw (ST.2X12) 2 Long screws Machine screw Fig. 9 8

INSTALLATION ( - JOIST MOUNTING ) kinds of -joist inches (mm) hole mark C 9/16 (1.3) 11/16 (17.5) 31/32 (2.6) 1 17/32 (38.9) C1 C2 C3 C Screw (ST.2X12) C3 The suspension different kinds of -joist. C C1 C2 can comply with Fig. 10 1. Before installation, secure the fan body to adaptor by using machine screw (MX8). (Fig.1 of page 5) 2. Connect the suspension to fan body. (Fig.10) (Select the hole by checking -joist size fix the screw to the frame hole.) 3. Connect the ventilating fan to the -joist. (Fig.11). Follow step 5 to 9 of installation (page 6 page 7) to complete the installation work. I-joist Long screws Fig. 11 INSTALLATION ( BETWEEN JOIST MOUNTING ) 1. Before installation, secure the fan body to adaptor by using machine screw (MX8). (Fig.1 of page 5) A 16 inches and 19.2 inches horizontal joist 19.2 inches vertical joist 2. Insert the suspension into cover of adaptor side and the back of the fan body. (Fig.12-1,12-2) (select the suspension according to spacing A as shown right) A=16 inches and 19.2 inches horizontal joist Fig. 12-1 A=19.2 inches vertical joist Fig. 12-2 9

INSTALLATION (BETWEEN JOIST MOUNTING ) CONTINUED 3. Insert the fan body between joists. Make sure the fan body is level and square (perpendicular) with the joists. (Fig.13) s CAUTION: Backside of flange should mount directly to bottom of joist. Adaptor Junction box 13 1/ 15 1/ 2(336 39) 16 1/ 2 18 3/ (19 80) 21 1/ 23 1/ 2(50 597) Unit: inches (mm) Fig. 13. Secure the suspension to joists by using long screws. (Fig.1, Fig.15) 5. Secure the suspension to fan body by using screws (ST.2X12). (Fig.15) 2 Long screws Fig. 1 6. Follow step 5 to 9 of installation (page 6 page 7) to complete the installation work. 2 Screw (ST.2X12) Long screws Fig. 15 10

INSTALLATION (WOODEN HEADER ) 1. Before installation, secure the fan body to adaptor by using machine screw (MX8). (Fig.1 of page 5) Header 10 7/8 (275) 1 3/ ( 375) Adaptor 2. Install header between joists by using nails or screws. Unit: inches (mm) Fig. 16 3. Install the fan body and secure it by using long screws. (Fig.16, Fig.17) Circular duct Junction box 6 Long screws Conduit Junction box Wire nut. Follow step 5 to 9 of installation (page 6 page 7) to complete the installation work. Green wires Lead wires Fig. 17 11

INSTALLATION (IN EXISTING CONSTRUCTION ) 1. Installation in existing construction. Installing the fan body in an existing building requires an accessible area (attic or crawl space) above the planning installation location or existing ducting and wiring. (1) To install the fan body, follow the procedures described in lnstallation. Take the following precautions before installation. CAUTION: Check area above planning installation location to be sure that: 1. Duct work can be done and that area is sufficient for proper ventilation. 2. Wiring can be run to planning location. 3. No wiring or other obstructions shall interfere with installation. (2) Inspect duct work and wiring before proceeding with installation. (3) Plan suitable location for fan body. (next to ceiling joist) () Before installation, provide inspection and maintenance access at a location that will not interfere with installation work shown in installation (5) First, remove ceiling section according to Fig.6 of page 7. (6) Install fan body. 2. Installation from accessible area above fan location. (1) Inspect duct work and wiring before proceeding with installation. (2) Remove ceiling section according to Fig.6 of page 7. (3) Install fan body. PRODUCT SERVICE Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7292 (USA) or 1-800-669-5165 (Canada). Panasonic Corporation of North America One Panasonic Way, Secaucus, New Jersey 0709 www.panasonic.com Panasonic Canada lnc. 5770 Ambler Drive, Mississauga, Ontario LW 2T3 www.panasonic.ca Panasonic corporation 2012 Printed in China T0212-0 08VSLA220