Direct Operated Proportional DC Valve Series D1FP

Similar documents
Proportional Directional Control Valves Series D1FB. General Description. Features. D1FB*3 OBE Spool/Body Design. D1FB*0 OBE Spool/Sleeve Design

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

DENISON HYDRAULICS Proportional Pressure Control Valves

4/3 proportional directional valve direct operated, with integrated electronics

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

Proportional Directional Control Valves Nominal sizes 16 and 25

Proportional directional valves

DIN (NFPA/ISO/CETOP) NG6 (3) NG10

Pilot Operated Servo Proportional DC Valve Series D*1FP

4/3 Proportional Directional Valve, Size SAE 10

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control

PROPORTIONAL PRESSURE CONTROLS TECNORD

Proportional flow valves digital, pressure compensated, direct operated, with position transducer

Servo-Performance Proportional Directional Valves with Feedback. K(B)SDG4V-3 1* Series Pressures to 350 bar (5075 psi)

Electro-Hydraulic 4-Way Directional Servo Valve Model 4 WS 2 E.10 and 4 WSE 2 E. 10 (Series 4X) PSI (315 bar) K K

Directional control valve, direct operated, with integrated digital axis controller (IAC-Multi-Ethernet) Type 4WRPDH. Features.

Proportional Directional Control Valves Size 6

Proportional Directional Control Valves Series D*FH and D*FM General Description Operation Features Series D*FH Series D*FM

SERVO VALVES. Maximum Flow. Maximum Operating Pressure MPa (PSI) U.S.GPM Page. Graphic Symbols.

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH Series

Directional control valve, direct operated, with integrated digital axis controller (IAC Multi Ethernet) Type 4WRPDH. Features.

Electronic Temperature Transmitters

Proportional Directional Valves with Feedback KBFDG4V-5-2C75N45-Z-M1-PC7-H7-12-EN123/EN150. Pressures to 315 bar (4500 psi)

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH*-8 10 Series

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

LSV(H)G Series High-speed Linear Servo Valves

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH Series

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Digital electronic TEB/LEB drivers integral-to-valve format, for proportional valves with one or two spool position transducers

Electronically controlled proportional pressure regulating valves

Proportional Directional Control Valves Size 6

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Analog amplifier RA. RE Edition: Replaces:

Direct Drive Digital Control

User Manual. Proportional Directional Control Valve PRM7

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

OEM Relativ- und Absolut-Drucktransmitter OEM Relative and absolut pressure transmitter OEM Transmetteur de pression relative et absolue

Electronic Pressure Switch Type MEP

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

INTERNATIONAL STANDARD

Smart Power Relay E I...

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

PROPORTIONAL PRESSURE CONTROLS TECNORD

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Electrohydraulic Actuator Type PVEP / PVEP-F

Relative and absolute pressure transmitter type 528

High-quality pressure transmitter For general industrial applications Model S-20

SALES SERVICE +358 (0)

Relative and absolute pressure transmitter type 528

Pressure Transmitter SIL

T40FH. Torque flange. Special features. Data sheet

Multifunctional counter tico 772/773/774

2/2 way Proportional Valve (motordriven)

POINTAX 6000L2 Point Recorder

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

KINAX SR 719 Programmable Transmitter for Position Feedback

Speed sensors for general applications:

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Amplifier / controller electronics

Proportional amplifier type EV22K5

ValveExpert. Check / Adjust / Repair Servo- and Proportional Valves. Automatic Test Stand

Subject to changes 11/2003 Page 1/7

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Box chopper amplifier BOE

SOLENOID VALVES LC1AZ - LC1DZ. Solenoid operated directional valves. Size: NG6 ISO CETOP RP121 H-03 (CETOP 3)

4/3-way fast response valve Type 4WRGE

T22. Torque transducer. Special features. Data sheet

Disc Gap Control DGC-2. Technical Manual

ISOMETER IRDH575. Approvals

PHOENIX CONTACT - 09/2009

Flush pressure transmitter For viscous and solids-containing media Model S-11

Technical Documentation

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Electronic Circuit Breaker ESS20-0..

Standard valves to ISO Product range overview

INLINE flowmeter for continuous flow measurement

Technote. Actuator Frese OPTIMA. Application. Features actuator DN15-DN32. Features actuator DN40-DN50. Approval.

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

DIN (NFPA/ISO/CETOP) NG6 (03) NG10

INSERTION paddle wheel flowmeter for continuous flow measurement

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

M-2111 Series Ultrasonic Flow Meter

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

OPTITEMP TT 20 Technical Datasheet

Technical Data. General specifications. Rated operating distance s n 3 mm

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Transcription:

Catalogue HY11-500/UK Characteristics The direct operated control valve D1FP of the nominal size NG0 (CETOP 0) shows extremly high dynamics combined with maximum flow. It is the preferred choice for highest accuracy in positioning of hydraulic axis and controlling of pressure and velocity. Driven by the patented VCD actuator the D1FP reaches the frequency response of real servovalves. Compared with solenoid driven valves the D1FP can also be used in applications with pressure drops up to 50 bar across the valve. Because of the high flow capability the D1FP can be a substitute for NG10 valves in some cases. At power-down the spool moves in a defined position. All common input signals are available. Technical features Real servovalve dynamics (- db / 50 Hz at ±5 % input signal) No flow limit up to 50 bar pressure drop through the valve Max. tank pressure 50 bar (with external drain port y) High flow Defined spool positioning at power-down - optional P-A/B-T or P-B/A-T or center position (for overlapped spools) Onboard electronics D1FP UK.indd RH 0.11.2014-78

Catalogue HY11-500/UK Ordering D 1 F P 9 0 Directional control valve Size DIN NG0 CETOP 0 NFPA D0 Proportional control VCD Spool type Spool position on power down 1) Y-port (plugged) 5) Seals Command signal Accessories Spool/ sleeve design Design series (not required for ordering) E50M E50H E50G E50F E50C E50B B0M B0H B0G B0F B0C E55M E55H E55G E55F E55C E55B E01M E01H E01G E01F E01C E01B B1M B1H B1G B1F B1C E02M E02H E02G E02F E02C E02B B2M B2H B2G B2F B2C Flow [l/min] Spool type at p 5 bar per metering edge Zerolap 1 / 20 Q B = Q A /2 /.5 1 / 8 / / Underlap approx. -0.5 % 1 Overlap % 1 / 20 Q B = Q A /2 /.5 1 / 8 / / 1 / 20 Q B = Q A /2 /.5 1 / 8 / / Connection type 0 + PE acc. EN175201-804 5 11 + PE acc. EN175201-804 7 + PE + Enable Signal Function B +/- 10 V 0...+10 V -> P-A E S A 2) B 2) C ) +/- 20 ma 0...+20 ma -> P-A 4...20 ma...20 ma -> P-A N V H A Seals NBR FPM for HFC fluid Spool position at power down B H 4) a 0 b P A T B J 4) a 0 b P T Note: Adapter plate for ISO 41 to ISO 1072 size 04, Ordering code HAP04WV0-11 Please order connector separately, see chapter accessories. Parametrizing cable OBE -> RS22, item no. 98292 1) On power down the spool moves in a defined position. This cannot be guaranteed in case of single flow path on the control edge A T resp. B T with pressure drops above 0 bar or contamination in the hydraulic fluid. 2) Approx. 10 % opening, only zero lapped spools and underlap spools. ) Only for overlapped spools. 4) Not for flow code M ( l/min). 5) Needs to be removed at tank pressure >5 bar. D1FP UK.indd RH 0.11.2014-79

Catalogue HY11-500/UK Technical Data General Design Direct operated proportional DC valve Actuation VCD actuator Size NG0 / CETOP 0 / NFPA D0 Mounting interface DIN 24 / ISO 41 / CETOP RP1 / NFPA Mounting position unrestricted Ambient temperature [ C] -20...+50 MTTF D value 1) [years] 150 Weight [kg] 5.0 Vibration resistance [g] 10 Sinus 5...2000 Hz acc. IEC 8-2- 0 Random noise 20...2000 Hz acc. IEC 8-2- 15 Shock acc. IEC 8-2-27 Hydraulic Max. operating pressure [bar] Ports P, A, B 50, port T 5 for internal drain, 50 for external drain, port Y 5 2) Fluid Hydraulic oil according to DIN 51524... 55, other on request Fluid temperature [ C] -20...+0 (NBR: -...+0) Viscosity permitted recommended [cst]/mm 2 /s] [cst]/mm 2 /s] 20...0 0...80 Filtration ISO 4 (1999); 18/1/1 Nominal flow at p=5 bar per control edge ) [l/min] / / / 1 / / Flow maximum [l/min] 90 (at p=50 bar over two control edges) Leakage at 100 bar [ml/min] <0 (zerolap spool); <50 (overlap spool) Static / Dynamic Step response at 100 % step 4) [ms] <.5 Frequency response (±5 % signal) 4) [Hz] 50 (amplitude ratio - db), 50 (phase lag -90 ) Hysteresis [%] <0.05 Sensitivity [%] <0.0 Temperature drift [%/K] <0.0 Electrical characteristics Duty ratio [%] 100 Protection class IP5 in accordance with EN 0529 (with correctly mounted plug-in connector) Supply voltage/ripple [V] DC 22... 0, electric shut-off at < 19, ripple < 5 % eff., surge free Current consumption max. [A].5 Pre-fusing [A] 4.0 medium lag Input signal Voltage Impedance Current Impedance Current Impedance [V] [kohm] [ma] [Ohm] [ma] [Ohm] 10...0...-10, ripple <0.01 % eff., surge free, 0...+10 V P->A 100 20...0...-20, ripple <0.01 % eff., surge free, 0...+20 ma P->A 0 4...20, ripple <0.01 % eff., surge free,...20 ma P->A <. ma = disable, >.8 ma = according to NAMUR NE4 0 Differential input max. 0 5 7 Enable signal (only code 5/7) Diagnostic signal [V] 0 for terminal D and E against PE (terminal G) [V] 0 for terminal 4 and 5 against PE (terminal W ) [V] 0 for terminal D and E against PE (terminal G) [V] 5...0, Ri = 9 kohm [V] +10...0...-10 / +.5 error detection, rated max. 5 ma EMC EN 1000--2, EN 1000--4 Electrical connection 0/7 + PE acc. EN 175201-804 5 11 + PE acc. EN 175201-804 Wiring min. 0/7 5 [mm²] [mm²] 7x1.0 (AWG 1) overall braid shield 8x1.0 (AWG 1) overall braid shield Wiring lenght max. [m] 50 1) If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve electronics voltage supply is to be switched off by a suitable switching element with sufficient reliability. 2) For applications with p T >5 bar (max. 50 bar) the Y-port has to be connected and the plug in the Y-port has to be removed. ) Flow rate for different p per control edge: Q x = Q Nom. p x 4) Measured with load (100 bar pressure drop/two control edges). p Nom. D1FP UK.indd RH 0.11.2014-80

Catalogue HY11-500/UK Characteristic Curves Flow curves at Dp = 5 bar per metering edge Spool type E01/E50 Spool type B0 100%=Q Nom. A-T P-A Flow 50% P-B B-T 0% -100% 0% Command signal 100% Pressure gain Functional limits at %, 50 %, 75 % and 100 % command signal Spool type E50M Frequency response ±5 % command signal ±90 % command signal All characteristic curves measured with HLP4 at 50 C. D1FP UK.indd RH 0.11.2014-81

Catalogue HY11-500/UK Block Diagrams 0 5 + PE 11 + PE 7 + PE + Enable D1FP UK.indd RH 0.11.2014-82

Catalogue HY11-500/UK Interface Program ProPxD interface program The ProPxD software allows quick and easy setting of the digital valve electronics. Individual parameters as well as complete settings can be viewed, changed and saved via the comfortable user interface. Parameter sets saved in the non-volatile memory can be loaded to other valves of the same type or printed out for documentation purposes. The PC software can be downloaded free of charge at www.parker.com/euro_hcd see page Support. Features Comfortable editing of valve parameters Saving and loading of customized parameter sets Executable with all Windows operating systems from Windows XP upwards Simple communication between PC and valve electronics via serial interface RS22 The valve electronics cannot be connected to a PC with a standard USB cable this can result in damages of PC and/or valve electronics. The parametrizing cable may be ordered under item no. 98292. D1FP UK.indd RH 0.11.2014-8

Catalogue HY11-500/UK Dimensions Surface finish BK75 4x M5x0 ISO 472-.9 7. Nm ±15 % NBR: SK-D1FP FPM: SK-D1FP-V HFC: SK-D1FP-H D1FP UK.indd RH 0.11.2014-84