Analysis of Electromagnetic Transients in Secondary Circuits due to Disconnector Switching in 400 kv Air-Insulated Substation

PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS

VFTO STUDIES DUO TO THE SWITCHING OPERATION IN GIS 132KV SUBSTATION AND EFFECTIVE FACTORS IN REDUCING THESE OVER VOLTAGES

Lightning Overvoltage Performance of 110 kv Air-Insulated Substation

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

Electromagnetic Disturbances of the Secondary Circuits in Gas Insulated Substation due to Disconnector Switching

Ferroresonance Experience in UK: Simulations and Measurements

Modeling for the Calculation of Overvoltages Stressing the Electronic Equipment of High Voltage Substations due to Lightning

EXPERIMENTAL INVESTIGATION OF A TRANSIENT INDUCED VOLTAGE TO AN OVERHEAD CONTROL CABLE FROM A GROUNDING CIRCUIT

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS

A Study on Ferroresonance Mitigation Techniques for Power Transformer

Effect of Shielded Distribution Cables on Lightning-Induced Overvoltages in a Distribution System

Accurate Modeling of Core-Type Distribution Transformers for Electromagnetic Transient Studies

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

Identification of Parameters for Coupling Capacitor Voltage Transformers

A Special Ferro-resonance Phenomena on 3-phase 66kV VT-generation of 20Hz zero sequence continuous voltage

GIS Disconnector Switching Operation VFTO Study

Effect of High Frequency Cable Attenuation on Lightning-Induced Overvoltages at Transformers

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

High frequency transformer model for calculations of transferred overvoltages. I. UGLESIC University of Zagreb, Croatia

Research Article Survey of Induced Voltage and Current Phenomena in GIS Substation

Analyzing and Modeling the Lightning Transient Effects of 400 KV Single Circuit Transmission Lines

Session Four: Practical Insulation Co-ordination for Lightning Induced Overvoltages

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers

The relationship between operating maintenance and lightning overvoltage in distribution networks based on PSCAD/EMTDC

GIS Instrument Transformers: EMC Conformity Tests for a Reliable Operation in an Upgraded Substation

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

Power Quality and Reliablity Centre

Parameters Affecting the Back Flashover across the Overhead Transmission Line Insulator Caused by Lightning

Relay Protection of EHV Shunt Reactors Based on the Traveling Wave Principle

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500 kv Substation

Modeling and Analysis of a 3-Phase 132kv Gas Insulated Substation

University of Zagreb Faculty of Electrical Engineering and Computing

DIFFERENCE BETWEEN SWITCHING OF MOTORS & GENERATORS WITH VACUUM TECHNOLOGY

Software Development for Direct Lightning Stroke Shielding of Substations

A Simple Simulation Model for Analyzing Very Fast Transient Overvoltage in Gas Insulated Switchgear

G. KOEPPL Koeppl Power Experts Switzerland

Lightning transient analysis in wind turbine blades

2000 Mathematics Subject Classification: 68Uxx/Subject Classification for Computer Science. 281, 242.2

Experimental Investigations and Calculations in 6-35 kv Networks with Various Neutral Conditions

Distance Protection of Cross-Bonded Transmission Cable-Systems

Experimental Study and Circuit Analysis Model of Lightning Isolation Transformer for Railway Signal System

Measurements for validation of high voltage underground cable modelling

Fast Front Transients in Transformer Connected to Gas Insulated Substations: (White+Black) Box Models and TDSF Monitoring

Transient recovery voltage analysis for various current breaking mathematical models: shunt reactor and capacitor bank de-energization study

MODERN COMPUTATIONAL METHODS FOR THE DESIGN AND ANALYSIS OF POWER SYSTEM GROUNDING

Effect of Shielded Distribution Cable on Very Fast Transients

LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION

Research on State Estimation and Information Processing Method for Intelligent Substation

Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP

X International Symposium on Lightning Protection

Resonances in Collection Grids of Offshore Wind Farms

A MODEL TO SIMULATE EM SWITCHING TRANSIENTS IN ELECTRIC POWER DISTRIBUTION SUBSTATIONS

A Pyrotechnic Fault Current Limiter Model for Transient Calculations in Industrial Power Systems

AORC Technical meeting 2014

Operation Analysis of Current Transformer with Transient Performance Analysis Using EMTP Software

Electromagnetic Interference in the Substation Jose up 400/115 kv

Electrical Power and Energy Systems

Modeling insulation in high-voltage substations

Končar TMS - Bushing monitoring

Analysis of a 405 km transmission line with series compensation

Single Line Diagram of Substations

Insulation Co-ordination For HVDC Station

Lightning current field measurement on a transmission line, comparison with electromagnetic transient calculations

Maximum Lightning Overvoltage along a Cable due to Shielding Failure

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

ELECTRICAL POWER ENGINEERING

A3-102 PCB ROGOWSKI COILS HIGH PRECISION LOW POWER SENSORS. Ljubomir A. Kojovic * Cooper Power Systems USA

Research Article A Simplified High Frequency Model of Interleaved Transformer Winding

SUPPRESSION METHODS FOR VERY FAST TRANSIENT OVER- VOLTAGES ON EQUIPMENT OF GIS

VI 3 - i TABLE OF CONTENTS

A Simulator for Calculating Normal Induced Voltage on Communication Line

Calculation of Transients at Different Distances in a Single Phase 220KV Gas insulated Substation

Investigation into Transient SFO, FFO, VFTO Overvoltage Characteristics for Typical Gas Insulated Substations

Novità sulla IEC ; -10; -12

Simulation of Lightning Transients on 110 kv overhead-cable transmission line using ATP-EMTP

THE EFFECT OF VARIOUS PARAMETERS OF CVT ON ITS PERFORMANCE, AND THEIR ROLE ON POWER QUALITY

Simulation of Short Circuit and Lightning Transients on 110 kv Overhead and Cable Transmission Lines Using ATP-EMTP

Electrical Transient Interaction between Transformers and Power System. Brazilian Experience

The various factors influencing the VFTO levels in 500kV and. 750kV GIS have been discussed by developing the simulink models which

EXPERIMENTAL ISSUES OF OVERVOLTAGE COORDINATION

ELECTRICAL POWER TRANSMISSION TRAINER

N. TEST TEST DESCRIPTION

High voltage engineering

Modeling Ferroresonance Phenomena on Voltage Transformer (VT)

Cable Solutions for Servo and Variable Frequency Drives (VFD)

ATP SIMULATION OF FARADAY CAGE FOR THE ANALYSIS OF LIGHTNING SURGES

Published in: Proceedings of the International Conference on Power Systems Transients (IPST 2009)

CASE STUDY ON TRANSFORMER MODELS FOR CALCULATION OF HIGH FREQUENCY TRANSMITTED OVERVOLTAGES

ScienceDirect. Simulation Models for Various Neutral Earthing Methods in Medium Voltage Systems

IEC Electrical fast transient / Burst immunity test

MV network design & devices selection EXERCISE BOOK

Revision of TRV Requirements for the Application of Generator Circuit-Breakers

LIMITS FOR TEMPORARY OVERVOLTAGES IN ENGLAND AND WALES NETWORK

Tab 2 Voltage Stresses Switching Transients

Reducing the magnetizing inrush current by means of controlled energization and de-energization of large power transformers

Comparison of Measured Transient Overvoltages in the Collection Grid of Nysted Offshore Wind Farm with EMT Simulations

Transcription:

This is the author s version of a work that was submitted/accepted for publication in the Special issue of Electric Power Systems Research journal based on selected expanded contributions from the 10 th International Conference on Power System Transients (IPST) in the following source: B. Filipović-Grčić, I. Uglešić,. Milardić, D. Filipović-Grčić, Analysis of electromagnetic transients in secondary circuits due to disconnector switching in 400 k air-insulated substation, Electric Power Systems Research, olume 115, October 2014, Pages 11-17, ISSN 0378-7796, http://dx.doi.org/10.1016/j.epsr.2014.02.004. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Electric Power Systems Research, [ol. 115, 2014]. Copyright 2014 Elsevier S.A. Notice: Changes introduced as a result of publishing processes such as copy-editing, formatting and technical enhancement may not be reflected in this document. For a final version of this work, please refer to the published source: http://dx.doi.org/10.1016/j.epsr.2014.02.004 URL: http://www.sciencedirect.com/science/article/pii/s0378779614000418

Analysis of Electromagnetic Transients in Secondary Circuits due to Disconnector Switching in 400 k Air-Insulated Substation B. Filipović-Grčić a, *, I. Uglešić a,. Milardić a, D. Filipović-Grčić b Abstract-- This paper describes the electromagnetic transients caused by disconnector switching in 400 k air-insulated substation. Transient overvoltages in the secondary circuits of capacitor voltage transformer (CT) have been calculated using the EMTP-ATP software. The transfer of electromagnetic transients through substation s grounding grid has been analyzed in order to determine the overvoltages at the terminals of protective relays located in the control (relay) room. The overvoltages in secondary circuits have been recorded during onsite test. galvanic connection between the grounding system and the secondary circuits (Fig. 2). High-frequency transient current flowing in the grounding system generates potential differences every time when a strike occurs between the disconnector's contacts. Keywords: disconnector switching, electromagnetic transients, secondary circuits, capacitor voltage transformer, transferred overvoltages. 1. Introduction Secondary equipment in H substation is highly sensitive to transient electromagnetic disturbances due to the disconnector switching operations. Opening and closing of the disconnector produce electromagnetic transients with a very fast rate of rise. These transients can be particularly harmful to microprocessor-based electronic equipment located near the H switching devices [1], [2]. H disconnectors have a negligible current interrupting capability ( 0.5 A) which includes the capacitive charging currents of bushing, busbars, connective leads, very short lengths of cables and of the CT [3]. Literature [4] [6] related to capacitive current interruption by air-break disconnectors is sparse and a good overview is presented in [7]. A disconnector operates only after a circuit-breaker has already opened the corresponding switchyard section, which represents a capacitive load. When the slow moving contacts of a disconnector close or open, numerous pre-strikes or re-strikes occur between the contacts (Fig. 1). These high-frequency phenomena are coupled with the secondary circuits as a result of various mechanisms [8]-[11]. Electromagnetic disturbances are transmitted to secondary circuits through stray capacitances between the high-voltage conductors and the grounding system, followed by the a* Corresponding author: B. Filipović-Grčić (e-mail: bozidar.filipovicgrcic@fer.hr) is with the Faculty of Electrical Engineering and Computing, University of Zagreb, 10000 Zagreb, Croatia, tel.: +385 1 6129 714; fax: +385 1 6129 890. a I. Uglešić and. Milardić are with are with the Faculty of Electrical Engineering and Computing, University of Zagreb, 10000 Zagreb, Croatia (email addresses: ivo.uglesic@fer.hr, viktor.milardic@fer.hr). b D. Filipović-Grčić is with Končar Electrical Engineering Institute, 10000 Zagreb, Croatia (e-mail: dfilipovic@koncar-institut.hr).n ancouver, Canada July 18 Fig. 1. oltages associated with disconnector switching: (a) simple scheme of a substation; (b) voltage waveform on disconnector due to opening of the contacts Fig. 2. Coupling mechanisms between H and L circuit In case of large secondary circuits, the potential differences are in the form of longitudinal voltages between the terminal and the enclosure of the equipment. Depending on the type of secondary circuits and the way they are laid, differential voltages may also occur. Such a coupling mechanism has a special effect on the secondary circuits of instrument transformers, and particularly on the connected instruments, since these circuits are always directly connected to the grounding system. Another important factor which also has to be taken into account is the linking of these circuits through

I U I the internal capacitances of the instrument transformers. This paper deals with transient overvoltages in the secondary circuits of CT due to disconnector switching in 400 k air-insulated substation. The transferred overvoltages in the secondary circuits were estimated in the designing process of high voltage substation. Recorded transients caused by disconnector switching in 400 k substation are presented. control/relay room. Fig. 4 shows the configuration of substation grounding grid between CT and the relay/control room. Capacitor voltage transformer 2. Modeling of 400 k substation Fig. 3 shows a part of 400 k substation used for the analysis of the disconnector switching. Transmission line 400 k auxiliary busbars 40 m Capacitor voltage transformer Disconnector Grounding grid Auxiliary busbars 400 k Control/relay room Control/relay room RK15A Main busbars 400 k Fig. 4. Substation grounding grid between CT and the control/relay room RK15A =C1 =C8 Switching the transmission line bay from the main to the auxiliary busbar system and vice versa was analyzed. In this case the CT and the auxiliary busbars represent capacitive 344 load which is switched by the disconnector in line bay. The 18 m transfer of electromagnetic transients through the substation s grounding grid has been analyzed in order to determine the overvoltages at the terminals of protective relays located in the D elebit Fig. 3. A part of 400 k substation used for the analysis of the disconnector 324.6 switching 324.6 65.3 m 42 m Network equivalent Cr Capacitance to ground of disconnector Disconnector Otpor luka Arc resistance C1=4.7 nf Auxiliary busbars 9.5 m 12 m 300 6 m CC=600 pf Cr Cc=600 pf Capacitance 150 to ground m of Capacitance to bus support insulators ground of closed LC=50.7 H RC=500 Ω Lc Rc disconnector 50.7 H 500 Connection to grounding grid 150 m Fig. 5. EMTP-ATP model for analysis of disconnector switching The model for the analysis of the disconnector switching in EMTP/ATP software is shown in Fig. 5. CT in one phase was represented with the following elements [12], [13]: two 324.6 capacitors 111.2 m C 1 and C 2 connected in series on the H side; compensating inductor (R C, L C, C C ); step-down transformer (primary winding R P, L P, C P ; secondary winding R S, L S, C S ); stray capacitance between primary and secondary windings C PS ; burden 4.6 A (726 Ω). Stray capacitance between primary and secondary windings has a significant influence on the transient response of the CT for frequencies above 10 khz (Fig. 6). C2=72.45 nf 0.001 C1=4.7 nf U U C2=72.45 nf Cp=600 pf Cps pf Capacitor voltage transformer Rp Lp Ls Rs CPS=100 pf 296 1 mω 6.5 H LP=6.5 H 1 mh 1 m RP=296 Ω LS=1 mh RS=1 mω Segment 1: 9 m CP=600 pf Nap.trafo 15k 0.1/ P n: 1 S Segment 2: 2 m Rb=726 Ω 100 CS=100 pf Cs=100 pf 150 m

I 0.005 km 0.005 km 0.005 km 0.005 km 0.005 km 0.005 km 0.005 km 0.005 km 0.005 km 0.005 km 0.005 km 0.005 km 0.005 km 0.013 km 0.003 km 0.003 km 0.003 km 0.003 km 0.003 km 0.01 km The electrical and geometrical parameters of the auxiliary busbar system are shown in Table 2. Table 2 ELECTRICAL AND GEOMETRICAL PARAMETERS OF AUXILIARY BUSBAR R in (cm) R out (cm) DC resistance (mω/km) SYSTEM Height above ground (m) Length (m) Spacing between phases (m) 10.2 11 6.285 12.66 171.4 6 Fig. 6. Influence of stray capacitance C PS between primary and secondary windings on CT transfer function frequency response (calculated in EMTP) The grounding mesh has been represented with the frequency dependent cable model (Fig. 7). The mutual coupling between grounding system components has been taken into account by treating them as different phases of a cable. 0.011 km Connection of CT to grounding grid 0.011 km The auxiliary busbar system was modeled with the frequency dependent JMarti model [14] and bus support insulators with capacitances to the ground [15]. The equivalent network from the source side of the disconnector has been represented by a voltage source and a short-circuit impedances. Arc resistance of 2 Ω between the disconnector's contacts was assumed in simulations. 3. Calculation of overvoltages in secondary circuits due to the disconnector switching A flashover in case of 2 p.u. voltage between opening contacts of disconnector as the worst theoretical case has been analyzed. In a real operation the flashover occurs at lower voltage differences and the corresponding overvoltages are lower. Figs. 8-12 show the calculation results in case of disconnector opening. When closing the disconnector the flashover was simulated at the voltage difference of 1 p.u. between the contacts. 0.01 km 0.006 km 0.007 km 0.006 km 0.004 km 0.004 km 0.007 km 0.003 km 0.007 km 0.003 km 0.006 km Fig. 8. Overvoltage on H side of CT 0.004 km 0.004 km Fig. 7. A small part of substation grounding grid modeled in EMTP-ATP The relay room RK15A is located 40 m away from CT. The parameters of the grounding system are shown in Table 1. Table 1 PARAMETERS OF THE GROUNDING SYSTEM IN 400 K SUBSTATION Material Copper wire Specific resistance (Ωmm 2 /m) 0.0169 Cross section (mm 2 ) 120 Soil resistivity ( m) 300 Burial depth (m) 0.8 Fig. 9. Overvoltage on L side of CT

with the decrease of CT secondary burden. Fig. 13 shows the transferred overvoltage on CT secondary for burden 1 A in case of disconnector opening. The influence of CT secondary burden on the transferred overvoltage amplitudes is shown in Table 4. This analyzed example represents the worst case scenario. In order to reduce the longitudinal voltage caused by high frequency transients, shielding and multiple grounding of secondary circuits are necessary. Fig. 10. Current through connection of CT on grounding grid Fig. 11. Grounding potential on CT connection to grounding grid Fig. 12. Grounding potential in relay/control room RK15A The calculated overvoltage amplitudes in case of disconnector opening and closing are shown in Table 3. Table 3 CALCULATION RESULTS Fig. 13. Overvoltage on L side of CT in case of disconnector opening - burden 1 A Table 4 INFLUENCE OF BURDEN ON OEROLTAGE AMPLITUDES TRANSFERRED TO L SIDE OF CT CT secondary burden Disconnector closing Disconnector opening 1 A 788.5 1577.1 2.5 A 553.8 1067.5 4.6 A 376.4 752.9 By applying the previously described approach it is possible to estimate the overvoltage amplitudes in secondary circuits in the designing process of high voltage substation. 4. Disconnector switching in 400 k substation on-site testing On-site test circuit for measurement of transients caused by disconnector switching in 400 k substation is shown in Fig. 14. Disconnector switching operation Closing Opening U max on H side of CT 656.1 k 985.6 k U max on L side of CT 376.4 752.9 Impulse current I max on CT connection to grounding grid 691.1 A 1382.2 A Grounding potential on CT connection to grounding grid 719.7 1438.5 Grounding potential in the relay/control room RK15A 150.7 300.4 GS2 =C1 Q21 GS1 2 Q11 Q2L3 Q1L3 T25L3 T15L3 DSO Overvoltages on secondary side of CT are lower than 1.6 k which is the highest permissible value [16]. High frequency disturbances that occur in secondary circuits could disturb the normal operations of microprocessor-based electronic equipment. The transferred overvoltages increase -T1 Q0 -T2 RK403 Fig. 14. On-site test circuit for measurement of transients caused by disconnector switching

Switching of CT T25L3 on main busbars has been performed with disconnector Q2L3. CT secondary is connected to the equipment in the relay room with 66 m long measuring cable. The measurements of overvoltages in secondary circuits have been conducted in the relay/control room RK403 with digital storage oscilloscope (DSO), 500 MHz, 1 GS/s. Transients due to disconnector opening and closing have been recorded. Numerous flashovers between disconnector contacts (21 recorded) cause high frequency overvoltages on grounded cable sheath. 4.1. Disconnector closing Figs. 15-16 show overvoltages at the end of the measuring cable in the relay room due to disconnector closing. Fig. 18. Overvoltage caused by single flashover marked red on Fig. 17 4.2. Disconnector opening Figs. 19-20 show overvoltages at the end of the measuring cable in the relay room due to disconnector opening. Fig. 15. Overvoltages at the end of the measuring cable in the relay room due to disconnector closing Fig. 16. Overvoltage caused by single flashover marked red in Fig. 15 Fig. Fig. 19. Overvoltages 19. Overvoltages at the at end the end of the of measuring the measuring cable cable in the in relay the relay room rodue to disconnector opening Figs. 17-18 show overvoltages on grounded cable sheath due to disconnector closing. Fig. 20. Overvoltage caused by single flashover marked red in Fig. 19 Fig. 17. Overvoltages on grounded cable sheath due to disconnector closing Figs. 21-22 show overvoltages on grounded cable sheath due to disconnector opening. Measured overvoltage amplitudes in secondary circuits are lower than 200, which is well below permissible value of 1.6 k. The dominant frequency of overvoltages is around 350 khz.

Fig. 21. Overvoltages on grounded cable sheath due to disconnector opening Fig. 22. Overvoltage caused by single flashover marked red in Fig. 21 5. Conclusion The opening and closing of the disconnector produce electromagnetic transients with a very fast rate of rise, which in some cases could be particularly harmful to secondary equipment located near the H switching devices. Special attention should be paid to overvoltages transferred to the secondary circuits. The transferred transients in the secondary circuits have been estimated in the designing process of high voltage substation. The transfer of electromagnetic transients through substation s grounding grid has been analyzed in order to determine the overvoltages at the terminals of protective relays located in the control/relay room. Peak values of transferred overvoltages increase as secondary burden decreases. Stray capacitance between CT primary and secondary windings has significant influence on the transient response at high frequencies. This parameter is of primary importance in the frequency range of 10 khz 1 MHz. On-site tests performed in test operation of a real substation have demonstrated that the amplitudes of measured transferred overvoltages were not critical in the case of disconnector switching the CT. References [1] S. Carsimamovic, Z. Bajramovic, M. Ljevak, M. eledar, N. Halilhodzic, Current Switching with High oltage Air Disconnector, International Conference on Power Systems Transients, Montreal, Canada, June 19-23, 2005. [2] Y. Sang-Min, K. Chul-Hwan, S. Hun-Chul, L. Young-Sik, C. Burm-Sup, EMTP Analysis of ery Fast Transients due to Disconnector Switching in a 345 k Korean Thermal Plant, The International Conference on Electrical Engineering, Hong Kong, July, 2008. [3] IEC 62271-102 High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches First edition, 2001. [4] S. Yinbiao, H. Bin, L. Ji-Ming, C. Weijiang, B. Liangeng, X. Zutao, C. Guoqiang Influence of the Switching Speed of the Disconnector on ery Fast Transient Overvoltage, IEEE Transactions on Power Delivery, ol. 28, No. 4, April 2013. [5] Y. Chai, P. A. A. F. Wouters, R. T. W. J. van Hoppe, R. P. P. Smeets, D. F. Peelo, Capacitive Current Interruption With Air-Break High oltage Disconnectors, IEEE Transactions on Power Delivery, ol. 25, No. 2, April 2010. [6] Y. Chai, P. A. A. F. Wouters, R. P. P. Smeets, Capacitive Current Interruption by H Air-Break Disconnectors With High-elocity Opening Auxiliary Contacts, IEEE Transactions on Power Delivery, ol. 26, No. 4, October 2011. [7] D. F. Peelo, Current interruption using high voltage air-break disconnectors, Ph.D. dissertation, Dept. Elect. Eng., Eindhoven Univ. Technol., Eindhoven, The Netherlands, 2004. [8] H. Heydari,. Abbasi, F. Faghihi, Impact of Switching-Induced Electromagnetic Interference on Low-oltage Cables in Substations, IEEE Transactions on Electromagnetic Compatibility, ol. 51, No. 4, November 2009. [9] P. H. Pretorius, A. C. Britten, J. M. an Coller, J. P. Reynders, Evaluation of the coupling mechanisms of electromagnetic disturbances resulting from disconnector switching in substations: experimental design and initial results, Proceedings of the South African Symposium on Communications and Signal Processing, pp. 315-318, September 1998. [10] A. Ametani, N. Taki, D. Miyazaki, N. Nagaoka, S. Okabe, Lightning surges on a control cable incoming through a grounding lead, IEE Japan Transactions on Power and Energy, ol. 127, No. 1, pp. 267-275, January 2007. [11] A. Ametani, T. Goto, N. Nagaoka, H. Omura, Induced surge characteristics on a control cable in a gas-insulated substation due to switching operation, IEE Japan Transactions on Power and Energy, ol. 127, No. 1, pp. 1306-1312, December 2007. [12] M. Kezunovic, Lj. Kojovic,. Skendzic, C. W. Fromen, D. R. Sevcik, S. L. Nilsson, Digital models of coupling capacitor voltage transformers for protective relay transient studies, IEEE Transactions on Power Delivery, ol. 7, No. 4, October 1992. [13] D. Fernandes Jr., W. L. A. Neves, J. C. A. asconcelos, Coupling capacitor voltage transformer: A model for electromagnetic transient studies, Electric Power Systems Research, ol. 77, No. 2, pp. 125-134, February 2007. [14] L. Prikler, H. K. Høidalen, ATP Draw User s Manual, SEfAS TR A4790, ISBN 82-594-1358-2, Oct. 1998. [15] Ali F. Imece, D. W. Durbak, H. Elahi, S. Kolluri, A. Lux, D. Mader, T. E. McDemott, A. Morched, A. M. Mousa, R. Natarajan, L. Rugeles, and E. Tarasiewicz, Modeling guidelines for fast front transients, Report prepared by the Fast Front Transients Task Force of the IEEE Modeling and Analysis of System Transients Working Group, IEEE Transactions on Power Delivery, ol. 11, No. 1, January 1996. [16] IEC 61869-1 Instrument transformers - Part 1: General requirements, 2007.

Božidar Filipović-Grčić was born in Sinj, Croatia, in 1983. He received the B.Sc. and Ph.D. degrees from the Faculty of Electrical Engineering and Computing, University of Zagreb, in 2007 and 2013, respectively. Currently he is working at the Faculty of Electrical Engineering and Computing (Department of Energy and Power Systems). He is the head of quality in the High oltage Laboratory at the Faculty of Electrical Engineering and Computing. His areas of interest include power system transients, insulation co-ordination and high-voltage engineering. He is a member of the IEEE society and CIGRÉ Study Committee A3 - High voltage equipment. iktor Milardić was born in 1971. He received the B.Eng., the M.Eng. and Ph.D. degrees in electrical engineering from the University of Zagreb, Croatia in 1995, 2001 and 2005 respectively. He has three years of working experience in the Distribution of Electrical Energy. Currently he is an associate professor at the Department of Energy and Power Systems at the Faculty of Electrical Engineering and Computing, University of Zagreb. His main topics of research are surge protection, lightning protection, grounding, electromagnetic compatibility and H laboratory testing. Mr. Milardić is a member of IEEE society and Chairman of SC C4 Croatian Committee of Cigré. Ivo Uglešić was born in Zagreb, Croatia, in 1952. He received the Ph.D. degree from the Faculty of Electrical Engineering and Computing, University of Zagreb, Croatia, in 1988. Currently he is a Professor at the Faculty of Electrical Engineering and Computing (Department of Energy and Power Systems), University of Zagreb. Professor Uglešić is the head of the High-oltage Laboratory at the Faculty of Electrical Engineering and Computing. His areas of interest include high-voltage engineering and power transmission. Dalibor Filipović-Grčić was born in Sinj, Croatia, in 1980. He received his Ph.D. from the Faculty of Electrical Engineering and Computing, University of Zagreb, in 2010. Currently he is the head of the High-oltage Laboratory at the Končar Electrical Engineering Institute, Transformer Department. His areas of interest include high-voltage test and measuring techniques, instrument and power transformers, insulation systems optimization. He is a member of the technical committees TC E 38 Instrument Transformers and TC E 42 High voltage test techniques.