U90xxA X-Series Measurement Applications for the EXT Wireless Communications Test Set

Similar documents
1xEV-DO X-Series Measurement Application N9076A & W9076A

N9051A Pulse Measurement Software

cdma2000 X-Series Measurement Application N9072A & W9072A

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Keysight Technologies Overcoming LTE-A RF Test Challenges. Application Note

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Keysight Technologies M9076A 1xEV-DO

Agilent First-generation MXG Signal Generators

Agilent N9310A RF Signal Generator. All the capability and reliability of an Agilent instrument you need at a price you ve always wanted

Key Features B/BN-B7X TD-SCDMA Modulation Analysis 89600B Vector Signal Analysis Software. Technical Overview

EXT Wireless Communications Test Set E6607B. Data Sheet

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

From 2G to 4G UE Measurements from GSM to LTE. David Hall RF Product Manager

Agilent MXG Signal Generators

Keysight Technologies A Flexible Testbed to Evaluate Potential Co-Existence Issues Between Radar and Wireless

When is it Time to Transition to a Higher Bandwidth Oscilloscope?

M9080A & M9082A LTE FDD/TDD. Challenge the Boundaries of Test Agilent Modular Products. Technical Overview

Agilent MXG Signal Generators

Keysight Technologies Z9070B Wideband Signal Analysis Solution. Technical Overview

PXI LTE FDD and LTE TDD Measurement Suites Data Sheet

Educator s Oscilloscope Training Kit for Agilent InfiniiVision X-Series Oscilloscopes

R&S CMW500 Wideband Radio Communication Tester Specifications

VST 6 GHz RF Vector Signal Transceiver (VST)

Keysight Technologies Isolating Problems and Optimizing Wireless Designs with Digital Demodulation and EVM

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent E6651A Mobile WiMAX Test Set

Meet the new E4438C ESG vector signal generator...

Measurement Guide and Programming Examples

Keysight Technologies Test Case Manager N7649B

89601B/BN-B7U W-CDMA/HSPA+ Modulation Analysis 89600B Vector Signal Analysis Software. Key Features. Technical Overview

MXG X-Series Signal Generator N5183B Microwave Analog

VIAVI VST. Data Sheet. 6 GHz RF Vector Signal Transceiver (VST)

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Productivity and flexibility for A/D applications

Agilent Digital Modulation Lab Station

Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Keysight Technologies VSA Software

Agilent N9340B Handheld Spectrum Analyzer (HSA)

MXG Analog Signal Generator Express Configurations

Agilent N7620A Signal Studio for Pulse Building

Agilent N9342C Handheld Spectrum Analyzer (HSA)

R&S CMW100 Communications Manufacturing Test Set Specifications

PXI UMTS Uplink Measurement Suite Data Sheet

Agilent E4428C and E4438C ESG Signal Generators

Keysight Technologies

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

Keysight Technologies N9063A & W9063A Analog Demodulation

Agilent NFA Noise Figure Analyzer

Keysight Technologies 89601B-SSA/89601BN-SSA Spectrum Analysis VSA Software

Agilent N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Keysight X-Series Signal Analyzers

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Keysight Technologies

Keysight Technologies N6141A & W6141A EMI X-Series Measurement Application. Technical Overview

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

PXI. cdma2000/ev-do Measurement Suite Data Sheet. The most important thing we build is trust. cdma2000 RC1 to RC4 reverse link analysis

2012 LitePoint Corp LitePoint, A Teradyne Company. All rights reserved.

R&S CMW100 Communications Manufacturing Test Set Specifications

Agilent E1969A TD-SCDMA_GSM Fast Switch Test Application

PXI. TD-SCDMA Measurement Suite Data Sheet. The most important thing we build is trust. Total Average Power plus Midamble / Data Power

Keysight Technologies N9310A RF Signal Generator

Keysight N9310A RF Signal Generator

Keysight Technologies Phase Noise X-Series Measurement Application

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Keysight W1916 3G Baseband Verification Library

N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Agilent E4428C and E4438C ESG Signal Generators. Confi guration Guide

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Keysight Technologies Understanding the SystemVue To ADS Simulation Bridge. Application Note

Agilent NFA Noise Figure Analyzer

Radar System Design and Interference Analysis Using Agilent SystemVue

Keysight Technologies W-CDMA/HSPA+ X-Series Measurement Application N9073A & W9073A

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Keysight Technologies Signal Studio for cdma2000/1xev-do N7601B

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Agilent E4428C and E4438C ESG Signal Generators

Agilent 8761A/B Microwave Switches

Keysight M9485A PXIe Multiport Vector Network Analyzer


Keysight Technologies Signal Studio for TD-SCDMA/HSDPA N7612B

Practical Digital Pre-Distortion Techniques for PA Linearization in 3GPP LTE

Keysight Technologies Signal Studio for DFS Radar Profiles N7607C

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Introduction. Part 1. Introduction...2

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Essential Capabilities of EMI Receivers. Application Note

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Technologies First-Generation MXG Signal Generators

Keysight Technologies GSM/EDGE/EVO X-Series Measurement Application N9071A & W9071A. Technical Overview

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Keysight Technologies MATLAB Data Analysis Software Packages

Transcription:

U90xxA X-Series Measurement Applications for the EXT Wireless Communications Test Set Leverage the industry-proven Agilent X-Series measurements applications for the EXT wireless communications test set in non-signaling wireless device manufacturing Accelerate test sequences with EXT s powerful and flexible sequencer for fast, multiple measurements from a single acquisition Achieve fast and accurate measurements, optimized for nonsignaling test techniques in high-throughput manufacturing test applications

Introduction Contents Introduction 2 Product Summary 5 Cellular Communications 6 LTE-FDD 6 LTE-TDD 6 GSM/EDGE/Evo 7 W-CDMA/HSPA+ 7 cdma2000 /cdmaone 8 1xEV-DO 8 TD-SCDMA/HSPA 9 Wireless Connectivity 10 Mobile WiMAX 10 Bluetooth 10 General Purpose 11 Analog demodulation 11 Flexible Software Licensing 12 Software licensing and configuration 12 Leveraging the industry-proven expertise in X-Series measurement applications, the Agilent Technologies U90xxA X-Series measurement applications for the EXT wireless communications test set deliver fast and accurate measurements for high-throughput manufacturing applications. The U90xxA inherited the one-button RF conformance measurements from other X-Series applications to help you design, evaluate, and manufacture your devices and equipment, and enable you to stay on the leading edge of your design and manufacturing challenges. The EXT is part of Agilent s comprehensive Power of X Suite of test products and the standard unit includes a source list sequencer and sequence analyzer. The powerful sequence analyzer function provides a host of capabilities to increase speed and throughput in non-signaling manufacturing test. Capabilities include full-featured analysis tools and source synchronization, all designed to match the needs of current and future chipsets. 2 2

U90xxA X-Series Measurement Applications Execute test plans at the chipset s highest achievable speed using the powerful and flexible EXT sequencer Acquisition Analysis intervals (relative to start of acquisition) Rx sequence Acquisition Provides a test solution that is designed for non-signaling, ultra-fast device calibration and verification Works in synch with chipset test modes to eliminate signaling overhead Enables single acquisition with multiple measurements Allows precise control of test intervals, test levels, and measurement timing Provides more flexibility and capability than list mode Performs multi-technology sweeps Pretrigger Trigger event Acquisition duration Transition time Figure 1: A receiver test sequence consisting of two acquisitions, and single acquisition with multiple measurements Measurement Application Signal Studio* Format Sequence analyzer 1-button measurements GSM/EDGE/Evo W-CDMA/HSPA/HSPA+ cdma2000, 1xEV-DO LTE-FDD LTE-TDD 1 X TD-SCDMA 1 X Mobile WiMAX X Bluetooth X Analog demodulation X liustrates which wireless formats have been enabled in the sequence analyzer. *For more information on Signal Studio www.agilent.com/find/signalstudio 1. Contact your Agilent Technologies Sales Representative for more information. Transforming manufacturing test 3 3

U90xxA X-Series Measurement Applications Reduce total cost of ownership With an architecture optimized for low-cost, non-signaling test, the EXT wireless communications test set enables you to keep your test assets current, agile, and scalable for extended instrument longevity. The forward-looking hardware, and software scalability for technology and chipset test-mode advances, preserves your investment and reduces long term costs. The EXT minimizes test times, improves production yields, and minimizes downtime, helping you reduce operating expenses on your production line. Benefit from a consistent measurement framework Realize measurement integrity across your organization with consistent operation and test methods, proven algorithms, applications, and results. Your team can leverage the test system software through all phases of product development, allowing them to move at a faster pace. Whether you run them on the PXA, MXA, EXA, CXA, or EXT, you ll get the same results from the development lab into manufacturing. The only difference is the level of performance achieved by the instrument hardware, so you can choose the level of performance necessary for your application. And with consistent programming commands used across the X-Series, you minimize the effort and cost of creating test systems. A common, familiar user interface means increased efficiency and productivity when you learn how to use one X-Series product, you know how to use them all. Enhance and customize your data analysis power With the open Windows XP operating system, you can create customized demodulation macros and run applications such as MATLAB, which allows you to further analyze and visualize your wireless data, execute and test modulation schemes, and develop automated tests. Try before you buy! Free 14-day trials of X-Series measurement applications are available. www.agilent.com/find/x-series_ext_trial 4 4

Product Summary Cellular communications Technology U90xxA measurement application model number Fixed Perpetual license Transportable LTE-FDD U9080A-1 U9080A-1FP U9080A-1TP LTE-TDD U9082A-1 U9082A-1FP U9082A-1TP GSM/EDGE U9071A-2 U9071A-2FP U9071A-2TP EDGE Evo U9071A-3 U9071A-3FP U9071A-3TP cdma2000 U9072A-2 U9072A-2FP U9072A-2TP W-CDMA U9073A-1 U9073A-1FP U9073A-1TP HSDPA/HSUPA U9073A-2 U9073A-2FP U9073A-2TP HSPA+ U9073A-3 U9073A-3FP U9073A-3TP 1xEV-DO U9076A-1 U9076A-1FP U9076A-1TP HSPA+ U9073A-3 U9073A-3FP U9073A-3TP TD-SCDMA U9079A-1 U9079A-1FP U9079A-1TP HSPA U9079A-2 U9079A-2FP U9079A-2TP Wireless connectivity Technology U90xxA measurement application model number Fixed Perpetual license Transportable Bluetooth U9081A-2 U9081A-2FP U9081A-2TP Mobile WiMAX U9075A-2 U9075A-2FP U9075A-2TP General purpose Technology U90xxA measurement application model number Fixed Perpetual license Transportable Analog demodulation U9063A-2 U9063A-2FP U9063A-2TP Transforming manufacturing test 5 5

Cellular Communications The cellular communication measurement applications cover a full range of technologies from existing 2G/3G systems to evolving 3.5G and 4G communication systems. These measurement applications adhere to the 3GPP and 3GPP2 standards, and closely follow standards as they change allowing you to stay on the leading edge of your design and manufacturing challenges. LTE-FDD LTE-FDD measurements per 3GPP Release 9 standard All LTE bandwidths: 1.4 to 20 MHz User equipment (UE): EVM, frequency error, I/Q offset, and in-band emissions LTE-TDD LTE-TDD measurements per 3GPP Release 9 standard All LTE bandwidths: 1.4 to 20 MHz User equipment (UE): EVM, frequency error, I/Q offset, spectrum flatness, in-band emissions, SEM, ACLR, and more Transport layer channel decoding: Access to demapped, deinterleaved, descrambled, deratematched, and decoded data Multiple color coded result views: EVM vs. subcarrier, EVM vs. symbol, EVM vs. slot, EVM vs. resource block (RB), detected allocations (subcarrier vs. symbol), error summary table, frame summary table, and more Channel power, occupied bandwidth, and ACP Multiple color-coded result views: EVM vs. subcarrier, EVM vs. symbol, EVM vs. slot, EVM, vs. resources block (RB), detected allocations (subcarrier vs. symbol), error summary table, frame summary table, and more Figure 3: LTE-TDD www.agilent.com/find/u9082a Figure 2: LTE-FDD www.agilent.com/find/u9080a 6 6

Cellular Communications GSM/EDGE/EDGE Evo GSM, EDGE, and EDGE Evo measurements per 3GPP GERAN standard GSM/EDGE measurements Transmit power and power vs time (PvT) with multi-slot capability Error vector magnitude (EDGE only), and phase and frequency error (GSM only) through polar vector and constellation displays GSM/EDGE loopback BER 1 EDGE Evo measurements Normal burst (NB) support: GMSK, 8PSK, 16QAM, and 32QAM High symbol rate (HSR) burst support: QPSK, 8PSK, 16QAM, and 32QAM including spectrally-narrow and wide-pulse shaping Tx filter Auto-detection and synchronization for all modulation formats including mixed slots containing NB and HSR bursts, plus enhanced trigger hold-off setting for stable burst detection W-CDMA/HSPA/HSPA+ W-CDMA, HSPA, and HSPA+ measurements per 3GPP release 99 to 8 W-CDMA measurements Auto-detection and analysis of W-CDMA channels and signals EVM, peak code domain error, frequency error, code domain power, plus more Channel power, ACP, occupied bandwidth PRACH power and slot power measurements W-CDMA loopback BER 1 HSPA (HSDPA/HSUPA)/HSPA+ measurements Auto-detection and analysis of 4PAM-I/Q (16QAM) E-DPDCH, 64QAM HS-PDSCH, plus preset for Test Model 6 HS-DPCCH, E-DPCCH, and E-DPDCH auto detection, and power beta calculations with DPCH/E-DPCH configuration settings EVM, peak code domain error, frequency error, code domain power, plus more Channel power, ACP, occupied bandwidth, and ACP Figure 4: GSM/EDGE/EDGE Evo www.agilent.com/find/u9071a Figure 5: W-CDMA/HSPA/HSPA+ www.agilent.com/find/u9073a 1. Supported by Sequence Analyzer Mode. Transforming manufacturing test 7 7

Cellular Communications cdma2000/cdmaone cdmaone and cdma2000 measurements per 3GPP2 Release A Composite rho and EVM, QPSK EVM, code domain error, frequency error, time offset, and power measurements Automatic detection of forward link signals from radio configuration (RC) 1 to 5 Displays code domain power (CDP) results in Hadamard code or bit-reverse 1xEV-DO 1xEV-DO measurements per Rel 0, Rev A and Rev B of 3GPP2 standard Reverse link: Composite EVM and rho, CPE, CDE, I/Q chip errors, code domain, channel power, and ACP Auto-detection for data channels QPSK, 8PSK, 16QAM, and 64QAM For reverse link, supports channel types including pilot, RRI, data, ACK, DRC, DSC, and auxiliary pilot Specifies chip and PN offsets, and measurement interval from 1 to 32 PCG (1 PCG=1536 chips) Figure 6: cdma2000/cdmaone www.agilent.com/find/u9072a Figure 7: 1xEV-DO www.agilent.com/find/u9076a 8 8

Cellular Communications TD-SCDMA/HSPA TD-SCDMA/HSPA measurements per 3GPP release 99 to 8 standards Uplink: EVM, frequency stability, transmit On/Off power, PkCDE, SEM, ACLR, and more Automatic detection of QPSK, 16QAM, and 8 PSK in code domain and modulation accuracy analysis Multiple result views: Constellation diagram, code domain, numeric display, spectrum, and time domain Figure 8: TD-SCDMA/HSPA www.agilent.com/find/u9079a Transforming manufacturing test 9 9

Wireless Connectivity The wireless connectivity measurement applications cover technologies including Bluetooth through Mobile WiMAX. As technology advances, U90xxA X-Series measurement applications are also advancing, enabling you to continue tackling increasingly complex design and manufacturing test challenges. Mobile WiMAX Mobile WiMAX measurements per IEEE 802.16 2005 standard RCE (EVM), RSSI, preamble PCINR, subcarrier flatness, and IQ metrics Time-gated power measurements: ACP and channel power Center frequency tolerance, symbol clock frequency tolerance, and power rise/fall Bluetooth Bluetooth measurements per Core Specification Version 2.1+ EDR and 4.0 Low Energy Transmitter analysis of combined output power (basic rate or low energy) or EDR relative power and modulation measurements associated with multiple results at a single time Modulation: Deviation, initial carrier frequency tolerance (ICFT), carrier frequency drift, EDR frequency stability, and EDR modulation accuracy Multiple result views: RF envelope, demodulation waveform, and numeric display Delivers relative constellation error (RCE) in multiple levels (composite, pilot, data burst, un-modulated, and preamble) Figure 10: Bluetooth www.agilent.com/find/u9081a Figure 9: Mobile WiMAX www.agilent.com/find/u9075a 10 10

General Purpose Analog demodulation is one of the general purpose X-Series measurement applications that has been leveraged for the EXT to expedite the development and manufacturing of various transmitting devices. Supported one-button measurements include all of the modulation quality plus I/Q waveform measurements. Analog demodulation Modulations analysis for AM, FM and PM signals Analyze analog modulation signals with a selection of detectors: Peak+, Peak-, (Pk-Pk)/2 and RMS View RF spectrum, demodulated waveform, AF (modulating signal) spectrum, and demodulation metrics table at the same time with quad view Play the modulating signal over a speaker ( tune and listen ) Figure 11: Analog demodulation www.agilent.com/find/u9063a Transforming manufacturing test 11 11

Flexible Software Licensing Software licensing and configuration Choose from two license types: Fixed, perpetual license A fixed license is the traditional licenses and ties an application to a specific instrument. Once installed, the license cannot be moved to another instrument and it becomes part of the test asset. Transportable, perpetual license The transportable license allows an application to be moved between instruments, providing you the flexibility to manage test and measurement capabilities in your organization, across the lab or around the globe, as your business needs evolve. A transportable license is available for all U90xxA X-Series applications. Please refer to the Product Summary for specific availability. You Can Upgrade! Options can be added after your initial purchase. All of our X-Series application options are license-key upgradeable Try Before You Buy! UP GRADE Free 14-day trials of X-Series measurement applications provide unrestricted use of each application s features and functionality on your X-Series analyzer. Redeem a trial license on-line today: www.agilent.com/find/x-series_ext_trial 10 12 12

myagilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG, Inc., U.S.A. and licensed to Agilent Technologies, inc. cdma2000 is a registered certification mark of the Telecommunications Industry Association. WiMAX, Mobile WiMAX, WiMAX Forum, the WiMAX Forum logo, WiMAX Forum Certified, and the WiMAX Forum Certified logo are US trademarks of the WiMAX Forum. Windows, Windows NT, MS Windows, and Windows Vista are trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Agilent Advantage Services is committed to your success throughout your equipment s lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world. www.agilent.com/find/advantageservices www.agilent.com/quality www.agilent.com www.agilent.com/find/e6607b For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3600 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus Revised: October 11, 2012 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2012 Published in USA, November 8, 2012 5991-0044EN