Feed-through terminal block - PT 10-TWIN

Similar documents
High-current terminal block - UKH

UTTB 4. Extract from the online catalog. Order No.:

Signal conditioner - MACX MCR-UI-UI-NC

UTTB 2,5. Extract from the online catalog. Order No.:

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

KDS10/SO. Extract from the online catalog. Order No.:

MC 1,5/ 4-ST-3,5. Extract from the online catalog. Order No.:

Safety relays - PSR-SCP- 24DC/ESD/4X1/

MKDSN 1,5/ 4-5,08. Extract from the online catalog. Order No.:

KDSP 4. Extract from the online catalog. Order No.:

SLKK 5. Extract from the online catalog. Order No.:

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

SMKDS 2,5/ 2-5,08. Extract from the online catalog. Order No.:

MKDS 3/ 4. Extract from the online catalog. Order No.:

MVSTBR 2,5/ 2-ST. Extract from the online catalog. Order No.:

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

DIK 1,5 General data Technical data General

AKG 4 GNYE. Extract from the online catalog. Order No.:

MSTB 2,5/ 4-ST. Extract from the online catalog. Order No.:

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

MVSTBW 2,5/ 5-ST. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

MSTB 2,5/ 3-ST. Extract from the online catalog. Order No.:

General data. Technical data DIKD 1,5. General. Dimensions

DEK-OV- 12DC/ 24DC/ 3

PSR-SCP- 24DC/ESD/5X1/1X2/300

Data sheet. W-Series WDU 2.5

Data sheet. W-Series WDU 2.5 RT

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Data sheet. W-Series WDU 10

Data sheet. W-Series WDU 4 BL

Data sheet... W-Series WDU 2.5

SAC-3P- 5,0-PUR/M12FR SH

Datenblatt. W-Series WDU 2.5

SAC-5P- 1,5-PUR/M12FS SH

Datasheet. W-series terminal with clamping yoke connection WDU 16

Datenblatt. W-Series WDU 10

Switching power supplies CP range, Linear power supplies CP-L range. Content

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Incandescent Lampholders: Edison Screw and Bayonet Cap

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Type CP-S, CP-C & CP-A Switch mode

MINI-PS AC/24DC/1.3

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Subject to changes 11/2003 Page 1/7

Extract from the online catalog

MACX MCR-EX-SL-RPSSI-I

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Data sheet Cable connector class F A

LED Driver Constant voltage

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Product Data Sheet 3254 J/2H3P

Primary switch mode power supplies Product group picture

Product Data Sheet 3252J/2H3PU

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Electronic timer CT-SDS.22

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Description Basic devices with positive operation contacts

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

VARIOCON. Modular Contact Inserts

Control module CP-A CM

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Three-phase monitoring relay CM-PFS

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Electronic timer CT-SDD.22

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

No-wear isolation of potentials in terminal block design

Capacitor Switching Contactors

Power supply CP-E 24/2.5

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

H0,75/14S W. 10/11/ H0,75/14S W Weidmüller Product Catalogue. Similar to illustration General ordering data. Dimensions and weights

Three-phase monitoring relays

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

Power supply CP-E 24/0.75

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

CP-E range Benefits and advantages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Through and Ground Conductor Terminal Blocks 290 Series

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

NS..S contactor relays - with spring terminals AC operated

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Transcription:

Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Feed-through terminal block, Connection method: Push-in connection, Cross section: - 16 mm², AWG: 20-6, Width: 10.2 mm, Height: 49.5 mm, Color: gray, Mounting type: NS 35/7,5, NS 35/15 Product Features The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free wiring of conductors with ferrules or solid conductors The compact design and front connection enable wiring in a confined space In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection Tested for railway applications Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 38.4 GRM Custom tariff number 85369010 Country of origin Poland General Number of levels 1 Number of connections 3 Color gray Insulating material PA Inflammability class according to UL 94 V0 Area of application Railway industry Mechanical engineering Plant engineering Maximum load current 70 A (with 16 mm² conductor cross section) Rated surge voltage 8 kv 11/05/2014 Page 1 / 7

General Pollution degree 3 Surge voltage category Insulating material group Connection in acc. with standard IEC 60947-7-1 Maximum load current (lower level) Nominal current I N (lower level) Nominal voltage U N Maximum load current (upper level) Open side panel III I 70 A (with 16 mm² conductor cross section) 57 A 1000 V 70 A (with 16 mm² conductor cross section) Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11 Back of the hand protection Finger protection Surge voltage test setpoint Result of surge voltage test Power frequency withstand voltage setpoint Result of power-frequency withstand voltage test Checking the mechanical stability of terminal points (5 x conductor connection) Bending test rotation speed Bending test turns 135 Bending test conductor cross section/weight Result of bending test Conductor cross section tensile test Tractive force setpoint Conductor cross section tensile test Tractive force setpoint Conductor cross section tensile test Tractive force setpoint Tensile test result ja guaranteed guaranteed 9.8 kv 2.2 kv 10 rpm / 0.3 kg / 2 kg 16 mm² / 2.9 kg 20 N 90 N 16 mm² 100 N Tight fit on carrier NS 35 Setpoint Result of tight fit test Result of voltage drop test Temperature-rise test Conductor cross section short circuit testing 5 N 11/05/2014 Page 2 / 7

https://www.phoenixcontact.com/us/products/3208746 Feed-through terminal block - PT 10-TWIN - 3208746 General Short-time current 1.2 ka Conductor cross section short circuit testing 16 mm² Short-time current 1.92 ka Short circuit stability result Ageing test for screwless modular terminal block temperature cycles 192 Result of aging test Proof of thermal characteristics (needle flame) effective duration 30 s Result of thermal test Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03 Test spectrum Service life test category 1, class B, body mounted Test frequency f 1 = 5 Hz to f 2 = 150 Hz ASD level 1.857 (m/s 2 ) 2 /Hz Acceleration 0.8g Test duration per axis 5 h Test directions X-, Y- and Z-axis Oscillation, broadband noise test result Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03 Shock form Half-sine Acceleration 5 g Shock duration 30 ms Number of shocks per direction 3 Test directions X-, Y- and Z-axis (pos. and neg.) Shock test result Temperature index, insulating material (DIN EN 60216-1 (VDE 0304-21)) 125 C Static insulating material application in cold -60 C Dimensions Width Length Height Height NS 35/7,5 Height NS 35/15 10.2 mm 88.9 mm 49.5 mm 50.5 mm 58 mm Connection data Connection in acc. with standard IEC 60947-7-1 Connection method Push-in connection Conductor cross section solid min. Conductor cross section solid max. 16 mm² 11/05/2014 Page 3 / 7

Connection data Conductor cross section AWG/kcmil min. 20 Conductor cross section AWG/kcmil max 6 Conductor cross section stranded min. Conductor cross section stranded max. Min. AWG conductor cross section, stranded 20 Max. AWG conductor cross section, stranded 8 Conductor cross section stranded, with ferrule without plastic sleeve min. Conductor cross section stranded, with ferrule without plastic sleeve max. Conductor cross section stranded, with ferrule with plastic sleeve min. Conductor cross section stranded, with ferrule with plastic sleeve max. 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. Stripping length Internal cylindrical gage 1.5 mm² 4 mm² 18 mm A6 Classifications ecl@ss ecl@ss 4.0 27141120 ecl@ss 4.1 27141120 ecl@ss 5.0 27141120 ecl@ss 5.1 27141120 ecl@ss 6.0 27141120 ecl@ss 7.0 27141120 ecl@ss 8.0 27141120 ETIM ETIM 3.0 ETIM 4.0 ETIM 5.0 EC000897 EC000897 EC000897 UNSPSC UNSPSC 6.01 30211811 UNSPSC 7.0901 39121410 UNSPSC 11 39121410 UNSPSC 12.01 39121410 11/05/2014 Page 4 / 7

Classifications UNSPSC UNSPSC 13.2 39121410 GOST / UL Recognized / cul Recognized / GL / CSA / LR / GOST / VDE Zeichengenehmigung / IECEE CB Scheme / NK / BV / culus Recognized Ex IECEx / ATEX submitted Approval details GOST UL Recognized B C mm²/awg/kcmil 20-6 20-6 Nominal current IN 60 A 60 A Nominal voltage UN 600 V 600 V cul Recognized B C mm²/awg/kcmil 20-6 20-6 Nominal current IN 60 A 60 A Nominal voltage UN 600 V 600 V 11/05/2014 Page 5 / 7

https://www.phoenixcontact.com/us/products/3208746 Feed-through terminal block - PT 10-TWIN - 3208746 GL CSA B C mm²/awg/kcmil 20-6 20-6 Nominal current IN 55 A 55 A Nominal voltage UN 600 V 600 V LR GOST VDE Zeichengenehmigung mm²/awg/kcmil 0.5-10 Nominal current IN 57 A Nominal voltage UN 1000 V IECEE CB Scheme Nominal current IN Nominal voltage UN 57 A 1000 V NK BV culus Recognized 11/05/2014 Page 6 / 7

Drawings Circuit diagram Phoenix Contact 2014 - all rights reserved http://www.phoenixcontact.com 11/05/2014 Page 7 / 7