The Effect of Sample Size on Result Accuracy using Static Image Analysis

Similar documents
LA-950 Laser Diffraction Analyzer

Foreign Particulate Matter testing using the Morphologi G3

Determining Dimensional Capabilities From Short-Run Sample Casting Inspection

One-Sample Z: C1, C2, C3, C4, C5, C6, C7, C8,... The assumed standard deviation = 110

GB/T Translated English of Chinese Standard: GB/T

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

Chapter 6 Introduction to Statistical Quality Control, 6 th Edition by Douglas C. Montgomery. Copyright (c) 2009 John Wiley & Sons, Inc.

ISO INTERNATIONAL STANDARD. Photography Root mean square granularity of photographic films Method of measurement

TenMarks Curriculum Alignment Guide: EngageNY/Eureka Math, Grade 7

ME scope Application Note 01 The FFT, Leakage, and Windowing

The HORIBA LA-960. Simple, Powerful, Reliable Particle Size Measurement. Ian Treviranus

(Notice that the mean doesn t have to be a whole number and isn t normally part of the original set of data.)

Laboratory 1: Uncertainty Analysis

Measurement over a Short Distance. Tom Mathew

EE EXPERIMENT 3 RESISTIVE NETWORKS AND COMPUTATIONAL ANALYSIS INTRODUCTION

SEM Magnification Calibration & Verification: Building Confidence in Your Scale Bar

Physics 2310 Lab #5: Thin Lenses and Concave Mirrors Dr. Michael Pierce (Univ. of Wyoming)

(3 pts) 1. Which statements are usually true of a left-skewed distribution? (circle all that are correct)

Leading in Desktop SEM Imaging and Analysis

Experiment 2: Transients and Oscillations in RLC Circuits

Optical Proximity Effects

MEASURING TINY SOLDER DEPOSITS WITH ACCURACY AND REPEATABILITY

Q Scheme Marks AOs. 1a All points correctly plotted. B2 1.1b 2nd Draw and interpret scatter diagrams for bivariate data.

SIEVE CERTIFICATION SYSTEM

NSCAS - Math Table of Specifications

Effect of Reticle CD Uniformity on Wafer CD Uniformity in the Presence of Scattering Bar Optical Proximity Correction

ISO INTERNATIONAL STANDARD. Photography Root mean square granularity of photographic films Method of measurement

A Step-wise Approach for Color Matching Material that Contains Effect Pigments. Dr. Breeze Briggs, BASF Colors & Effects USA LLC, ANTEC 2017

Measurement Statistics, Histograms and Trend Plot Analysis Modes

High-Throughput Precise Dotting in Electronics Assembly

There is a twenty db improvement in the reflection measurements when the port match errors are removed.

Extending Acoustic Microscopy for Comprehensive Failure Analysis Applications

GenePix Application Note

Statistics Laboratory 7

Possible responses to the 2015 AP Statistics Free Resposne questions, Draft #2. You can access the questions here at AP Central.

Supplementary Note 1: Structural control of BCs. The availability of PS spheres in various

Describing Data Visually. Describing Data Visually. Describing Data Visually 9/28/12. Applied Statistics in Business & Economics, 4 th edition

Precision. A Vision for. Weaving Innovation. Orthopaedic Instruments Break Tradition. OrthoTecOnline.com PREMIERE ISSUE

Morphologi. Advanced image analysis for high sensitivity particle characterization. Particle size. Particle shape

Applications of Flash and No-Flash Image Pairs in Mobile Phone Photography

HPN E The solution to determine the measurement uncertainty

Lab E2: B-field of a Solenoid. In the case that the B-field is uniform and perpendicular to the area, (1) reduces to

End-of-Chapter Exercises

CS 445 HW#2 Solutions

Image analysis. CS/CME/BioE/Biophys/BMI 279 Oct. 31 and Nov. 2, 2017 Ron Dror

Prediction of building entry loss

LION. TechNote LT September, 2014 PRECISION. Understanding Sensor Resolution Specifications and Performance

Analysis and design of filters for differentiation

MODEL 5002 PHASE VERIFICATION BRIDGE SET

Page 21 GRAPHING OBJECTIVES:

Revisions to ASTM D7310 Standard Guide for Defect Detection and Rating of Plastic Films Using Optical Sensors

SECONDARY ELECTRON DETECTION

Session 5 Variation About the Mean

ISO INTERNATIONAL STANDARD

Bend Sensor Technology Mechanical Application Design Guide

Bend Sensor Technology Mechanical Application Design Guide Mechanical Application Design Guide

WITH MATH INTERMEDIATE/MIDDLE (IM) GRADE 6

Grades 6 8 Innoventure Components That Meet Common Core Mathematics Standards

EXPERIMENTAL ERROR AND DATA ANALYSIS

Physics 253 Fundamental Physics Mechanic, September 9, Lab #2 Plotting with Excel: The Air Slide

AP STATISTICS 2015 SCORING GUIDELINES

Acoustic resolution. photoacoustic Doppler velocimetry. in blood-mimicking fluids. Supplementary Information

Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination.

Operations Management

Protocol for extracting a space-charge limited mobility benchmark from a single hole-only or electron-only current-voltage curve Version 2

AHRI Standard Standard for Performance Rating of Modulating Positive Displacement Refrigerant Compressors

An Evaluation of Artifact Calibration in the 5700A Multifunction Calibrator

Evaluation of High Intensity Discharge Automotive Forward Lighting

This document is a preview generated by EVS

Second Quarter Benchmark Expectations for Units 3 and 4

Independent Tool Probe with LVDT for Measuring Dimensional Wear of Turning Edge

Developments in Electromagnetic Inspection Methods II

Some of the proposed GALILEO and modernized GPS frequencies.

Using Rank Order Filters to Decompose the Electromyogram

VARIANCE AS APPLIED TO CRYSTAL OSCILLATORS

SENSORS SESSION. Operational GNSS Integrity. By Arne Rinnan, Nina Gundersen, Marit E. Sigmond, Jan K. Nilsen

AnalyzeLoad User s Manual (Version 3.1, Dec 2017)

Standard Test Method for Determining the L/D Ratio of Neutron Radiography Beams 1

Blade Tip Timing Frequently asked Questions. Dr Pete Russhard

Tutorial on the Statistical Basis of ACE-PT Inc. s Proficiency Testing Schemes

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

Assessment of Hall A Vertical Drift Chamber Analysis Software Performance Through. Monte Carlo Simulation. Amy Orsborn

Mathematics (Project Maths)

A New Single-Photon Avalanche Diode in 90nm Standard CMOS Technology

For the system to have the high accuracy needed for many measurements,

Lab 2 Geometrical Optics

Lab Report 4: Root Locus and Proportional Controller

System NMI. Accuracy is the Key. Classifying the Content of Non-metallic Inclusions in Steel in Accordance with Current Industrial Standards

4th Grade Mathematics Mathematics CC

IE 361 Module 7. Reading: Section 2.5 of Revised SQAME. Prof. Steve Vardeman and Prof. Max Morris. Iowa State University

Chapter 11. Sampling Distributions. BPS - 5th Ed. Chapter 11 1

ANALYSIS OF MEASUREMENT ACCURACY OF CONTACTLESS 3D OPTICAL SCANNERS

Seven Basic Quality Control Tools HISTOGRAM TOOL

Figure1. To construct a light pulse, the electric component of the plane wave should be multiplied with a bell shaped function.

Probability WS 1 Counting , , , a)625 b)1050c) a)20358,520 b) 1716 c) 55,770

GEOMETRICAL TOLERANCING

Resolution. [from the New Merriam-Webster Dictionary, 1989 ed.]:

Analyzing Data Properties using Statistical Sampling Techniques

FY07 New Start Program Execution Strategy

Vector-Receiver Load Pull Measurement

Transcription:

The Effect of on Result Accuracy using Static Image Analysis Optical microscopy has been a useful tool for particle characterization for many years. This is considered the referee technique since it is the most direct method available. One caveat is that the number of particles inspected (counted) must be sufficient so that there is confidence in the results generated. Several approaches have been suggested for determining the minimum number of particle counted in order to achieve desired confidence levels. This study reviews two standards that set the number of particles counted and compares these to experimental results. Introduction The number of particles counted is directly related to the width (breadth) of the distribution. If all of the particles in a sample are a single size, then only a single particle needs to be measured. But if the sample has a broad distribution then it is intuitively obvious that many particles should be measured. Just how many particles to inspect has been the subject of debate and may still be an unresolved issue. The number of particles to count is influenced by several factors including: Width of the distribution Desired confidence level Basis of the distribution (number vs. volume) Results of interest (mean, d10, d90, etc.) In practice, the number of particles inspected is also influenced by whether the measurements are made manually or using automated image analysis software. Countless papers are published every year containing one view of an SEM image followed by conclusions regarding the particle size distribution and morphology of the sample. On the other end of the spectrum lie results generated by automated image analysis systems where thousands or hundreds of thousands of particle have been inspected. USP<776> The United States Pharmacopeia (USP) test USP <788> OPTICAL MICROSCOPY 1 was published prior to wide scale use of automated image analysis and generally refers to manual microscopy. These standard states: The number of particles characterized must be sufficient to ensure an acceptable level of uncertainty in the measured parameter For a sufficiently large population (n > 30), the uncertainty in the estimate for the mean particle diameter, d, is given in the formula: d ± zc s n Where n = number of particle to count d = mean particle diameter (number distribution) z c = desired confidence coefficient s = standard deviation of the test specimen According to USP <776> z c is about 1.96 at the 95% confidence level for

n>30. Using the equation shown above an example calculation would suggest that for a sample with a standard deviation of 20 µm, 61 particles could be counted in order to achieve at uncertainty of 5 µm for the number mean. Several observations on this approach could include questioning if n>30 constitutes a sufficiently large population, pointing out that volume distributions are preferred over number 2, and noting that the equation provides no guidance on other parts of the distribution (d10 and d90). The FDA expects d10, d50, and d90 values for active ingredient specifications, not just the mean diameter. ISO 13322 Another approach to determining the necessary number of particles to observe for creating statistically valid particle size distributions is given in ISO 13322 3. The following quote is taken from Section 1. Scope: Even though automation of the analysis is possible, this technique is basically limited to narrow size distributions of less than an order of magnitude. A standard deviation of 1,6 of a log-normal distribution corresponds to a distribution of less than 10:1 in size. Such a narrow distribution requires that over 6 000 particles be measured in order to obtain a repeatable volume-mean diameter. If reliable values are required for percentiles, e.g. D90 or other percentiles, at least 61 000 particles must be measured. All of the statements in the paragraph above can be questioned. Image analysis is currently being used successfully to determine particle size (and shape) distributions much broader than one order of magnitude. Although the guidance given in ISO 13322 for the number of particles to be counted provides a theoretically correct and cautious approach, the experimental data shown in this technical note indicates that accurate results can be achieved even when inspecting far fewer particles. The basis of the approach described in ISO 13322 was first published by Masuda and. Gotoh 4. This theoretical approach assumes the particles are log-normally distributed, and suggests that the required number (N) of particles with a given error (σ ) and a given confidence limit is estimated in accordance with the following equation: log N = 2 log δ + K where K is numerically determined by the confidence limit, particle distribution and other parameters. Following the approach given in ISO 13322 tables are generated displaying the number of particle to be counted depending on the distribution width, confidence limit, and desired mean value. One of these tables is shown in Table 1 below. Number of particles required n*, δ = 0.05, p = 0.95 δ GSD n*(mmd) n*(sauter) n*(mvd) 0.05 1.1 585 389 131 1.15 1460 934 294 1.2 2939 1808 528 1.25 5223 3103 843 1.3 8526 4920 1247 1.35 13059 7355 1750 1.4 19026 10504 2363 1.45 26617 14457 3093 1.5 36007 19295 3956 1.55 47358 25093 4952 1.6 60811 31919 6092 Table 1: from ISO 13322

Interpreting table 1 can be challenging. The basis of this table is to show the number of particles that need to be inspected in order to determine a median or mean diameter within a 5% error with 95% probability. The geometric standard deviation (GSD) of the distribution of the sample must be known prior to using this table. Unfortunately, few particle sizing techniques use GSD to express distribution width. Most techniques express distribution width using either the standard (arithmetic) deviation or the span (d90-d10/d50). The column n*(mmd) refers to the mass median diameter, the column n*(sauter) refers to the surface median diameter, and the column n*(mvd) refers to the mean volume diameter. If the three columns referred to volume, surface, and number distributions, the data would make more sense. It is difficult to understand why more particles need to be inspected in order to calculate the surface median than the volume mean diameter. Experimental It is also possible to take an experimental approach to the subject of how many particles to inspect to achieve desired accuracy. For this study the static image analysis system (Figure 1) was used to measure particle size distributions of several samples. All samples were prepared using the powder Disperser Unit in order to separate agglomerates and create an even distribution of particles on the slide. Each sample was measured on the by varying the number of fields inspected on the slide in order to inspect more or less particles. Plots showing the number of particles inspected vs. d10, d50, and d90 then provide insight into the effect of sample size. All plots were converted from a number to a volume basis. Figure 1: The The first sample studied was a polydisperse standard from Whitehouse Scientific, HS202. This sample has a known particle size distribution as measured on several techniques including microscopy. The certified values (volume basis) for this material are: d10 = 9.6 µm d50 = 13.4 µm d90 = 20.8 µm Results from measuring this sample on the are shown in Table 2 and Figure 2. Count d10 d50 d90 36 9.7 12.8 14.7 84 9.6 13 15 292 10 13.6 17.1 509 10.4 14.2 19.9 824 10.6 14.2 19.8 1412 10.3 14.2 20 Table 2: Data for Figure 2

25 20 15 10 5 0 0 200 400 600 800 1000 1200 1400 1600 d10 d50 d90 Figure 2: d10, d50, d90 (volume basis) vs. count for HS202 The d90 plot is the easiest way to visualize the effect of sample size on results. For this sample, the d90 result reached the specification after ~500 particles were counted. The arithmetic standard deviation for this sample was determined to be ~ 4 µm. Using the GSD value of 1.6 from Table 1, ISO 13322 recommends counting at least 6092 particles to achieve a 5% at the volume mean. The experimental data in Table 3 and Figure 1 indicated that only 500 particles need to be counted to achieve an error under 5% at the d90 from the volume distribution. The d50 value was within specification after inspecting only 300 particles. An additional sample without a known distribution was measured to investigate the deviation between the theoretical requirements in ISO 13322 and observed experimental values. Table 3 and Figure 3 presents a similar plot of d10, d50, and d90 (volume basis) vs. number of particles inspected. The standard deviation for the sample was 27. 120 100 80 60 40 20 Count d10 d50 d90 47 26.7 54.8 64.5 82 20.3 55.8 64 207 27.8 66.8 91.3 534 33.5 82.8 107.3 1336 32.1 79.2 108.6 2627 32.3 77 101.4 4203 31.5 76.2 106.7 8270 29.7 73.8 104.2 Table 3: Data for Figure 3 0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 d10 d50 d90 Figure 3: d10, d50, d90 (volume basis) vs. count for an unknown sample The wavy nature of this plot suggests that the first data point is extremely inaccurate and that several large particles were inspected during the fourth and fifth measurement, creating the unusual appearance. Both of these points reinforce the need to inspect a large number of particles. But even with this broader distribution the data for the d90 is acceptable after 4200 particles were inspected, far fewer that suggested by ISO 13322. Conclusions Image analysis is becoming a more accepted technique for particle size (and shape) analysis in many industries. The number of particle inspected can now be much higher

with the implementation of automated image analysis. The equation given in USP <776> does not appear appropriate for most samples. A population of 30 to 60 particles is not supported either theoretically or experimentally. On the other hand, the theoretical values suggested by ISO13322 appear significantly higher than data supported by experiments. The number of particles inspected for confident and accurate results may be closer to 6,000 for most samples than 60,000. References 1. USP<788> Optical Microscopy, United States Pharmacopeia 2. Burgess, J., Duffy, E., Etzler, F., Hickey, A, Particle Size Analysis: AAPS Workshop Report, Cosponsored by the Food and Drug Administration and the United States Pharmacopeia, AAPS Journal 2004; 6 (3) Article 20 (http://www.aapsj.org) 3. ISO 13322-1, Particle Size Analysis Image Analysis Methods Part 1: Static Image Analysis Methods 4. Masuda, H. & Gotoh, K., Study on the sample size required for the estimation of mean particle diameter, Advanced Powder Technol., 10(2), 1999, pp. 159-173 Copyright 2008, HORIBA Instruments, Inc. For further information on this document or our products, please contact: HORIBA Instruments, Inc. 17671 Armstrong Ave. Irvine, CA 92614 USA (949) 250-4811 labinfo@horiba.com www.horibalab.com