ASSEMBLY AND INSTALLATION INSTRUCTIONS

Similar documents
ASSEMBLY AND INSTALLATION INSTRUCTIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Mounting Bracket Screw

Smart Task Motion Activated Task Light Installation Manual

Installation Instructions

3000W MULTI PIR LIGHT CONTROLLER

3000W multi Pir light controller

Mini Sensor. Outdoor Motion Sensor. Installation Manual

SmartBox RAB. Installation Manual. Outdoor Motion Sensor. It s easy to add. motion detection to all your outdoor lights! Contents.

Smart Post RAB. Installation Manual. Outdoor Motion Sensor. It s easy to add. motion detection to your post lantern! Contents.

Datasheet ENGLISH Halogen lamp 120W with motion sensor ( ) Halogen lamp 400W with motion sensor ( )

with Light Level, Isolated Relay and Manual On features

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

STL200/277 Installation Manual STL200/277

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

Woven Leather Chandelier Large Assembly and Installation Instructions

Tuff Dome. Installation Manual. vandal resistant. Outdoor Motion Sensor. Contents. Specifications. Switching Capacity:

FFLED18 INSTALLATION INSTRUCTIONS

MADELINE METAL CHANDELIER

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

STL200/277 Installation Manual STL200/277

STEALTH. STL200 Installation Manual. Specifications: STL200 STL200H STL200HB. Switching Capacity: 8 amps

Installation Manual. Specifications: Cautions: TURN OFF ALL POWER AT CIRCUIT BREAKER / FUSE PANEL.

Custom Pendant- Hardwire Assembly and Installation Instructions

STEALTH. STL110 Installation Manual. Specifications: STL110 STL110HB STL110H STL110R. Switching Capacity:

Nash Chandelier Assembly and Installation Instructions

Installation Instructions SKU# , Rated Voltage V~ 50Hz

GLASS GLOBE MOBILE LINEAR CHANDELIER

Fabric tiered drum pendant 30in Assembly and Installation Instructions

GLASS GLOBE MOBILE 6-ARM CHANDELIER

PARTS INCLUDED TOOLS & PARTS NEEDED Do not mount on vibrating surfaces. appro to 2.5 meters 12M

Installation Instructions

18W Nightsensor Bulkhead

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

DAWN TO DUSK SENSOR OWNER S MANUAL

Riverside. Windward Bay EntertaInment Wall System Assembly Instructions. Made In Viet Nam. Right Pier. Bridge & Back Panel.

ROPE CHANDELIER - FRAME ASSEMBLY & INSTALLATION INSTRUCTIONS

FFLED18 INSTALLATION INSTRUCTIONS

Inigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

INSTALLATION MANUAL PBL-UMP

Installation Instructions

INSTALLATION INSTRUCTIONS

WALL LANTERN ITEM # MODEL #LWS1204C ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Allegro Home Office Assembly Instructions. Tipping Restraint. Bun Foot W/ Leveler. 4 pcs.

Eco-$mart, Inc. TOLL FREE:(888) FAX:(941)

INSTALLATION MANUAL PBC-UMS

PORTA~TRACE. GAGNE, INC. 41 Commercial Dr. Johnson City, New York Phone: Fax: ASSEMBLY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS:

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

Installation Instructions

SmartBox. Outdoor Motion Sensor. Installation Manual

INSTRUCTION MANUAL. 1 Light Exterior Wall Lantern. Home Depot SKU (UPC ) Home Depot SKU (UPC ) (Prairie Bronze)

PARTS & ASSEMBLY SHEET

Installation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine

The wick in your heater needs replacing if, after repeated cleanings, any of the following conditions still exist:

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

v3 360 Passive Infrared Line Voltage Occupancy Sensor

This document is intended for Lighting Control Systems professionals

Installation Instructions

BEFORE YOU BEGIN Read these instructions completely and carefully.

Monitor mount for 2017 P-series Dell monitors. Installation guide

BEFORE YOU BEGIN Read these instructions completely and carefully.

Installation Instructions

Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

HD-CXENVL-FDR Envelope Feeder Assembly and Operations Guide

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

Section 7 Inteli-Touch Series Casablanca Fan Co. - Factory Service Department - Technical Library

Installation Instructions

Installation Manual. The STEALTH 360 is the most reliable and technically advanced motionactivated

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Installation Instructions

INSTRUCTION MANUAL DWX723-XE HEAVY-DUTY MITER SAW STAND FINAL PAGE SIZE : 8.5IN X 5.5IN

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

Installing the FSP-211 Sensor in Light Fixture

CES SENSORS INSTALLATION AND MAINTENANCE MANUAL (IMM)

Over the Range Microwave Oven

Replacing the Reciprocator on the SWF Compact Series Machine (601C and 1201C)

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

LED Shoebox Light MOUNTING GUIDES S: SLIP FITTER MOUNTING. Step 2. Step 1. Dimensions of the slip fitter

Quolis 5000 Light INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-820 IMPORTANT

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

ASSEMBLY INSTRUCTION FOR WYTHE BURLED WOOD BAR

Instruction Sheet P/N B Trim the new RTD wires. 5. Coat the new RTD with. 4. Strip the ends of the existing

Installation Instructions (For Dealer or Contractor)

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

SMARTBULLET SMSBULLET2X12

Installation Instructions

DLA-E (Philips EvoKit) The DLA-E is designed to install in the mounting slot of the Philips EvoKit SR retrofit kit.

F5513 APOGEE 30"DIA 3LTS PENDANT INSTALLATION INSTRUCTIONS WARNING

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

PARTS & ASSEMBLY SHEET

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

MC CHANGER CABINET INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Transcription:

T0103 ASSEMBLY AND INSTALLATION INSTRUCTIONS WARNING: TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF POWER WHILE INSTALLING OR SERVICING THIS FIXTURE. NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. READ AND SAVE THESE INSTRUCTIONS. Hardware Package (included): Mounting Screw (A) Mounting Screw (B) Mounting Screw (C) Mounting Bracket Screw (D) Mounting Strap (E) Wire Nut (G) Important to Know: 1. If you are not familiar with state and local electrical codes, it is recommended that you consult with a qualified electrician. 2. This fixture requires a 120 VAC, 60 Hz power source. 3. For general safety and to avoid any possible damage to the sensor, be sure the power is switched "off" before adjustment. Maximum Wattage: 34 W Working Temperature Range: -4 0 F ~ 113 0 F Features: 1. Energy saving LED fixture. 2. Motion sensor: turns light ON automatically when motion is detected and turns light OFF automatically when motion stops. 3. Photocell keeps the light OFF during daylight hours. 4. When in manual override mode, use wall switch to keep the light ON during the night. Note: Fixture can be wall mounted or eave mounted. Wall Mounted Eave Mounted Light fixture and sensor should be mounted as shown above when installed (depending upon type of installation) Before installing the light fixture under an eave, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. For eave mounted only: Swing the sensor head towards the mounting bracket. Mounting Bracket Rotate the sensor head clockwise 180 so the controls face down. T0103 --- Page 1 / 5

Wire Nut (G) FRONT Mounting Bracket Mounting Bracket Screw (D) Back Plate Light Head Outlet Box Installation Steps Mounting Strap (E) Turn off the power at fuse or circuit box. Mounting Screw (A) 1. The fixture mounting bracket is pre-assembled on the light fixture. Unscrew both the decorative cover and the fixture mounting screw in order to remove the mounting bracket. 2. Install the mounting strap to the outlet box with the stamped word FRONT facing away from the outlet box, using two mounting screws that best fit the outlet box. 3. Pull out the source wires from the outlet box. Make wire connections using wire nuts as follows: ---Connect the black wire from the fixture to the black wire from the power source. ---Connect the white wire from the fixture to the white wire from the power source. ---Connect the grounding wire from the fixture to the grounding wire from the power source. (usually green / yellow insulation) Carefully tuck the wires back into the outlet box. Fig. 1 Sensor 4. Place mounting bracket against the outlet box, insert the mounting bracket screw through the mounting bracket hole, thread mounting bracket screw into the center hole of the mounting strap. Tighten the mounting bracket screw securely. When mounting to a wall, the UP arrow must point upward. (See Fig. 1) When mounting to an eave, the UP arrow must point toward the building. 5. Attach the back plate of the light fixture to the mounting bracket, secure it with the fixture mounting screw. 6. With silicone caulking compound, caulk completely around where the mounting bracket meets the wall surface. CAUTION: Be sure to caulk completely where the mounting bracket meets the wall surface to prevent water from seeping into the outlet box. Turn on the power at the main fuse or circuit breaker box. Adjusting the Sensor Head: 1. Aim sensor head toward desired detection area, maintaining a 5-40 downward angle to allow moisture to drain. Note: Make sure sensor head is positioned with control knob facing towards the ground. 2. You can rotate the sensor head up and down to change the coverage area. (See Fig. 2) Walk through the detection zone at the farthest distance you wish to detect motion. Note: Range set too high may increase false triggering. (See Fig. 3 and Fig. 4 on Page 3) Fig. 2 sensor T0103 --- Page 2 / 5

Fig. 3 Fig. 4 Adjustment Sensor Higher For Long Coverage Adjustment Sensor Lower For Short Coverage Sensitivity of Motion Sensor You can adjust the sensitivity of the motion sensor by using the SENSITIVITY selector located on the right side of the bottom surface of the sensor. (See Fig. 6) Adjust motion sensor sensitivity to HIGH (H), MEDIUM (M), or LOW (L) to achieve desired performance. Approximate range for each setting: 20 ft. (L), 45 ft. (M), 70 ft. (H). Adjusting the Light Head: 1. Gently grasp the light heads and tilt them up or down, left or right to adjust the light coverage area. Keep the light heads at least 1 (25mm) away from the sensor.(see Fig. 5) Fig. 5 2. Keep the light heads 30 below horizontal to avoid water damage and electrical shock. Function and Operation Note: When power is first applied, the light will turn on to 100% brightness. The sensor will take 30 seconds to warm up. 1. AUTO MODE (nighttime operation only) After expiration of the warm-up period, the light will enter a 5-minute TEST mode (day and night operation) and be on at low-level brightness (0-50%). The light will turn to highlevel brightness (100%) when motion is detected. It will then revert to low-level brightness about 5 seconds after motion is no longer detected. After expiration of the TEST mode, the light will automatically enter AUTO mode and be on at low-level brightness (0-50%). The light will turn to high-level brightness (100%) when motion is detected. When the motion stops, the light will then revert to low-level brightness after the shut-off delay time you set ( 5 ~ 180 seconds). Note: You can adjust the low level brightness (0~50%) by using the low level brightness knob. (See Fig. 7) Fig. 6 Mode Fig. 7 Sensitivity 2. 3 HOURS (3H) MODE (nighttime operation only) The light will turn to high-level brightness (100%) at dusk, and will stay "ON" for 3 hours. The light will then turn to low-level brightness. The light will turn to high-level brightness (100%) when motion is detected, and will stay on as long as motion continues. When motion is no longer detected, the lights will remain on for the predetermined shut-off delay Delay Time Low Level Brightness time you set (5~180 seconds), and then turn to the predetermined low-level brightness automatically. Note: You can adjust the low level brightness (0~50%) by using the low level brightness knob. (See Fig. 7) T0103 --- Page 3 / 5

3. 6 HOURS (6H) MODE (nighttime operation only) The light will turn to high-level brightness (100%) at dusk, and will stay "ON" for 6 hours. The light will then turn to low-level brightness. The light will turn to high-level brightness (100%) when motion is detected, and will stay on as long as motion continues. When motion is no longer detected, the lights will remain on for the predetermined shut-off delay time you set (5~180 seconds), and then turn to the predetermined low-level brightness automatically. Note: You can adjust the low level brightness (0~50%) by using the low level brightness knob. (See Fig. 7) 4. PHOTOCELL (PC) MODE (nighttime operation only) The light will brighten at dusk. It will turn off at dawn. Fig. 8 Manual Override Operation Diagram 5. Manual Override (nighttime operation only) To shift to the manual override mode, set the mode selector to AUTO, 3H or 6H mode. Turn the wall switch OFF, and turn it ON twice within 3 seconds. The light will remain on all night long. To shift back to AUTO, 3H or 6H mode, turn the wall switch OFF, and turn it ON twice within 3 seconds again. AUTO 3H or 6H Mode Turn wall switch OFF-ON -OFF-ON in 0.5~3 Seconds Turn wall switch OFF-ON -OFF-ON in 0.5~3 Seconds Manual Override Note: To make sure the above functions operate properly, always keep the wall switch in the ON position (including the daytime). Customization Options: Shut-off Delay The shut-off delay is the length of time the light will stay at brightness after motion has ceased to be detected. You can set the shut-off delay by rotating the delay time knob arrow so it points to the desired time setting within TIME range. To increase the shut-off delay, turn the knob clockwise. To decrease the shut-off delay, turn the knob counterclockwise. Notes: 1. The sensitivity of the motion sensor will increase as the environmental temperature gets cooler. You may wish to make adjustments when the season changes. For best performance, gently clean the lens with a soft cloth every 1 or 2 months to assure maximum sensitivity. 2. For best performance, install fixture at least 8 feet above the ground. At such a height, the fixture will provide a detection distance of up to 70 feet at 77 degrees Fahrenheit. (See Fig.9) Where you install your fixture is important: Be sure the light is mounted straight on the wall or eave; otherwise, the detection distance may be limited. 12.0' 8.0' 20' Fig. 9 Fig. 10 70' 360 3. The sensor detects movement across a detection range of 360 degrees. (See Fig.10) 4. The sensor will be more sensitive to motion across its detection path than motion directly towards it. (See Fig.11) Fig. 11 5. To reduce possible nuisances, do not mount the fixture near a heat source like an air conditioner, vent or furnace exhaust, or in a direction facing any reflecting object or other light source. Motion Least sensitive Sensor Motion Most sensitive T0103 --- Page 4 / 5

Troubleshooting ---The light does not come on at all: 1. Make sure the wall switch and circuit breaker are on. 2. Make sure the wiring is correct. 3. Cover the sensor with dark color cloth to verify that the ambient light level is not too high. ---In TEST mode, the light stays on over 5 seconds after motion is no longer detected: 1. Cover the sensor with a dark color cloth to verify that motion is not detected. 2. The TEST mode may have expired. If you want to reactivate the TEST mode, reboot the power ---In AUTO Mode, the light stays on during the day: 1. The light may be in TEST mode. Stay out of the detection range for 5 minutes, which will allow conversion to AUTO mode. ---In 3H or 6H Mode, the light is still on full brightness, even though it has been 3 hours or 6 hours after dusk: 1. Make sure there has not been an interruption in the electrical power, i.e. the wall switch has not been switched off and turned back on at some point or the circuit breaker had not shut down. ---After performing 3H or 6H Mode, the light stays on full brightness after 3 minutes: 1. Make sure there is no movement that could be picked up by the sensor. 2. Adjust the delay time knob counterclockwise to reduce the delay shut-off time. ---In Manual override, the light stays on after dawn: 1. The ambient light level may be too low due to overcast skies. The following parts are available for re-order if damaged or missing. Mounting Screw (A) Mounting Screw (B) Mounting Screw (C) Mounting Bracket Screw (D) Mounting Strap (E) Wire Nut (G) Assembly Kit 5077MM (1 SET) A: 13-1/8" B: 9" C: 6-3/8" T0103 --- Page 5 / 5