High-speed programmable attenuator MAT800

Similar documents
Operating Manual. Model 6010/6011/6012/6013 Highspeed Programmable Attenuator

Handheld 3.3GHz Spectrum Analyzer

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Arbitrary/Function Waveform Generators 4075B Series

Analog Arts AG900 AG885 AG875 AG815 Product Specifications

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1]

7075 WAVEFORM GENERATOR SIGNAL SOURCE

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

Analog Arts SF990 SF880 SF830 Product Specifications

Model 855 RF / Microwave Signal Generator

Analog Arts SF900 SF650 SF610 Product Specifications

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

Publication Number ATFxxB Series DDS FUNCTION WAVEFORM GENERATOR. User s Guide

DG5000 series Waveform Generators

Chapter 6 Specifications

RIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

4 K to 512 K words (2 n, n = 12 to 19) or 2 to 10,000 control points (linear interpolation between control points)

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

This DDS function generator is designed for use in such applications as communication equipment and electronic components production.

Model 865 RF / Ultra Low Noise Microwave Signal Generator

MOBILE COMMUNICATIONS MEASURING INSTRUMENTS

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

Chapter 13 Specifications

DG5000 Series Specifications

ArbStudio Arbitrary Waveform Generators

15. Specifications WF1947/WF

Data Sheet. DG1000 series Dual-Channel Function/Arbitrary Waveform Generators. Product Overview. Main Features. Applications. Easy to Use Design

RIGOL Data Sheet. DG2000 Series Function/Arbitrary Waveform Generator DG2041A, DG2021A. Product Overview. Main Features.

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz

80MHz/50MHz Arbitrary Function Generator

2400C Series Microwave Signal Generators 10 MHz to 40 GHz. Preliminary Technical Datasheet. Low Phase Noise and Fast-Switching Speed in a Single Unit

RIGOL Data Sheet. DG1022 Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

Function/Arbitrary Waveform Generator

DG4000. Series Function/Arbitrary Waveform Generator RIGOL TECHNOLOGIES, INC.

Spectrum Analyzers R3132/3132N/3162 R3132/3132N/3162. Low cost, high performance. General-Purpose Spectrum Analyzer Adaptable to Various Applications

Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963

Model 310H Fast 800V Pulse Generator

Characteristics. Frequency (DG1022) Sine, Square, Ramp, Triangle, Pulse, Noise, Arb. ±50 ppm in 90 days ±100 ppm in 1year 18 C ~ 28 C.

Specifications DG1022 & DG1022A

Technical Datasheet GT-8550B Series USB Power Sensor 10 MHz to 26.5 GHz

WaveStation Function/Arbitrary Waveform Generators

DG4000 Series Waveform Generators

WaveStation Function/Arbitrary Waveform Generators

LB680A Pulse Profiling USB PowerSensor+ Data Sheet

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

LB679A CW and Pulse (Modulation) USB PowerSensor+ Data Sheet

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

CIRCUIT-TEST ELECTRONICS

Spectrum Analyzer R&S FS300

DS H01 DIGITAL SYNTHESIZER MODULE SYSTEM SOLUTIONS. Features Applications 174 x 131 x 54 mm. Technical Description

Models 296 and 295 combine sophisticated

WaveStation Function/Arbitrary Waveform Generators

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

Signal Forge. Signal Forge 1000 TM Synthesized Signal Generator. Flexible Design Enables Testing of RF and Clock-driven Systems.

Model MHz Arbitrary Waveform Generator Specifications

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

Agilent 81180A Arbitrary Waveform Generator

Chapter 6 Specifications

Maximum output frequency:160 MHz, 100 MHz, 60 MHz 500MSa/s sample rate, 14 bits vertical resolution Dual Channel Outputs With Identical Performance

2.9GHz SPECTRUM ANALYZER

AFG-2100/2000 Series Arbitrary Function Generator. New Product Announcement

PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet

This section lists the specications for the Agilent 8360 B-Series. generators, Agilent Technologies has made changes to this product

Signal Forge 2500M Frequency Expansion Module. 1.5 GHz to 2.6 GHz. User Manual

Metrix Electronics Ltd Tel: +44 (0)

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Model 865-M Wideband Synthesizer

Signal Forge 1800M Frequency Expansion Module. 1.0 GHz to 1.8 GHz. User Manual

AFG-2100/2000 Series Arbitrary Function Generator. New Product Announcement

Function/Arbitrary Waveform Generator

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

Spectrum Analyzers U3771/3772. Handling frequencies of up to 43 GHz!! Our new microwave spectrum analyzer, ideal for field use, is now available.

Function/Arbitrary Waveform Generator

Function Generator Guide Tektronix AFG3102

GPS10RBN - 10 MHz, GPS Disciplined Rubidium Frequency Standard

GFT1504 4/8/10 channel Delay Generator

Signal Forge. Signal Forge 1000 TM Synthesized Signal Generator. Digital and RF Tester with 1 GHz Range. Key Features

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

MODEL AND MODEL PULSE/PATTERN GENERATORS

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz

AFG-2100/2000 Series Arbitrary Function Generator. New Product Announcement

OPTICAL MEASURING INSTRUMENTS. MS9710B 0.6 to 1.75 µm GPIB OPTICAL SPECTRUM ANALYZER

Synthesized Function Generators DS MHz function and arbitrary waveform generator

RF Signal Generator RIGOL TECHNOLOGIES, INC.

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

MODELS 5251/ MS/s PXIBus / PCIBus Arbitrary Waveform / Function Generators

IZT R3600. Product Brochure. Version 1.1

Agilent ESA-L Series Spectrum Analyzers

Datasheet RS Pro Arbitrary Waveform Generator 40MHz RS Stock Number : ENGLISH

MODELS WW5061/2. 50MS/s Single/Dual Channel Arbitrary Waveform Generators

DSA700 Series Spectrum Analyzer

Technical Datasheet UltraScope USB

Arbitrary/Function Generator AFG1000 Series Datasheet

Model 865-M Wideband Synthesizer

Spectrum Analyzers 2680 Series Features & benefits

Transcription:

High-speed programmable attenuator MAT800 Windows98/Me/2000/XP/Vista/7(32bit) correspondence GP-IB, RS-232C and software for making attenuation program are standard accessories. Optimum for evaluation of communication quality of such wireless communication equipments as W-CDMA, CDMA, GSM, PDC, PHS, ETC, wireless LAN and Bluetooth. MAT800 is a multi-functional and all-out programmable attenuator that is capable of controlling the attenuation of microwave signal at an ultra-high speed. Features 1. The arbitrary attenuation programs is possible 128kwords built-in program memory Maximum 2µs switching (readout) speed Three readout modes of FREE, BURST and GATE Setup of hold off period by the number of clocks or by time 2. The software for making attenuation program is a standard accessory 3. GP-IB and RS-232C are equipped as standard accessories 4. Five models are prepared for every frequency band model A : 1.5 to 4.5GHz model B : 3.0 to 9.0GHz model C : 4.5 to 13.5GHz model D : 1.95 to 5.85GHz model E : 750MHz to 2.25GHz 5. The maximum attenuation is 80dB 6. The minimum step size of attenuation is 0.05dB

3 2 1 6 5 4 8 7 12 11 10 9 1. Attenuation mode 2. Attenuation Select either manual setup or programmed setup. * Refer to "Setting of attenuation". Set the attenuation. It is valid in the manual mode. 0 to 80 db in 0.05 db steps. 3. Filter 4. Readout clock Select switching response time of attenuator. * Refer to "About a filter". Set readout clock of program memory. External clock and manual clock are available. 5. Program length 6. Program hold off period Set program memory length. 8 to 131,072 words in one word step. Set hold off period of program memory, that is, the time till the next readout is started. Perform setup by number of readout clocks or by time. * Refer to "Setting of attenuation". 7. Readout mode 8. Setup Set readout method of program memory from Free, Burst and Gate. * Refer to "Program readout mode". Set parameters of RS-232C or GP-IB. 9. External readout clock 10. Trigger input Connector for input of external clock for reading program memory. Connector for input of trigger signal for such read mode as Burst or Gate. * Refer to "Program readout mode". 11. SYNC output 12. Attenuator input / output A signal synchronized with the top address of the program memory is output. * Refer to "Program readout mode". SMA connector for attenuator input / output.

Setting of attenuation Two methods are available for setup of attenuation ; manual or program. Select one by "ATTEN MODE". Manual mode Set the attenuation using the rotary encoder on the front panel. Alternatively, perform setup from outside using RS-232C or GP-IB. The setup parameters in manual mode are attenuation and filter only. M A N U A L 2 3. 4 5 d B 3 0 µ s Program mode Read the memory storing attenuation data transferred from the computer. There are five parameters in the program mode ; readout clock, program length, hold-off period, readout mode and filter. P R G M 1 0 k H z L : 1 3 1 0 7 2 P : 6. 5 5 3 5 s F R E E 3 0 µ s The program readout period is the period from address 0 of the memory to address n (set by program length). The program length can be set between 8 and 131072 words in one word step. When the program is read up to address n, the attenuation data at address n is held for the hold off period (set by number of readout clocks or by time), and on termination of hold off period, the memory is read out from address 0 again. About a filter CR filter is inserted in the attenuation controlling line. Use when it is required to smooth the change at the moment of switching attenuation. However, it is necessary to pay attention to the relation with the readout clock. An appropriate filter value is normally 1 / 2 to 1 / 8 of the clock period.

The method of a program When it is necessary to use the program mode, input the program (waveform) on a Windows computer using "Software for making attenuation program", which is provided as a standard accessory. Then transfer this attenuation data to the memory of MAT800 using RS-232C or GP-IB. Readout clock, program length, hold off period, readout mode and filter are set from the computer. Of course it is possible to set by keys on the front panel. Connect external clock and trigger signal as required. Waveform creation 1. Standard waveforms input The nine types of standard waveforms are prepared. They are sine wave, triangle wave, square wave, ramp wave, sinx / X, (1-ε -ax ), ε -ax white noise and DC. 2. Straight line input Two specified points are linked together by means of a straight line. 3. Arithmetic calculation input A waveform is created by arithmetic calculation of addition, subtraction, clipping, absolute, mirror, smoothing, resize and offset. 4. One-point input A waveform is created through input of one point at a time. Waveform editing and file management Waveform editing and file management may be performed using CUT, COPY, PASTE and UNDO.

Program readout mode Three program readout modes are available ; Free, Burst and Gate. Readout is executed regardless of the trigger signal in the Free mode. In the Burst mode, the readout of program memory is started at the rising edge of the trigger signal, the attenuation data of the terminating address is held until the next activation. Therefore, setup of the hold off period is not permitted in the Burst mode. In the Gate mode, one set of the readout of program memory and hold off period is repeated while the trigger signal is of a high level. The last attenuation data is held when the trigger signal goes down to a low level and then address n of program memory is read out. Application - wireless communication quality test by changing transmission power With wireless communication equipments, LTE, W-CDMA, CDMA, GSM, PHS, ETC/DSRC, Wireless LAN and Bluetooth, the transmission power changes due to obstacles and multi-paths besides theoretical space losses, when the radio wave is transmitted through the space. This changing pattern can be simulated using MAT800 and the communication quality can be evaluated. This changing pattern can be easily created using "Software for making attenuation program". It will be very convenient if our "Shielding box ME8661A" is used for this test.

Specification model A model B model C Frequency range 1.5 to 4.5GHz 3.0 to 9.0 GHz 4.5 to 13.5GHz VSWR Insertion loss (0dB setting) < 1.5 @ 2 to 4GHz < 2.0 @ 1.5 to 4.5GHz < 2.7dB @ 2 to 4GHz < 2.9dB @ 1.5 to 4.5GHz model D < 1.7 @ 4 to 8GHz < 2.2 @ 3 to 9GHz < 3.5dB @ 4 to 8GHz < 3.8dB @ 3 to 9GHz model E Frequency range 1.95 to 5.85GHz 750MHz to 2.25GHz VSWR Insertion loss (0dB setting) < 1.6 @ 2.6 to 5.2GHz < 2.1 @ 1.95 to 5.85GHz < 2.8dB @ 2.6 to 5.2GHz < 3.3dB @ 1.95 to 5.85GHz < 1.5 @ 1 to 2GHz < 2.0 @ 0.75 to 2.25GHz < 2.3dB @ 1 to 2GHz < 2.6dB @ 0.75 to 2.25GHz < 1.8 @ 6 to 12GHz < 2.2 @ 4.5 to 13.5GHz < 3.8dB @ 6 to 12GHz < 4.8dB @ 4.5 to 13.5GHz Attenuator Setting range Setting resolution Accuracy (at center of frequency range and +10dBm input) Impedance Filter Maximum input level Input damage level Input / output connector Readout clock input Input level Maximum frequency Input impedance Minimum pulse width Input damage level Connector Trigger input Input level Input impedance Minimum pulse width Input damage level Connector SYNC output Output level Rise / Fall time Output impedance Connector 0 to 80dB less than 0.05dB less than ±0.5dB @ 0 to 10dB less than ±0.8dB @ >10 to 30dB less than ±1.0dB @ >30 to 50dB less than ±1.5dB @ >50 to 64dB less than ±2.0dB @ >64 to 74dB less than ±3.0dB @ >74 to 80dB 50ohm nominal 1µs to 3ms, 1-3 step 100mW @ CW or peak power 0.8W @ average power 20W @ peak power of 1µs pulse SMA TTL level 500kHz 10kohm ±5% more than 200ns (both of high and low) ±20V (DC + ACpeak) max BNC TTL level 10kohm ±5% more than 1µs ±20V (DC + ACpeak) max BNC TTL level less than 100ns approx. 100ohm BNC

Functions Attenuation mode Program mode Program length Readout clock Internal clock External clock Manual clock Hold off period Clock setting Time setting Read mode Backup of program Manual and Program 8 to 131072words, (available for setting in one word step) 100Hz to 500kHz, 1-2-5 step DC to 500kHz Due to pressing ENTER key 0 to 65535 clocks of readout clock (available for each clock) 0 to 6.5535sec (by 100µs step) Free, Burst, Gate Program data is automatically saved when turning off. Software for making attenuation program Effective OS Making waveform Standard waveform Waveform type Parameter Straight line Calculation One point input Editing of waveform File Windows 98 / Me / 2000 / XP / Vista / 7(32bit) Sine, Triangle, Square, Ramp, sinx / X, (1-ε -ax ), ε -ax, White noise and DC Data size, Attenuation (except DC), Offset, Cycle (except White noise and DC), Phase ( ) (except White noise and DC), Duty ratio (%) (only Square wave), Zero cross (only sinx / X), Attenuation ratio ( (1-ε -ax ) and ε -ax ) Link two points with line +, -,, Clipping, Absolute, Mirror, Smoothing, Resize, Offset Input each point Cut, Copy, Paste, Undo, Delete New, Open, Close, Save, Save as, Data import, Data export, Print, Printer setup, Transmit, Exit Others Display Interface RS-232C Baud rate GP-IB Address LCD (20characters 2columns) Standard Accessory 2,400 to 57,600 Standard Accessory 0 to 30

General Operating temperature Operating humidity Storage temperature Power Supply Weight Dimensions Standard accessories 0 to 40 C (Guaranteed at 23 ±5 C) less than 40 C / 80%RH (Guaranteed at less than 28 C / 80%RH) -10 to +60 C / less than 80%RH 90 to 132VAC / 180 to 250VAC (selectable by a switch located on rear panel) approx. 4.5kg 260 (W) 115 (H) 360 (D) mm (excluding projections) Instruction manual (1pc), Power cable (1pc), Fuse (1pc), FD for making attenuation program (1pc), RS-232C cable (1pc) Optional GP-IB cable Microwave coaxial cable Microwave coaxial cable Microwave coaxial cable Fixed microwave attenuators 50 ohm termination (2m) (0.5m) (3m) (4m) (1 to 10, 12, 13, 15, 20dB) (SMA) MICRONIX Corporation receives the right to make changes in design, specification and other information without prior notice.