OVA-50 Optical Variable Attenuator User s Manual

Similar documents
SPM-50 RF Spectrum Power Meter PC Software User Manual

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Pro. SimpliFiber. Getting Started Guide. Optical Power Meter and Fiber Test Kits

InsuLogix T Portable One Channel Temperature Measurement System Manual

USER MANUAL OLS-100 Optical Light Source

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

INSTRUCTION MANUAL INF Fax: (503)

Dawson DSM150. Digital Light Meter User s Manual

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Q-SERIES. Optical. QFQR 200A-04 Series Return Path Optical Receiver. Installation & Operation Manual

Beaming Optical Length Tester (BOLT)

2015 RIGOL TECHNOLOGIES, INC.

HFC. Enhance. QFHPN High Power Optical Node with AGC Installation & Operation Guide

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

DS1000E, DS1000D Series Digital Oscilloscope

INSTRUCTION MANUAL LKG

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

Model 4007DDS. 7 MHz Sweep Function Generator

FastGene Blue White LED Tab Catalogue Number FG-12

DC155 Digital Visualizer. User Manual

PULSE OXIMETRY SIMULATOR

Model UT511 OPERATING MANUAL

MODEL 320A 3 GHz O/E RECEIVER. User s Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

TIA-527 Balanced Optical/Electrical Converter. Operating Instructions

FiberLink 4040 Series

User s Guide. Model MA A AC Mini Clamp-on Meter

Power Measurment. Hand-held Design Brings Peak Performance to the Field. Introduction. Features

MAGNETIC FIELD METER Operator s Manual

PI-150 Broadband Power Indicator

Pipe Laser Model No Instruction Manual

312, 316, 318. Clamp Meter. Users Manual

Operator s Manual. PP016 Passive Probe

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

User s Guide. 400A AC/DC Clamp Meter. Model MA220

TIA-2000 Optical/Electrical Converter. Operating Instructions

ELECTROSURGICAL UNIT ANALYZER

Dawson DDM190. Digital Multimeter User s Manual

PI-10 Broadband Power Indicator

Operating Instructions

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

CCR24T CCR24R. User s Guide WIRELESS TRANSMITTER SYSTEM WARRANTY SERVICE CARD WARRANTY CARD

TIA-4000 Optical/Electrical Converter. Operating Instructions

OP735. Benchtop Optical Power Meter Instruction Manual

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

Geotagger N3. User Manual (V1.0) Revised by Geosolve.be (Pol F. Gillard) with personal updates and help. Solmeta Technology Co.

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

TIA-1200 Optical/Electrical Converter. Operating Instructions

Model 7000 Low Noise Differential Preamplifier

Optical Transmitter RF-T860/24. Installation & Operation Manual. Caution

MODEL W Power Amplifier

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Convey-All BTS 550 Wireless Seed Tender Remote Users Manual

200Amp AC Clamp Meter + NCV Model MA250

Measurement solutions for single-mode fibers

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

STAFF User Manual. Manual Part #

Using the USB Output Port to Charge a Device

Geo EasyTrack Auto Tracking System for Line Lasers

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

SlimScan BT Users Manual

Keychain Radio Remote Control System

DDM350 Pen-Type Digital Multimeter User s Manual

32 CHANNEL SELECTABLE CH MHZ DOWN VOLUME

Opus 21 s80 Integrated Amplifier Owner's Manual

DC162 Digital Visualizer. User Manual. English - 1

DAC6820N (4) Balanced/unbalanced. AES to Analog Audio Converter USER MANUAL

CBA 400M MHZ to 400 MHZ

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

MAGNETIC FIELD METER Operator s Manual

Signal Analysis Measurement Guide

AH Auto-Darkening Welding Helmet User Manual. Made in China

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

8472B Crystal Detector. Operating and Service Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual

3x Magnification. Digital Zoom to 6x. CAUTION: Do not point Infrared Emitter directly into eye at close range.

MODEL 3810/2 Line Impedance Stabilization Network

5 Mbit/s Repeater Carrierband to Single-mode Fiber Optic

Broadband Step-Up Transformer. User Manual

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

FastGene FAS-V Imaging System. Catalogue Number GP-FAS-V

TIA-500 Optical/Electrical Converter Operating Instructions

Signal Generator Extension Modules Operational Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Safety Information (Attach ed at the upper cover of t his product) Safety Warning (Attached on the output fiber isolato r & collimator) Figure 1 Laser

Firmware Version d & higher Installation & Operation

Current Probe Fixture Instruction Manual

Infrared Gun. Perfect For. Easy To Use. Features. Get Professional Results Every Time! Battery Installation. Model: IN1022

INSTRUCTION MANUAL MODEL SAS RS-7 LASER DISTANCE METER

Model UT20B: OPERATING MANUAL Table of Contents (1)

FluorCam PAR- Absorptivity Module & NDVI Measurement

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

2100L Broadband Power Amplifier

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

Transcription:

OVA-50 Optical Variable Attenuator User s Manual Shineway Technologies, Inc. All rights reserved.

Safety Instructions The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personnel injury. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met. The CAUTION sign denotes a hazard. It calls attention to an operating procedure, or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or the entire product. Do not proceed beyond a CAUTION sign until the indicated conditions are fully understood and met. The NOTE sign information that may be beneficial during the use and maintenance of the instrument. Users should avoid looking directly into the optic output of OVA-50. And the use of microscope or magnifier should also be avoided, for the use of such devices can focus a highly intense beam onto the retina, which may result in permanent eye damage Battery: OVA-50 battery type is lithium battery. Do not take battery out without technical staff s assistance. Do not expose battery to fire or intense heat. Do not open or mutilate battery. Avoid touching the electrolyte in the battery, which is corrosive and may cause injuries to eyes, skin or damage to clothes. External Power Supply: Power Adaptor, 5V DC/750mA Laser Radiation: To avoid serious eye injury, never look directly into the optical outputs of fiber optic network equipment, test equipment, patch cords, or test jumpers. Always avoid looking directly into the optical output port, Shineway Technologies, Inc. - ii -

when the instrument is working Always replace protective dust cap on the detector port when the instrument is not in use. Always avoid looking directly at unconnected end of optic fiber in testing and make the unconnected end pointing at a non-reflective object. Shineway Technologies, Inc. - iii -

Contents Safety Instructions... ii 1. General Information... 1 1.1 Scope of this Manual... 1 1.2 Unpacking and Inspection... 1 1.3 Introduction... 1 2. Basic Operation... 3 2.1 Foreword... 3 2.2 Instrument Details... 3 2.2.1 External Interfaces... 4 2.2.2 Keypad Operation... 4 2.2.3 Indicator... 5 2.3 Use of Battery... 5 2.4 Connector Cleaning... 5 3. Operation... 6 3.1 Power On... 6 3.2 Absolute Attenuation... 6 3.3 Relative Attenuation... 7 3.4 Program... 8 3.5 Output Power Control... 9 4. Calibration... 10 4.1 Optical Interface Cleaning... 10 4.2 Calibration Requirements... 10 5. Specifications... 11 6 Warranty Information... 12 6.1 Warranty Period... 12 6.2 Exclusion... 12 6.3 Warranty Registration... 12 6.4 Returning Instrument... 12 6.5 Contact Customer Service... 13 Shineway Technologies, Inc. - iv -

1. General Information 1.1 Scope of this Manual Thank you for purchasing ShinewayTech instrument. Please read this manual carefully before using ShinewayTech fiber optic instrument. Always be aware of the Warning and Caution sign appearing throughout this manual. This manual contains the information necessary for proper operation and maintenance of ShinewayTech instrument, troubleshooting instructions as well as information regarding maintenance services. All ShinewayTech instruments are carefully assembled and undergo rigorous mechanical, electrical, and optical inspection prior to shipment. Beside the instrument, the package also includes a lithium battery pack, a charging/data transfer cable, a power adapter, a FC/PC flange and this user's manual. For detailed information, please refer to the packing list. Upon receiving the instrument, please check for any obvious signs of physical damage that may have occurred during shipment. Report any damage to the shipping agent or the representative of Shineway Technologies Inc. immediately. Retain the original packing materials in case reshipment is necessary. 1.2 Unpacking and Inspection This instrument has been carefully packed in accordance with standard shipping procedures. Examine the instrument for damage that may have occurred during shipment. If you find any damage or the instrument is not working, or if any of the following items are not included, please contact your representative of Shineway Technologies, Inc. If necessary, you may contact Shineway Technologies, Inc via this email: support@shinewaytech.com. 1.3 Introduction ShinewayTech OVA-50 Optical Variable Attenuator can precisely attenuate input optical signals at 1310/1490/1550/1625nm wavelengths and directly output defined stabilized Shineway Technologies, Inc. - 1 -

optical signals. OVA-50 is applicable in various testing situations: Network/BER testing Power meter calibration Link loss simulation Optical margin analysis Features: Attenuation range: 2.5-60dB Direct output power control Working modes: Output power control Absolute/relative attenuation setting Program (Preprogramming frequently-used attenuations) Adjust at step of 0.05/0.10/1.00/10.00 db PC control via USB Backlight Over 30 hours continuous operation Handheld, light and easy-to-use CE FCC certificates Direct Output Power Control Normal attenuator can only introduce and display an attenuation value, you need a separate power meter to measure or adjust the output power value of attenuated optical signal. Working like a combination of attenuator and power meter, OVA-50 Output Power Control mode enables direct setting of precise optical power level and can automatically stabilize output level without any interference by variations of input power. Program Mode User can preprogram frequently-used attenuations to reduce workload. Shineway Technologies, Inc. - 2 -

2. Basic Operation 2.1 Foreword This part introduces the basic operation on OVA-50. Specific operations of each type instrument are elaborated in Chapter 3 of this manual. Please read this manual carefully for optimal operation. If you encounter any problems during operation, you are welcome to contact the technical staff of our company or representatives. 2.2 Instrument Details 1 2 Shineway Technologies, Inc. - 3 -

2.2.1 External Interfaces 1. Optical Input OVA-50 is available with FC connector (Interchangeable SC/ST). 2. USB Power /Data Port OVA-50 can be charged by external power adapter (5V DC, 750mA). 2.2.2 Keypad Operation Power on/off Toggle between calibrated wavelengths Reset to minimum attenuation value Short press to toggle between working modes: Absolute attenuation, Relative attenuation, Program & Output power control; Long press to enable/disable Auto Off Change attenuation value Toggle between attenuation stepping; Shift digit positions Enter functional interface; Confirm Turn backlight on/off; Long press to adjust contrast Shineway Technologies, Inc. - 4 -

2.2.3 Indicator Charging indicator 2.3 Use of Battery OVA-50 works on lithium battery, please make sure battery is mounted properly before use. When battery is low, low battery indicator will appear on LCD. You can still use OVA-50 as long as its display on LCD is identifiable. Please charge as soon as possible when battery is low to ensure accurate measurement. Please take out the battery if OVA-50 is not in use for a long time. 2.4 Connector Cleaning Please follow the instructions below when cleaning: Turn off the instrument before cleaning. Non-compliant operation may result in hazardous radiation exposure. Turn off laser source before cleaning optical interface. Always avoid looking directly into the optical output port when the instrument is working, laser is invisible and can cause serious eye damage. Disconnect instrument from power supply before cleaning to prevent electric shock. Do not install unauthorized parts or make unauthorized adjustments on instrument. Please consult qualified professional about maintenance and repair services. Always clean optical connector before using optical power meter to ensure accurate measurement. Clean the optical connector gently with cleaning swab. Inappropriate maintenance may result in low performance or error: Distance error increases; Linearity error; Extra optical power attenuation; Received optical power is beyond normal range. Shineway Technologies, Inc. - 5 -

3. Operation 3.1 Power On Press [On/Off] button and loading screen appears, see Figure 3.1. ShinewayTech OVA-50 Version 1.00 Figure 3.1 Then it enters default interface: Absolute attenuation setting, see Figure 3.2. :0.05 1550 nm 1.00 db Figure 3.2 3.2 Absolute Attenuation It is default to enter absolute attenuation mode when OVA-50 powers on; or press button to absolute attenuation mode, see Figure 3.2; In absolute attenuation mode, press button to toggle between the steps of 0.05/0.10/1.00/10.00; press or button to adjust absolute attenuation value. Press button to insertion loss setting interface, see Figure 3.3. Shineway Technologies, Inc. - 6 -

:0.05 1550 nm 1.00 db SET INS Figure 3.3 Press button to toggle between the steps of 0.05/0.10/1.00/10.00; press or button to adjust insertion loss value; Press the initial interface of absolute attenuation mode. button to confirm and return to Note: 1. Function shown in Figure 3.3 is mainly applied before testing to set the insertion loss for jumper fiber and the instrument to ensure accurate attenuation calculation. 2. Once the insertion loss value is set, press button and OVA-50 will save the value as default minimum attenuation value. 3.3 Relative Attenuation Press button to relative attenuation value mode, see Figure 3.4; :0.05 1550 nm REF: 10.00 0.00 db Figure 3.4 Press button to toggle between the steps of 0.05/0.10/1.00/10.00; Press or button to adjust relative attenuation value, then real attenuation value equals set reference attenuation value (See Figure 3.4: REF: 10.00 ) plus set relative attenuation value; In the interface of Figure 3.4, press button to interface shown in Figure 3.5 and press Shineway Technologies, Inc. - 7 -

or button to adjust relative attenuation value; Press button to confirm and return to the initial interface of relative attenuation mode. :0.05 1550 nm 10.30 db SET ATTRef Figure 3.5 3.4 Program Press button to program attenuation mode, see Figure 3.6 :0.05 1550 nm 10.00 db 0123456789 Figure 3.6 There are 10 preset attenuation values in the program attenuation mode; black arrow indicates the currently selected preset. Press or button to select the preset attenuation value. Press button, the black arrow on the top of the selected preset will blink, press or button to adjust the value of the current preset attenuation; Press button to toggle between the steps of 0.05/0.10/1.00/10.00; Press and return to the initial interface of program attenuation mode. button to confirm Shineway Technologies, Inc. - 8 -

3.5 Output Power Control Press button to output power control mode, see Figure 3.7. 1550 nm - 15.00 dbm OUTPUT PWR Figure 3.7 Press button to enter output power setting interface, see Figure 3.8. 1550 nm - 15.00 dbm SET OUTPUT Figure 3.8 Press button to shift digit position of the output power value; Press or button to adjust the value of output power; Press return to the initial interface of output power control mode. button to confirm and Note: IN: XXXXXdBm will display when set value is equal or greater than input value, and OUT OF RANGE will display on the bottom of interface, and then the function is invalid. IN :-20.00dBm 1550 nm - 15.00 dbm OUT OF RANGE Shineway Technologies, Inc. - 9 -

4. Calibration 4.1 Optical Interface Cleaning Optical interface must be always kept clean. Always put protective dust cap on when the unit is not in use, and keep the protective dust cap clean. 4.2 Calibration Requirements Calibration of the instrument is recommended every 3 years. Please contact our representatives or customer service centers for proper calibration. Shineway Technologies, Inc. - 10 -

5. Specifications Model OVA-50 Wavelength Range 1260~1650nm Calibrated Wavelengths 1310/1490/1550/1625nm Fiber Type 9/125μm Singlemode Attenuation Range 2.5-60dB Insertion Loss <2.5dB Max Input Power +21dBm Output Power Range (1) +18 ~ -55 dbm Setting Time <3s Display Resolution 0.01dB Attenuation Accuracy ±0.25dB @+25 ( Output power control mode) Repeatability ±0.25dB @+25 Return Loss 55dB Connector FC/PC (Interchangeable SC,ST) Power Saving Auto-off after 5 minutes idle Backlight Yes Power Supply Li-Ion Battery/AC Adaptor Battery Life Continuous operation >30hours Weight 345g (0.7 lbs) Dimensions (H W T) 177 80 44mm (6.97 3.15 1.73 inch) Note: (1) Input power level should be at least 3 db higher than selected output power level; Input power variations in frequency range <0.5 Hz * Specifications subject to change without notice Shineway Technologies, Inc. - 11 -

6 Warranty Information 6.1 Warranty Period All ShinewayTech products are warranted against defective material and workmanship for a period of one (1) year from the date of shipment to the original customer. Any product found to be defective within the warranty period would be repaired or replaced by Shineway Technologies Inc free of charge. In no case will Shineway Technologies, Inc liabilities exceed the original purchase price of the product. 6.2 Exclusion The warranty on your equipment shall not apply to defects resulting from the following: Unauthorized repair or modification Misuse, negligence, or accident Shineway Technologies, Inc. reserves the right to make changes to any of its products at any time without having to replace or change previously purchased units. 6.3 Warranty Registration A warranty registration card is included with the original shipment of equipment. Please take a few minutes to fill out the card and mail or fax it to the local Customer Service Center of Shineway Technologies, Inc. for your product warranty activation. 6.4 Returning Instrument To return instrument for yearly calibration or other purposes, please contact the local Customer Service Center of Shineway Technologies, Inc to obtain additional information and a RMA (Return Materials Authorization) number. And describe brief reasons for the return of the equipment to help us offer you efficient services. To return the instrument in the case of repair, calibration or other maintenance, please note the following: Shineway Technologies, Inc. - 12 -

Be sure to pack the instrument with soft cushion like Polyethylene, so as to protect the shell of the instrument. Please use the original hard packing box. If you use other packing material, please ensure at least 3 cm soft material around the instrument. Be sure to correctly fill out and return the warranty registration card, which should include the following information: company name, postal address, contact, phone number, email address and problem description. Be sure to seal the packing box with exclusive tape. Be sure to ship to your representative or agent of Shineway Technologies, Inc in a reliable way. 6.5 Contact Customer Service Please check our web site (www.shinewaytech.com) for updates to this manual and additional application information. If you need technical or sales support, please contact local Shineway Technologies Customer Service. Shineway Technologies (China), Inc.: Address: Fl.7, Zhongtai Plaza, No.3 Shuangqing Rd, Haidian District, Beijing, China Postal code: 100085 Tel: +86-10-62953388 Fax: +86-10-62958572 Email: support@shinewaytech.com WEB: www.shinewaytech.com THANK YOU FOR CHOOSING SHINEWAY TECHNOLOGIES! DOC.P/N:MAN-OVA-EN. V300. 05/10 Shineway Technologies, Inc. - 13 -

Shineway Technologies, Inc. - 14 -