Mixed Conduction Mode Control for Inductor Minimization in Grid-Tied Inverter

Similar documents
Current THD Reduction for High-Power-Density LCL-Filter-Based. Grid-Tied Inverter Operated in Discontinuous Current Mode

Passive-Damped LCL Filter Optimization for Single-Phase Grid-Tied Inverters Operating in both Continuous and Discontinuous Current Mode

Discontinuous Current Mode Control for Minimization of Three-phase Grid-Tied Inverter in Photovoltaic System

A Unique SEPIC converter based Power Factor Correction method with a DCM Detection Technique

Highly-Reliable Fly-back-based PV Micro-inverter Applying Power Decoupling Capability without Additional Components

Improvement of Light Load Efficiency for Buck- Boost DC-DC converter with ZVS using Switched Auxiliary Inductors

RECENTLY, the harmonics current in a power grid can

RECENTLY, energy sources such as wind power systems,

Application of GaN Device to MHz Operating Grid-Tied Inverter Using Discontinuous Current Mode for Compact and Efficient Power Conversion

A Novel Control Method Focusing on Reactive Power for A Dual Active Bridge Converter

Linear Transformer based Sepic Converter with Ripple Free Output for Wide Input Range Applications

Output Voltage Correction of an Induction Motor Drive Using a Disturbance Observer with Speed Sensor-less Vector Control Method

Student Department of EEE (M.E-PED), 2 Assitant Professor of EEE Selvam College of Technology Namakkal, India

Neuro Fuzzy Control Single Stage Single Phase AC-DC Converter for High Power factor

Bridgeless Cuk Power Factor Corrector with Regulated Output Voltage

Soft-Switching Active-Clamp Flyback Microinverter for PV Applications

Bidirectional Ac/Dc Converter with Reduced Switching Losses using Feed Forward Control

Simulation Of A Three Level Boosting PFC With Sensorless Capacitor Voltage Balancing Control

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

International Journal of Engineering Science Invention Research & Development; Vol. II Issue VIII February e-issn:

Novelty Technique for Power factor Improvement by a Single phase Rectifier

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

A HIGH RELIABILITY SINGLE-PHASE BOOST RECTIFIER SYSTEM FOR DIFFERENT LOAD VARIATIONS. Prasanna Srikanth Polisetty

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Power Factor Correction of LED Drivers with Third Port Energy Storage

CHAPTER 3 MAXIMUM POWER TRANSFER THEOREM BASED MPPT FOR STANDALONE PV SYSTEM

PERFORMANCE ANALYSIS OF SOLAR POWER GENERATION SYSTEM WITH A SEVEN-LEVEL INVERTER SUDHEER KUMAR Y, PG STUDENT CHANDRA KIRAN S, ASSISTANT PROFESSOR

Experimental Verification of High Frequency Link DC-AC Converter using Pulse Density Modulation at Secondary Matrix Converter.

REDUCED SWITCHING LOSS AC/DC/AC CONVERTER WITH FEED FORWARD CONTROL

Current Rebuilding Concept Applied to Boost CCM for PF Correction

A Predictive Control Strategy for Power Factor Correction

Analysis of Utility Interactive Photovoltaic Generation System using a Single Power Static Inverter

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR

DESIGN OF SENSORLESS CAPACITOR VOLTAGE BALANCING CONTROL FOR THREE-LEVEL BOOSTING PFC WITH PV SYSTEM

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

Matlab Simulation of a High Step-Up DC-DC Converter for a Micro grid Application

A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering Function

Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

A Pv Fed Buck Boost Converter Combining Ky And Buck Converter With Feedback

Design and Simulation of New Efficient Bridgeless AC- DC CUK Rectifier for PFC Application

An Isolated DC-AC Converter Module Integrating Renewable Energy Source and Energy Storage for Cascaded Inverter

Multi-Modular Isolated Three-Phase AC-DC Converter for Rapid Charging with Autonomous Distributed Control

A Novel Cascaded Multilevel Inverter Using A Single DC Source

THE converter usually employed for single-phase power

Grid-Tied Interleaved Flyback Inverter for Photo Voltaic Application

A Resistance Emulation Technique to Improve Efficiency of a PWM Adjustable Speed Drive with Passive Power Factor Correction

A NOVEL BUCK-BOOST INVERTER FOR PHOTOVOLTAIC SYSTEMS

CAPACITOR VOLTAGE BALANCING IN SINGLE PHASE SEVEN-LEVEL PWM INVERTER

A high Step-up DC-DC Converter employs Cascading Cockcroft- Walton Voltage Multiplier by omitting Step-up Transformer 1 A.Subrahmanyam, 2 A.

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

MODERN switching power converters require many features

I. INTRODUCTION. 10

Index Terms: Single Stage, Buck-Boost Inverter, Low-Cost,Grid-Connected, PV system, Simple-Control, DCM, MPPT.

International Journal of Engineering Research and General Science Volume 3, Issue 4, July-August, 2015 ISSN

A New Three-Phase Interleaved Isolated Boost Converter With Solar Cell Application. K. Srinadh

IEEE Transactions On Circuits And Systems Ii: Express Briefs, 2007, v. 54 n. 12, p

DIGITAL controllers for switch-mode power supplies have

Fundamentals of Power Electronics

Levels of Inverter by Using Solar Array Generation System

SINGLE STAGE SINGLE SWITCH AC-DC STEP DOWN CONVERTER WITHOUT TRANSFORMER

Zero Voltage Switching Scheme for Flyback Converter to Ensure Compatibility with Active Power Decoupling Capability

ISSN Vol.07,Issue.06, July-2015, Pages:

A New Single Switch Bridgeless SEPIC PFC Converter with Low Cost, Low THD and High PF

TO LIMIT degradation in power quality caused by nonlinear

Grid connected Boost-Full-Bridge photovoltaic microinverter system using Phase Opposition Disposition technique and Maximum Power Point Tracking

Implementation of Voltage Multiplier Module in Interleaved High Step-up Converter with Higher Efficiency for PV System

VERY HIGH VOLTAGE BOOST CONVERTER BASED ON BOOT STRAP CAPACITORS AND BOOST INDUCTORS USED FOR PHOTOVOLTAIC APPLICATION USING MPPT

High Performance Parallel Single-Phase Converter Reconfiguration for Enhanced Availability

Single switch three-phase ac to dc converter with reduced voltage stress and current total harmonic distortion

Research and design of PFC control based on DSP

SINGLE STAGE LOW FREQUENCY ELECTRONIC BALLAST FOR HID LAMPS

Department of EEE, SCAD College of Engineering and Technology, Tirunelveli, India, #

High Voltage-Boosting Converter with Improved Transfer Ratio

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

Fuzzy Controlled Capacitor Voltage Balancing Control for a Three Level Boost Converter

Combination of Input/Output Control using Matrix Converter for Islanded Operation for AC generator

NOVEL TRANSFORMER LESS ADAPTABLE VOLTAGE QUADRUPLER DC CONVERTER WITH CLOSED LOOP CONTROL. Tamilnadu, India.

An Interleaved Flyback Inverter for Residential Photovoltaic Applications

ABSTRACT I. INTRODUCTION

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

High Power Factor Bridgeless SEPIC Rectifier for Drive Applications

A THREE PHASE GRID CONNECTED PHOTOVOLTAIC INVERTER WITH DC CURRENT SUPPRESSION FEATURE

CHAPTER 3. SINGLE-STAGE PFC TOPOLOGY GENERALIZATION AND VARIATIONS

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

A PV Based Thirteen Level Inverter For Microgrid Mr.K.sairam, M. Saritha Reddy, K.S. Mann, M. Narendra Kumar

An Implementation of Grid Interactive Inverter with Reactive Power Support Capability for Renewable Energy Sources

A Single Switch DC-DC Converter for Photo Voltaic-Battery System

Electromagnetic Compatibility and Better Harmonic Performance with Seven Level CHB Converter Based PV-Battery Hybrid System

Improved Modulated Carrier Controlled PFC Boost Converter Using Charge Current Sensing Method

Asymmetrical Interleaved DC/DC Switching Converters for Photovoltaic and Fuel Cell Applications Part 1: Circuit Generation, Analysis and Design

Review and Analysis of a Coupled Inductor Based Bidirectional DC-DC Converter

IT is well known that the boost converter topology is highly

A Critical-Conduction-Mode Bridgeless Interleaved Boost Power Factor Correction

A DC DC Boost Converter for Photovoltaic Application

High Gain Step Up DC-DC Converter For DC Micro-Grid Application

Design and Simulation of FPGA Based Digital Controller for Single Phase Boost PFC Converter

11 LEVEL SWITCHED-CAPACITOR INVERTER TOPOLOGY USING SERIES/PARALLEL CONVERSION

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP(

Development of Inductive Power Transfer System for Excavator under Large Load Fluctuation

A NOVEL High Step-Up Converter with a Voltage Multiplier Module for a Photo Voltaic System

Transcription:

IEEE PEDS 7, Honolulu, USA 5 December 7 Mixed Conduction Mode Control for Inductor Minimiation in Grid-Tied Inverter Hoai Nam e, Jun-ichi Itoh Nagaoka University of Technology 63- Kamitomioka Town Nagaoka City, Niigata Prefecture, Japan Tel.: +8 / (58) 47.9533. E-Mail: lehoainam@stn.nagaokaut.ac.jp UR: http://itohserver.nagaokaut.ac.jp/itohlab/index.html Abstract This paper proposes a mixed-conduction-mode (MCM) current control for a grid-tied inverter operating in both continuous current mode (CCM) and discontinuous current mode (DCM) in order to minimie an interconnected inductor. In general, a low interconnected inductor value worsens disturbance suppression of current controller, and leads to an increase in grid current total harmonic distortion (THD). In DCM, the disturbance-to-current transfer function becomes nonlinear and the disturbances such as the dead time voltage error are effectively suppressed. Therefore, the grid-tied inverter operating in MCM can achieve a low grid current THD. However, another DCM nonlinearity occurs in the duty-tocurrent transfer function, which makes control gain characteristic in DCM completely different from that in CCM. Therefore, the DCM nonlinearity compensation is proposed by using duty at previous calculation. The validity of the proposed current control is confirmed with a -kw -kh prototype. Even when using the interconnected inductor with a normalied impedance of.6%, the grid current THD is reduced from 4.8% to.9% at rated load compared to the conventional CCM control. Furthermore, the inductor volume is reduced by 77.%, whereas the converter loss is reduced by 36.5%. Keywords Single-phase grid-tied inverter, Continuous current mode, Discontinuous current mode, Mixed conduction mode, Disturbance compensation. I. INTRODUCTION IN recent years, researches on photovoltaic system (PV) has attracted many attentions due to the increasing demand of renewable resources []-[3]. H-bridge inverters are usually used in the PV system in order to convert DC power from solar panel into AC power in the conventional AC single-phase grid. In such grid-tied inverters, C filters are generally employed between the inverter and the grid in order to suppress current harmonics and meet grid current harmonic constraints as defined by standards such as IEEE-59-99 [4]-[5]. This C filter, especially the interconnected inductor, accounts for a majority of the inverter volume [6]-[7]. By increasing switching frequency and reducing an inductor value, the interconnected inductor volume can be minimied. However, the grid-tied inverter generally operates in CCM, where the disturbance suppression performance worsens with the reduced inductor value. This leads to the increase in the grid current THD. In order to overcome this problem, a disturbance observer which is designed based on CCM transfer function is utilied. The disturbance observer can suppress the disturbance effects on the current control and allows the reduction of the inductor value. Nevertheless, this method requires high speed controllers such as, e.g. field-programmable gate array (FPGA), in order to estimate the rapidly-changing disturbances, e.g. the deadtime error voltage [8]. As another approach, the disturbance effects can be reduced by DCM. The ero-current interval in DCM introduces the nonlinearity into the disturbance-to-current transfer function, which effectively suppresses the disturbance effects such as the dead time voltage error. However, another nonlinearity occurs in the duty-to-current transfer function, which makes the current control gain in DCM completely different from that of CCM [9]-[]. A nonlinearity compensation has been proposed and effectively achieves the current command response as same as CCM []. Nevertheless, the proposed DCM current controller can be applied only in DCM, which implies that the grid-tied inverter has to operate in DCM over entire load range. This design significantly increases conduction loss of switching devices due to high current ripple of DCM at rated load. Therefore, many control methods which allow the inverter to operate in both CCM and DCM have been proposed to improve the conversion efficiency []-[4]. However, these MCM control method becomes dependent on the inductor value, which decays the robustness of the controller against the change of the inductor value [5]. This paper proposes a novel MCM current control for the grid-tied inverter operating in both CCM and DCM. The DCM nonlinearity in the disturbance characteristic is used to reduce the grid current THD, whereas the DCM nonlinearity in the duty-to-current transfer function is compensated by using the duty at the previous calculation period. Meanwhile, the current mode determination between CCM and DCM is accomplished by comparing the DCM duty and the CCM duty at the output of the controller. Thank to this method, the current feedback control is independent of the inductor value and can operate at any load condition. This paper is organied as follows: first the problems with the increasing grid current THD when the inductor value is reduced in CCM operation is explained. Next, two DCM nonlinearities are 978--59-364-6/7/$3. 7 IEEE

investigated when the power factor is lower than one in order to stably operate the grid-tied inverter at any load condition. Then the MCM current control for both CCM and DCM is proposed in order to obtain the low grid current THD with the small inductor value. Finally, the effectiveness of the proposed current control is confirmed experimentally with a -kw prototype. The comparisons of the grid current THD and the conversion efficiency are demonstrated. S W S W V d c i o u t C f f i g G r i d s i d e g II. PROPOSED MIXED CONDUCTION MODE CURRENT CONTRO A. Current Distortion in Conventional Continuous Current Mode Control Fig. indicates the circuit configuration of the singlephase grid-tied inverter. In this paper, a single-phase H- bridge inverter is applied due to its simplicity. The C filter connects the inverter to the grid in order to suppress the current harmonics of the inverter output current. Note that the grid has its own intrinsic inductor g, the value is different depending on the type and the condition of the grid. Fig. indicates the conventional CCM feedback current control block with a typical dead-time error voltage compensation. Note that the grid current i g and the grid voltage are assumed to be as same as and the voltage v Cf across the filter capacitor C f, respectively, because the cutoff frequency of the C filter is designed to be much higher than the bandwidth of the current control loop. The amplitude of the disturbance-voltage-to-current transfer function in CCM which is also entitled the gain of the disturbance response G dis_ccm is derived from Fig. and expressed as in G dis _ CCM n 4 n... (), n where is the inverter-side inductor value, is the disturbance angular frequency, and n are the damping factor and the angular frequency of the current controller, respectively. Fig. 3 depicts the gain of the disturbance response in CCM under different conditions of. Because G dis_ccm is inversely proportional to, the disturbance effects increase times when is reduced from p.u. to. p.u.. Consequently, this worsens the disturbance response. In general, when the typical dead-time error voltage compensation is applied with the high, the current distortion is effectively reduced. However, when is greatly reduced, only a small mismatch between the estimated and actual dead-time error voltage (v deadtime_est and v deadtime ) which is caused by such as the current detection delay, results in a high current distortion due to the greatly-increasing gain of the disturbance response G dis_ccm. Note that by increasing the angular frequency of the current controller n, the gain of the disturbance response G dis_ccm can be reduced, i.e. the current distortion can be reduced. However, a high bandwidth current control requires a high speed controller, which is an undesired solution. S W S W Fig.. Single-phase H-bridge grid-tied inverter with C filter. A singlephase H-bridge inverter is applied due to its simplicity, which is important for stability analysis and reliability design. i o u t _ a * i o u t _ a P I C o n t r o l l e r s i g n K p ( s T i + ) s T i V d c T d f s w C o n t r o l S y s t e m C i r c u i t V d c V d c s B. Compensation of Discontinuous-Current-Mode Nonlinearity in Duty-To-Current Transfer Function Fig. 4 indicates the grid-tied inverter operation under different conditions of the power factor. Fig. 4(a), (b) shows the relationship between the grid voltage and the output current of the inverter at the unity power factor and the power factor below one, respectively. Meanwhile, Fig. 4(c), (d) depicts the inverter operation mode and the output current waveform when the inverter operates in powering mode at interval ii in Fig. 4(b) and generation mode at interval i in Fig. 4(b), respectively. Note that the grid-tied inverter is operated in bipolar modulation in order to reduce common current, whereas the grid-side inductors g, f, and the filter capacitor C f are omitted due to the simplification. As shown in Fig. 4(a), the inverter operates in only the powering mode when the power factor is unity. On the other hand, the in- D v d e a d t i m e _ e s t e - s T v d i s v d e a d t i m e i o u t _ a Fig.. Conventional CCM feedback current control block with typical dead-time error voltage compensation. When the interconnected inductor is minimied by reducing the inductor value, the inverter become more vulnerable to the disturbances, i.e. the increase in the disturbance gain. D i s t u r b a n c e r e s p o n s e g a i n G d i s _ C C M [ d B ] - - 4-6 I n c r e a s e d B ( t i m e s ) o w i m p e d a n c e o f. p. u. H i g h i m p e d a n c e o f. p. u. - 8. p. u. e q u a l s 5 % o f t h e t o t a l i n v e r t e r i m p e d a n c e. -. D i s t u r b a n c e f r e q u e n c y f [ H ] Fig. 3. Disturbance response gain in CCM. The minimiation of the inductors in CCM is limited by the increase in the disturbance gain.

Intervals: ii iv > > * > Powering < < * > Powering (a) Grid voltage and output current at unity power factor Mode Mode Intervals: i ii iii iv i > < * < Generation > < > > * > * < Powering Generation < < * > Powering (b) Grid voltage and output current at power factor below one Mode Mode Inductor current Current peak i peak Average current D T sw D T sw D 3 T sw T sw D T sw D T sw D 3 T sw T sw Inductor current Average current Current peak i peak (c) Inverter operation mode and output current waveform (d) Inverter operation mode and output current waveform in powering mode (cf. interval ii of Fig. 4(b)) in generation mode (cf. interval i of Fig. 4(b)) Fig. 4. Grid-tied inverter operation under different conditions of power factor. Different from the CCM operation, the inverter operation mode in DCM depends on the relationship between the grid voltage and the output current of the inverter, i.e. the powering mode or the generation mode. This is because the ero-current interval introduces nonlinearities into the DCM operation. verter alternatively operates in the powering mode and the generation mode when the power factor is below one as shown in Fig. 4(b). Consequently, as shown in Fig. 4(c), (d), the applying order of mode and mode in the powering mode is flipped compared to that in the generation mode. The reason is that different from the CCM operation, the inverter operation mode in DCM depends on the relationship between the grid voltage and the output current of the inverter, i.e. the powering mode or the generation mode. Therefore, in order to control the grid-tied inverter in DCM, the circuit model has to be analyed in each the powering mode and the generation mode. For the sake of brevity, only the operation in the powering mode is discussed in the following. However, the operation in the generation mode is derived analogously. Considering the inverter operation and the output current waveform in the power mode shown in Fig. 4(c) (cf. the interval ii in Fig. 4(b)), D, D and D 3 denote the duties of the first, the second and the ero-current interval. The equation based on the average model of the inverter shown in Fig. 4(c) is given by () [9]-[], V D ( Vdc Vg ) D ( Vdc Vg )... () where V is the average inductor voltage, is the DC-link voltage and is the grid voltage. The average current and the current peak i peak, which are shown in Fig. 4(c) are expressed as, ipeak iavg ( D D )...(3) Vdc Vg ipeak DT...(4) sw where T sw is the switching period. Substituting (4) into (3) and solving the equation for the duty D. The duty D is expressed by iavg D D...(5), DT sw( Vdc Vac) Substituting (5) into () in order to remove the duty D and represent () as a function of only the duty D, then (6) is obtained.

D [~] V V dc (D ) V Nonlinear factor ( - )T sw.5i peak g ( V + dc V g ) ( V dc i V g avg ) D T... (6) Then, the inverter model in DCM is established based on (6). Fig. 5 illustrates the circuit model of the inverter operating in DCM at powering mode which is based on (6). In CCM, the dash line part does not exist, because the average current equals to the half current peak i peak /. On the other words, this makes the ero-current interval D 3 T sw shown in Fig. 3 become ero. However, in DCM, the ero-current interval introduces the nonlinearities into the DCM transfer function. The design of the compensation part for the DCM nonlinearity is explained as in []. The circuit model in Fig. 5 is linearied and discretied at steady state points. Fig. 6 depicts the discretied circuit model at powering mode. Note that _s, _s, and D _s are the DC-link voltage, the grid voltage and the duty at steady state points, whereas, D, and are the small signals of the grid voltage, the duty and the average current, respectively. The erocurrent interval introduces nonlinearities in the grid-voltageto-current transfer function and the duty-to-current transfer function. Fig. 7 (a)-(c) indicates the proposed DCM current controls for the powering mode, for the generation mode and for D 3.5i peak s Do not exist in CCM Fig. 5. Circuit model of inverter operated in DCM at powering mode. In DCM, the current control depends greatly on the current value, i.e. the nonlinearities occurring in the duty-ratio-to-current transfer function and the disturbance-to-current transfer function. ΔD - (i) Nonlinearity in grid-voltage-to-current transfer function _s D _s (_s - _s ) _s + _s Δ - V _s D _s (_s + _s ) (ii) Nonlinearity in duty-to-current transfer function T sw (-) Δ Fig. 6. Discretied circuit model in DCM at powering mode. The original idea of the DCM nonlinearity compensation is to estimate the duty at steady states by the duty at the previous calculation. Consequently, the inductor value is not required in the DCM nonlinearity compensation. V sw Conventional CCM PI Controller * PI - V* + ( - ) ( + ) (ii) Compensation for nonlinearity in duty-to-current transfer function x (i) Compensation for nonlinearity in grid-voltage-to-current transfer function any conditions of the power factor, respectively. As shown in Fig. 7(a), in order to compensate the DCM nonlinearities at the output of the PI controller designed in CCM, the nonlinearity in the duty-to-current transfer function in Fig. 6 is set as, whereas the nonlinearity in the grid-voltage-to-current transfer function is eliminated by feeding forward the grid voltage to the output of the PI controller. In principle, the current control in Fig. 7(b) is the same as that in Fig. 7(a). However, the sign of the absolute value of the grid voltage in Fig. 7(b) is opposite to that in Fig. 7(a), because as shown in Fig. 5(c), (d), the applying order of mode and mode in the powering mode is flipped compared to that in the generation mode. In order to control the DCM current under any conditions of the power factor, the combination of the current control from Fig. 7(a) and (b) is required. By using the information of the output current polarity, the proposed DCM nonlinearity compensation can be employed over entire range of the power factor. Fig. 8 shows the gain of the disturbance response in CCM and DCM under different conditions of the steadystate duty-ratio D _s. In CCM, the minimiation of the inductor value worsens the disturbance response. On the other a b a/b (a) Proposed DCM current control for powering mode Conventional CCM PI Controller * PI - V* - ( + ) a b ( - ) x (i) Compensation for nonlinearity in grid-voltage-to-current transfer function a/b - (ii) Compensation for nonlinearity in duty-to-current transfer function (b) Proposed DCM current control for generation mode Conventional CCM PI Controller * PI V* + sign( *) [ - sign( *)] [ + sign( *)] - x (i) Compensation for nonlinearity in grid-voltage-to-current transfer function a b - (ii) Compensation for nonlinearity in duty-to-current transfer function (c) Proposed DCM current control for any condition of power factor Fig. 7. Proposed DCM current control for any conditions of power factor. By using the information of the output current polarity, the proposed DCM nonlinearity compensation can be employed over entire range of the power factor. a/b D D - D

hand, in DCM when the steady-state duty-ratio D _s becomes smaller, the disturbance response gain in DCM decreases. The reason is that the proposed DCM nonlinearity compensation for the current command response does not compensate for the DCM nonlinearity in the disturbance response. Consequently, the disturbance response depends on the steady-state duty-ratio D _s. Therefore, by utiliing this nonlinearity characteristic in which the disturbance gain decreases greatly with the small steady-state duty-ratio D _s, i.e. the interval near the current ero-crossing point or the light load, the current distortion can be reduced. Disturbance response gain [db] - - -3-4 -5-6 Grid-connected Inductance : 5 mh DC-link Voltage : 38 V Grid Voltage _s : 4 V D _s =.3 D _s =. CCM DCM -7 D _s =.5-8 Disturbance frequency f [H] Fig. 8. Disturbance characteristics in CCM and DCM. The DCM nonlinearity in the disturbance-to-current transfer function makes the DCM current more resistant to the disturbance than the CCM current. Therefore, the interconnected inductor can be further minimied in DCM. Duty ratio.6.5.4.3.. DCM D DCM <D CCM Mode transition point CCM D DCM D CCM D DCM D CCM Inductor current value at Boundary Mode I BCM.5.5.5 Inductor Current [A] Fig. 9. Relationship among CCM duty, DCM duty and current mode. When the circuit operates in DCM, the DCM duty becomes smaller than the CCM duty and vice versa. Using this relationship, the current mode determination is achieved without using the inductor value. C. Current Mode Determination Fig. 9 shows the relationship among the CCM duty, the DCM duty and the current mode. In conventional current mode determination, the average current (the detection value or the command value *) is compared with the current value I BCM at the boundary between CCM and DCM, which is calculated by using the inductor value. Consequently, when the actual inductor value is different from the nominal value, the current mode cannot be accurately determined by the conventional method. On the other hand, the proposed current mode determination focuses on the relationship between the CCM duty and the DCM duty when the current mode alternates. In particular, when the circuit operates in DCM, the DCM duty becomes smaller than the CCM duty and vice versa. Therefore, using this relationship, the proposed current mode determination is achieved without using the inductor value. This makes the MCM controller robust against the change of the inductor value. Fig. indicates the proposed MCM current control and the waveform of the current mode alternation. The CCM duty Duty CCM is calculated without using the inductor value. Similarly, the inductor value is unnecessary in the calculation of the DCM duty Duty DCM, because the inductor value is not used in the DCM nonlinearity compensation. Consequently, the relationship between the CCM duty and the DCM duty which is independent from the inductor value is achieved. Thank to this, the proposed MCM current control can be applied even when the inductors with high tolerance are used. III. ABORATORY SETUP Table I depicts the experimental parameters. The operation frequency of the current controller is synchronied with the sampling frequency of kh despite of the high switching frequency of kh, which enables the use of low speed controllers. Fig. depicts the prototypes of the inverter-side inductors under different conditions of the inductor impedance %Z normalied by the based impedance. Ferrite is chosen * PI V* + sign( *) [ - sign( *)] a b [ + sign( *)] - DCM Duty Generation x a/b - Current Mode Determination Duty DCM NOT Duty - SW SW Current mode alternation.5 CCM Duty Generation.5sign( *) Duty CCM Duty Duty DCM Duty CCM Fig.. Proposed MCM current control for grid-tied inverter operating under any condition of power factor. The proposed MCM current control is independent from the inductor value because the inductor value is not used in both the DCM nonlinearity compensation and the current mode determination.

TABE I SYSTEM PARAMETERS. Circuit Parameter V DC DC link Voltage 38 V Grid Voltage Vrms P n Nominal Power kw Switching Device (SiC MOSFET) SCH8KE Core material and it wire Ferrite N87, /f. f g Grid Frequency 5 H Z b Base Impedance 4 W C b Base Capacitance 79.6 mf C f Filter Capacitor.5 mf f sw Switching Frequency kh Current Controller Parameter f samp Sampling Frequency kh Damping Factor.4 f c Cutoff Frequency kh (%Z =3.%) Vol =cm 3 (.p.u.) w = 35 mm l = 55 mm (%Z =.6%) Vol =5cm 3 (.47p.u.) (%Z =.6%) Vol =5cm 3 (.3p.u.) h = 57 mm w = 9 mm l = 4 mm to be the core material in order to minimie the core loss at the switching frequency of kh, whereas it wire is used in order to minimie the winding loss coming from the proximity effect and the skin effect. By the application of DCM, the normalie impedance of the inductor impedance %Z can be minimied without worsening the disturbance response as shown in Fig. 8. Consequently, by reducing the impedance of the inverter-side inductor %Z from 3.% to.6%, the inductor volume is reduced by 77%. Fig. and Fig. 3 shows the grid voltage, the grid current and the inverter output current of the conventional CCM current control and the proposed MCM current control at rated load of kw and at light load of W, respectively. The IEEE-59-99 standards require the grid current THD below 5% at rated load, which can be accomplished simply with the high impedance of the inverter-side inductor %Z as shown in Fig. (a). However, as is reduced to minimie the interconnected inductor, the disturbance effects in CCM increase with small %Z as shown in Fig. 3. Consequently, the grid current THD increases from.5% to 4.8% when %Z is reduced from 3.% to.6%. This problem can be overcome by increasing the control bandwidth of the current controller, which is difficult to employ with low speed microprocessors. On the other hand, when the inverter is operated in MCM, the disturbance effects naturally reduce at low duties as shown in Fig. 8, i.e. the ero-crossing intervals, h = 43 mm w = 9 mm l = 36 mm Fig.. Prototypes of inverter-side inductors under different conditions of inductor impedance normalied by base impedance. By reducing the impedance of the inverter-side inductor %Z from 3.% to.6%, the inductor volume is reduced by 77%. h = 37 mm Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =.5% Inverter-side-inductor Current ( A/div) (a) Conventional CCM current control with %Z = 3.% at rated load Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =6.8% Inverter-side-inductor Current ( A/div) (b) Conventional CCM current control with %Z =.6% at rated load Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =4.8% Inverter-side-inductor Current ( A/div) (c) Conventional CCM current control with %Z =.6% at rated load Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =.9% DCM CCM DCM Inverter-side-inductor Current ( A/div) (d) Proposed MCM current control with %Z =.6% at rated load Fig.. Grid voltage, grid current and inverter output current of conventional CCM current control and proposed MCM current control at rated load of kw. When the inverter is operated in MCM, the disturbance effects naturally reduce at low duties, i.e. the ero-crossing intervals, due to the nonlinearity in the disturbance response. due to the nonlinearity in the disturbance response. Therefore, the low grid-current THD of.9% is achieved with the proposed MCM current control even when %Z is reduced to.6%. Similarly, the grid current THD at light load of W is also reduced from 7.6% to.5%. Fig. 4 shows the comparison of the grid current THD and the conversion efficiency between the conventional CCM current control and the proposed MCM current control with different of normalied impedances. Even when the normalied impedance of the grid-side inductor %Z is min-

Grid Current Distortion THDig [%] Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =.% Inverter-side-inductor Current ( A/div) (a) Conventional CCM current control with %Z = 3.% at light load Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =.5% Inverter-side-inductor Current ( A/div) (b) Conventional CCM current control with %Z =.6% at light load Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =7.6% Inverter-side-inductor Current ( A/div) (c) Conventional CCM current control with %Z =.6% at light load Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =.5% Inverter-side-inductor Current ( A/div) (d) Proposed MCM current control with %Z =.6% at light load Fig. 3. Grid voltage, grid current and inverter output current of conventional CCM current control and proposed MCM current control at light load of W. imied to.6% of the inverter total impedance, the grid current THD is maintained to be lower than 5% over entire load range by applying the proposed MCM current control. Furthermore, by minimiing %Z to.6%, the efficiency is improved by.5% compared with the normalied impedance of %Z =3.%. Furthermore, in the conventional CCM current control, the lower the grid THD becomes, the higher the conversion loss becomes. On the other words, the trade-off relationship between the grid current THD and the efficiency 4 35 3 5 5 5 7.6.5.5. Current distortion reduced by 8.4% 8.7 7.7 6.8 9.7 4 3.6 3.4.9 Conventional CCM control with 35. %Z =3.% %Z =.6% %Z =.6% Proposed MCM control with %Z =.6% 3..8 occurs in the conventional CCM current control, whereas the proposed MCM control can achieve both the low grid current THD and the high efficiency. Fig. 5 depicts the proposed MCM current control operation at the rated current and under different power factors. The low grid current THD can still be achieved at low power factor with the proposed MCM current control. On the other words, the proposed MCM current control provides the gridtied inverter the capability of fault-ride-through. The effectiveness of the proposed MCM current control is confirmed by these experimental results. IV. CONCUSION When the grid-connected inductor is minimied by reducing the inductor impedance, the disturbance effects increases highly in the CCM operation, which distorts the grid current. On the other hand, in the DCM operation, the non-.6 7.8 4.8.5...3.4.5.6.7.8.9. Output Power P out [p.u.] (a) Grid current THD characteristics Conversion Efficiency h [%] 98 97 96 95 94 93 oss reduced by 36.5% Conventional CCM control with %Z =3.% %Z =.6% %Z =.6% Proposed MCM control with %Z =.6% 9...3.4.5.6.7.8.9.. Output Power P out [p.u.] (b) Conversion efficiency characteristics Fig. 4. Comparison of grid current THD and conversion efficiency between conventional CCM current control and proposed MCM current control with different of normalied impedances. The trade-off relationship between the grid current THD and the efficiency occurs in the conventional CCM current control, whereas the proposed MCM control can achieve both the low grid current THD and the high efficiency.

Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =.8% Inverter-side-inductor Current ( A/div) (a) MCM current control operation at power factor of.95 Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =.8% Inverter-side-inductor Current ( A/div) (b) MCM current control operation at power factor of.9 Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =.6% Inverter-side-inductor Current ( A/div) (c) MCM current control operation at power factor of.85 Grid Voltage (5 V/div) Grid Current i g ( A/div) THD ig =.4% Inverter-side-inductor Current ( A/div) (d) MCM current control operation at power factor of.8 Fig. 5. Proposed MCM current control operation at rated current and under different power factors. The low grid current THD can still be achieved at low power factor with the proposed MCM current control. On the other words, the proposed MCM current control provides the grid-tied inverter the capability of fault-ride-through. linearity occurs in the disturbance response which leads to the natural decrease in the disturbance gain at light load. By utiliing this DCM nonlinearity in the disturbance response, the grid current THD is maintained below 5% over entire load range even with the small normalied impedance of the grid-side inductor of.6%. The main contribution of this paper is that the proposed MCM current control is independent from the inductor value because the inductor value is not used in both the DCM nonlinearity compensation and the current mode determination. REFERENCES [] R. Chattopadhyay, S. Bhattacharya, N. C. Foureaux, I. A. Pires, H. de Paula,. Moraes, P. C. Cortiio, S. M. Silva, B. C. Filho, J. A. de S. Brito, ow-voltage PV Power Integration into Medium Voltage Grid Using High-Voltage SiC Devices, IEEJ J. Ind. Appl., vol. 4, no. 6, pp.767-775, Nov. 5. [] D. Bortis, D. Neumayr, J. W. Kolar, ηρ-pareto Optimiation and Comparative Evaluation of Inverter Concepts considered for the GOOGE ittle Box Challenge, Proceedings of the 7th IEEE Workshop on Control and Modeling for Power Electronics (COMPE 6), Trondheim, Norway, June 7-3, 6. [3] Y. ei et al., "A -kw Single-Phase Seven-evel Flying Capacitor Multilevel Inverter With an Active Energy Buffer," in IEEE Transactions on Power Electronics, vol. 3, no., pp. 857-858, Nov. 7. [4] M. iserre, F. Blaabjerg, and S. Hansen, Design and Control of an C-Filter-Based Three-Phase Active Rectifier, IEEE Trans. Power Electron., vol. 4, no. 5, pp. 8-9, Nov. 5. [5] A. Renik, M. G. Simões, A. Al-Durra, S. M. Muyeen, C Filter Design and Performance Analysis for Grid-Interconnected Systems, IEEE Trans. Ind. Appl., vol. 5, no., pp. 5-3, Apr. 4. [6] J. Imaoka, K. Umetani, S. Kimura, W. Martine, M. Yamamoto, S. Arimura, T. Hirano, Magnetic Analysis, Design, and Experimental Evaluations of Integrated Winding Coupled Inductors in Interleaved Converters, IEEJ J. Ind. Appl., vol. 5, no. 3, pp. 76 88, May 6. [7] K. Senda, H. Toda, M. Kawano, Influence of Interlocking on Core Magnetic Properties, IEEJ J. Ind. Appl., vol. 4, no. 4, pp.496-5, Jul. 5. [8] S. Nagai, Hoai Nam e, T. Nagano, K. Orikawa and J. i. Itoh, "Minimiation of interconnected inductor for single-phase inverter with high-performance disturbance observer," 6 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia), Hefei, 6, pp. 38-35. [9] J. Sun, D. M. Mitchell, M. F. Greuel, Ph. T. Krein, R. M. Bass, Averaged Modeling of PWM Converters Operating in Discontinuous Conduction Mode, IEEE Trans. Power Electron., vol. 6, no. 4, pp. 48-49, Jul.. [] H. N. e, K. Orikawa, J. Itoh, Circuit-Parameter-Independent Nonlinearity Compensation for Boost Converter Operated in Discontinuous Current Mode, IEEE Trans. Ind. Electron., vol. 64, no., pp. 57-66, Feb. 7. [] K. D. Gusseme, D. M. V. de Sype, A. P. V. den Bossche, and J. A. Melkebeek, Digitally Controlled Boost Power-Factor-Correction Converters Operating in Both Continuous and Discontinuous Conduction Mode, IEEE Trans. Power Electron., vol. 5, no., pp. 88-97, Feb. 5. [] Sh. F. im, and A. M. Khambadkone, A Simple Digital DCM Control Scheme for Boost PFC Operating in Both CCM and DCM, IEEE Trans. Power Electron., vol. 47, no. 4, pp. 8-8, Aug.. [3] T. S Hwang, and S. Y. Park, Seamless Boost Converter Control Under the Critical Boundary Condition for a Fuel Cell Power Conditioning System, IEEE Trans. Power Electron., vol. 7, no. 8, pp. 366-366, Aug.. [4] C. W. Clark, F. Musavi, and W. Eberle, Digital DCM Detection and Mixed Conduction Mode Control for Boost PFC Converters, IEEE Trans. Power Electron., vol. 9, no., pp. 347-355, Jan. 4. [5] B. A. Ferrari, N. R. N. Ama, K. C. M. Carvalho, F. O. Martin, and. M. Junior, Robust Control Design for Voltage Tracking oop of Dynamic Voltage Restorers, IEEJ J. Ind. Appl., vol. 4, no. 5, pp. 634-64, Sep. 5.