Power supplies CBC 140-T, CBC 140-1, CBC and CBC 140-5

Similar documents
Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operating Instructions for Phase Demodulator Type _.2

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Electronic Step Controller

MODEL 3810/2 Line Impedance Stabilization Network

Zelio Control Measurement Relays

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

Position Transmitter TGS 40 (RAM)

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC

Operating Instructions. for. Controller SMS 150 / 151

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

02/11/2015

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

US2, US4, US6 Electronic step controllers

ECM3 EARTH CONTINUITY RELAY

E-STOP relays, safety gate monitors

Operating Manual MU2000K

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Advanced Test Equipment Rentals ATEC (2832)

Level Limit Switch nivotester FTL 325 P

CAMTO. Arc detecting relay. system. January Revised August D D1200

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

Operating Instruction

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Lamellar Grinding Machines T-20/T-25 11/2012

EARTH LEAKAGE RELAY RELAY FOR PERMANENT CONTROL OF THE MCCB S TRIPPING CIRCUIT AND ACTUATOR FOR SAFETY CIRCUITS

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

Installation guide 971 SmartRadar LTi

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Datasheet - PROTECT-IE-02

Inductive sensor slot-type SI2-K08-AP7

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

E-STOP relays, safety gate monitors

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

02/11/2015

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Power connections, minimum and maximum wiring capabilities, tightening torque

Operating Instructions

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Series P. Applications

Operating Instructions. for. Controller SMS 160 / 161

TPM + Lenze ECS. Quick Startup Guide D Revision: 02

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Inverter MICROMASTER 410

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

02/11/2015

SERIES KC RELAY NONLATCH 3PDT, 25 AMP

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP

Industrial Automation HIMatrix System. Manual H 7032

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

Multiple Program Process Temperature Controller. Installation Guide Maxitrol Company, All Rights Reserved

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display.

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

PRetrans Table of contents

SOLID STATE RELAY RATINGS

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

MDW-45 Converter RS RS-422/485

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing)

1-7. Product information Temperature Monitoring. Type: TMS U. Thermal control module:

Signal converter for electromagnetic flowmeters

Installation, Operation and Maintenance Instructions

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

User's Guide for type ACS55 AC Drives from 0.18 to 2.2 kw

Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available.

TC1028 series. Thyristor units. Control of single-phase resistive or inductive loads. User manual (300A to 500A rated units)

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

BEA s digital inductive single loop solution

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

Operating instructions Fail-safe delay timer AZS About this document. Content

Manual. Frequency Inverter. Series KFU 2- / 4- 0,55 to 3,0 kw 230 V KFU 2-0,55 to 132 kw 400 V KFU 4- KN E

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

MW3105 DIGITAL CLAMP MULTIMETER

ESwitch. User Guide. Power Contactor

BC145 SIGNAL ISOLATOR BOARD

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

This Chapter contains:

Warning DECLARATION OF CONFORMITY. For your protection, please read the following:

Remote Switching Unit nivotester FTL 320

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

The EVI 30/8 coils can be equipped with the suitable plunger guide tube (see S8 - S9 Catalogue).

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

CONTROL UNITS. VEHICLE EXHAUST GASES Pure advantages VEHICLE EXHAUST GASES

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

Type CP-S, CP-C & CP-A Switch mode

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Transcription:

SM326gb - rev 12/06 S E R V I C E Power supplies CBC 140-T, CBC 140-1, CBC 140-2 and M A N U A L WARNER ELECTRIC EUROPE Rue Champfleur, B.P. 20095, F- 49182 St Barthélemy d Anjou Cedex Tél. +33 (0)2 41 21 24 24, Fax + 33 (0)2 41 21 24 00 www.warnerelectric-eu.com

We, WARNER ELECTRIC EUROPE, 7, rue Champfleur, B.P. 20095, F-49182 St Barthélemy d Anjou Cedex state under our sole responsibility, that products in the family: CBC 140-T, CBC 140-1, CBC 140-2, are solely intended to be incorporated in an installation or to be assembled with other equipment with a view to constituting a machine to which directive 98/37/EC as amended applies. The products specified above comply with the requirements of Low Voltage directive 73/23/EC as amended through full conformity with the following standards: EN 61010-1, 6.5.1/6.7/6.2/6.8.4 and VDE 0160,5.7/5.5.1/7.6.1/7.6.2 If installed and wired as instructed (Chap 3), these products comply with standards EN50081-1 and EN50082-1 relative to CEM directive 89/336/EEC as amended. Drawn up in St Barthélemy d Anjou, July 2002 Eric Prat, General Managing Director CONTENTS 1 Description 2 2 Characteristics 2-3 3 Dimensions and connections 3-5 1 Description These Warner Electric series CBC 140-T, CBC 140-1, CBC 140-2 and supply units are designed to control Warner Electric Direct Current, electromagnetic brakes and clutches CBC 140-T : Supply unit transformer CBC 140-1 : Supply unit with single wave rectificatio for low current. CBC 140-2 : Supply unit with dual wave rectification for low current. : Supply for high current with single or dual wave rectification, with possibility of overexcitation/ holding voltage Max. Input voltage : 230VAC Presentation in box The built-in protection limits the reverse voltage from induction and protects the control switches. The power supplies are fitted with a built-in fuse to protect from short circuits, located beneath the part of the box carrying the identification label (see Chap. 3.) 2 Characteristics 2-1 Convertor CBC 140-T Reference: B 905-9999 Input voltage: 230/40 Output voltage: 27.5 VAC / 3 Power: 150 VA Current: 6 A 2-2 Power suplies See tables 1 and 2 Name CBC 140-1 CBC 140-2 Reference ACG830A1P1 ACG830A1P2 Frequency (Hz) 50/60 50/60 Input voltage (VAC) 230/400 27 115 230 Output voltage (VDC) 103,5/180 24 103,5 207 Max. current (A) 1 2 2 2 Table 1 WARNER ELECTRIC EUROPE - Rue Champfleur, B.P. 20095, F - 49182 St Barthélemy d Anjou Cedex SM326gb - rev 12/06 2/5

Symbol designating an action that might damage the brake Symbol designating an action that might be dangerous to human safety Symbol designating an electrical action that might be dangerous to human safety Name Reference 7 67 000416 Frequency (Hz) 50 / 60 Input voltage (VAC) Terminal 1 and 2 U 230 115 30 State of contact Terminals 3 et 4 Closed Open Closed Open Closed Open Closed Open Ouput voltage VDC Terminals 7 et 8 U x 0,9 U x 0,45 207 103,5 103,5 51,7 24 12 Max. current (A) - - 2 4 4 4 4,5 4,5 Max. power (W) - - 414 414 414 207 108 54 Admissible max. power (W) during overexcitation 2s max - - 828 828 414 414 108 108 Table 2 3 Dimensions and connections WARNING The current present in these supply units can cause serious injury (or even death). Ensure when installing them or any other electrical equipment that the supply is switched off. 112 Only switch on again when fully installed and properly wired in accordance with local regulations and all installation, including cleaning, is fully completed. 126 All works on the electrical connections have to be made with power off. 40 3-1 The units should be fitted in a closed metal cabinet. 3-2 Power link between control and clutch / brake by screened cable. 3-3 Setting connection, inputs and outputs by screened cables 105 CBC 140 - T 116 3-4 Screens are connected to earth at both ends of the cable. 3-5 Control cables and power 3 27,5 VAC WARNER ELECTRIC EUROPE - Rue Champfleur, B.P. 20095, F - 49182 St Barthélemy d Anjou Cedex SM326gb - rev 12/06 3/5

CBC 140-1 46 CBC 140-2 40 ø 4,5 18 CBC 140-1 CBC 140-2 1 2 3 4 5 6 3 28 AC + - DC : contactor (3 A / 400 V), not supplied Mounting on a DIN rail (EN50-022) Fuse 6,3 A 1 OR 2 waves POWER SUPPLY 1 OR 2 WAVES POWER SUPPLY OUTPUT VDC : : 207V/2A - 103.5-103.5 V/4A - V/4A 24V/4.5A - 24V/4.5A 7 / 8 SWITCH ON/OFF 5 / 6 Choice 11 or or 2 waves 2 waves 3 / 4 1 / 2 2 waves ON 2 waves Input U x 0.9 Max 230 VV U 1 wave OFF 1 wave U x 0.45 1 2 3 4 5 6 7-8+ 90 DIN RAIL EN50022 71 58 Connection examples, apparatus supply, 24 VDC with a convertor CBC 140-T 40 : contactor (9 A / 400 V), not supplied CBC 140 - T 27,5 VAC 3 Shunt 24 VDC WARNER ELECTRIC EUROPE - Rue Champfleur, B.P. 20095, F - 49182 St Barthélemy d Anjou Cedex SM326gb - rev 12/06 4/5

Apparatus supply, 103,5 VDC, from : contactor (9 A / 400 V), not supplied 103,5 VDC Apparatus supply 103,5 VDC, with overexcitation 207 VDC then holding voltage 103,5 VDC, from Temporised relay (0,5 to 2 s, 9 A /400 V) not supplied : contactor ( 9 A / 400 V), not supplied 207 / 103,5 VDC Apparatus supply 48 VDC, with overexcitation 103,5 VDC then holding voltage 48 VDC, from 115 VAC Temporised relay (0,5 to 2 s, 9 A /400 V) not supplied : contactor ( 9 A / 400 V), not supplied 115 VAC 103,5 / 48 VDC Subject to alteration without prior notice WARNER ELECTRIC EUROPE - Rue Champfleur, B.P. 20095, F - 49182 St Barthélemy d Anjou Cedex SM326gb - rev 12/06 5/5