RMD5000 Rackmount Kit Instructions

Similar documents
RM4000 Tektronix 4000 Series Rackmount Kit

RM4000 DPO4000 Series Rackmount Kit

RMD2000 DPO2000 and MSO2000 Series Rackmount Kit Instructions

RMD3000 DPO3000 Series Rackmount Kit

RM5 Rackmount Kit Instructions

TLA72X, TLA7XM, & TLA7016 Benchtop Mainframe Rackmount Installation

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Powerware Series. Eaton Rail Kit 9- and 12-Slot Cabinets Installation Guide

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit

S6 User s Manual USER S MANUAL ver. 1.0

PULL-THRU USER S MANUAL

LAN Locker Adjustable Shelves

COPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX Standard Release A March 2008

INSTALLATION INSTRUCTIONS

Media Storage Systems Fixed Media Cabinets

WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. WARNING. Ranger XP Door Kit

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

RBP-1215B-RX DODGE RAM QUAD CAB RX3

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

INSTALLATION MANUAL. All Recessed Wall-Mount Modules Front-Loading, Rear-Loading, Parcel-Only, Collection Box, Trash/Recycling Bin

TorqueMaster Replacement Spring

4Post and 2Post Sliding Rails for Lenovo/IBM M5

INSTALLATION INSTRUCTIONS

Be sure any accessory used will fit with the soft upper doors before installing. Not all accessories will be compatible.

F l a t S c r e e n A R M S I n s t a l l a t i o n

INSTALLATION INSTRUCTIONS

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

INSTALLATION INSTRUCTIONS

Introduction. Rocky Mountain Westy Swing Away Carrier Kit Installation Instructions

FreshSesh, PowderHound & Big PowderHound

Please read BOTH these Installation Instructions and the General Instructions before attempting to install or operate this equipment.

Slide Rail Kit DVA-ASRK-28A DVA-ASRK-36A. Installation Manual

Paramount Enclosure. Installation Guide

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

CREW REAR DOOR KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

REC Series Rack Installation Guide

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

BOX-117 E-Z-Go RXV Utility Box Mounting Kit Installation Instructions


Side Mount INSTRUCTION BOOKLET #C122 BED STYLE: PARK CITY

3 BAY AV CREDENZA WITH SINGLE DISPLAY MOUNT


INSTRUCTIONS INSTRUCCIONES CONSIGNES

Installation Instructions - Model V4JSD 1

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

Riverside. Oakmont Queen Storage Bed Assembly Instructions

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE PREMIUM FRONT BUMPER. AEV30103AE Last Updated: 09/08/14 US PATENTS: D683281, D CHINESE PATENT: ZL

w w w. h d o n l i n e s h o p. d e VRSCF RIGID SADDLEBAGS GENERAL PREPARATION -J04704 REV Kit Number Models Tools and Supplies Required

INSTALLATION INSTRUCTIONS

Planar FWMG-MXL INSTALLATION INSTRUCTIONS

4Post and 2Post Rails for Dell PowerEdge R810

Repair Instructions. Replacing a La Z Time Mechanism Side Subassembly. Remove the Back(s): Remove the Mechanism Assembly: CAUTION.


6 BAY AV CREDENZA WITH DUAL DISPLAY MOUNT

INSTALLATION INSTRUCTIONS 3 BULL BAR 99-04, 04 "HERITAGE" F-150/250LD 2WD, 97-04, 04 "HERITAGE" 4WD WD EXPEDITION/ WD EXPEDITION PART

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

PROFILE Flat Panel Console System Installation Manual

VACUSEAL MODEL 200. HOT TUB PRODUCTS 233 Carrington Road Bethany CT

INSTALLATION INSTRUCTIONS

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

WARNING Honda Civic (Incl. EX, LX, DX) Installation Instructions BX2243. Serial Number

Installing flat panels on the MPL15 wall mount

INSTALLATION INSTRUCTIONS ATV WINCH MULTI-MOUNT Multi-Mount Mounting-Kit: PN Application: YAMAHA BIGBEAR 00+

Installing the Profile Privacy Panel. Assemble top mounting bracket. Prerequisites. Tools

WARNING. BX Ford Explorer With Adaptive Cruise Control & Eco Boost Installation Instructions

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

(2) Plastic Plugs (2) Frame Bracket. Spacers. License Plate Bracket. (2) 12mm Single Bolt Plates. (2) 12mm Double Bolt Plates

INSTALLATION INSTRUCTIONS

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

4Post Server Rack-111 Assembly For Floor Anchored Models

Bluetooth DRO Installation for Bench Mills

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

WILDING WALLBEDS INSTALLATION INSTRUCTION Side Mount

Installation Instructions

INSTALLATION INSTRUCTIONS


Custom Wood Frame Overlay for Glass Doors Installation Instructions

MANUAL e130. Wallstation

Arc Trainer Main Frame Assembly

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

Hiniker Company th St. P.O. Box 3407 Mankato, MN VEHICLE INSTALLATION INSTRUCTIONS FOR: CHEV/GMC 4x4: K1500 SILVERADO/SIERRA

Preference Collection and Treatment Console INSTALLATION GUIDE

Please read BOTH these Installation Instructions and the General Instructions before attempting to install or operate this equipment.

INSTALLATION INSTRUCTIONS Horizontal And Vertical Table Stands and Accessories Model: KTP-Series

Riverside. Windhaven Queen Storage Bed Assembly Instructions

INSTALLATION INSTRUCTIONS

Please read BOTH these Installation Instructions and the General Instructions prior to installing or operating this equipment.

FORD MOUNT INSTALLATION INSTRUCTIONS

Eaton Data Center Racks

Mighty Mo GX Series Cabinet Installation Guide. OR Rev /11

Riverside. Harbor Hill Queen Storage Bed Assembly Instructions

Customer Notice: Congratulations again on your SawStop purchase, and thank you! -SawStop Tualatin, OR

Transcription:

xx ZZZ RMD5000 Rackmount Kit Instructions www.tektronix.com *P075102000* 075-1020-00

Copyright Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specifications and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. Contacting Tektronix Tektronix, Inc. 14150 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA For product information, sales, service, and technical support: In North America, call 1-800-833-9200. Worldwide, visit www.tektronix.com to find contacts in your area.

Service Safety Summary Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary in the product service manual or the instruction manual. Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present. To prevent the instrument and rack from falling onto the operator, two or more installers should install the instrument into the rack cabinet. After completing the installation procedure, the installers should verify that the instrument and rack cabinet will not tip forward while the instrument is in the extended position. Disconnect Power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power. UseCareWhenServicingWithPowerOn. Dangerousvoltagesorcurrentsmay exist in this product. Disconnect power and disconnect test leads before removing protective panels, soldering, or replacing components. To avoid electric shock, do not touch exposed connections. RMD5000 Rackmount Kit Instructions 1

Kit Description Kit Description These instructions describe the installation of the rackmount kit to your standard bench-top instrument. The rackmount kit is a collection of parts that, once installed, configure the instrument for mounting in a fixed position into a standard 19-inch equipment rack. (See Table 1.) If you require the instrument to slide in and out of the rack, order the optional slide kit. (See Table 2.) Products DPO4000B Series All Serial Numbers MSO4000B Series AllSerialNumbers DPO5000 Series AllSerialNumbers MSO5000 Series AllSerialNumbers Kit Parts List The parts included in this rackmount kit are listed below. (See Table 1.) (See Figure 1 on page 3.) Table 1: RMD5000 Rackmount kit Item Quantity Part number Description 1 1 each 407-5531-XX PLATE, MOUNTING; RACKMOUNT LEFT 2 1 each 407-5532-XX PLATE, MOUNTING; RACKMOUNT RIGHT 3 1 each 407-5534-XX PLATE, SUPPORT; RACKMOUNT TOP 4 1 each 407-5533-XX PLATE, SUPPORT; RACKMOUNT BOTTOM 5 1 each 426-2636-XX PLATE, SUPPORT; RACKMOUNT FRONT 6 1 each 016-2037-XX HARDWARE KIT 7 1 each 016-2038-XX COMMON HARDWARE KIT 1 each 075-1020-XX TECH MANUAL: INSTRUCTIONS, RACKMOUNT KIT Optional Accessories Table 2: Optional Accessories Part number 351-1095-XX Description SLIDE ASSY; PAIR, W/STD HARDWARE KIT AND REAR BRACKET 2 RMD5000 Rackmount Kit Instructions

Kit Description Figure 1: Rackmount kit parts (part appearance may vary) Figure 2: Optional slide assembly kit RMD5000 Rackmount Kit Instructions 3

Kit Description Warranted Characteristics When the instrument is installed according to the instructions in this document, the rack-mounted instrument meets all warranted characteristics listed in the instrument specification except for those listed. (See page 5, Environmental Requirements.) Instruments mounted using methods other than those described in these instructions may not meet their warranted characteristics. See the specifications for your instrument model for tables of the warranted characteristics. Cooling air enters on the bottom and right sides as shown. (See Figure 3.) You must provide adequate cool air to meet the ambient temperature requirements listed. (See Table 3 on page 5.) Figure 3: Instrument cooling 4 RMD5000 Rackmount Kit Instructions

Kit Description Environmental Requirements The following environmental characteristics supersede those listed in the specifications and performance verification sections of the manual for your instrument. Table 3: Warranted characteristics Characteristic Temperature inside rack cabinet Operating Nonoperating Shock Operating and nonoperating Description +10 Cto+45 C(+50 Fto+113 F) 22 C to +60 C ( 7.6 F to +140 F) 20 g, 11 ms, half sine, each axis, 3 drops each Clearance Requirements The rack in which the rack adapted instrument is mounted must provide the following clearance requirements: A minimum of 8.75 in (222.25 mm) of vertical space A minimum width of 17.72 in (450.09 mm) between the left- and right-front rails in the rack A minimum depth of 12.75 in (323.85 mm) CAUTION. Adhering to these clearance requirements provides the rack-mounted instrument with sufficient clearance for air circulation and accommodation of the power cord and mounting hardware. Failure to provide these clearances can result in overheating and can cause instrument faults or failure. RMD5000 Rackmount Kit Instructions 5

Kit Description Figure 4: Instrument with rack adapter installed 6 RMD5000 Rackmount Kit Instructions

Installation Instructions This section contains the procedures needed to rackmount a DPO4000B, MSO4000B, DPO5000, or MSO5000 series instrument. Minimum Tool and Equipment List The following tools are required to attach the rack-adapter kit hardware, install cabling hardware, and mount the rack-adapted instrument into a standard equipment cabinet. All tools are standard tools that are readily available. Table 4: Tools required for rackmount installation Name Description Screwdriver handle Accepts 1/4-inch hexagonal head driver tips (magnetic) No. 2 Phillips or Phillips or PoziDriv-driver tip for number 2 size screw heads PoziDriv tip T-10 TORX tip TORX-drive tip for T-10 size screw heads (flat-head) T-15 TORX tip TORX-drive tip for T-15 size screw heads T-20 TORX tip TORX-drive tip for T-20 size screw heads 1/4-inch wrench Torque driver Wrench or nut driver can be used to install slides 6.5 in long shaft; accepts 1/4-inch hexagonal head driver tips These instructions are for qualified service personnel who are familiar with servicing the product. If you need further details for disassembling or reassembling the product, refer to the appropriate product manual. Contact your nearest Tektronix Service Center or Tektronix Factory Service for installation assistance. WARNING. To prevent the rackmounted instrument from tipping forward onto the operator, install the instrument so that the operator will be able to access all of its rear-panel connectors without pushing down on the instrument. Verify that the rack does not become unstable with the instrument fully extended. Do not leave the instrument extended when finished accessing the rear panel. WARNING. To avoid electric shock, disconnect the power cord from the mains power before removing the cover. Failure to do so could result in personal injury or death. RMD5000 Rackmount Kit Instructions 7

Remove Equipment Required: Screwdriver handle with T-15 tip. This procedure prepares the instrument for installation of the rackmount parts. NOTE. Retain all parts removed from the instrument for later use. Some of those parts will be reinstalled as you perform this rack conversion; store the remainder in case reconversion to a standard instrument configuration is desired at a later time. 1. Disconnect the power cord from the rear of the instrument. 2. Remove the four T-15 TORX screws that secure the rear cover to the front case assembly. (See Figure 5.) 3. Remove the rear cover. Figure 5: Removing the rear case cover 8 RMD5000 Rackmount Kit Instructions

Install This section describes mounting the rackmount parts to the instrument. Equipment Required: Torque driver with T-15 and T-20 tips. 1. Assemble the left and right mounting plates to the bottom support plate usingsix6-32x0.250inchpanheadt-15 TORX-drive screws tightened to 8 in-lb. (See Figure 6.) NOTE. The bottom support plate has holes to facilitate mounting optional accessories. You can use screws or nylon straps to mount accessories. Figure 6: Assembling the left and right mounting plates RMD5000 Rackmount Kit Instructions 9

2. Fasten the front support plate to the left and right mounting plates with six 6-32x0.250inchpanheadT-15TORX-drivescrews,liningupthedimplesin the back support plate with the slots in the mounting plates. (See Figure 7.) Tighten screws to 8 in-lb. Figure 7: Assembling the rackmount front support plate 3. Install the two handles using four 10-32 x 0.25 inch pan head T-20 TORX-drive screws tightened to 16 in-lb. Handles should curve towards the sides of the instrument. 10 RMD5000 Rackmount Kit Instructions

4. Install the top support plate; note the orientation for the different instruments: (See Figure 8.) For DPO4000B instruments, install the top support plate with the flange toward the front of the enclosure so that the DPO4000B stamping on the plate is visible. For DPO5000 instruments, install the top support plate with the flange toward the back of the enclosure. Figure 8: Installing the top support plate RMD5000 Rackmount Kit Instructions 11

5. Install the instrument into the rackmount enclosure using six 6-32 x 0.250 inch flat-head T-15 TORX-drive screws tightened to 8 in-lb. (See Figure 9.) Figure 9: Installing the instrument in the enclosure 12 RMD5000 Rackmount Kit Instructions

This completes the installation of the standard rack-adapter hardware included in this kit. The instrument is now ready to mount in a fixed location, to the front rails of a standard instrument rack. To mount the instrument in a fixed location, proceed to Finishing the Installation. (See page 21, Finishing the Installation.) If you require the instrument to slide in and out of the instrument rack, order the optional slide assembly kit and use the instructions that follow. (See page 14, Mount the Track Hardware (Optional).) RMD5000 Rackmount Kit Instructions 13

Mount the Track Hardware (Optional) Install the optional slide assembly kit as follows: 1. Remove the front section of each of the two tracks. (See Figure 10.) Figure 10: Preparing the tracks for mounting 2. Install the front left- and right-side track sections on the instrument using four 6-32 x 0.250 inch pan head T-15 TORX-drive screws tightened to 8 in-lb. (See Figure 11.) Figure 11: Installing the left- and right-side track sections 14 RMD5000 Rackmount Kit Instructions

WARNING. To ensure that the rackmount track locks, make sure the track button latches are oriented correctly: the right-side latch is located toward the bottom of the rackmount panel and the left-side latch is located toward the top of the rackmount panel. (See Figure 12.) If the button latches are not oriented correctly the instrument could slide from the rack, which could cause personal injury or damage to the instrument. Figure 12: Track orientation This completes the installation of the slide hardware to the instrument. To complete the installation, proceed to: Rackmount the Rack- Adapted Instrument. (See page 16.) RMD5000 Rackmount Kit Instructions 15

Rackmount the Rack-Adapted Instrument This procedure assembles and installs the slide-out tracks in the equipment rack, and then installs the rack-adapted instrument in the rack. The slide-out tracks permit the rack-adapted instrument to be extended out of the rack for rear-panel and connector maintenance without removing the instrument from the rack. WARNING. To prevent the rackmounted instrument from tipping forward onto the operator, install the instrument so that the operator will be able to access all of its rear devices without pushing down on the instrument. Verify that the rack does not become unstable with the instrument fully extended. Do not leave the instrument extended when finished accessing the rear panel. Install Track Assembly and Instrument into the Rack Equipment Required: One screwdriver handle, one number two PoziDriv tip, and one torque driver. NOTE. The rack hardware kit contains hardware for mounting the instrument in several configurations. Not all of the hardware in the kit will be needed. A standard equipment rack has rails with universal hole spacing. If you use a rack with other than universal hole spacing, you may have to drill additional mounting holes in the rack. 1. Assemble the slide-out track: a. Measure the distance between the front and rear rail of the equipment rack. 16 RMD5000 Rackmount Kit Instructions

Figure 13: Slide-out track assemblies b. Align the rear bracket to the right slide-out track as shown. (See Figure 13.) Note that the rear bracket has multiple pairs of mount-through holes. When aligning the bracket and track, be sure to select a pair of holes that mount the rear bracket so that the flange-to-flange distance matches the distance between the front rail and rear rail measured in step a. c. Using a screwdriver with a number two PoziDriv tip, secure the rear bracket to the right slide-out track using two screws (10-32) and a bar nut as illustrated. Leave the screws loose so that the overall length of the slide-out track assembly can be adjusted when installing it in the rack. d. Repeat steps b and c to assemble the left slide-out track assembly. RMD5000 Rackmount Kit Instructions 17

2. Mount the slide-out track assemblies, using the slide drawer hardware listed in the kit parts list: a. Select the mounting position in rack: Select two 0.5 inch-spaced holes in the front rail. Verify that the 4.36 inch and 10.500 inch clearances exist relative to those mounting holes. (See Figure 14.) Figure 14: Vertical clearances for rack installation (left-front rail shown) 18 RMD5000 Rackmount Kit Instructions

b. Select the mounting method according to rack type: To mount the slide-out tracks with their front and rear flanges outside of the front and rear rails, use the mounting method A shown when doing substep c. (See Figure 15.) Add a bar nut to the installation only if the rails have untapped holes. To mount with front and rear flanges inside of rails, use the mounting method B. This mounting method assumes untapped holes. Figure 15: Installing slide-out track assemblies in rack (top view) c. Install in rack: Using the method and hardware determined from substep b, secure the right slide-out track assembly to its front and rear rails. The screws should be lightly seated so mounting can be adjusted later. RMD5000 Rackmount Kit Instructions 19

d. Fixthelengthof the slide-out track assembly: Tighten the screws left loose in step 1, substep c, applying 28 inch-lb of torque, to fix the front to rear flange spacing of the slide-out track assembly. e. Mount the left slide-out track assembly: Repeat substeps c through d to mount the left slide-out track assembly. 3. Mount the instrument in the rack: WARNING. To prevent the instrument from tipping or dropping onto the installers, two or more people should install this instrument into the rack cabinet. After completing the installation procedure, the installers should verify that the instrument and rack cabinet will not tip forward while the instrument is in the extended position. a. Install the instrument: Working from the front of the rack, slide the inner track of each slide-out track assembly until it extends out the front of the rack. Continue to slide them out until they lock. Insert the left and right tracks that extend from the rear of the instrument into the ends of the tracks just extended. Make sure the tracks mounted on the instrument slip inside the inner tracks extended earlier. Slide the instrument backward until it stops. Push to release the button latches, located on the outside of each track, and continue to slide the instrument all the way into the cabinet. b. Level the rackmounted instrument: Tighten the four screws that were left loose at the rear of the rack when you did step 2, substep c, and then pull the instrument partially out of the rack. Be sure that the four screws that were left loose at the front of the rack are loose enough to allow the slide-out track assemblies to seek their normal positions. Retighten the four screws and push the instrument all the way into the rack. If the tracks do not slide smoothly, readjust the level using the method just detailed. When leveling is completed, tighten the 10-32 screws using 28 inch-lb of torque. 20 RMD5000 Rackmount Kit Instructions

Finishing the Installation If you intend to mount the instrument to the rack without slides, use this procedure to complete your installation. If you mounted the slide track kit to the instrument, you should also perform this step to secure the instrument to the rack. WARNING. To prevent the rack-mounted instrument from sliding forward and causing personal injury or instrument damage, always secure the instrument to the rack if the rack is moved (for example, if the rack is repositioned or relocated to another room). Secure the instrument to the rack using four 10-32 x 0.625 in screws and rectangular washer spacers as shown. (See Figure 16.) Figure 16: Securing the instrument to the rack *Endofdocument* RMD5000 Rackmount Kit Instructions 21