AMPLIFIER RESEARCH... APPLICATION NOTE: 23

Similar documents
AMPLIFIER RESEARCH... APPLICATION NOTE: 20

AMPLIFIER RESEARCH... APPLICATION NOTE: 19

Model AS08010, M1 AR System 10kHz 8GHz

Specification for Radiated susceptibility Test

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

CONDUCTED RF EQUIPMENT POWER AMPLIFIERS. Practical RF Immunity System Design Considerations

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

Advanced Test Equipment Rentals ATEC (2832)

RF Test Accessories. Antenna Coupler. TC-93010C fitted with F930102A TC-93013A. Frequency Range : 820 ~ 960 MHz. Frequency Range : 0.

pel.com Microwave & RF, March 23 rd, 2016.

EMC Test Facility Sale

We re In The Business Of Making Your Life Easier

Application Note #38B Automotive 600V/m Radar Pulse Test Solution

Modulated Wideband Power Amplifier

Model AS18071, M1, M2 AR System 10kHz 18GHz

LOG PERIODIC ANTENNA MODEL LPA MHz - 1 GHz

Product Description. Theory of operation

EMC ANECHOIC CHAMBERS 5-METER CHAMBERS

PARALLEL ELEMENT ANTENNA MODEL PEA-30

Failing EMC testing? > 50% of products fail EMC testing first time around

Future In Radiated Immunity Testing

LS200 TEST DATA IEC61000 SERIES

Quiet Amps DC to 45 GHz For NMR/MRI Testing.

INSTRUCTION MANUAL TRI-PLATE LINE MODEL EM-7310

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

Advanced Test Equipment Rentals ATEC (2832)

FISCHER CUSTOM COMMUNICATIONS, INC.

How will the third edition of IEC affect your test facility?

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

Application Note #60 Harmonic Measurement for IEC And other Radiated Immunity Standards

Semi Anechoic Chamber (SAC)

RIGOL Presents: New Solutions for Affordable Pre- Compliance Testing

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

RF Conducted Immunity and Automotive Transient Generator Test Systems

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Double-Ridged Waveguide Horn Antennas

Large E Field Generators in Semi-anechoic Chambers for Full Vehicle Immunity Testing

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

No. 1. BROADBAND RF-POWER-AMPLIFIERS 10 khz - 6 GHz. For immunity tests according to IEC, EN, ISO, SAE, MIL

Test and Measurement for EMC

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

DARE!! Instruments Application Note GHz Radiated RF Immunity Testing

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

EMC Near-field Probes + Wideband Amplifier

Trees, vegetation, buildings etc.

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

Application Note #41A Update on the latest release of IEC , Edition 3

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

Model 3180B Mini-Bicon Antenna User Manual

EMI Pre-Compliance Testing Solution

EMC Evaluation at Green Bank: Emissions and Shield Effectiveness

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

RADIATED IMMUNITY TEST SYSTEM 6 GHz

88950-A Series A Series INSTRUCTION MANUAL

RADIATED EMISSIONS MEASUREMENTS IN AN OPEN AREA TEST SITE

FFT 3010 EMI TEST RECEIVER

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software

Model 3140B BiConiLog Antenna User Manual

GTEM cells. Emissions and immunity testing in a single, shielded environment

Radiated Immunity Test System 6 GHz

Demo / Application Guide for DSA815(-TG) / DSA1000 Series

GTEM For emission and immunity testing according to IEC/EN Introduction

2620 Modular Measurement and Control System

Essential Capabilities of EMI Receivers. Application Note

SEMASPEC Provisional Test Method for Evaluating the Electromagnetic Susceptibility of Thermal Mass Flow Controllers

The Reverse Polarity TNC(m) RF connector can be easily secured or removed from equipment in the field by a single gloved hand, no tools required.

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Bulk Current Injection Probe Test Procedure

Test specification: Section (e)(1), Radiated emissions below 40 GHz Test procedure: ANSI C63.4, Sections 8.3.2, 13.2, 13.4 Test mode: Compliance

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

EMC LAB EQUIPMENT CALIBRATION SCHEDULER

1.0 General Description

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11

TEST REPORT: ELECTROMAGNETIC COMPATIBILITY - ESA Regulation Consolidated to Supplement 2 (Revision 4 Amendment 2)

We ve Bent The Rules. AR s Bent-Element Approach Provides A Size Reduction Of Up To 75%, Along With Great Performance.

Test Laboratory No Accredited by CAI for Electromagnetic Compatibility, Electrical Safety and Electrical Cable Tests

EMI Test Lab LLC Electro Magnetic Interference Testing EmiTestLab.com

RESISTIVE POWER SPLITTERS AND DIVIDERS

Log Periodic Dipole Array Antenna

ETS Lindgren Anechoic Chamber

LANGER EMV-TECHNIK. Operating Instructions. A 100 / A 200 / A 300 Optical Fibre Probe

Model 3116 Double-Ridged Waveguide Horn

Digital Step Attenuator

Mhow (MP) PIN c/o 56 APO RFI : PROCUREMENT OF FAST TRANSIENT RESPONSE ELECTROMAGNETIC PULSE (EMP) SIMULATOR

Model BiConiLog Antenna. User Manual

SynthNV - Signal Generator / Power Detector Combo

Measurement Notes. Note 63. March Automated and Adaptive RF Effects Testing

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

ENGINEERING TEST REPORT #: A LSR JOB #: C-2411

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

EMC & Electrical Test Laboratory EMC LAB EQUIPMENT RESOURCES PER OEM TEST METHOD EQUIPMENT DCX FORD GM

Transcription:

AMPLIFIER RESEARCH... APPLICATION NOTE: 23 PRODUCTS THAT PROVIDE 200 V/m CW OR PM AT A DISTANCE OF 1 METER 1 The Amplifier / Antenna / Cell combinations shown in Table 1 provide various means of generating 200 V/m, CW or Pulse Modulated, inside a TEM Cell, between the elements of an E-field generator, or at a distance of one meter from a radiating antenna, from 10kHz to 18GHz. This table is used in conjunction with the enclosed product selection flow chart and system diagrams. The appropriate combination of products is determined by first noting the physical size of the Device Under Test (DUT). The size of the test object determines the appropriate path taken on the flow chart. Follow the path that accommodates the maximum expected DUT size. As an example, to test a device 14 inches or less on a side across the entire frequency band from 10kHz to 18GHz, select items 7, 8, 9, 10, and 11. If the test object were greater than 14 inches, items 1, 2, 3, 4, 5, and 6 would be appropriate. When testing small objects, a TEM cell offers an economical solution in that it is used in lieu of both a radiating antenna and a shielded enclosure. For a test object 4 inches or less in height, select items 12 and 13. If the DUT is 2 inches or less in height, then items 14 and 15 can be used. To accurately determine field strength in the area of the DUT, a field monitor such as the Amplifier Research FM5004 and an appropriate field probe are required. Contact the factory for specific recommendations. Rev090401

200 V/m CW OR PM AT A DISTANCE OF 1 METER 1 ITEM 2 FREQUENCY AMPLIFIER ANTENNA or CELL DUT PLACEMENT 1 10kHz-25MHz 2500L AT3001 Between Elements 2 25MHz-220MHz 2500L AT2000 1 meter 3 220MHz-1GHz 500W1000A AT4000 1 meter 4 1GHz-4GHz 100S1G4 3 AT4510 1 meter 5 4GHz-8GHz 200T4G8 3 AT4003 1 meter 6 8GHz-18GHz 200T8G18A AT4530 1 meter 7 10kHz-100MHz 250A250A AT3100 Between Elements 8 100MHz-1GHz 1000W1000A AT1080 1 meter 9 1GHz-4GHz 100S1G4 3 AT4510 1 meter 10 4GHz-8GHz 200T4G8 3 AT003 1 meter 11 8GHz-18GHz 200T8G18A AT4530 1 meter 12 10kHz-250MHz 75A250A TC3020A Center of Cell 13 250MHz-375MHz 150W1000 TC3020A Center of Cell 14 10kHz-250MHz 25A250A TC1510A Center of Cell 15 250MHz-750MHz 30W1000B TC1510A Center of Cell Table 1 Caution: There are a number of factors that impact the ultimate selection of a power amplifier for immunity testing. Depending upon the actual test configuration, one must plan on cable and connector losses, insertion loss through test apparatus such as directional couplers, variation in antenna characteristics such as gain and VSWR, and finally VSWR fluctuations due to reflections from the DUT and various room surfaces. A general rule of thumb that takes these adverse affects into account is to increase the size of the power amplifier by a factor of between 2 to 3. This would accommodate the anticipated system losses of between 3 to 5 db. In this specific case of 200V/m, if the DUT is small and one of the TEM cells is used, the power amplifiers specified have sufficient margin. 1 2 The rf fields generated by the products recommended in this application note are either CW or pulse modulated, and occur at a distance of one meter unless otherwise noted. If the application mandates amplitude modulation, additional amplifier power is required to produce undistorted, linear fields. Call Application Engineering at 800-933-8181 for details. The Item numbers match the Block numbers on the enclosed Product Selection Flow Chart.

3 Alternative: Substitute a 200T1G3A for the 100S1G4 and a 200T2G8A for the 200T4G8. Rev090401

Rev090401

TYPICAL PRE-COMPLIANCE SUSCEPTIBILITY TEST SYSTEMS (Use in applications that call for "Leveled" or "Real-Time" testing) RF Source Pre-Amplifier Power Amplifier (Optional) Radiating Antenna Personal Computer w/ GPIB Card Field Monitor Fiber Optic Cable Field Probe HARDWARE LEVELED SYSTEM DeviceUnder Test Anechoic or Shielded Room RF Source Power Amplifier Radiating Antenna Field Probe DeviceUnder Test Personal Computer w/ GPIB Card Field Monitor Fiber Optic Cable Anechoic or Shielded Room GPIB Cable FIELD LEVELED VIA SOFTWARE Figure 1 Rev090401

FULL COMPLIANCE SUSCEPTIBILITY TEST SYSTEM (Use in applications that call for "Substitution Method" testing) RF Source Power Amplifier Dual Directional Coupler Power Meter Radiating Antenna Fiber Optic Cable Field Probe DeviceUnder Test Personal Computer w/ GPIB Card Field Monitor Anechoic or Shielded Room GPIB Cable Figure 2

Rev090401