MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Similar documents
Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-f(-SP)

MINI-PS AC/24DC/1.3

MINI-PS AC/2X15DC/1

MACX MCR-UI-UI-UP(-SP)(-NC)

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

QUINT-PS-24DC/24DC/10

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

QUINT-PS AC/24DC/40

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/40

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Electronic timer CT-SDD.22

Signal conditioner - MACX MCR-UI-UI-NC

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Power supply CP-E 24/2.5

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Power supply CP-D 24/1.3

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

QUINT-PS/ 1AC/24DC/20

Extract from the online catalog

Power supply CP-E 24/0.75

TRIO-PS-2G/1AC/24DC/5

Electronic timer CT-TGD.22

Three-phase monitoring relays

Analog signal converters CC-E I/I

Type CP-S, CP-C & CP-A Switch mode

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 12/2.1

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Power supply CP-T 48/20.0 Primary switch mode power supply

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

PHOENIX CONTACT

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Coupling Relays and Converters

Power supply CP-T 24/20.0 Primary switch mode power supply

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Power supply CP-T 48/5.0 Primary switch mode power supply

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

PHOENIX CONTACT

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

PACT RCP-4000A-UIRO-Dxxx

MODEL IAMA - UNIVERSAL SIGNAL CONDITIONING MODULE

CP-E range Benefits and advantages

08/07/2015

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Three-phase monitoring relay CM-PVE

High precision measurement system for current and voltage IHC-A/B-RM01/03

Electronic timer CT-SDS.22

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

PSD-S AE SM DB/1

CP-T range Product group picture

Three-phase monitoring relays CM-PFE and CM-PFE.2

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Custom "Compact" range with display CD20 Custom Part number

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Switching power supplies CP range, Linear power supplies CP-L range. Content

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Three-phase monitoring relay

PHOENIX CONTACT - 01/2007

Primary switch mode power supplies Product group picture

08/07/2015

SCC-FV01 Frequency Input Module

CP-T range Benefits and advantages

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

02/11/2015

Liquid level monitoring relay CM-ENS.2x

Transcription:

Voltage transducer for AC voltages TERFACE Data sheet 006_en_0 PHOENIX CONTACT 00-0- Description The MCR voltage transducer measures AC voltages in several signal ranges from 0... ±4 V AC to 0... ±30 V AC and converts them to standardized analog signals. The input voltage ranges listed at input terminal blocks to can be varied by ±0% using a calibration potentiometer. The input, output, and power supply are electrically isolated from one another. The voltage transducer is calibrated by default to 0... 4 V AC input and 0... 0 V DC output and is ready for operation when delivered. To use the device with other input or output variables, carry out a ZERO/SPAN adjustment using the potentiometers on the front.. Features 3-way electrical isolation True r.m.s. value measurement Adjustable voltage ranges ZERO/SPAN adjustment ±0%. Method of operation The input circuit divides the AC voltage at terminal blocks to. The resulting signal is electrically isolated and transmitted to the output circuit. This creates the true r.m.s. value and the signal is available at the output as a standardized analog signal..3 Field of application When using the voltage transducer, please ensure that the potential difference between terminal blocks to to ground potential PE or terminal block 8 to ground potential PE U rms does not exceed 440 V (this condition applies to circuits that are not grounded). In AC voltage networks, this potential difference must not exceed U rms = 50 V (this condition applies to circuits that are grounded). When these conditions are met, safe isolation is ensured between the input, output, and power supply. Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/catalog. This data sheet is valid for all products listed on the following page:

Table of contents Description.... Features.... Method of operation....3 Field of application... Table of contents... 3 Ordering data... 3 4 Technical data... 3 5 Block diagram... 5 6 Safety notes... 5 Structure... 5 8 Installation... 6 9 Configuration... 6 9. Selecting the input voltage range... 6 9. Opening the module... 9.3 umper settings... 0 ZERO/SPAN adjustment... 0. Zero point adjustment (ZERO)... 0. Final value adjustment (SPAN)... 006_en_0 PHOENIX CONTACT

3 Ordering data Description Type Order No. Pcs./Pkt. MCR voltage transducer, for AC voltages from 0... 0 V AC to 0... 440 V DC, output signal 0... 0 V/0(4)... 0 ma MCR-VAC-UI-0-DC 803 4 Technical data Voltage measuring input Input voltage range (input resistance) Maximum input voltage 0... 30 V AC (30 kω) 0... 50 V AC (50 kω) 0... 0 V AC (0 kω) 0... 0 V AC (0 kω) 0... 80 V AC (80 kω) 0... 54 V AC (54 kω) 0... 36 V AC (36 kω) 0... 4 V AC (4 kω) 440 V AC (not grounded) 50 V AC (to ground) When these values are observed, safe isolation (EN 508/D EN 508/VDE 060) is ensured between the input, output, and power supply. Voltage output Voltage output signal Maximum voltage output signal Load/output load voltage output Ripple 0... 0 V +5 V > 0 kω < 50 mv PP Current output Current output signal Maximum current output signal Load/output load voltage output Ripple 0(4)... 0 ma +30 ma < 500 Ω < 50 mv PP Power supply Supply voltage range Maximum current consumption 8.5 V DC... 30. V DC < 45 ma General data Measuring principle True r.m.s. value measurement Maximum transmission error <.5% (of final value) Zero adjustment ±0% Span adjustment ±0% Step response (0-90%) 50 ms Degree of protection IP0 Pollution degree Width x height x length.5 mm x 99 mm x 4.5 mm Housing version Polyamide PA, non-reinforced, green 006_en_0 PHOENIX CONTACT 3

Connection data Conductor cross-section, solid 0. mm....5 mm Conductor cross-section, stranded 0. mm....5 mm Stripping length 8 mm Safe isolation according to EN 508 Surge voltage category III Pollution degree Input/output test voltage 3.3 kv (50 Hz, min.) Input/power supply test voltage 3.3 kv (50 Hz, min.) Output/power supply test voltage kv (50 Hz, min.) Rated insulation voltage Input/output Output/power supply 440 V AC, for ungrounded circuits 300 V AC, for grounded circuits 50 V AC Ambient conditions Ambient temperature (operation) Ambient temperature (storage/transport) -5 C... +60 C -40 C... +85 C, no condensation Conformance/approvals Conformance UL, USA/Canada CE-compliant u Conformance with EMC Directive 89/336/EEC Noise immunity according to EN 6000-6- Electrostatic discharge EN 6000-4- 8 kv air discharge Electromagnetic HF field EN 6000-4-3 Amplitude modulation Pulse modulation 3 V/m 3 V/m Fast transients (burst) EN 6000-4-4 Input/output/power supply: kv/5 khz Surge current loads (surge) EN 6000-4-5 Input/output: kv/4 Ω Power supply: 0.5 kv/ Ω Conducted interference EN 6000-4-6 Input/output/power supply: 0 V Noise emission according to EN 6000-6-4 Noise emission according to EN 6000-6-4 EN 550 Class A 006_en_0 PHOENIX CONTACT 4

5 Block diagram 0-30V 0-0V 3 0-80V 0-54V GND Figure 5 6 8 Block diagram for the MCR-VAC-UI-0-DC 6 Safety notes OUT 9 0 3+ 4VDC 4+ 4VDC 5 6 CAUTION Installation, operation, and maintenance may only be carried out by qualified electricians. When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations, must be observed. CAUTION: Electrostatic discharge The module contains components that can be damaged or destroyed by electrostatic discharge. When handling the module, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 6340-5- and EN 6340-5-. Structure 5 4 Figure 5 6 8 3 4 3 MCR-VAC-UI-0-DC MCR-VAC -UI-0 -DC Art. -Nr.: 8 0 3 Location of the elements Supply voltage Output 3 Potentiometer for adjustment 4 Inputs 5 Upper part of the housing can be removed to set the jumpers 6 Universal snap-on foot for EN D rails 0-30V 0-0V 3 0-80V 5 0-54V 6 GND 8 OUT GND GND 0-30V 0-50V 0-0V 0-0V 0-80V 0-54V 0-36V/0-4V GND APPROBATIONEN / APPROVALS 6 +4VDC +4VDC GND 3 GND 3 9 0 + 4VDC + 4VDC 3 4 5 6 006_en_0 PHOENIX CONTACT 5

8 Installation 9 Configuration A B B 3 4 5 6 8 B 0-30V 0-0V 3 0-80V 5 0-54V 6 GND 8 0-3 0-5 0- Figure 3 Mounting/removal Figure 4 Opening the housing The assignment of the connection terminal blocks is shown in the block diagram. The module can be snapped onto all 35 mm D rails according to EN 605. Install the module in suitable housing to meet the requirements for the protection class. Screw connection Insert the wire into the corresponding connection terminal block. Use a screwdriver to tighten the screw in the opening above the connection terminal block. WARNG: Risk of electric shock Never carry out work when voltage is present. NOTE: Module damage due to excess voltage If the voltage signal exceeds the voltage range specified at the input signal terminal block by more than 5%, the input circuit may be damaged. 9. Selecting the input voltage range Input voltage Adjustment range (±0%) [V AC] Input terminal block umper/ setting 0... 30 V (96... 440) 0... 50 V (00... 300) 0... 0 V (36... 04) 3 0... 0 V (96... 44) 4 0... 80 V (64... 96) 5 0... 54 V (43... 65) 6 0... 36 V (8... 43) /setting 0... 4 V (9... 9) /setting (default setting) 006_en_0 PHOENIX CONTACT 6

9. Opening the module Using a screwdriver, release the locked upper part of the housing on both sides. The upper part of the housing and the electronics can now be pulled out approximately 3 cm (see Figure 4 on page 6). 9.3 umper settings Insert the jumpers in slots... 3 according to the required input voltage and the current output. Input voltage: Input umper Position 36 V 4 V Current output: Output umper Position 0... 0 V /3 0... 0 ma /3 4... 0 ma /3 Close the housing again until it engages with a click. Carry out a ZERO/SPAN adjustment each time the input or output range is changed. 0 ZERO/SPAN adjustment Figure 6 Potentiometers 5 6 8 3 4 MCR-VAC-UI-0-DC 0-30V 0-50V 0V MCR-VAC -UI-0 -DC Art. -Nr.: 8 0 3 Location of the potentiometers Allow the module to warm up for 4 minutes before starting the adjustment procedure. The module is calibrated by default to 0... 4 V input and 0... 0 V output. There are two potentiometers on the front of the module for the adjustment: ZERO: Zero point adjustment SPAN: Final value adjustment 0-30V 0-0V 3 0-80V 5 0-54V 6 GND 8 OUT GND GND 9 0 +4VDC +4VDC D 3 + 4VDC + 4VDC 3 4 5 6 36V 4V 3 0-0 4-0 0. Zero point adjustment (ZERO) Connect a calibration device to the input terminal blocks (U ( - ) and GND) and specify a voltage of 0 mv. Set the output signal value using the ZERO potentiometer: Voltage output (0 0 V): U OUT = 0 V Current output (0 0 ma): I OUT = 0 ma Current output (4 0 ma): I OUT = 4 ma 0. Final value adjustment (SPAN) Use the calibration device to specify the maximum voltage used within the input voltage range (see "Selecting the input voltage range" on page 6). Set the output signal value (U OUT = 0 V or I OUT = 0 ma) using the SPAN potentiometer. Figure 5 Location of jumpers... 3 006_en_0 PHOENIX CONTACT GmbH & Co. KG 383 Blomberg Germany Phone: +49-5 35-30 0 PHOENIX CONTACT P.O.Box 400 Harrisburg PA -000 USA Phone: +-944-300 www.phoenixcontact.com