New Product News. Programmable Digital Controller E5AR-T/E5ER-T. One Digital Controller with Up To 32 Programs

Similar documents
Single-phase Voltage Relay

Digital Amplifier Ultrasonic Sensor E4C-UDA Series

Ordering Information. Ratchet Relay G4Q. Model Number Legend


A Revolution in Information Management

Visual Inspection by Digital Solution.

Single-phase Current Relay

CompoNet Gateway Unit for CC-Link

CompoBus/D-type Digital Controller

APPENDIX APPENDIX A 1

NEW. Better Productivity by Standstill and Low-speed Monitoring

F210 Vision Sensor Flow Menus and Macro Capability

Multipoint Temperature Controller

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series

Model Number Structure

Smart Sensor. ZX Series. Not just another idea. A new-generation concept.

Sensor Communications Unit Distributed Sensor Unit E3NW Revolutionize the Workplace Introducing the Next-generation E3NW Sensor Networking Units

Temperature Controllers E5 J

Digital Temperature Controller

Greater Flexibility in Equipment Design

Product Discontinuation Notices

Safety Relay Unit. OFF-delay time

Position Control Units

Model Number Structure

Revolutionize the Workplace Introducing the Next-generation E3NW Sensor Networking Units

FA Wireless SS Terminals

Revolutionize the Workplace Introducing the Next-generation E3NW Sensor Networking Units

OMRON APPLICATION NOTE

Position Control Unit CJ1W-NCF71

Multi-point Temperature Controller

Solid State Pressure Sensors D8M

DIGITAL PROGRAM CONTROLLER

SPST-NO SPDT DPST-NO DPDT

High Performance Process & Temperature Controllers

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

Fluoro plastic housing for highest chemical and detergent resistance

Process displays For standard signals, temperature, resistance measurement

MICRO-CONTROLLER X (48 48 mm)

Fuzzy Temperature Controllers E5AF

F210 Vision Sensor Flow Menus and Macro Capability

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

3. Contact Form A: SPST-NO

SHIMADEN PROGRAMMABLE CONTROLLER

Programmable Digital Controller

MICRO-CONTROLLER X (48 96 mm)

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

Excellent low-cost Process & Temperature Controllers

Digital indicator for panel mounting With multi-function input Model DI25

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

TEL:-3349 FAX:-332 FBR2 SERIES ORDERING INFORMATION [Example] FBR2 S A D2 U P 2 ( CSA) (a) (b) (c) (d) (e) (f ) (g) (h) (a) Series N

Model Number Structure

Model Number Structure

PROGRAMMABLE CONTROLLER

Switch Mode Power Supply

Switch Mode Power Supply

PROGRAM CONTROLLER OUTLINE

E5ER-T. Model Number Structure. Programmable Digital Controller. Model Number Legend

Ramp/Soak Temperature Controller REX-P250

Surprisingly Stable Detection with Your Finger tip

MICRO-CONTROLLER X (96 96 mm)

2 m ZX1-LD50A61 2M ZX1-LD50A81 2M Pre-wired. 50 ± 10 mm

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

NPN PNP NPN PNP NPN PNP

2D Profile Measuring Sensors Ultra Wide Laser Beam & Super High-speed Measurement

MAXIMUM LOAD CURRENT 1 A. 3 : 3 VDC (only AC type) 5 : 5 VDC 12 : 12 VDC 24 : 24 VDC A : AC type D : DC type

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

K3P ENG.qxd 23/10/ Pagina 1

Count/Time Totalizers

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Surprisingly Stable Detection with Your Finger tip

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Phase-sequence Phase-loss Relay

Industry-leading Levels * of Performance Highly Stable Detection

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Fuzzy Temperature Controllers E5EF

SRX. General Description. Features. Module type High-speed Digital Controller SRX. Multi-Zone Space-Saving. High-speed Feedback Control

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

High Performance Fiber Amplifiers with Unmatched Stability and Resolution

DC1010/DC1020/DC1030/DC1040

PCB Footprint Max.Load Coil Voltage Non-Latching part number Single-coil latching part number Standard ground terminal (1GHz)

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

MOS FET Relays G3VM-61G1

SHIMADEN DIGITAL INDICATOR

Temperature Controller

SHIMADEN PROGRAM CONTROLLER

Contact form SPST-NO SPST-NO/SPST-NC Type Model Rated voltage (V) Model Rated voltage (V) AC: 24, 100, 110, 120, 200, 220, 230, 240

Artificial Intelligence Machine Automation Controller NX701-Z 00 / NY5 2-Z 00. Ultimate innovation goes beyond impossible

PID CONTROLLERS LT SERIES

Page H x 96 W x 69.5 D mm (1.89 x 3.78 x 2.74 in)

Industry-leading Levels * of Performance Highly Stable Detection

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Transcription:

New Product News Programmable Digital Controller E5AR-T/E5ER-T One Digital Controller with Up To 32 Programs

A new High-speed, High-precision Digital Controller that is Programmable! A Se To This Digital Controller boasts a sampling time of 50 ms, plus a resolution of 0.01 C 0.01 C for a Pt input. And you can create up to 32 programs containing up to 256 segments total. This type of performance makes a big difference in many applications, such as test equipment where many different settings must be tried. Create up to 32 programs with up to 256 segments total. Coordinated operation for up to four channels with one Digital Controller. Fu 0.01 C; High resolution for Pt input. 0.01 C; To High-speed sampling at 50 ms. Bo To Programmable Digital Controller E5AR-T/E5ER-T

Features Create Up To 32 Programs with Up To 256 Segments Total You can create up to 32 programs with up to segments each, or you can create up to programs with up to 32 segments each. Either way, you get up to a total of 256 segments of programming. This feature is ideal for testing equipment to make a variety Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 Segment 6 0.0 of settings. High-speed and High-resolution Performance Sample at the high speed of 50 ms for 4 channels to achieve stable even for items requiring high-speed response. And, the resolution is 0.01 C for a Pt input. Temperature, humidity, and other factors for ambient testing equipment can be measured, variations detected, and data logged at a high resolution. Stable for items requiring high-speed response. 0.0 Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 Segment 6 50.0 5: 00 5: 00 5: 00 5: 00 5: 00 5: 00 70.0 Time (hours and minutes) 0.0 Segment 1 Segment 2 Segment 3 Segment 4 50.0 5: 00 5: 00 5: 00 5: 00 5: 00 5: 00 High-speed sampling 50 ms Time (hours and minutes) 50.0 5: 00 : 00 : 00 5: 00 Time (hours and minutes) Time Up To 32 Programs Coordinated Operation for Up to Four Channels with One Digital Controller Up to four channels are supported for analog in a compact sized body to contribute to downsizing panels. High-speed startup in a few seconds Easy Settings from a Computer Using the CX-Thermo The CX-Thermo setting software lets you set, edit, and transfer parameters all at once. Four Channels, One Digital Controller RoHS Compliance for World-wide Application Note: Coordinated operation refers to a slave operating using the same program as the master. Available Soon It will soon be possible to easily setup and monitor screens online using the SAP Library.

Applications Semiconductor Test Equipment Topic High-speed, high-precision programmed Solution Achieve optimum semiconductor temperature profiles with high-speed response and high precision. Infrared sensor High Precision Fast Response Programmed Control Furnace Test Equipment Topic High-speed heating and cooling Solution Use high-speed sampling to achieve repeated for temperature increases and decreases of hundreds of degrees in a few second. 0 to 300 C/s 0 to 300 C/s 0 to 300 C/s 0 to 300 C/s 4 Channels Coordinated Operation Fast Response Programmed Control Bonding Equipment Topic Expensive, multifunctional lers had to be used for devices requiring high-speed response, such as ceramic heaters, because economic temperature lers were not available. Solution Improved performance with high-speed sampling (50 ms) Economic and easy to operate Fast Response Programmed Control

Ratings Supply voltage CE marking 0 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz; 24 VDC UL certification 0 to 120 VAC, 50/60 Hz 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 5% to 1% of rated supply voltage Power consumption 22 VA max. (with maximum load) 15 VA/ W max. (with maximum load) Sensor input (See note 3.) Control output Auxiliary output Voltage (pulse) output Current output Relay output Potentiometer input Contact Event input No-contact Remote input Transfer output Control method Indication method Other functions Ambient operating temperature Ambient operating humidity Storage temperature Thermocouple: K, J, T, E, L, U, N, R, S, B, W Platinum resistance thermometer: Pt0 Current input: 4 to 20 ma DC, 0 to 20 ma DC (including remote input) Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to VDC (including remote input) (Input impedance: 150 Ω for current input, approx. 1 MΩ for voltage input) 12 VDC, 40 ma max. with short-circuit protection circuit (E5AR-TQQE3MW-FLK and E5AR-TQQE3MWW-FLK: 21 ma max.) 0 to 20 ma DC, 4 to 20 ma DC; load: 500 Ω max. (including transfer output) (Resolution: Approx. 54,000 for 0 to 20 ma DC; Approx. 43,000 for 4 to 20 ma DC) Position-proportional type (open, closed) N.O., 250 VAC, 1 A (including inrush current) Relay Output: N.O., 250 VAC, 1 A (resistive load) Transistor Output: Maximum load voltage: 30 VDC; Maximum load current: 50 ma; Residual voltage: 1.5 V max.; Leakage current: 0.4 ma max. 0 Ω to 2.5 kω Input ON: 1 kω max.; OFF: 0 kω min. Input ON: Residual voltage of 1.5 V max.; OFF: Leakage current of 0.1 ma max. Short-circuit: Approx. 4 ma Refer to the information on sensor input. Refer to the information on output. 2-PID or ON/OFF Digital setting using front panel keys or setting using serial communications 7-segment digital display and single-lighting indicator Character Height E5AR: PV display: 12. mm; SV display: 7.7 mm; MV display: 7.7 mm, E5ER: PV display: 9.5 mm; SV display: 7.2 mm; MV display: 7.2 mm Depends on model. to 55 C (with no icing or condensation) For 3 years of assured use: to 50 C (with no icing or condensation) 25% to 5% 25 to 65 C (with no icing or condensation) Note 1. Do not use an inverter output as the power supply. 2. The supply voltage (i.e., 0 to 240 VAC or 24 VAC/VDC) depends on the model. Be sure to specify the required type when ordering. 3. The Controller is equipped with multiple sensor input. Temperature input or analog input can be selected with the input type setting switch. There is basic insulation between power supply and input terminals, power supply and output terminals, and input and output terminals. Program Control Functions Number of programs (patterns) 32 (with segments/program) Number of segments (steps) 32 (with programs) Maximum number of segments 256 Segment setting method Segment times Alarm group number specifications Reset operation Startup operation PID groups Alarm function Program status Wait operation Time signals Segment outputs Program status output Number of groups Number of groups Program startup PV start operation Standby Operation end operation Number of event inputs Segment operation Program operation Wait method Wait width setting Number of outputs Number of ON/OFF operations Number of outputs Time setting (Segment set with target value and time.) Gradient setting (Segment set with target value, gradient, and time.) 0 h 0 min to 99 h 59 min 0 min 0 s to 99 min 59 s 0 min 00.0 s to 99 min 59.9 s 4 Set separately for each program. Select either stopping or fixed operation. Select continuing, resetting, manual operation, run mode, or ramp back operation. Set separately for each program (automatic PID group selection also supported). Select from ramp and target. Advance, hold, and back Program repetitions and program links Select from waiting at segment ends and always waiting. Wait width upper limit and lower limit set separately for each program. ON/OFF setting for each segment 6 3 each per output Set separately for each program. ON/OFF set for each segment. Program end output (pulse width can be set) Segment number output Select from segment 1 target value, slope-priority PV start, and time-priority PV start. Standby Select from resetting, continuing at final target value, and fixed. max.

Ordering Information Size 96 96 mm 4 96 mm Control type Basic 2-loop 4-loop Control valve Basic 2-loop Control valve Control mode Standard Heating and cooling 2-loop standard Single-loop heating and cooling Single-loop cascade Single-loop with remote Single-loop proportional 4-loop standard 2-loop heading cooling (See note 3.) Single-loop positionproportional Standard Heating and cooling 2-loop standard Single-loop heating and cooling Single-loop cascade Single-loop with remote Single-loop proportional Single-loop positionproportional Outputs (/transfer) 4 (pulse + pulse/current + 2 current) 4 (2 pulse + 2 pulse/2 current) 4 (4 current) 4 (2 pulse + 2 pulse/2 current) Relay outputs (1 open, 1 closed) Relay outputs (1 open, 1 closed) + 1 current Optional functions Auxiliary outputs (SUB) 4 2 Event inputs 4 4 4 4 4 2 2 Relay outputs (1 open, 1 closed) 2 4 Relay outputs (1 open, 1 closed) + 1 current 4 Serial communications Model E5AR-TQ4B E5AR-TC4B E5AR-TQ43B-FLK E5AR-TC43B-FLK E5AR-TQE3MB-FLK E5AR-TCE3MB-FLK E5AR-TQCE3MB-FLK E5AR-TQ43DW-FLK E5AR-TC43DW-FLK E5AR-TQQE3MW-FLK E5AR-TCCE3MWW-FLK E5AR-TQQE3MWW-FLK E5AR-TPR4DF E5AR-TPRQE3MF-FLK Note 1. Specify the power supply specifications when ordering. Model numbers for 0 to 240 VAC are different from those for 24 VAC/VDC. Models marked with asterisks are available only for 0 to 240 VAC. 2. The outputs are transistor outputs. 3. Only for coordinated operation. (A different program cannot be set for each channel.) 4 E5ER-TQ4B E5ER-TC4B E5ER-TQC43B-FLK E5ER-TQT3DW-FLK E5ER-TCT3DW-FLK E5ER-TPRTDF E5ER-TPRQ43F-FLK The application examples provided in this catalog are for reference only. Check functions and safety of the equipment before use. Never use the products for any application requiring special safety requirements, such as nuclear energy systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, or other application involving serious risk to life or property, without ensuring that the system as a whole has been designed to address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system. Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Control Devices Division H.Q. Analog Controller Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-530 Japan Tel: (1)75-344-700/Fax: (1)75-344-719 Regional Headquarters OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)47-43-7900/Fax: (1)47-43-56 OMRON ASIA PACIFIC PTE. LTD. 3 Clemenceau Avenue, #11-01, UE Square, 239920 Singapore Tel: (65)635-3011/Fax: (65)635-2711 Authorized Distributor: OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel: (31)2356-1-300/Fax: (31)2356-1-3 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Road (M), Shanghai, 200120 China Tel: (6)21-5037-2222/Fax: (6)21-5037-2200 Note: Specifications subject to change without notice. Cat. No. H151-E1-01 Printed in Japan 0706-1M (0706) (C)