NI PXIe Contents. About These Specifications DEVICE SPECIFICATIONS. 3 GHz Ω Multiplexer (SP16T)

Similar documents
Refer to the NI Switches Help at ni.com/manuals for detailed topology information.

NI PXI Contents. About These Specifications DEVICE SPECIFICATIONS GHz Dual Transfer Switch 50 Ω Relay Module

NI PXI Contents DEVICE SPECIFICATIONS. RF Attenuator

PXI Contents. PXI-2585 Specifications. Topology DEVICE SPECIFICATIONS. 10-Channel Multiplexer

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Reconfigurable Device

USRP Contents. Definitions SPECIFICATIONS. Software Defined Radio Reconfigurable Device

USRP Contents. Definitions SPECIFICATIONS. 50 MHz to 2.2 GHz Tunable RF Transceiver

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

PXIe Contents SPECIFICATIONS. RF Amplifier

PXIe Contents SPECIFICATIONS. RF Preselector Module

USRP Contents. Definitions SPECIFICATIONS. 10 MHz to 6 GHz Tunable RF Transceiver

1- or 2-Port, High-Speed, Flexible Data Rate PXI CAN Interface Module

CDA Contents. Definitions SPECIFICATIONS. Clock Distribution Device

NI PXI/PXIe Contents. About These Specifications DEVICE SPECIFICATIONS. Quad 2 1 Terminated Multiplexer

PXI Contents. PXI-2584 Specifications DEVICE SPECIFICATIONS. 300 V CAT II, 600 V CAT I Multiplexers

PXI Contents SPECIFICATIONS. 1.3 GHz RF Analog Signal Generator

PXIe Contents SPECIFICATIONS. 3.3 GHz RF Analog Signal Generator

1- or 2-Port, Software-Selectable PXI CAN Interface Module

PXI Contents SPECIFICATIONS. 6.6 GHz RF Analog Signal Generator

High-Speed/Flexible Data-Rate CAN Characteristics 5 VDC

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

PXIe Contents SPECIFICATIONS. 250 khz to 20 GHz RF Analog Signal Generator

NI PXI/PXIe Contents DEVICE SPECIFICATIONS. 40 A Fault Insertion Unit

NI PXI-2557 Specifications

NI PXI/PXIe Contents DEVICE SPECIFICATIONS. 10 A Fault Insertion Unit

NI PXI/PXIe-2540 Specifications

PXI Contents SPECIFICATIONS. ±20 V, 40 W PXI Source Measure Unit

PXIe Contents. Definitions SPECIFICATIONS. 8.5 GHz Vector Network Analyzer

100 MHz Bandwidth, 12-Bit PXI Waveform Generator

PXI Contents. Definitions SPECIFICATIONS. ±100 V, 2 W Precision PXI Source Measure Unit. These specifications apply to the PXI-4132.

NI PXI/PXIe-2541 Specifications 300 MHz Ω Matrix

Related Information Refer to the NI Switches Help for detailed topology information.

PXIe Contents. Definitions SPECIFICATIONS. 8.5 GHz Vector Network Analyzer

NI PXI-2555 Specifications

SCXI MHz Quad 8x1 50 Ω Multiplexer

This document lists the specifications for the NI PXI The PXI-5900 is a differential amplifier.

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

Note Using the NI 5751/5751B in a manner not described in this document may impair the protection that the NI 5751/5751B provides.

USRP Contents. Definitions SPECIFICATIONS. USRP Software Defined Radio Stand-Alone Device

NI PXI-2521 Specifications 40-Channel DPST Relay Module

4-Channel, ±6 V, 500 ma Precision PXI Source Measure Unit

4-Channel, ±24 V, 150 ma PXI Source Measure Unit

16-Bit, 120 MS/s, 12 Channel DC/16 Channel AC Receiver Adapter Module

4-Channel ±10 V, 100 ma, Precision PXI Source Measure Unit

4-Channel ±10 V, 100 ma, Precision PXI Source Measure Unit

100-SPST (latching), 50-DPST. Refer to the NI Switches Help at ni.com/manuals for detailed topology information.

4-Channel, ±24 V, 150 ma Precision PXI Source Measure Unit

NI PXI-2520 Specifications 80-Channel SPST Relay Module

NI USB Contents DEVICE SPECIFICATIONS. 50 MS/s Bus-Powered USB Oscilloscope

PXIe, 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer,PXI Digital Multimeter

NI roborio. Contents. Processor SPECIFICATIONS. RIO Device for Robotics

Related Information Refer to the NI Switches Help for detailed topology information.

PXIe Contents SPECIFICATIONS. 2-Channel, 60 V, 1 A PXI Programmable Power Supply. These specifications apply to the PXIe-4112.

NI PXI/PXIe-2529 Specifications

PXIe Contents SPECIFICATIONS. ±60 V, 3 A System PXI Source Measure Unit. These specifications apply to the PXIe-4138.

6½-Digit, ±300 V, 1.8 MS/s Isolated Digitizer Included, PCI Digital Multimeter Device

PCI Express, 6½-Digit, ±300 V Digital Multimeter Device

PXIe Contents SPECIFICATIONS. ±200 V, 1 A System PXI Source Measure Unit. These specifications apply to the PXIe-4136.

mmwave Transceiver System

80 MHz Bandwidth, 16-Bit PXI Waveform Generator. These specifications apply to the one-channel and two-channel PXIe-5433.

PXIe Contents SPECIFICATIONS. ±60 V, 3 A Precision System PXI Source Measure Unit. These specifications apply to the PXIe-4139.

NI PXI/PXIe-2527 Specifications

PXIe, 40 MHz Bandwidth, 16-Bit PXI Waveform Generator. These specifications apply to the one-channel and two-channel PXIe-5423.

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

PXIe Contents SPECIFICATIONS. ±200 V, 1 A Precision System PXI Source Measure Unit. These specifications apply to the PXIe-4137.

8-Channel, 12-Bit, 60 MHz PXI Express Oscilloscope

PXI Contents SPECIFICATIONS. 8-Channel, 12-Bit, 60 MHz PXI Oscilloscope

PXIe, 80 MHz Bandwidth, 16-Bit PXI Waveform Generator. These specifications apply to the one-channel and two-channel PXIe-5433.

Specifications are typical and valid from -40 C to +85 C unless otherwise noted. Galvanic isolation between channels and to chassis

PCI Contents SPECIFICATIONS. 8-Channel, 12-Bit, 60 MHz PCI Oscilloscope Device

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

100 MHz, 32-Channel, 5 V PXI Digital Waveform Instrument

PXI Contents SPECIFICATIONS. 1 GHz Bandwidth, 2 GS/s, 8-Bit PXI Oscilloscope

PXIe Contents SPECIFICATIONS. Precision, 10 fa Sensitivity Low-Current PXI Source Measure Unit. These specifications apply to the PXIe-4135.

NI 9770 DATASHEET. 30 khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

GETTING STARTED GUIDE NI Port DeviceNet Module

PXIe Contents SPECIFICATIONS GS/s Baseband I/Q Vector Signal Transceiver

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

NI PXI-2530 Specifications

NI 9881 GETTING STARTED GUIDE. 1-Port CANopen Module

PXIe Contents SPECIFICATIONS. 500 MHz, 2.5 GS/s, 10-Bit PXI Express Oscilloscope

PXIe-6570 DEVICE SPECIFICATIONS. 32-Channel Digital Pattern Instrument

PXI Contents SPECIFICATIONS. 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer, L and C Measurement Support, PXI Digital Multimeter

8-Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

PXI Contents SPECIFICATIONS. 300 MHz Bandwidth, 2 GS/s, 8-Bit PXI Oscilloscope

NI PXIe-5630 Specifications

16 AI (16-Bit, 250 ks/s), 4 DI, 4 DO USB Multifunction I/O Device

NI 9216 DATASHEET. 8 RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

NI 9220 DATASHEET. 16 AI, ±10 V, 16 Bit, 100 ks/s/ch Simultaneous. DSUB or push-in springterminal. 250 Vrms, CAT II, channelto-earth

4-Slot, Extended Temperature, Ethernet CompactDAQ Chassis

8-Slot, Extended Temperature, Ethernet CompactDAQ Chassis

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. may impair the protection the NI USB-7855R provides.

PXIe Contents SPECIFICATIONS. IF Digitizer

PXIe Contents SPECIFICATIONS. 1.5 GHz, 5 GS/s, 10-Bit PXI Express Oscilloscope

GETTING STARTED GUIDE NI Port, High-Speed CAN Module. Français Deutsch 日本語한국어简体中文. ni.com/manuals

NI 9207 DATASHEET. 16 AI, ±20 ma/±10 V, 24 Bit, 500 S/s Aggregate

GETTING STARTED GUIDE NI C Series GPS Synchronization Module

NI PXI/PXIe-2532 Specifications

Transcription:

DEVICE SPECIFICATIONS NI PXIe-2748 3 GHz 16 1 50 Ω Multiplexer (SP16T) This document lists specifications for the NI PXIe-2748 (NI 2748) multiplexer module. All specifications are subject to change without notice. Visit ni.com/manuals for the most current specifications. Topology 16 1 multiplexer Contents About These Specifications... 1 Input Characteristics... 2 RF Performance Characteristics...3 Dynamic Characteristics... 4 Physical Characteristics... 5 Environment...5 Shock and Vibration...5 Diagrams... 5 Accessories...7 Compliance and Certifications...8 Safety... 8 Electromagnetic Compatibility... 8 CE Compliance... 9 Online Product Certification... 9 Environmental Management... 9 About These Specifications Specifications characterize the warranted performance of the instrument under the stated operating conditions. Typical Specifications are specifications met by the majority of the instrument under the stated operating conditions and are tested at 23 C ambient temperature. Typical specifications are not warranted. All voltages are specified in DC, AC pk, or a combination unless otherwise specified. Caution The protection provided by the NI 2748 can be impaired if it is used in a manner not described in this document.

Input Characteristics All input characteristics are DC, AC rms, or a combination unless otherwise specified. Maximum switching voltage 30 V Maximum switching current 0.5 A (per channel) Maximum carry current 0.5 A (per channel) Maximum RF power 10 W Caution The switching power is limited by the maximum switching current and the maximum voltage. Channel-to-common switching power must not exceed 10 W. Note National Instruments recommends against switching active RF signals. As a relay actuates, the channel is momentarily unterminated. Some RF sources can be damaged by reflections if their outputs are not properly terminated. Refer to your RF source documentation for more information. Note Switching active RF signals below 0 dbm may degrade signal integrity and decrease relay life. For more information about switching active RF signals, visit ni.com/info and enter Info Code RFSwitching. Typical DC path resistance Initial <1 Ω End-of-life 2 Ω Path resistance is a combination of relay contact resistance and trace resistance. Contact resistance typically remains low for the life of a relay. At the end of relay life, the contact resistance rises rapidly above 1.0 Ω. 2 ni.com NI PXIe-2748 Specifications

RF Performance Characteristics Characteristic impedance (Z 0 ) 50 Ω nominal Insertion loss 1 GHz 1.5 db 3 GHz 3 db Voltage standing wave ratio (VSWR) 1 GHz 1.4 3 GHz 1.6 Typical isolation 1 GHz >60 db 3 GHz >40 db Typical channel-to-channel skew <160 ps Refer to the following figures for typical insertion loss, typical VSWR, and typical isolation, respectively. Figure 1. Typical Insertion Loss Frequency (GHz) 0.00E+00 0 0.5 1 1.5 2 2.5 3 5.00E 01 Typical Insertion Loss 1.00E+00 1.50E+00 2.00E+00 2.50E+00 3.00E+00 NI PXIe-2748 Specifications National Instruments 3

Figure 2. Typical VSWR 1.50E+00 1.45E+00 1.40E+00 1.35E+00 Typical VSWR 1.30E+00 1.25E+00 1.20E+00 1.15E+00 1.10E+00 1.05E+00 1.00E+00 0 0.5 1 1.5 2 2.5 3 Frequency (GHz) Figure 3. Typical Isolation 0 10 Frequency (GHz) 0 1 2 3 4 20 Typical Isolation 30 40 50 60 70 80 90 100 Dynamic Characteristics Maximum relay operate time 10 ms Note Certain applications may require additional time for proper settling. Refer to the NI Switches Help at ni.com/manuals for more information about including additional settling time. Expected mechanical relay life 1 10 7 cycles 4 ni.com NI PXIe-2748 Specifications

Physical Characteristics Relay type Electromechanical, latching I/O connectors 17 MCX jacks, gold plated PXI Express power requirement 3.96 W at 3.3 V, 0.2 W at 12 V Dimensions (L W H) 3U, one slot, PXI/cPCI module 21.6 cm 2.0 cm 13.0 cm (8.5 in. 0.8 in. 5.1 in.) Weight 330 g (11.30 oz) Environment Operating temperature 0 C to 55 C Storage temperature -40 C to 70 C Relative humidity 5% to 85%, noncondensing Pollution Degree 2 Maximum altitude 2,000 m Indoor use only. Shock and Vibration Operational Shock 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) Random Vibration Operating 5 Hz to 500 Hz, 0.3 g rms Nonoperating 5 Hz to 500 Hz, 2.4 g rms (Tested in accordance with IEC 60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) Diagrams The following figure shows the NI PXIe-2748 power-on state. NI PXIe-2748 Specifications National Instruments 5

Figure 4. NI PXIe-2748 Power-On State 0 1 2 3 4 5 6 7 COM 8 9 10 11 12 13 14 15 The following figure shows the NI PXIe-2748 front panel connector. 6 ni.com NI PXIe-2748 Specifications

Figure 5. NI PXIe-2748 Front Panel 3 GHz 16 x 1 50 Ω Multiplexer 0 1 2 3 8 9 10 11 COM 4 5 6 7 12 13 14 15 MAX 10W Accessories Visit ni.com for more information about the following accessories. NI PXIe-2748 Specifications National Instruments 7

Table 1. NI Accessories for the NI PXIe-2748 Accessory Length Part Number MCX-MCX cable 0.3 m 188374-0R3 MCX-MCX cable 1.0 m 188374-01 MCX-BNC cable 0.3 m 188375-0R3 MCX-BNC cable 1.0 m 188375-01 MCX-SMB cable 0.3 m 188376-0R3 MCX-SMB cable 1.0 m 188376-01 MCX-SMA cable 0.3 m 188377-0R3 MCX-SMA cable 1.0 m 188377-01 Compliance and Certifications Safety This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions EN 55022 (CISPR 22): Class A emissions EN 55024 (CISPR 24): Immunity AS/NZS CISPR 11: Group 1, Class A emissions AS/NZS CISPR 22: Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, 8 ni.com NI PXIe-2748 Specifications

Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note For EMC declarations, certifications, and additional information, refer to the Online Product Certification section. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: 2014/35/EU; Low-Voltage Directive (safety) 2014/30/EU; Electromagnetic Compatibility Directive (EMC) Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/ certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee. 电子信息产品污染控制管理办法 ( 中国 RoHS) 中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物质指令 (RoHS) 关于 National Instruments 中国 RoHS 合规性信息, 请登录 ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) NI PXIe-2748 Specifications National Instruments 9

Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2015 National Instruments. All rights reserved. 376209A-01 Jun15