Use of application-optimised type 1 combined arresters in low-voltage installations

Similar documents
DEHN protects Pipelines. Cathodic Corrosion Protection Solutions.

7P Series - Surge Protection Device (SPD) Features 7P P P

Testing. of portable earthing and short-circuiting devices. Contents. Translated White Paper

6. Internal lightning protection

Red/Line Selection Guide Surge Protection for Power Supply Systems.

PRACTICAL GUIDE. Low-voltage power systems Protection against overvoltages

Surge Protection Device (SPD) 7P

2007 DEHN + SÖHNE / protected by ISO EXFS / 5392

BASIC PROBLEMS AND SOLUTION OF THE ENCAPSULATION OF A LOW VOLTAGE SPARK GAP WITH ARC SPLITTER CHAMBER

The innovation in lightning protection High-voltage-resistant, insulated HVI Conductor

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

Transformers connected via a cable Overvoltage protection

VBS TBS KTS BSS LFS UFS

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

ITU-T K.98. Overvoltage protection guide for telecommunication equipment installed in customer premises SERIES K: PROTECTION AGAINST INTERFERENCE

Coordination of surge arresters in DC 3 kv railway traction system field tests

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

MINI-PS AC/24DC/1.3

Precautions to be considered for use of surge arresters tested according to Class 1 of IEC

Technical features table for miniature circuit-breakers SH 200 Series

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range

Reliable System Solutions for Isolated Air-Termination Systems.

Modular arc fault protection system DEHNarc

iprd, iprd IT surge arresters Type 2 or 3 LV withdrawable surge arresters

Residual Current Operated Circuit-Breakers (RCCBs)

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

I -limiter The world s fastest switching device

Tab 8 Surge Arresters

DEHN + SÖHNE. DEHNiso Distance Holder: The Modular Lightning Protection System.

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

Type CP-S, CP-C & CP-A Switch mode

QUINT-PS/ 3AC/24DC/10

IMP/007/011 - Code of Practice for the Application of Lightning Protection

Low voltage products in high altitudes

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Capacitor Switching Contactors

Protection of low power mains against pulse power of natural lightning using spark gap arresters. Abstract

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

7 o/c4 - To meet the requirements of BS 7671, all fault current protective devices without back-up protection on the supply side must be capable of:

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Protection against unacceptable voltages in railway systems

TFS / KFSU: Isolating spark gaps with plastic coating and 2 connections (Rd 10 mm) made of stainless

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

ITU-T K.97. Lightning protection of distributed base stations SERIES K: PROTECTION AGAINST INTERFERENCE. Recommendation ITU-T K.

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Residual Current Operated Circuit-Breakers (RCCBs)

MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT

TECHNICAL NOTE 2.0. Overvoltages origin and magnitudes Overvoltage protection

Power supply CP-T 48/20.0 Primary switch mode power supply

Solid State Relay, 1-phase

Selection of MO surge arresters Overvoltage protection

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Three-phase monitoring relay CM-PVE

QUINT-PS/ 3AC/24DC/40

OVERVOLTAGE PROTECTION. Dimensioning, testing and application of metal oxide surge arresters in low-voltage power distribution systems

ABSTRACTS of SESSION 6

Power supply CP-T 24/20.0 Primary switch mode power supply

Type DMX-N Surge Arresters Maximum System Voltage 2 to 36 kv

Electronic timer CT-SDS.22

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

LED Driver Compact fixed output

Transformers, Power Supply Units and Socket Outlets

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Power supply CP-T 48/5.0 Primary switch mode power supply

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Spark Gap Surge Protectors For Lv Mains

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

ITU-T K.120. Lightning protection and earthing of a miniature base station SERIES K: PROTECTION AGAINST INTERFERENCE. Recommendation ITU-T K.

Surge arrester. 2-electrode arrester B88069X3433B251 V87A-A600XP1

Three-phase monitoring relays CM-PFE and CM-PFE.2

Company main topic [ Product ] TracFeed GR. English. Diode Rectifiers. Made in Germany

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Earthing of Electrical Devices and Safety

Three-phase monitoring relays

Switching power supplies CP range, Linear power supplies CP-L range. Content

Overcurrent Protection / 7SJ45

Modeling insulation in high-voltage substations

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Power supply CP-T 24/10.0 Primary switch mode power supply

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Soft starters with internal by-pass

Power supply CP-T 24/40.0 Primary switch mode power supply

SIOV metal oxide varistors

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PBE

Insulation Co-ordination For HVDC Station

Technical Specification

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

QUINT-PS/ 1AC/24DC/20

Transcription:

Use of application-optimised type 1 combined arresters White Paper Contents Use of prewired and application-optimised DEHNshield combined arresters with spark gap technology Examples: Under-road radiators at the entrance to underground car parks Lamp posts CCTV systems Charging stations for electric vehicles Outdoor socket outlets Barrier system www.dehn-international.com

Use of application-optimised type 1 combined arresters White Paper Use of application-optimised DEHNshield combined arresters When lightning hits the external lightning protection system of a building, the lightning current is shared between the cables entering the building and the building s earth electrode. To prevent dangerous sparking in the structure to be protected, the IEC 62305 (EN 62305) lightning protection standard encourages to take internal lightning protection measures when installing an external lightning protection system. The standard also requires to establish lightning equipotential bonding by connecting all metal parts directly or, in case of power supply and information technology systems, indirectly via surge protective devices in the structure. The surge protective devices referred to in this standard are type 1 lightning current arresters with an adequate voltage protection level. Application-optimised DEHNshield type 1 combined arresters combine lightning equipotential bonding up to 50 ka (10/350 µs) lightning impulse currents and surge protection in a single arrester stage. This clearly distinguishes DEHNshield from the currently available varistor-based arresters of this application and performance class. DEHNshield arresters also provide optimal protection for buildings without external lightning protection system where power is supplied through an overhead line and type 1 arresters are to be installed in the service entrance box according to the German VdS 2031 guideline. DEHNshield combined arresters can be used without additional backup fuse if the installation is protected by backup fuses up to 160 A. The follow-current-limiting spark gap technology ensures selectivity even with respect to low-value fuses (35 A gl/gg), meaning that upstream fuses are not tripped by mains follow currents. If lightning hits external equipment (for example a camera mast), partial lightning currents will flow into the building via the earth electrode of the external equipment and the connecting cables. In this context, it must be observed that these lightning currents flowing into the building will not overload the surge protective device (SPD) installed in the building. Due to their technical parameters which are suited for use in simple and compact electrical installations, DEHNshield arresters are an ideal solution for this field of application (Figure 1). What is understood by application-optimised use? A type 1 arrester installed at the entrance point into the building must be capable of carrying the partial lightning currents described above. Type 2 and / or type 3 arresters downstream of the entrance point into the building must be energy-coordinated with this type 1 arrester. The follow current limiting and application-optimised DEHNshield combined arrester with spark gap technology (type 1 SPD) fulfils all these requirements. Thanks to its wave breaker function, DEHNshield is capable of protecting terminal equipment and thus ensures energy coordination Figure 1 Prewired and application-optimised DEHNshield combined arrester with spark gap technology with type 2 or type 3 arresters (Figure 1). Varistor-based type 1 arresters are typically not suited for energy coordination. DEHNshield combined arresters allow cost-optimised and application-specific design and configuration matched to a particular application in line with recognised standards. As space for retrofitting is confined, DEHNshield allows to establish lightning equipotential bonding wherever space is restricted. To this end, however, the parameters of the installation must be observed as is the case when planning new installations and it must be checked whether DEHNshield can be used. To make the field of application of DEHNshield more transparent, some sample applications are given in the following figures. Sample applications in Figure 2 In order to reduce lightning currents, equipment must be directly connected to earth electrodes at points where direct lightning strikes are likely to occur (LPZ 0 A ) such as masts with video cameras, lamp posts and under-road radiators. Cameras are frequently used for safety-related evaluation (monitoring systems) and lamp posts are in many cases essential to ensure personal protection (e.g. escape route lighting). Therefore, the required lightning protection measures must be taken in both cases to ensure full protection. The situation is similar for under-road radiators, except that the area in front of or next to the building is particularly prone to lightning strikes. To ensure personal protection (slip hazard in case of steep entrances and exits of e.g. underground car parks), failure of the heating system as a result of lightning strikes or surges must be minimised. The earth electrodes of these pieces of equipment must be interconnected. If this connection is performed in contact with the ground (Supplement 1 of the German DIN EN 62305-3 2

Use of application-optimised type 1 combined arresters White Paper DNO kwh SEB MEB under-road radiator E Figure 2a CCTV system lamp post E E DNO kwh SEB MEB interconnection of earth electrodes Figure 2b SEB: Service Entrance Box MEB: Main Earthing Busbar LPZ: Lightning Protection Zone DNO: Distribution Network Operator earth electrodes interconnected in a defined way (to ensure that they are capable of carrying lightning currents) earth electrodes interconnected in an undefined way No. in Fig. Surge protective device Part No. DEHNventil modular DV M TNS 255 (TN-S systems) or 951 400 DEHNventil modular DV M TT 255 (TT systems) or 951 310 DEHNshield DSH TNS 255 (TN-S systems) or 941 400 DEHNshield DSH TT 255 (TT systems) or 941 310 DEHNshield DSH TN 255 (single-phase TN systems) or 941 200 DEHNshield DSH TT 2P 255 (single-phase TT and TN systems) 941 110 DEHNguard modular DG M TNS 275 (TN-S systems) or 952 400 DEHNguard modular DG M TT 275 (TT systems) or 952 310 DEHNguard modular DG M TN 275 (TN systems) or 952 200 DEHNguard modular DG M TT 2P 275 (single-phase TT and TN systems) 952 110 Figure 2 Application-optimised use of DEHNshield with reference to an under-road radiator at the entrance to an underground car park (2a), a lamp post and a CCTV system (2b) 3

Use of application-optimised type 1 combined arresters White Paper outdoor socket outlet or charging station for electric vehicles outdoor socket outlet or charging station for electric vehicles E E DNO kwh SEB MEB Figure 3a air-termination rod barrier system E DNO kwh SEB MEB Figure 3b SEB: Service Entrance Box MEB: Main Earthing Busbar LPZ: Lightning Protection Zone DNO: Distribution Network Operator earth electrodes interconnected in a defined way (to ensure that they are capable of carrying lightning currents) earth electrodes interconnected in an undefined way No. in Fig. Surge protective device Part No. DEHNventil modular DV M TNS 255 (TN-S systems) or 951 400 DEHNventil modular DV M TT 255 (TT systems) or 951 310 DEHNshield DSH TNS 255 (TN-S systems) or 941 400 DEHNshield DSH TT 255 (TT systems) or 941 310 DEHNshield DSH TN 255 (single-phase TN systems) or 941 200 DEHNshield DSH TT 2P 255 (single-phase TT and TN systems) 941 110 DEHNguard modular DG M TNS 275 (TN-S systems) or 952 400 DEHNguard modular DG M TT 275 (TT systems) or 952 310 DEHNguard modular DG M TN 275 (TN systems) or 952 200 DEHNguard modular DG M TT 2P 275 (single-phase TT and TN systems) 952 110 Figure 3 Application-optimised use of DEHNshield with reference to a charging station for electric vehicles or an outdoor socket outlet (3a) and a barrier system (3b) 4

Use of application-optimised type 1 combined arresters White Paper (VDE 0185-305-3) standard) and possibly extends over the entire cable route up to the building, damage to the cable is prevented if lightning strikes the ground. Sample applications in Figure 3 If lightning strikes to external equipment can be ruled out (LPZ 0 B ), partial lightning currents still pose a risk when lightning hits the external lightning protection system of the main building. In this case, partial lightning currents may travel through the cables to equipment with a remote earth potential (charging stations for electric vehicles, outdoor socket outlets and barrier systems protected by air-termination rods). To ensure safe traffic flow, future concepts of charging stations for electric vehicles require high availability as is the case with petrol stations. Since these charging stations are located outside buildings and are equipped with sensitive electrical systems, lightning protection is vital to minimise interference with the installation as a result of lightning strikes and surges. Barrier systems have been protected against lightning strikes and surges over decades to ensure faultless operation. As far as outdoor socket outlets are concerned, lightning and surge protection measures may have to be taken at the design stage, depending on their intended use. An earth electrode is also required for these pieces of equipment to conduct the lightning currents flowing via DEHNshield from the building to earth. Also in this case, the interconnection of earth electrodes is recommended, but not mandatory. Equipment attached to the building, which is directly connected to the earth-termination system of the building and the supply line, can be protected by type 2 arresters. An application-optimised type 1 arrester such as DEHNshield is suitable for protecting specific applications. This, however, requires that the described measures are implemented consistently and that the technical parameters of the installation to be protected are observed. A properly functioning earth-termination system, for example, is one of the most important aspects for the overall system. 5

DEHNventil DV M TT 255 (951 310) Prewired spark-gap-based type 1 and type 2 combined lightning current and surge arrester consisting of a base part and plug-in protection modules Maximum system availability due to RADAX Flow follow current limitation Capable of protecting terminal equipment Basic circuit diagram DV M TT 255 Dimension drawing DV M TT 255 Modular combined lightning current and surge arrester for TT and TN-S systems ("3+1" circuit). Type DV M TT 255 Part No. 951 310 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 5 m) type 1 + type 2 + type 3 230 / 400 V (50 / 60 Hz) Max. continuous operating a.c. voltage [L-N] (U C ) 264 V (50 / 60 Hz) Max. continuous operating a.c. voltage [N-PE] (U C (N-PE) ) 255 V (50 / 60 Hz) Lightning impulse current (10/350 µs) [L1+L2+L3+N-PE] (I total ) 100 ka Specific energy [L1+L2+L3+N-PE] (W/R) 2.50 MJ/ohms Lightning impulse current (10/350 µs) [L-N]/[N-PE] (I imp ) 25 / 100 ka Specific energy [L-N]/[N-PE] (W/R) 156.25 kj/ohms / 2.50 MJ/ohms Nominal discharge current (8/20 µs) [L-N]/[N-PE] (I n ) 25 / 100 ka Voltage protection level [L-N]/[N-PE] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability [L-N]/[N-PE] (I fi ) 50 ka rms / 100 A rms Follow current limitation / Selectivity no tripping of a 20 A gl/gg fuse up to 50 ka rms (prosp.) Response time (t A ) 100 ns Max. backup fuse (L) up to I K = 50 ka rms 315 A gg Max. backup fuse (L-L') 125 A gg 440 V / 120 min. withstand Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 1200 V / 200 ms withstand Operating temperature range [parallel] / [series] (T U ) -40 C... +80 C / -40 C... +60 C Cross-sectional area (L1, L1', L2, L2', L3, L3', N, N', PE, 9) (min.) 10 mm 2 solid / flexible Cross-sectional area (L1, L2, L3, N, PE) (max.) 50 mm 2 stranded / 35 mm 2 flexible Cross-sectional area (L1', L2', L3', N', 9) (max.) Capacity 8 module(s), DIN 43880 KEMA, VDE, UL, VdS Use in switchgear installations with prospective short-circuit Extended technical data: currents of more than 50 ka rms (tested by the German VDE) Max. prospective short-circuit current 100 ka rms (220 ka peak ) Limitation / Extinction of mains follow currents up to 100 ka rms (220 ka peak ) Max. backup fuse (L) up to I K = 100 ka rms 315 A gl/gg Weight 1,27 kg GTIN 4013364108172 PU 1 pc(s) 6

DEHNventil DV M TNS 255 (951 400) Prewired spark-gap-based type 1 and type 2 combined lightning current and surge arrester consisting of a base part and plug-in protection modules Maximum system availability due to RADAX Flow follow current limitation Capable of protecting terminal equipment Basic circuit diagram DV M TNS 255 Dimension drawing DV M TNS 255 Modular combined lightning current and surge arrester for TN-S systems. Type DV M TNS 255 Part No. 951 400 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 5 m) type 1 + type 2 + type 3 Max. continuous operating a.c. voltage (U C ) Lightning impulse current (10/350 µs) [L1+L2+L3+N-PE] (I total ) Specific energy [L1+L2+L3+N-PE] (W/R) Lightning impulse current (10/350 µs) [L, N-PE] (I imp ) Specific energy [L,N-PE] (W/R) 230 / 400 V (50 / 60 Hz) 264 V (50 / 60 Hz) 100 ka 2.50 MJ/ohms 25 ka 156.25 kj/ohms Nominal discharge current (8/20 µs) [L/N-PE]/[L1+L2+L3+N-PE] (I n ) 25 / 100 ka Voltage protection level [L-PE]/[N-PE] (U P ) Follow current extinguishing capability a.c. (I fi ) Follow current limitation / Selectivity Response time (t A ) Max. backup fuse (L) up to I K = 50 ka rms Max. backup fuse (L-L') 1.5 / 1.5 kv 50 ka rms no tripping of a 20 A gl/gg fuse up to 50 ka rms (prosp.) 100 ns 315 A gg 125 A gg 440 V / 120 min. withstand Operating temperature range [parallel] / [series] (T U ) -40 C... +80 C / -40 C... +60 C Cross-sectional area (L1, L1', L2, L2', L3, L3', N, N', PE, 9) (min.) Cross-sectional area (L1, L2, L3, N, PE) (max.) Cross-sectional area (L1', L2', L3', N', 9) (max.) 10 mm 2 solid / flexible 50 mm 2 stranded / 35 mm 2 flexible Capacity 8 module(s), DIN 43880 Extended technical data: KEMA, VDE, UL, VdS Use in switchgear installations with prospective short-circuit currents of more than 50 ka rms (tested by the German VDE) Max. prospective short-circuit current 100 ka rms (220 ka peak ) Limitation / Extinction of mains follow currents up to 100 ka rms (220 ka peak ) Max. backup fuse (L) up to I K = 100 ka rms 315 A gl/gg Weight 1,35 kg GTIN 4013364108158 PU 1 pc(s) 7

DEHNshield DSH TT 2P 255 (941 110) Application-optimised and prewired spark-gap-based type 1 and type 2 combined lightning current and surge arrester Space-saving arrester for compact and simply equipped electrical installations with reduced technical requirements Capable of protecting terminal equipment Basic circuit diagram DSH TT 2P 255 Dimension drawing DSH TT 2P 255 Application-optimised and prewired combined lightning current and surge arrester for single-phase TT and TN-S systems ("1+1" circuit). Type DSH TT 2P 255 Part No. 941 110 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 5 m) type 1 + type 2 + type 3 Max. continuous operating a.c. voltage (U C ) 230 V (50 / 60 Hz) 255 V (50 / 60 Hz) Lightning impulse current (10/350 µs) [L+N-PE] (I total ) 25 ka Specific energy [L+N-PE] (W/R) 156.25 kj/ohms Lightning impulse current (10/350 µs) [L-N]/[N-PE] (I imp ) 12.5 / 25 ka Specific energy [L-N]/[N-PE] (W/R) 39.06 / 156.25 kj/ohms Nominal discharge current (8/20 µs) [L-N]/[N-PE] (I n ) 12.5 / 25 ka Voltage protection level [L-N]/[N-PE] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability [L-N]/[N-PE] (I fi ) Follow current limitation / Selectivity 25 ka rms / 100 A rms no tripping of a 32 A gl/gg fuse up to 25 ka rms (prosp.) Response time (t A ) 100 ns Max. mains-side overcurrent protection 160 A gl/gg Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 440 V / 120 min. withstand 1200 V / 200 ms withstand Operating temperature range (T U ) -40 C... +80 C Cross-sectional area (L, N, PE, 9) (min.) Cross-sectional area (L, N, PE, 9) (max.) 1.5 mm 2 solid / flexible Capacity 2 module(s), DIN 43880 KEMA, VDE, UL Weight 275 g GTIN 4013364137899 PU 1 pc(s) 8

DEHNshield DSH TN 255 (941 200) Application-optimised and prewired spark-gap-based type 1 and type 2 combined lightning current and surge arrester Space-saving arrester for compact and simply equipped electrical installations with reduced technical requirements Capable of protecting terminal equipment Basic circuit diagram DSH TN 255 Dimension drawing DSH TN 255 Application-optimised and prewired combined lightning current and surge arrester for single-phase TN systems. Type DSH TN 255 Part No. 941 200 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 5 m) type 1 + type 2 + type 3 Max. continuous operating a.c. voltage (U C ) 230 V (50 / 60 Hz) 255 V (50 / 60 Hz) Lightning impulse current (10/350 µs) [L+N-PE] (I total ) 25 ka Specific energy [L+N-PE] (W/R) 156.25 kj/ohms Lightning impulse current (10/350 µs) [L, N-PE] (I imp ) 12.5 ka Specific energy [L,N-PE] (W/R) 39.06 kj/ohms Nominal discharge current (8/20 µs) [L/N-PE]/[L+N-PE] (I n ) 12.5 / 25 ka Voltage protection level [L-PE]/[N-PE] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability a.c. (I fi ) 25 ka rms Follow current limitation / Selectivity no tripping of a 32 A gl/gg fuse up to 25 ka rms (prosp.) Response time (t A ) 100 ns Max. mains-side overcurrent protection 160 A gl/gg 440 V / 120 min. withstand Operating temperature range (T U ) -40 C... +80 C Cross-sectional area (L, N, PE, 9) (min.) Cross-sectional area (L, N, PE, 9) (max.) 1.5 mm 2 solid / flexible Capacity 2 module(s), DIN 43880 KEMA, VDE, UL Weight 250 g GTIN 4013364138209 PU 1 pc(s) 9

DEHNshield DSH TT 255 (941 310) Application-optimised and prewired spark-gap-based type 1 and type 2 combined lightning current and surge arrester Space-saving arrester for compact and simply equipped electrical installations with reduced technical requirements Capable of protecting terminal equipment Basic circuit diagram DSH TT 255 Dimension drawing DSH TT 255 Application-optimised and prewired combined lightning current and surge arrester for TT and TN-S systems ("3+1" circuit). Type DSH TT 255 Part No. 941 310 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 5 m) type 1 + type 2 + type 3 Max. continuous operating a.c. voltage (U C ) 230 / 400 V (50 / 60 Hz) 255 V (50 / 60 Hz) Lightning impulse current (10/350 µs) [L1+L2+L3+N-PE] (I total ) 50 ka Specific energy [L1+L2+L3+N-PE] (W/R) 625.00 kj/ohms Lightning impulse current (10/350 µs) [L-N]/[N-PE] (I imp ) 12.5 / 50 ka Specific energy [L-N]/[N-PE] (W/R) 39.06 / 625.00 kj/ohms Nominal discharge current (8/20 µs) [L-N]/[N-PE] (I n ) 12.5 / 50 ka Voltage protection level [L-N]/[N-PE] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability [L-N]/[N-PE] (I fi ) Follow current limitation / Selectivity 25 ka rms / 100 A rms no tripping of a 32 A gl/gg fuse up to 25 ka rms (prosp.) Response time (t A ) 100 ns Max. mains-side overcurrent protection 160 A gl/gg Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 440 V / 120 min. withstand 1200 V / 200 ms withstand Operating temperature range (T U ) -40 C... +80 C Cross-sectional area (L1, L2, L3, N, PE, 9) (min.) Cross-sectional area (L1, L2, L3, N, PE, 9) (max.) 1.5 mm 2 solid / flexible Capacity 4 module(s), DIN 43880 KEMA, VDE, UL Weight 480 g GTIN 4013364131798 PU 1 pc(s) 10

DEHNshield DSH TNS 255 (941 400) Application-optimised and prewired type 1 and type 2 spark-gap-based combined lightning current and surge arrester Space-saving arrester for compact and simply equipped electrical installations with reduced technical requirements Capable of protecting terminal equipment Basic circuit diagram DSH TNS 255 Dimension drawing DSH TNS 255 Application-optimised and prewired combined lightning current and surge arrester for TN-S systems. Type DSH TNS 255 Part No. 941 400 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 5 m) type 1 + type 2 + type 3 Max. continuous operating a.c. voltage (U C ) 230 / 400 V (50 / 60 Hz) 255 (50 / 60 Hz) Lightning impulse current (10/350 µs) [L1+L2+L3+N-PE] (I total ) 50 ka Specific energy [L1+L2+L3+N-PE] (W/R) 625.00 kj/ohms Lightning impulse current (10/350 µs) [L, N-PE] (I imp ) 12.5 ka Specific energy [L,N-PE] (W/R) 39.06 kj/ohms Nominal discharge current (8/20 µs) [L/N-PE]/[L1+L2+L3+N-PE] (I n ) 12.5 / 50 ka Voltage protection level [L-PE]/[N-PE] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability a.c. (I fi ) 25 ka rms Follow current limitation / Selectivity no tripping of a 32 A gl/gg fuse up to 25 ka rms (prosp.) Response time (t A ) 100 ns Max. mains-side overcurrent protection 160 A gl/gg 440 V / 120 min. withstand Operating temperature range (T U ) -40 C... +80 C Cross-sectional area (L1, L2, L3, N, PE, 9) (min.) Cross-sectional area (L1, L2, L3, N, PE, 9) (max.) 1.5 mm 2 solid / flexible Capacity 4 module(s), DIN 43880 KEMA, VDE, UL Weight 525 g GTIN 4013364133563 PU 1 pc(s) 11

DEHNguard DG M TT 2P 275 (952 110) Prewired complete unit consisting of a base part and plug-in protection modules High discharge capacity due to heavy-duty zinc oxide varistors / spark gaps High reliability due to "Thermo Dynamic Control" SPD monitoring device Basic circuit diagram DG M TT 2P 275 Dimension drawing DG M TT 2P 275 Modular surge arrester for use in single-phase TT and TN systems ("1+1" circuit). Type DG M TT 2P 275 Part No. 952 110 type 2 / class II 230 V (50 / 60 Hz) Max. continuous operating a.c. voltage [L-N] (U C ) 275 V (50 / 60 Hz) Max. continuous operating a.c. voltage [N-PE] (U C ) 255 V (50 / 60 Hz) Nominal discharge current (8/20 µs) (I n ) 20 ka Max. discharge current (8/20 µs) (I max ) 40 ka Lightning impulse current (10/350 µs) [N-PE] (I imp ) 12 ka Voltage protection level [L-N] (U P ) 1.5 kv Voltage protection level [L-N] at 5 ka (U P ) 1 kv Voltage protection level [N-PE] (U P ) 1.5 kv Follow current extinguishing capability [N-PE] (I fi ) 100 A rms Response time [L-N] (t A ) 25 ns Response time [N-PE] (t A ) 100 ns Max. mains-side overcurrent protection 125 A gg Short-circuit withstand capability for max. mains-side overcurrent protection (I SCCR ) 50 ka rms 335 V / 5 sec. withstand 440 V / 120 min. safe failure Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 1200 V / 200 ms withstand Operating temperature range (T U ) -40 C... +80 C Cross-sectional area (min.) 1.5 mm 2 solid / flexible Cross-sectional area (max.) Capacity 2 module(s), DIN 43880 KEMA, VDE, UL, VdS Weight 242 g GTIN 4013364108417 PU 1 pc(s) 12

DEHNguard DG M TN 275 (952 200) Prewired complete unit consisting of a base part and plug-in protection modules High discharge capacity due to heavy-duty zinc oxide varistors / spark gaps High reliability due to "Thermo Dynamic Control" SPD monitoring device Modular surge arrester for use in single-phase TN systems. Basic circuit diagram DG M TN 275 Dimension drawing DG M TN 275 Type DG M TN 275 Part No. 952 200 type 2 / class II 230 V (50 / 60 Hz) Max. continuous operating a.c. voltage (U C ) 275 V (50 / 60 Hz) Nominal discharge current (8/20 µs) (I n ) 20 ka Max. discharge current (8/20 µs) (I max ) 40 ka Voltage protection level (U P ) 1.5 kv Voltage protection level at 5 ka (U P ) 1 kv Response time (t A ) 25 ns Max. mains-side overcurrent protection 125 A gg Short-circuit withstand capability for max. mains-side overcurrent protection (I SCCR ) 50 ka rms Temporary overvoltage (TOV) (U T ) Characteristic 335 V / 5 sec. withstand Temporary overvoltage (TOV) (U T ) Characteristic 440 V / 120 min. safe failure Operating temperature range (T U ) -40 C... +80 C Cross-sectional area (min.) 1.5 mm 2 solid / flexible Cross-sectional area (max.) Capacity 2 module(s), DIN 43880 KEMA, VDE, UL, VdS Weight 229 g GTIN 4013364108394 PU 1 pc(s) 13

DEHNguard DG M TT 275 (952 310) Prewired complete unit consisting of a base part and plug-in protection modules High discharge capacity due to heavy-duty zinc oxide varistors / spark gaps High reliability due to "Thermo Dynamic Control" SPD monitoring device Basic circuit diagram DG M TT 275 Dimension drawing DG M TT 275 Modular surge arrester for use in TT and TN-S systems ("3+1" circuit). Type DG M TT 275 Part No. 952 310 type 2 / class II 230 / 400 V (50 / 60 Hz) Max. continuous operating a.c. voltage [L-N] (U C ) 275 V (50 / 60 Hz) Max. continuous operating a.c. voltage [N-PE] (U C ) 255 V (50 / 60 Hz) Nominal discharge current (8/20 µs) (I n ) 20 ka Max. discharge current (8/20 µs) (I max ) 40 ka Lightning impulse current (10/350 µs) [N-PE] (I imp ) 12 ka Voltage protection level [L-N] (U P ) 1.5 kv Voltage protection level [L-N] at 5 ka (U P ) 1 kv Voltage protection level [N-PE] (U P ) 1.5 kv Follow current extinguishing capability [N-PE] (I fi ) 100 A rms Response time [L-N] (t A ) 25 ns Response time [N-PE] (t A ) 100 ns Max. mains-side overcurrent protection 125 A gg Short-circuit withstand capability for max. mains-side overcurrent protection (I SCCR ) 50 ka rms 335 V / 5 sec. withstand 440 V / 120 min. safe failure Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 1200 V / 200 ms withstand Operating temperature range (T U ) -40 C... +80 C Cross-sectional area (min.) 1.5 mm 2 solid / flexible Cross-sectional area (max.) Capacity 4 module(s), DIN 43880 KEMA, VDE, UL, VdS Weight 450 g GTIN 4013364108479 PU 1 pc(s) 14

DEHNguard DG M TNS 275 (952 400) Prewired complete unit consisting of a base part and plug-in protection modules High discharge capacity due to heavy-duty zinc oxide varistors / spark gaps High reliability due to "Thermo Dynamic Control" SPD monitoring device Modular surge arrester for use in TN-S systems. Basic circuit diagram DG M TNS 275 Dimension drawing DG M TNS 275 Type DG M TNS 275 Part No. 952 400 type 2 / class II 230 / 400 V (50 / 60 Hz) Max. continuous operating a.c. voltage (U C ) 275 V (50 / 60 Hz) Nominal discharge current (8/20 µs) (I n ) 20 ka Max. discharge current (8/20 µs) (I max ) 40 ka Voltage protection level (U P ) 1.5 kv Voltage protection level at 5 ka (U P ) 1 kv Response time (t A ) 25 ns Max. mains-side overcurrent protection 125 A gg Short-circuit withstand capability for max. mains-side overcurrent protection (I SCCR ) 50 ka rms Temporary overvoltage (TOV) (U T ) Characteristic 335 V / 5 sec. withstand Temporary overvoltage (TOV) (U T ) Characteristic 440 V / 120 min. safe failure Operating temperature range (T U ) -40 C... +80 C Cross-sectional area (min.) 1.5 mm 2 solid / flexible Cross-sectional area (max.) Capacity 4 module(s), DIN 43880 KEMA, VDE, UL, VdS Weight 443 g GTIN 4013364108455 PU 1 pc(s) 15

www.dehn-international.com/partners Surge Protection DEHN + SÖHNE Hans-Dehn-Str. 1 Tel. +49 9181 906-0 Lightning Protection GmbH + Co.KG. Postfach 1640 Fax +49 9181 906-1100 Safety Equipment 92306 Neumarkt info@dehn.de DEHN protects. Germany www.dehn-international.com www.dehn-international.com/partners Type designations of products mentioned in the white paper being at the same time registered trademarks are not especially marked. So if there is no marking of or this does not mean that the type designation is a free trade name. Neither it can be seen whether patents or utility models and other intellectual and industrial property rights are available. We reserve the right to introduce changes in performance, configuration and technology, dimensions, weights and materials in the course of technical progress. The figures are shown without obligation. Misprints, errors and modifications excepted. Reproduction in any form whatsoever is forbidden without our authorisation. activsense, BLITZDUCTOR, BLITZPLANER, DEHN, DEHN Logo, DEHN schützt, DEHNbloc, DEHNfix, DEHNgrip, DEHNguard, DEHNport, DEHNQUICK, DEHNrapid, DEHNshield, DEHNsnap, DEHNventil, HVI, LifeCheck, Red/Line are protected by German Trade Mark, by Community Trade Mark (EU) and/or in other countries.