CI-tronic Soft start motor controller

Similar documents
CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

Soft starters with internal by-pass

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

References 1 for asynchronous motors 1

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

SELECTION GUIDE. BULLETIN 156 Solid-State Contactors

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Type CP-S, CP-C & CP-A Switch mode

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

Solid-State Soft Starters

TeSys H. Protection. Motor controllers. Reliable. Motor starters. Contactors. Circuit breakers. Smart. Ultra-compact 22.5 mm motor starters

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

150 C 30 F B D 8L 152H C 30 F BD 43 8L

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Single Phase Soft Starters

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

Modular equipment. Presentation, standards. Standard contactors TeSys GC

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

Output of three-phase motors at 50 Hz and 400 V

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Capacitor Switching Contactors

Switching power supplies CP range, Linear power supplies CP-L range. Content

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

Power supply CP-D 24/4.2 Primary switch mode power supply

SIRIUS/SIKOSTART Soft Starters For Standard Applications

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

CP-T range Product group picture

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Primary switch mode power supplies Product group picture

Technical features table for miniature circuit-breakers SH 200 Series

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Contactors and Contactor Assemblies

To be automatically connected to the nearest North American Technical Sales Office:

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

celduc SILD r e l a i s celpac PATENTED! AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting.

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Semiconductor contactors, Solid-state relays

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

RN Thyristor Controllers

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

CP-E range Benefits and advantages

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

NS..S contactor relays - with spring terminals AC operated

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

User's Guide for type ACS55 AC Drives from 0.18 to 2.2 kw

Inverter MICROMASTER 410

Three-phase monitoring relays CM-PFE and CM-PFE.2

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Semiconductor contactors, Solid-state relays

SOLID STATE RELAY RATINGS

Altivar 28 drive Altivar 28 enclosed drive

Motor Controllers Soft Starting/Soft Stopping Types RSC-AAM60/RSO...

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Operating Manual NS20K

Three-phase monitoring relay

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Characteristics 5 TeSys k contactors and reversing contactors

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

CP-T range Benefits and advantages

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

3 - Protection components Circuit-breakers

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

Motor Controllers 3-Phase Analog Power Controller Types RSC-AAM60/RSO...

Electronic timer CT-SDS.22

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

Transcription:

Data sheet CI-tronic Soft start motor controller MCI 3, MCI 15, MCI, MCI 30 I-O, MCI 40-3D I-O and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus reducing the inrush current and eliminating the damaging effects of high starting torque surges. The digitally controlled soft starter features accurate settings and easy installation. The controller has individually adjustable acceleration and deceleration times. Thanks to the adjustable initial torque and the unique breakaway (kick start) function the soft starter can be optimized for almost any application. The MCI soft starters are typically used on motor applications where a smooth start and/or stop is advantageous, such as conveyors, fans, pumps, compressors and high inertia loads. MCI soft starters are also obvious as replacement for star/delta starters. Features Motor load max. 50 A Acceleration times adjustable: 0 10 seconds, MCI 3, MCI 15 and MCI 0 20 seconds, MCI 30 I-O 0 30 seconds, MCI 40-3D I-O, MCI 50-3 I-O Deceleration times adjustable: 0 10 seconds, MCI 3, MCI 15, and MCI 0 20 seconds, MCI 30 I-O 0 60 seconds, MCI 40-3D I-O, MCI 50-3 I-O Initial torque adjustable up to 85% Breakaway function (kick start) Universal control voltage: 24 480 V AC / DC Automatic detection of missing phases Automatic adaptation to 50/60 Hz Optional auxiliary contacts LED Status indication Unlimited start/stop operations per hour Built in varistor protection Compact modular design DIN rail mountable EN 60947-4-2 CE and CULUS (UL 508) EAC and LLC approved IC.PD.C50.A6.02 1

Adjustments Motor torque (voltage) Ramp-up time Ramp-down time Kick start selectable Adjustable starting torque Time Selection guide Type Operational voltage Motor current max. Motor power max. Module dimensions Aux. contacts Code no. [V AC] [A] [kw / HP] [mm] MCI 15 208 240 15 4.0 / 5.5 45 037N0037 MCI 208 240 7.5 / 10 90 037N0038 MCI 208 240 (30) 1) 11 / 15 1) 90 I O, bypass 037N0069 MCI 50 3 I O 208 240 35 (50) 1) 15 / 20 1) 180 I O, bypass 037N0089 MCI 3 380 415 3 1.5 / 2 22.5 037N0074 MCI 3 440 480 3 1.5 / 2 22.5 037N0084 MCI 15 380 480 15 7.5 / 10 45 037N0039 MCI 380 480 11 / 15 90 037N0040 MCI 30 I O 380 480 (30) 1) 15 / 20 1) 90 I O, bypass 037N0070 MCI 40 3D I O 380 480 29 (43) 1) 21 / 28 1) 90 I O, bypass 037N0092 MCI 50 3 I O 380 480 35 (50) 1) 22 / 30 1) 180 I O, bypass 037N0090 MCI 15 500 600 15 7.5 / 10 45 037N0041 MCI 500 600 15 / 20 90 037N0042 1) If used with bypass contactor IC.PD.C50.A6.02 2

Technical data Output Specification MCI 3 MCI 15 MCI MCI 30 I-O MCI 40-3D I-O MCI 50-3 I-O Operational current max. 3 A 15 A A 30 A (if bypassed during steady state) 43 A (if bypassed during steady state) 50 A (if bypassed during steady state) Motor size at: 208 240 V AC 0.1 0.7 kw (0.18 1 HP) 0.1 4.0 kw (0.18 5.5 HP) 0.1 7.5 kw (0.18 10 HP) 0.1 11 kw (0.18 15 HP) 0.1 15 kw (0.18 20 HP) 380 480 V AC 0.1 1.5 kw (0.18 2 HP) 0.1 7.5 kw (0.18 10 HP) 0.1 11 kw (0.18 15 HP) 0.1 15 kw (0.18 20 HP) 0.1 21 kw (0.18 28 HP) 0.1 22 kw (0.18 30 HP) 500 600 V AC 0.1 2.2 kw (0.18 3 HP) 0.1 7.5 kw (0.18 10 HP) 0.1 15 kw (0.18 20 HP) 0.1 18.5 kw (0.18 HP) 0.1 30 kw (0.18 40 HP) Leakage current max 5 ma Min. operational current 50 ma Overload relay trip class Class 10 Semiconductor protection Type 1 co-ordination Type 2 co-ordination I 2 t (t = 10ms) A gl/gg 72 A2s 50 A gl/gg 1800 A2s 80 A gl/gg 6300 A2 s 80 A gl/gg 6300 A2 s 80 A gl/gg 6300 A2 s 1 A gl/gg Rating index: AC-53a Asynchronous motors AC-53b Asynchronous motors with bypass AC-58a Hermetic refrigeration compressors 15A: AC-53a: 8-3: 100-3000 A: AC-53a: 6-5: 100-480 A: AC-53a: 6-5: 100-480 29A: AC-53a: 6-5: 100-120 35A: AC-53a: 6-6: 100-120 3A: AC-53b: 5-5: 10 30A: AC-53b: 5-5: 30 43A: AC-53b: 5-5: 30 50A: AC-53b: 6-6: 30 15A: AC-58a: 6-6: 100-3000 A: AC-58a: 6-6: 100-480 A: AC-58a: 6-6: 100-480 Control Circuit Specifications Control voltage range 24 480 V AC / DC Pick-Up voltage max. 20.4 V AC / DC Drop-out voltage min. 5 V AC / DC Max. control current for no operation 1 ma Control current / Power max. 15 ma / 2 VA Response time max. 70 ms Ramp-up time adjust. from 0 10 seconds 0 20 seconds 0 30 seconds Ramp-down time adjust. from 0 10 seconds 0 20 seconds 0 60 seconds Initial Torque adjust. from 0 85% of nominal torque with optional kick start SCR Aux. contacts, opt. voltage/current max. 24 480 V AC / 0.5 A 24 480 V AC / 1.0 A (AC-14, AC-15) Fuse max. I 2 t (t = 10ms) 10 A gl/gg, I 2 t max. 72 A 2 s EMC immunity and emission Meets requirements of EN 60947-4-2 Insulation Rated installation voltage, Ui Rated impulse withstand voltage, Uimp V Installation Category 660 V AC 4 k III Thermal specifications MCI 3 MCI 15 MCI MCI 30 I-O MCI 40-3D I-O MCI 50-3 I-O Power dissipation 1), continuous duty max.: 4 W 2 W/A 2 W/A 2 W/A 3 W/A 3 W/A Power dissipation 1), Intermittent duty max.: 4 W 2 W/A x duty cycle 2 W/A x duty cycle 2 W/A x duty cycle 3 W/A x duty cycle 3 W/A x duty cycle Ambient temperature range -5 C 40 C Cooling method Natural convection Mounting Vertical +/- 30 Max. ambient temperature with limited rating 60 C, see derating for high temperatures in chart page 7 Storage temp. range -20 C 80 C Protection degree / pollution degree IP20 / IP3 IP10 / IP3 Materials Housing Self extinguishing PPO UL94V1 Heatsink Aluminum black anodized Base Electroplated steel 1) If used without a bypass contactor IC.PD.C50.A6.02 3

Functional diagram Mains voltage L1, L2, L3 Control voltage (A1, A2) Motor voltage (T1, T2, T3) LED 1 LED 2 Aux. contacts: 23 24 bypass 13 14 I-O Example 1: Example 2: Soft start and soft stop Soft start with kick start and soft stop Functional description Ramp up During ramp-up the controller will gradually increase the voltage to the motor until it reaches full line voltage. The motor speed will depend on the actual load on the motor shaft. A motor with little or no load will reach full speed before the voltage has reached its maximum value. The actual ramp time is digitally calculated and will not be influenced by other settings, net frequency or load variations. Initial torque The initial torque is used to set the initial starting voltage. This way it is possible to adapt the controller to an application requiring a higher starting torque. In some cases on application with very high break-away torque the initial torque can be combined with a kick start function. The kick start is a period of 200 ms where the motor receives full voltage. Soft stop During ramp-down the controller will gradually reduce the voltage to the motor thus reducing the torque and current. As a consequence the motor speed will fade off. The soft stop feature is advantageous to avoid liquid hammering and cavitation on pumps, and to avoid goods tilting on conveyors. Auxiliary contacts, optional The auxiliary contacts are made possible by means of SCR technology and will only switch correctly on AC current. I-0 contact (13 14): The contact will be closed as long as the controller receives a control voltage, see functional diagram. Bypass contact (23 24): The contact is intended for operating an external bypass contactor. The contact will close when the controller is in steady state operation, see functional diagram. LED status indication LED status indication: LED 1 LED 2 Stand Ramp- Full Ramp- Line or by up on down load error IC.PD.C50.A6.02 4

Wiring MCI 15, MCI MCI 30 I-O MCI 50-3 Overload and Short Circuit Protection Overload and short circuit protection is easily achieved by installing a circuit breaker on the line side of the soft starter. Select the circuit breaker from the table according to motor full load current. Be aware of the maximum prospective short circuit current breaking capacity. For further information please refer to the data sheet on the circuit breaker. 380 415 V AC Circuit breaker Type Motor full load current Max. prospective short-circuit current I cc for co-ordination 2 Soft starter Soft starter I 2 t value Type [A] [A 2 s] [ka] Circuit breaker Code no. CTI M 0.40 0.63 MCI 15 1800 100 047B3143 CTI M 0.63 1.0 MCI 15 1800 100 047B3144 CTI M 1.0 1.6 MCI 15 1800 100 047B3145 CTI M 1.6 2.5 MCI 15 1800 100 047B3146 CTI M 2.5 4.0 MCI 15 1800 100 047B3147 CTI M 4 6.3 MCI 15 1800 4 047B3148 CTI M 6.3 10 MCI 15 1800 1.5 047B3149 CTI M 10 16 MCI 15 1800 2.5 1) 047B3150 CTI M 14.5 20 MCI /30 I-O 6300 1.8 047B3151 CTI M 18 MCI /30 I-O 6300 1.5 047B3152 CTI 45MB 23 32 MCI 50 I-O 300 6 047B3164 CTI 45MB 32 45 MCI 50 I-O 300 4 047B3165 1) Type 2 co-ordination can only be achieved with MCI IC.PD.C50.A6.02 5

Operation at high temperatures If soft starter is used without external bypass contactor: Ambient temperature Continuous current MCI 3 MCI 15 MCI MCI 30 I-O MCI 40-3D I-O MCI 50-3 I-O [A] [A] [A] [A] [A] [A] 40 C 3 15 29 35 50 C 2.5 1) 12. 5 20 20 23 30 60 C 2.0 1) 10 17 17 20 1) Minimum 10 mm side clearance between products Ambient temperature 40 C 50 C 60 C Duty-cycle rating (15 min. max. on-time) MCI 15 MCI MCI 30 I-O MCI 40-3D I-O MCI 50-3 I-O [A] [A] [A] [A] [A] 15 (100% duty cycle) 15 (80% duty cycle) 15 (65% duty-cycle) (100% duty cycle) (80% duty cycle) (65% duty-cycle) (100% duty cycle) (80% duty cycle) (65% duty-cycle) 43 (65% duty cycle) 43 (50% duty cycle) 43 (40% duty-cycle) 50 (65% duty cycle) 50 (55% duty cycle) 50 (45% duty-cycle) If soft starter is used with external bypass contactor Ambient temperature Continuous current MCI MCI MCI 30 I-O MCI 40-3D I-O MCI 50-3 I-O [A] [A] [A] [A] [A] 40 C 15 30 43 50 50 C 15 30 43 50 60 C 15 30 43 50 Over heat protection If required the controller can be protected against overheating by inserting a thermostat in the slot on the right-hand side of the controller. Order: UP 62 thermostat 037N0050 Depending on the application the thermostat can be connected in series with the control circuit of the main contactor. When the temperature of the heat sink exceeds 90 C the main contactor will be switched OFF. A manual reset is necessary to restart this circuit. For wiring connections see application examples page 8. Not with MCI 3 Mounting Instructions The controller is designed for vertical mounting. If the controller is mounted horizontally the load current must be reduced by 50%. The controller needs no side clearance. Clearance between two vertical mounted controller must be minimum 80 mm (3.15 ). Clearance between controller and top and bottom walls must be minimum 30 mm (1.2 ). IC.PD.C50.A6.02 6

Application examples Overheat protection Example 1 The thermostat can be connected in series with the control input of the soft starter. When the temperature of the heat sink exceeds 90 C the soft starter will be switched OFF. NOTE: when the temperature has dropped approx. 30 C the controller will automatically be switched ON again. This is not acceptable in some applications. Example 2 The thermostat is connected in series with the control circuit of the main contactor When the temp. of the heat sink exceeds 90 C the main contactor will be switched OFF. This circuit requires manual reset to restart the motor. Line Controlled Soft start When the contactor C1 is switched to the ON-State, the soft starter will start the motor, according to the settings of the Ramp-up time and Initial torque adjustments. When the contactor C1 is switched to the OFF-State the motor will be switched off instantaneously. In this application the contactor will have no load during making operation. The contactor will carry and break the nominal motor current. IC.PD.C50.A6.02 7

Application examples (Cont.) Input controlled soft start When the control voltage is applied to A1 A2, the MCI soft starter will start the motor, according to the settings of the Ramp-up time and Initial torque adjustments. When the control voltage is switched OFF, the motor will be soft stopped according to the settings of the Ramp-down time adjustment. To switch off instantaneously set the Ramp-down time to 0. Combined reversing contactor and soft starter Soft Start & Soft Stop A soft reversing of a motor can easily be achieved by connecting a reversing contactor to the soft starter. The reversing contactor, type RCI, will determine the direction of rotation, forward or reverse and the soft starter, type MCI, will perform soft-starting and softstopping of the motor. Soft Start only If soft-stop is not required the application can be simplified by connecting the control circuit, of the soft starter, to the main terminals as shown under Line controlled Soft-Start (see example on page 8). A delay of approx. 0.5 sec. between forward and reverse control signal must be allowed to avoid infl uence from the voltage generated by the motor during turn-off. Instead of the electronic reversing contactor, type RCI, an electromechanical reversing contactor can be applied. Due to the soft starter the reversing contactor will not be exposed to high inrush currents. As a result a longer life time of the electromechanical contactor can be expected. IC.PD.C50.A6.02 8

Application examples (Cont.) MCI with bypass contactor If the MCI soft starter is bypassed during steady state operation there is no heat dissipation. A bypassed MCI can be loaded according to tabel page 7: Operating at high temperatures. By means of the integrated auxiliary contact the bypass function is easily achieved. See wiring diagram below and Functional diagram page 5. As the contactor always switches in after end of ramp up time it can be selected on the basis of the thermal current (AC-1). MCI 30 I-O MCI 40-3D I-O Inside - delta motor configuration Bypass contactor IC.PD.C50.A6.02 9

Dimensions mm (inch) MCI 3 MCI 15 MCI, MCI 30 I-O MCI 40-3D I-O MCI 50-3 I-O IC.PD.C50.A6.02 10