Reinforcing Mesh Product Guide

Similar documents
Reinforcing Mesh Product Guide

Introduction of British Standard BS 8666:2005

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

THE WORLD LEADER. Reinforcing Bar Coupler System. For The Construction Industry.

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

JIS G3465 Seamless Steel Tubes for Drilling

Oil tempered SiCrV-alloyed high tensile valve spring wire Only manudactured in China

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND

TECH FACTS METRIC WELDED WIRE REINFORCEMENT FOR CONCRETE PIPE. Principles of Reinforcement

Premium-6 Hexagonal Wire Netting for general and rural applications

PD 3 Dowel Cradle. Load Transfer System Industrial Slab on Ground

Securifor Polyester Coated Welded Mesh Panels

AS Australian Standard STEEL WIRE FOR TENDONS IN PRESTRESSED CONCRETE. This is a free 5 page sample. Access the full version online.

TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

ARMTEC.COM. Built to last. Custom Precast Solutions For Your Home. Custom Steps Custom Decks Window Wells Stairwells Brackets

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

BUILDING STRENGTH REBAR SPLICING HANDBOOK CONCRETE CONSTRUCTION PRODUCTS

East African Roofing Systems Ltd.

Steeline X-SPAN purlins

CONCRETE ACCESSORIES BAR-LOCK REBAR COUPLER SYSTEM

Scheduling, dimensioning, bending and cutting of steel reinforcement for concrete Specification

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2

Diamond Dowel. Load Transfer System INDUSTRIAL SLAB ON GROUND

MESP TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/ mm 2

Erstantie 2, FIN Villähde Tel , Fax

FRANK. Technologies for the construction industry. Egcodubel Shear force dowel for low and middle loads

ARMTEC.COM. Built to last. Custom Precast Solutions For Your Home. Custom Steps Custom Decks Standard Steps Window Wells Brackets Stairwells

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

P r o d u c t D e s c r i p t i o n

When you need a clearspan of up to 6 metres of longrun steel you need...

Proposed changes on NZS 3404 specified part-turn method of tensioning high strength friction grip (HSFG) property class 8.8 bolts

(1) Brass, an alloy of copper and zinc, consists of 70% by volume of copper and 30% by volume of zinc.

Table 3 - Standard shapes, their method of measurement and calculation of length Method of. Total length of bar (L) of bending dimensions

Hyper ArmourMate. Joint Edge Protection INDUSTRIAL SLAB ON GROUND

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

Bolt Material Types and Grades 1- Bolts made of carbon steel and alloy steel: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 10.9 Nuts made of carbon steel and alloy

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

Convex Strainers DN PN 80, 100, 200

Index Terms: Lathe waste concrete; Shear and bending; Shear strength; Stirrups; Simply supported beams.

Section 914. JOINT AND WATERPROOFING MATERIALS

isd dunaferr Product catalogue

Double Bar Plate Dowels for Saw-Cut Contraction Joints

ERECTION & CONSTRUCTION

TECHNICAL SPECIFICATION FOR G.I. WIRE AND G.I. STAY WIRE

STRUCTURAL BRACKETS CATALOGUE

DRAFT UGANDA STANDARD

FORTRESS BOTTOM PLATE ANCHORS. Product. Scope. Building Regulations. Appraisal No. 687 [2017]

SHED PACK Step 1: Choose your shed type.

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg

CHAPTER 10 MICHIGAN DESIGN MANUAL BRIDGE DESIGN (SI) SHOP DRAWING REVIEW TYPES OF SHOP DRAWINGS Structural Steel

2.3 SPECIFIC DESIGN DHS PURLINS

Shear force transmission in expansion joints

WHY YOU SHOULD USE TUFFLOOR. components

Renold Roller Chain. The consistent performance of Renold roller chain is ensured by a programme of continuous testing and quality audits.

How-To-build guide carport

1 SLABBING, RENDERING, FLOATING AND SKIMMING

CARES Technical Approval Report TA1-B 5042

TECHNICAL INSTRUCTIONS: FOUNDRY. Page 1 of 8

TECHNICAL MANUAL. HPM Rebar Anchor Bolt Easy and Fast Bolted Connections

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

REBAR SPLICING HANDBOOK PERFORM WITH PRECISION CONCRETE CONSTRUCTION PRODUCTS

Oil tempered SiCrV-alloyed high tensile valve spring wire

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

Requirements for manufacture of anchors

STEEL PIPE GUIDERAIL 01/01/

ALUMINUM PIPE GUIDERAIL 01/01/

ISO INTERNATIONAL STANDARD. Welding Studs and ceramic ferrules for arc stud welding

STRUCTURAL BRACKETS CATALOGUE

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

Suitable for panels up to 12 tonne. No sharp edges. Lighter than comparable capacity systems. So, why the need for change?

TOPSPAN 22 / 40 LYSAGHT TOPSPAN 22 / 40. Steel roof and ceiling battens for non cyclonic applications

Contents DIN 50125:

² TL Beton-StB 07 = German technical conditions for construction materials for concrete road pavements

PEC-TA Cast-in Channels and Bolts. Certified German quality for high-end fixing solutions. Advantages of using PEC Cast-in Channels.

A. Extent of structural precast concrete work is shown on drawings and in schedules.

EXPERIMENTAL AND ANALYTICAL STUDIES ON THE STRENGTHENING OF RC FRAMES

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

FURTHER STATIC TENSION TESTS OF BOLTED JOINTS. A B S T RAe T

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

ISO 783 INTERNATIONAL STANDARD. Metallic materials Tensile testing at elevated temperature

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

SSAB Laser OPTIMIZED FOR YOU AND LASER CUTTING

INTERGOVERNMENTAL STANDARD GOST Plywood with faces in hardwood veneer for general use.

Connectors for Cold-Formed Steel Curtain-Wall Construction

FRANK. Technologies for the construction industry. Egcodorn Shear force dowel for expansion joints

Foundation Specifications

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

Extract 8.7 When dimensioning an acute angle the tangential lines shown in Figure 4 shall be used. (C) Figure 4 - Dimensioning of an acute angle

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

Foundation Specifications

Cooke Precast Concrete

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

Welded connections Welded connections are basically the same design in AISI as in AISC. Minor differences are present and outlined below.

HILAND TRAY FORM AND FUNCTION MATERIAL SPECIFICATIONS DESIGN GUIDE ROOFING I WALLING

Standard Specification for High-Strength Steel Bolts, Classes 10.9 and , for Structural Steel Joints [Metric] 1

For a free video, CD, samples and your nearest EUROBEND representative, please, contact: ADVANCED TECHNOLOGY PRODUCTS

PROJECT INSTRUCTIONS Roofing

Transcription:

Reinforcing Mesh Product Guide Reinforcing New Zealand since 1954 Super Ductile 500E & Hard Drawn NORTH ISLAND

Fletcher Reinforcing supplies the reinforcing steel and mesh that provides the strength to New Zealand s buildings and infrastructure. Mesh is available from national Building Merchants or our branch network to construction sites and builders throughout New Zealand. Fletcher Reinforcing offer a range of New Zealand manufactured mesh. The range covers both Super Ductile mesh in grade 500E wire and a proven range of hard drawn mesh in the sizes required by builders and contractors throughout New Zealand. The Department of Building & Housing now states the reinforcing requirements for concrete slabs-on-ground of buildings built in accordance with NZS 3604: 2011, have a minimum of 2.27 kg/m2 of Grade 500E reinforcing mesh fabric which conforms with AS/NZS4671:2001. Super Ductile 500E meets these requirements: Grade 500E (seismic) as per AS/NZS 4671:2001 ield stress (MPa) >500 <600 Elongation >10% Tensile Ratio % >1.15 <1.40 Weight per m2 complies with NZS 3604:2011 (min 2.27kg/m2) Hard drawn mesh: Fletcher Reinforcing offers a range of mesh sheet sizes and centres to meet the needs of typical New Zealand applications. Our range covers standard sheet sizes of 4.65m x 1.97m through to our larger economical sheets which are 6.15m x 2.42m. Centres are either 150 x150mm or the step through option of 300 x 300mm.

New Zealand Standards Standards New Zealand controls the preparation and publishing of all Standard Specifications and Codes of Practice in New Zealand. They are developed by expert committees using a consensus-based process that facilitates public input. The relevant Standards listed below, specify the mechanical properties of the steel wire used for concrete reinforcement, the fabrication of the welded fabric and the methods of application in respect to concrete reinforcement. Visit www.standards.co.nz for more information. AS/NZS4671:2001 Specification for Welded Fabric of Drawn Steel Wire for Concrete Reinforcement The pitch (a) of longitudinal bars and transverse bars shall not be less than 50 mm. The pitch shall be measured as shown below. The tolerance of the pitch shall not be more than +/-0.075 times the specified value. NZS3101:2006 Code of Practice for The Design of Concrete Structures This Standard lays out the development length and lap-splice requirements for plain wire mesh and deformed wire mesh, and is the basis of any pertinent calculations or recommendations given in this Product Guide.

Standard Equivalent Centres Wire Ø Width Nett Cover (m 2 ) Fletcher Reinforcing Item 668 150 4.0 4560 1980 7.525 668L 665 150 5.3 4560 1980 7.525 665L 663 150 6.3 4560 1980 7.525 663L 661 150 7.5 4560 1980 7.525 661L Hard Drawn Mesh Equivalents 300 Centres Equivalent Centres Wire Ø Width Nett Cover (m 2 ) Fletcher Reinforcing Item 668 300 5.6 5000 2240 11.20 84/10 665 300 7.5 5000 2240 11.20 147/10 Equivalents are based on the nominal sectional area of steel per metre width *Note: Additional meshes are available as a special order. Minimum order quantities will apply. Please contact your local Fletcher Reinforcing Branch for further details Super Ductile 500E Mesh Equivalents Equivalent Centres Wire Ø Width Nett Cover (m 2 ) Fletcher Reinforcing Item 665 200 6.1 5050 2020 8.312 SE62Res 665 200 6.1 5850 2420 11.93 SE62 665 300 7.5 5000 2270 10.08 SE73DE 664 200 7.0 5650 2220 10.432 SE72 662 200 8.0 5650 2220 10.432 SE82 661 150 8.0 5650 2220 10.165 SE815 What does SE62 mean? AS/NZS 4671:2001 designates letters to be used to identify welded mesh products: S = Square (shape of grid centres) E = Seismic grade (Earthquake) 6 = 6mm wire 2 = 200mm centres Equivalents are based on the nominal sectional area of steel per metre width

Description Hard drawn wire mesh 485 Mpa Wire Diameter Centres Cross Section (mm 2 /m) Mass per m 2 (kg/m 2 ) Industry Equivalents 668L 4.0 150 83.8 1.315 668 84/10 5.6 300 82.1 1.289 668 Description Super Ductile wire mesh Min: 500 MPa Max: 600MPa Wire Diameter Centres (m 2 ) Cross Section (mm 2 /m) Mass per m 2 (kg/m 2 ) 665L 5.3 150 147.1 2.309 665 SE62Res 6.1 200 146.1 2.294 665 SE62 6.1 200 146.1 2.294 147/10 7.5 300 147.3 2.312 665 665 SE73DE 7.5 300 147.3 2.312 664 SE72 7.0 200 192.4 3.02 663L 6.3 150 207.8 3.263 663 662 SE82 8.0 200 251.3 3.946 661 SE815 8.0 150 335.1 5.261 Equivalents are based on the nominal sectional area of steel per metre width *Note: Additional meshes are available as a special order. Minimum order quantities will apply. Please contact your local Fletcher Reinforcing Branch for further details

Seismic Grade Reinforcing Mesh Product Description: 5.05m x 2.02m 200 x 200 Grid R6.1 Line Wire, R6.1 Cross Wire SE62 Res NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 6.1 R 200 5050 11 25 25 146.1 0.2294 12.74 Cross Wire 6.1 R 200 2020 26 10 10 146.1 0.2294 12.05 GROSS SHEET WEIGHT (Kg): 24.79 MASS PER SQ METER (Kg/m 2 ): 2.294 GROSS SHEET AREA (m 2 ) 10.201 NETT COVER (m 2 ) 8.312 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 0.0933 BUNDLE WEIGHT (Tonnes): 0.6198 ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 7.3 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001.

Seismic Grade Reinforcing Mesh Product Description: 5.85m x 2.42m 200 x 200 Grid R6.1 Line Wire, R6.1 Cross Wire SE62 NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 6.1 R 200 5850 13 25 25 146.1 0.2294 17.45 Cross Wire 6.1 R 200 2420 30 10 10 146.1 0.2294 16.65 GROSS SHEET WEIGHT (Kg): 34.10 MASS PER SQ METER (Kg/m 2 ): 2.294 GROSS SHEET AREA (m 2 ) 14.157 NETT COVER (m 2 ) 11.932 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 2.2453 BUNDLE WEIGHT (Tonnes): 0.8525 ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 > 7.3 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001.

Seismic Grade Reinforcing Mesh Product Description: 5.65m x 2.22m 200 x 200 Grid R7.0 Line Wire, R7.0 Cross Wire SE72 NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 7.0 R 200 5650 12 25 25 192.4 0.3021 20.48 Cross Wire 7.0 R 200 2220 29 10 10 192.4 0.3021 19.45 GROSS SHEET WEIGHT (Kg): 39.93 MASS PER SQ METER (Kg/m 2 ): 3.021 GROSS SHEET AREA (m 2 ) 12.543 NETT COVER (m 2 ) 10.432 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 2.2828 BUNDLE WEIGHT (Tonnes): 0.9983 ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 > 9.6 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001.

Seismic Grade Reinforcing Mesh Product Description: 5.0m x 2.27m 300 x 300 Grid R7.5 Line Wire, R7.5 Cross Wire SE73DE NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 1 7.5 R 300 5000 8 25 25 147.3 0.3468 13.87 Longitudinal Wire 2 5.5 R 75 5000 2 25 25 0.1865 1.87 Cross Wire 7.5 R 300 2270 19 10 10 147.3 0.3468 14.96 GROSS SHEET WEIGHT (Kg): 30.69 MASS PER SQ METER (Kg/m 2 ): 2.312 GROSS SHEET AREA (m 2 ) 11.35 NETT COVER (m 2 ) 10.08 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 20 ESTIMATED CUBIC (m 3 ) 0.1277 BUNDLE WEIGHT (Tonnes): 0.6139 ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 > 9.6 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001.

Seismic Grade Reinforcing Mesh Product Description: 5.65m x 2.22m 200 x 200 Grid R8.0 Line Wire, R8.0 Cross Wire SE82 NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 8.0 R 200 5650 12 25 25 251.3 0.3946 26.75 Cross Wire 8.0 R 200 2220 29 10 10 251.3 0.3946 25.40 GROSS SHEET WEIGHT (Kg): 52.16 MASS PER SQ METER (Kg/m 2 ): 3.946 GROSS SHEET AREA (m 2 ) 12.543 NETT COVER (m 2 ) 10.432 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 2.6089 BUNDLE WEIGHT (Tonnes): 1.3040 ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 > 12.5 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001.

Seismic Grade Reinforcing Mesh Product Description: 5.65m x 2.22m 150 x 150 Grid R8.0 Line Wire, R8.0 Cross Wire SE815 NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 8.0 R 150 5650 15 50 50 335.1 0.3946 33.44 Cross Wire 8.0 R 150 2220 38 60 60 335.1 0.3946 33.29 GROSS SHEET WEIGHT (Kg): 66.73 MASS PER SQ METER (Kg/m 2 ): 5.261 GROSS SHEET AREA (m 2 ) 12.543 NETT COVER (m 2 ) 10.165 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 2.6089 BUNDLE WEIGHT (Tonnes): 1.6683 ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 > 12.5 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001.

Hard Drawn Reinforcing Mesh Product Description: 4.56m x 1.98m 150 x 150 Grid R4.0 Line Wire, R4.0 Cross Wire 668L NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 4.0 R 150 4560 14 30 30 83.8 0.0986 6.29 Cross Wire 4.0 R 150 1980 31 15 15 83.8 0.0986 6.05 GROSS SHEET WEIGHT (Kg): 12.34 MASS PER SQ METER (Kg/m 2 ): 1.315 GROSS SHEET AREA (m 2 ) 9.029 NETT COVER (m 2 ) 7.525 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) BUNDLE 0.90 BUNDLE WEIGHT (KG): 309 Wire Diam 0.2% Proof Stress Ratio Min Max Rm / Re 4.0mm 1.5% 485MPa 750MPa 1.03% 4.0mm 1.5% 485MPa 750MPa 1.03%

Hard Drawn Reinforcing Mesh Product Description: 4.56m x 1.98m 150 x 150 Grid R5.3 Line Wire, R5.3 Cross Wire 665L NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 5.3 R 150 4560 14 30 30 147.1 0.1732 11.06 Cross Wire 5.3 R 150 1980 31 15 15 147.1 0.1732 10.63 GROSS SHEET WEIGHT (Kg): 21.69 MASS PER SQ METER (Kg/m 2 ): 2.309 GROSS SHEET AREA (m 2 ) 9.029 NETT COVER (m 2 ) 7.525 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 25 ESTIMATED CUBIC (m 3 ) BUNDLE 1.26 BUNDLE WEIGHT (KG): 542 Wire Diam 0.2% Proof Stress Ratio Min Max Rm / Re 5.3mm R 1.5% 485MPa 750MPa 1.03% 5.3mm R 1.5% 485MPa 750MPa 1.03%

Hard Drawn Reinforcing Mesh Product Description: 4.56m x 1.98m 150 x 150 Grid R6.3 Line Wire, R6.3 Cross Wire 663L NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 6.3 R 150 4560 14 30 30 207.8 0.2447 15.62 Cross Wire 6.3 R 150 1980 31 15 15 207.8 0.2447 15.10 GROSS SHEET WEIGHT (Kg): 30.72 MASS PER SQ METER (Kg/m 2 ): 3.263 GROSS SHEET AREA (m 2 ) 9.029 NETT COVER (m 2 ) 7.525 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) BUNDLE 1.94 BUNDLE WEIGHT (Kg): 766 Wire Diam 0.2% Proof Stress Ratio Min Max Rm / Re 6.3mm 1.5% 485MPa 750MPa 1.03% 6.3mm 1.5% 485MPa 750MPa 1.03%

Hard Drawn Reinforcing Mesh Product Description: 5.0m x 2.24m 300 x 300 Grid D5.6 Line Wire, D5.6 Cross Wire 84/10 NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 1 5.6 R 300 5000 6 50 50 82.1 0.1933 5.80 Longitudinal Wire 2 4.0 R 50 5000 4 50 50 0.0986 1.97 Cross Wire 5.6 R 300 2240 19 20 20 82.1 0.1933 8.23 GROSS SHEET WEIGHT (Kg): 16.00 MASS PER SQ METER (Kg/m 2 ): 1.289 GROSS SHEET AREA (m 2 ) 11.2 NETT COVER (m 2 ) 10.08 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 25 ESTIMATED CUBIC (m 3 ) BUNDLE 1.45 BUNDLE WEIGHT (KG): 400 Wire Diam 0.2% Proof Stress Ratio Min Max Rm / Re 5.6 D 1.5% 485MPa 1.03% 5.6 D 1.5% 485MPa 750MPa 1.03%

Hard Drawn Reinforcing Mesh Product Description: 5.0m x 2.24m 300 x 300 Grid D7.5 Line Wire, D7.5 Cross Wire 147/10 NI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 1 7.50 D 300 5000 6 50 50 147.3 0.3468 10.40 Longitudinal Wire 2 5.30 D 50 5000 4 50 50 0.1737 3.46 Cross Wire 7.50 D 300 2240 19 20 20 147.3 0.3468 14.76 GROSS SHEET WEIGHT (Kg): 28.63 MASS PER SQ METER (Kg/m 2 ): 2.312 GROSS SHEET AREA (m 2 ) 11.20 NETT COVER (m 2 ) 10.08 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 25 ESTIMATED CUBIC (m 3 ) BUNDLE 2.4 BUNDLE WEIGHT (KG): 715 Wire Diam 0.2% Proof Stress Ratio Min Max Rm / Re 7.50 D 1.5% 485MPa 750MPa 1.03% 7.50 D 1.5% 485MPa 750MPa 1.03%

Overview The Fletcher Reinforcing Smart Phone App is designed to offer you immediate access to the information you need about our ranges of Super Ductile and Hard Drawn meshes. This Guide will outline how to access this information quickly and easily. Downloading Available for both the Apple iphone and all Android phones, the free download can be accessed through the Apple App Store and the Android Market. Just search for Fletcher Reinforcing Alternatively, scan this QR Code from your phone to be taken to the appropriate download: V06.00.0318