SOMEDAY ALL UNDERLAYMENT WILL BE LIKE RAPTOR

Similar documents
Asphalt Shingle Installation at Roof Edges, Intersections and Valleys

StormMaster Slate General Instructions 1.) GENERAL INSTRUCTIONS 2.) ROOF DECK VENTILATION 3.) ROOF DECK

eco-shake INSTALLATION INSTRUCTION

Hatteras Shingles. CertainTeed Shingle Applicator s Manual. YOUR OBJECTIVE: To learn the correct procedures for installing Hatteras shingles

Cambridge English Application Instructions

HERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD

C e r t a i n T e e d S h i n g l e A p p l i c a t o r s M a n u a l. and Carriage House STEEP. Slope Application. (over 21/12)

Tuff-Rib Install Guide

Timberline and Sovereign Expanded Fastener Placement Area

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

Laminated Shingles. Landmark Series and Landmark TL. CertainTeed Shingle Applicator s Manual

Grand Manor Carriage House and Centennial Slate 16 YOUR OBJECTIVE: To learn the correct method of installing each of these roofing products.

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

PREMIUM LAMINATED ASPHALT SHINGLES Frederick, MD

GlassMaster General Instructions - Ardmore, OK & Hampton, GA <br /> Atlas Roofing

STORMMASTER SHAKE GENERAL INSTRUCTIONS

StormMaster Shake GENERAL INSTRUCTIONS For Spanish Instructions Click Here (Para las Instrucciones Españolas Haga Clic Aquí)

A P P L I C A T I O N I N S T R U C T I O N S

LAMINATED SHINGLES CERTAINTEED SHINGLE APPLICATOR S MANUAL SUPPLEMENT

ZIP System Roof Sheathing INSTALLATION MANUAL A REVOLUTION IN ROOFING

F-WAVE REVIA SYNTHETIC ROOFING SHINGLES

Roofing Training - Basics. Sandy Wesch

BARRELL VAULT BATTENLESS

Webinar Questions & Answers: Investigating Wind & Hail Damage

B. Related Sections: The following Sections contain requirements that relate to this Section:

DIRECTIONS FOR APPLICATION

DIRECTIONS FOR APPLICATION

Three -Tab Shingles. CertainTeed Shingle Applicator s Manual

DIRECTIONS FOR APPLICATION

Tamko. tw window & door flash Flashing Membrane PRODUCT DATA *

SECTION SLATE SHINGLES. 1.1 SUMMARY A. Section Includes: 1. Slate shingles over underlayment nailed to roof sheathing.

HERITAGE LAMINATED ASPHALT SHINGLES Tuscaloosa, AL

TAMKO. TW MOISTURE WRAP Above Grade Moisture / Air Barrier Membrane PRODUCT DATA

SECTION 9: ROOF STRUCTURE, ROOFING MATERIALS AND FLASHING, GUTTER, DOWNSPOUTS, AND SKYLIGHTS. Background

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights

Application instructions

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

I n s t a l l i n g Enviroshingle APPLICATION INSTALLATION GUIDELINE

ONDUVILLA. The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S

SECTION ASPHALT SHINGLES

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25

How To Install Asphalt Shingles. Part 1 of 3: Preparing the Roof. Tutorial

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

1.04 QUALITY ASSURANCE

SECTION WOOD SHINGLES

Application instructions

4. Metal roof jacks at penetrations and attachments

SECTION ASPHALT SHINGLES

Installation Instructions

Louisiana Roof Tarping Manual

Roof 50% REDUCE STORM DAMAGE

Slate Shingle Specifications

ROOFING APPLICATION STANDARD (RAS) No. 130

BARDOLINE INSTALLATION INSTRUCTIONS

Turada Hardwood Shingles and Shakes Installation instructions

HUB REV 9/18 ROOF INSTALLATION MANUAL ZIPSYSTEM.COM

THREE-TAB SHINGLES. YOUR OBJECTIVE: To learn the correct procedures for installing three-tab type strip shingles.

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

Multi-Width Shake. Widths: 9", 8", 7", 6", 4" Length: 22" Thickness at butt: 5/8" Single-Width Shake. Widths: 9" Length: 22" Thickness at butt: 5/8"

The proposal includes the replacement of the roof on the entire house (historic massing and later additions) and detached garage.

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

RED DIAMOND SHINGLES Roof Installation Introduction:

9Upgrades to Windproof Your Roof

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

RESIDENTIAL ROOFS ADDENDUM NUMBER ONE. August 28, 2017

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

ROOFING City of Grand Rapids Building Safety Division

Brava Old World Slate Installation Guide

Barrel Vault Counter Batten and Batten

PROJECT INSTRUCTIONS Roofing

Hip & Ridge Shingles Installation Instructions

ForceField Air & Water Barrier System. installation instructions

AIA Specification. Section Slate Shingles PART 1 GENERAL

A201 3 PROPOSED SOUTH ELEVATION SCALE: PROPOSED EAST ELEVATION SCALE: EXISTING EAST ELEVATION EXISTING SOUTH ELEVATION WEST WORKSHOP

SUPER-UNDERLAY SHEET

Inspire Aledora Slate Application Guidelines

IRONWOOD SHAKE & FLASHING SPECIFICATIONS

Installation Instructions

Table of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1

IRONSTONE SLATE & FLASHING SPECIFICATIONS IRONSTONE SLATE

Capstone Application Instructions

10 Steps to Performing a Roof Inspection Class. Ben Gromicko InterNACHI nachi.org/class

MetroCOTTAGE Shingle

Installation Guide. Titan Old World Slate REV Titan Manufacturing Phone: (407) Fax: (866)

The Roofing Industry Committee

INSTALLATION MANUAL. ZIP System Roof & Wall Sheathing FASTER. TIGHTER. ENERGY EFFICIENT.

ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years.

Tuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311

Steel Shingle Installation Guide

Shingle Underlayments and Flintlastic

installation guide 7 8 Corrugated corrugated metal panel

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

Improving the Wind Resistance of Roof Systems: Asphalt Shingle Roofs

Stone coated steel roof tile INSTALLATION GUIDE

installation guide Villa

SIGNATURE CUT SHINGLES. Getting Started

Polytegola N. Bitumen Roof shingles. Application guide

Building Wrap and Flashing

Transcription:

SOMEDAY ALL UNDERLAYMENT WILL BE LIKE RAPTOR Meets or Exceeds ASTM D226, D4869, D1970, D146 Class A Fire Rated with Asphalt Shingles ASTM E108-11 Perm rating.061 ASTM E 96 ed Requirements for ICC ES AC188(2012) ICC applied for File # 13-10-12 Weight 27 # 10 square roll measures 4 x 250 or 5 x 200

Imagine a roofing underlayment you can install with regular roofing nails. That won t tear or blow off the roof. That lies flat and stays flat, with a black surface that dries off quickly and shows chalk lines clearly. An underlayment with incredible traction, wet or dry. Now imagine all of this for less than the cost of #30 asphalt saturated felt. Imagine Raptor Synthetic Roofing Underlayment Raptor is a unique combination of woven polypropylene, binders, tackifiers, and non-woven polymers. Lightweight but tough, Raptor has incredible traction, wet or dry and will not tear or blow off the roof.

Safety First The first rule of fall prevention is don t slip, and Raptor has been designed to provide the safest walking surface possible for contractors moving around on steep-sloped roofs. It provides incredible traction wet or dry. Slippery residues will not build up on the soles of roofer s shoes. It won t tear easily, eliminating the slip hazard created with loose and torn asphalt felt. Raptor is black, but there is no mass to heat up, creating a product that remains cooler to the touch than regular felt. Raptor weighs only 27 pounds and one roll will cover 9 to 10 squares of decking. Fewer trips up the ladder and ergonomically better for the back. Raptor will significantly reduce the likelihood of slipping, BUT IT DOES NOT TAKE THE PLACE OF A PROPERLY DESIGNED AND IMPLEMENTED FALL PREVENTION PLAN. Slide guards should be properly installed along the eaves of every roof. Guardrails, full body harnesses or positioning belts need to be available and used when appropriate. As a component of an effective fall prevention plan, Raptor Synthetic Underlayment can help ensure that everyone working on the roof returns home safely each night.

Roofer Friendly Raptor was designed specifically for roofing contractors. Regular roofing nails provide the best protection from water infiltration, and are the preferred fastener for Raptor. Cap nails may be used if required by code, but are not necessary. Staples can be used, but only if you plan to roof within a few days or before any severe weather. Fasteners should be concentrated in the horizontal laps, and placed sparingly in the field. Raptor is black by design. The dark surface will dry off quickly and show chalk lines clearly, yet Raptor s low mass keeps the surface much cooler than asphalt saturated felt. Raptor weighs only 27 pounds for a 10 square roll. Easier to carry and fewer trips up the ladder. Available in 4 or 5 widths, Raptor installs much faster and uses fewer fasteners than standard felt.

Builder Friendly It can be left exposed for up to six months and will not tear or blow off the roof. No more torn or missing felt to replace before the shingles can be installed. Raptor lays flat and stays flat. No more wrinkles telegraphing through today s lighter weight shingles. Raptor is a suitable underlayment for use under all roofing materials.

Raptor Synthetic Underlayment Installation Instructions Raptor should be installed with the black surface (printed surface) facing up. Horizontal seams should be lapped four inches and vertical side seams should be lapped six inches. Fasteners should be concentrated in the horizontal seams. To prevent wind blown rain from penetrating the vertical seams we recommend taping those seams with a quality, six inch flashing tape. There will only be a few vertical seams on every roof, and this simple trick can protect those laps until the shingles are applied. Proper Placement of Metal Drip Edge Raptor should lap over the drip cap at the bottom (eave edge) of the roof. If the framers install the Raptor before the roofers arrive, they should keep the fasteners at least three inches from the bottom of the roof, so that the roofers can properly slip the drip cap under the Raptor. Drip cap should lap over the raptor along the eaves. This will prevent wind blown rain from getting under the underlayment, and will help prevent wind damage to the underlayment before the shingles are installed. Fastening Raptor to the Deck The correct location for fasteners is clearly printed on the surface of the Raptor Synthetic Underlayment. For normal application, place a nail in each of the printed O s and ignore the printed X s. Fasteners for Raptor should be concentrated in the horizontal laps. When using regular roofing nails or large headed cap nails, fasteners should be spaced every 12 inches in the seams and staggered every 24 inches along two rows in the field of the underlayment. Regular roofing nails with a 3/8 head provide the best protection against water infiltration, and are our preferred fastener for most Raptor applications. One inch cap nails may be used when required by code or if unusually high winds are forecast, but are typically unnecessary. Raptor may be left exposed for up to six months using regular roofing nails or cap nails. For extended periods of time or extreme weather conditions, twice as many nails may be installed by placing fasteners in both the O s and the X s printed on the Raptor. Staples are commonly used to install asphalt saturated felt, and will perform just as well with Raptor. Staples should only be used if the roofing materials will be installed within a few days. A continuous line of staples should be placed along the seams, with only a few staples in the field. Raptor s superior tear strength allows you to install raptor using far fewer staples than you may have used with organic felt. Recommended Stapling Pattern For Raptor Nailing Pattern For Raptor In Normal Conditions Waterproofing a Roof with Raptor Synthetic Underlayment Underlayment is not roofing, and whether you re using Raptor, organic felt, or another synthetic underlayment, you should never count on underlayment to make a roof leak proof. Tarps should always be used for extra protection when leaving a re-roof unfinished for the night. However, water will not pass through intact Raptor Synthetic Underlayment, and if you will use the following tips, very little water will enter the building. Lap the seams correctly: 4 horizontal, 6 vertical (side) Tape the vertical seams with a good flashing tape Concentrate the fasteners along the seam laps, where there is a double coverage of underlayment. Install metal drip edge along the rake to prevent water from blowing under the Raptor and minimize blow offs Use flashing tape to seal the Raptor to the valleys and roof/wall interfaces, which is also great first step to waterproofing the finished roof. Cover the ridge with a good flashing tape or ice and water barrier

AC188 TEST RESULTS SUMMARY Test Description Standard Test Requirement Test Results /Fail Pliability ASTM D146 section 14 No cracking shall occur when bent 90 at a uniform speed over a rounded corner of ½-inch radius. No cracking occurred Acellerated Aging AC48 Section 4.7 No visible damage to the specimens such as cracking, chipping or delamination shall occur. No visible damage Occurred UV Exposure AC48 Section 4.8 No visible surface or structural changes such as peeling, chipping, cracking, flaking or pitting shall occur when observed under a minimum of five-power magnification. No Visible Changes Occurred Tensile Strength AC48 Sections 4.1, 4.7, 4.8 and ASTM D1970 Control, accelerated-aged, and ultraviolet samples shall have a minimum breaking strength of 25 lbf/in-width for both machine and cross-directions. Control Samples: CD= 40 lbf, MD= 71 lbf Aged Samples: CD= 37 lbf, MD= 77 lbf UV Exposed Samples: CD= 40 lbf, MD= 80 lbf Adhesion In Peel This was not a requirement for this product, as it is not an adhered membrane. Liquid Water Transmission ASTM D4869 Section 8.3.5 Shall meet the requirements of Section 8.3.5 of ASTM D4869 Cycling & Elongation This was not a requirement for this product, as it is not an adhered membrane. Unroll-ability AC188 Section 3.2 The finished product shall not crack or become so sticky as to cause tearing or other damage, upon being unrolled at temperatures between 50 F and 140 F (10 C and 60 C). No cracking, tearing or other damage was observed upon being unrolled at specified temperatures Water-vapor Transmission PER ASTM E 96 Water Vapor Transmission (g/m²/hr) 0.061 Warranty 25 Year Non-Woven Bonding Film Woven Scrim Non-Slip Coating Raptor 4 Layer Construction

Someday, all underlayment will be like Raptor Why wait? Find A Location Near You At www.raptorunderlayment.com