AccuSine PCS Active Harmonic Filter. Cruising through rough waves in your electrical network

Similar documents
AccuSine PCS Active Harmonic Filter. Cruise through rough waves in your electrical network

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Active Harmonic Filter

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Reliable power onboard and offshore

Low Pass Harmonic Filters

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

PowerGard Series C 18-Pulse Enclosed Drive Controllers

Active Harmonic Filter (AHF)

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

Phoenix DX Clean Power (18 Pulse) AC Drive

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Active Harmonic Filters IPC150 AHF Series

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

CASE STUDY. Implementation of Active Harmonic Filters at Ford Motor Company SA Silverton Plant

Active Harmonic Filtering Solutions. Catalogue. Active Harmonic Filtering Solutions. Schneider Electric Industries SAS

Harmonic Distortion and Variable Frequency Drives

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

Effective Harmonic Mitigation with Active Filters

Technical Paper. Harmonic Distortion in Data Centers

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

Power IT LV Active Filters PQFA - PQFL - PQFT

PowerFlex 400 Submittal

Gutor PxW AC UPS Designed for North American Market

TOSHIBA International Corp

Understanding Harmonics

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

VFDs and Harmonics in HVAC Applications

NJWA - Harmonics and Drives Proper System Design

AF91 Adjustable Frequency Drives Series B

Multimeter 500CVD21 RTU500 series

SHUNT ACTIVE POWER FILTER

ABB DRIVES Technical guide No. 6 Guide to harmonics with AC drives

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS

Meduim Voltage Drives

Harmonics White Paper

S11 Adjustable Speed Drive Engineering Specification

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Thyristorised Automatic Power Factor

Orbital GFI Inverter Series

LINEATOR. Advanced Universal Harmonic Filter

ULTRA-K Series 600K - he

Power factor correction. AccuSine. Harmonic filtering and reactive power compensation. Catalogue 2012 PE90001

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

THE FIRST STEP IN THE RESOLUTION OF VOLTAGE DISTORTION FOR SHARED GENERATORS AND MV UNDERSEA RING MAIN IN AN OFFSHORE OIL FIELD

Harmonic control devices. ECE 528 Understanding Power Quality

APPLICATION GUIDE. Harmonics in HVAC applications

Understanding Input Harmonics and Techniques to Mitigate Them

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

PowerMonitor 5000 Family Advanced Metering Functionality

Harmonics, its Mitigation & Result of Case study of Spinning Mill

CHAPTER 4 HARMONICS AND POWER FACTOR

Harmonic control devices

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

VF-nC1 Adjustable Speed Drive Engineering Specification

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

The increase in the application

FCL VOLTAGE & FREQUENCY CONVERTERS. FCL H SERIES - SINGLE PHASE - 2 to 30 kva H SERIES MODELS. AC SINGLE PHASE 2 TO 30 kva STATIC VARIABLE AC

1 INTRODUCTION ORDER CODE / INFORMATION

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Economical Solutions to Meet Harmonic Distortion Limits[4]

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

ULTRA RAPID POWER QUALITY ANALYZER

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

Please use the Q & A utility to ask us any questions concerning the material being presented.

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

7/15/2002 PP.AFD.08 1 of 28

ADJUSTABLE SPEED DRIVES FS1

Power Quality improvement of a three phase four wire system using UPQC

Drives 101 Lesson 5. Power Input Terminology for a VFD

Design Specifications Low Voltage Active Harmonic Filter

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

Harmonics Elimination Using Shunt Active Filter

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

Power Quality and Circuit Imbalances Northwest Electric Meter School Presented by: Chris Lindsay-Smith McAvoy & Markham Engineering/Itron

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

TMdrive -XL Series Family Product Application Guide. solar inverters. power generation

APPLICATIONS. AFQ Active Multi-Function Filter. AFQ solves thousands of problems in countless types of installations, in particular the following:

DOBLE F6150SV TECHNICAL SPECIFICATIONS

How do I Implement Hybrid Solutions for LV Dynamic Power Factor Correction

An Introduction to Power Quality

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

E3 Adjustable Speed Drive Engineering Specification

Harmonic Filters for Single Phase Equipment

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

Transcription:

AccuSine PCS Active Harmonic Filter Cruising through rough waves in your electrical network

The Schneider Electric AccuSine power correction system (PCS) injects harmonic current to cancel harmonic current in the electrical distribution system. This reduced harmonic level results in improved electrical network reliability and reduced operating cost. AccuSine PCS is simple to size, install, set up and operate. In addition, AccuSine PCS eliminates the complex harmonic compliance limit calculations and removes nuisance harmonics from the electrical network.

How can active harmonic filters solve power quality issues in your facility? Power electronic devices that have rapid and frequent load variations have become abundant today due to their many process control related and energy saving benefits. However, they also bring a few major drawbacks to electrical distribution systems; harmonics and rapid change of reactive power requirement. Harmonics may disrupt normal operation of other devices and increase operating costs. Rapid reactive power changes demand timely reactive power (VAR) compensation. Symptoms of problematic harmonic levels include overheating of transformers, motors, drives, cables, thermal tripping of protective devices and logic faults of digital devices. In addition, the life span of many devices can be reduced by elevated operating temperature. Lack of timely and adequate VAR compensation can lead to voltage fluctuations in the electrical distribution system, impacting equipment operation, as well as product quality. The AccuSine PCS active harmonic filter (AHF) provides the simplest and most effective means to mitigate harmonics, reduce process-related voltage fluctuations, and improve equipment operating life and system capacity. AccuSine PCS can be placed in various locations within the electrical distribution network

Typical applications Applications Requirements Benefits Water and wastewater treatment plants, textile mills, paper mills, pharmaceutical facilities, steel mills, package sorting facilities, oil platforms and marine vessels Smelters, induction furnaces, DC drives and cranes Data centers, hospitals and microelectronic manufacturers Welders, linear induction motors, windmills, Solar farms, X-ray and MRI machines Total voltage distortion: THD(V) to be < 5%, Total Demand Distorsion to meet equipment operating environment to prevent damage to other equipment in the facility Fast reactive power compensation in rich harmonic operating environment Critical uptime requirements incorporate backup power systems with generators, UPS Ultra-fast VAR compensation Reduce harmonics to meet industry standards Reduce harmonic effects on equipment Increase system capacity by improving total power factor Eliminate highly-fluctuating harmonic content Provide real-time supply of reactive power to improve system voltage regulation Reduce harmonics Correct leading power factor when blade servers are used on the output of UPS Provide ultra-fast VAR compensation to ensure stable voltage level for the process Eliminate flicker Improve diagnostic machine uptime

Key features and benefits A simple line up, including Power rating: 50 A, 100 A and 300 A, universal voltage: 208 480 V, 3- phase/3-wire (3P/3W) Enclosure options: NEMA 1, NEMA 12, IP30, IP54 Worldwide offer: meets UL, CSA, CE, ABS, C-Tick standards Powerful performance Meets all major worldwide harmonic standards; IEEE-519, G5/4-1, GB/T 14549, IEC 61000-3-2/-3-4/ -3-12 Ultra-fast response to load changes within microseconds Cancels all harmonics from 2 nd to 50 th order 225% VAR current injection to meet instantaneous load requirements and provide voltage support Expandable capabilities Parallel up to ten units with different ratings on one set of current transformers Easy to control Highly-visible QVGA screen, multi-language capability Unit operating status, load profiles displayed on 3.8 in. screen Clear on screen operating start and stop touch buttons Modbus communication capability Paralleling more than ten units is possible; consult Schneider Electric for details.

Active harmonic filter operating principle The AccuSine PCS injects harmonic and reactive current to limit the harmonic distortion and improves displacement power factor for the electrical distribution system in any facility. As a full spectrum product, AccuSine PCS measures the entire load current, removes the fundamental frequency component and injects the inverse of the remaining wave form for nearly complete cancellation of harmonic current. AccuSine PCS s full spectrum circuitry is not focused on specific frequencies; rather it creates a waveform on the fly based upon the input of its sensing circuitry, regardless of the particular frequencies that the non-linear load current contains. AccuSine PCS monitors the load through current transformers mounted on the AC line (figure A below), feeding the loads of concern. This information is analyzed by the logic to determine the amount of correction to be injected into the AC lines from the parallel installed AccuSine PCS. I a I S I l Figure A Most active harmonic filters today are designed with two types of control schemes. One uses Fast Fourier Transforms (FFT) to calculate the amplitudes and phase angle of each harmonic order. The power devices are directed to produce a current of equal amplitude but opposite phase angle for specific harmonic orders. This limits the response to specific harmonic orders and may require up to two or more cycles (> 33 milliseconds) before responding. The other control scheme (as used by AccuSine PCS) is called a full spectrum cancellation. This control scheme doesn t perform FFT. The control algorithms are analog. The logic acquires the current sample from the current transformer, removes the fundamental frequency component and starts injecting the correction within several hundred microseconds. In this manner, all non-fundamental noise is removed for the electrical source. This noise may contain non-integer frequencies, also known as inter-harmonics.

Application Guide AccuSine PCS can easily be applied to various applications. It can be used in conjunction with other power quality correction equipment, such as tuned harmonic filters, capacitor banks, etc. However, as with any electrical equipment, we need to examine each application carefully to ensure proper selection and application. AccuSine PCS can be placed in various locations within the electrical distribution network (figure B below). Multiple units (up to ten) can be connected in parallel to provide higher compensation current to meet the TDD levels defined in IEEE519-1992 standard or in the plant operating requirements. An important prerequisite when applying AccuSine PCS is to install a 3% or higher impedance line reactor or equivalent in front of each non-linear load, such as VFD, UPS or SCR power supply. Figure B

Unit rating determination For a new facility or facility with a known load list, we can use the AccuSine PCS selection program to calculate the AccuSine system rating required to meet the system objective. An Excel -based tool, the AccuSine PCS selection program can be downloaded from our website www.reactivar.com. For example, an industrial facility has a requirement to meet a current total demand distortion (TDD) level of 8%. We collect the system information as follows: Transformer rating System voltage 2,000 kva, with 5% impedance 480 V Desired TDD level 8% Non-linear load list Total linear load 2 x 150 kva UPS (Diode converter) 6 x 50 HP VFD (PWM) 6 x 20 HP VFD (PWM) 20 x 10 HP VFD (PWM) 2 x 100 HP VFD (PWM) 400 kva The following summary is from the AccuSine PCS selection program. Electrical system voltage All loads total All linear loads total 480 V 1,828.3 A 481.1 A Original displacement power factor 0.950 Objective displacement power factor 0.950 TDD of the electrical system before AccuSine PCS Objective TDD Required rating of the AccuSine PCS system 17.06% TDD 8.00% TDD 245.9 A of correction The AccuSine PCS selection program calculates that, in order to meet the 8% TDD requirement, an AccuSine PCS-rated 245.9 A RMS is required. In this case, a 300 A rated unit should be specified (in this example, 5% TDD can be achieved due to 300 A unit is selected or additional VAR compensation capacity can be obtained). For an existing facility where a detailed load list is not available, but the historic harmonic and load current data of the system can be obtained through advanced metering, please contact a Schneider Electric sales office for sizing assistance.

AccuSine Product specification Standard RMS output current ratings Nominal voltage Other voltages Nominal frequency Number of phases Power electronics Topology Operation with single-phase loads Current transformers (CT) 50 A, 100 A, 300 A 208 480 V ±10% auto-sensing With transformer 50/60 Hz ±3 Hz auto-sensing 3P/3W, 3P/4W IGBT Analog/digital interface Yes Number of CTs required 2 or 3 Normal spectrum of compensation Attenuation ratio > 10:1 Parallel multiple units CT location Power factor correction Response time Overload Dynamic current injection Display Languages Operators Display parameters Communication capability Heat losses Noise level (ISO 3746) Color Operating temperature Relative humidity Seismic qualification 1,000/5, 3,000/5, 5,000/5 (400 Hz) 2 nd to 50 th harmonic global Yes, up to 10 per set of CTs (any rating combinations) Either source or load sensing Yes, leading or lagging injection to target power factor 100 microseconds for step load changes, 1 cycle full response Limited to nominal output, continuous operation Up to 2.25 times rated current High quality 3.8 in. QVGA screen English, with other language capability Magelis XBT graphic touch screen terminal AC line voltage, DC bus voltage, load power factor, output power factor Load harmonic current, load reactive current, output harmonic current, corrected load current Various fault codes, set up parameter points, start/stop control screen Modbus, Modbus TCP/IP N1 unit: 1,800 W for 50 A, 3,000 W for 100 A, 9,000 W for 300 A N12, IP units: 2,150 W for 50 A, 3,700 W for 100 A, 10,000 W for 300 A < 80 db at one meter from unit surface NEMA 1 quartz gray, all others RAL7032 0 C to 40 C continuous 0 95% non-condensing IBC and ASCE7 Operating altitude < 1,000 m (derating factors apply for higher altitudes @10% per 1,000 m) Protection (enclosure) Optional: CE EMC certification NEMA 1, NEMA 12, IP30, IP54 IEC/EN60439-1, EN61000-6-4 Class A, EN61000-6-2

AccuSine selection information AccuSine PCS selection table Rated current Max. reactive power (kvar) Catalog number Enclosure information Frame size Weight f A (rms) 208 V 400 V 480 V Rating Style/cable entry Figure # Lbs (kg) PCS050D5N1x PCS050D5N15Sx b PCS050D5N16Sx NEMA 1 Wall-mount/ bottom a 1 250 (114) 50 18 34.6 41.6 PCS050D5N12Dx e PCS050D5N125SCx e NEMA 12 PCS050D5N126SDx e PCS050D5CE305SCx ce IP30 (CE certified) PCS050D5CE545SCx ce IP54 (CE certified) PCS050D5IP305SCx e IP30 PCS050D5IP545SCx e IP54 PCS100D5N1x PCS100D5N15Sx NEMA 1 PCS100D5N16Sx Floor-standing d / top or bottom 4 661 (300) Wall-mount/ bottom a 2 350 (159) 100 36 69.2 83.1 PCS100D5N12Dx e PCS100D5N125SCx e NEMA 12 PCS100D5N126SDx e PCS100D5CE305SCx ce PCS100D5CE545SCx ce PCS100D5IP305SCx e PCS100D5IP545SCx e PCS300D5N1x PCS300D5N15Sx PCS300D5N16Sx IP30 (CE certified) IP54 (CE certified) IP30 IP54 Floor-standing d / top or bottom 5 771 (350) NEMA 1 Floor-standing d /top 3 775 (352) PCS300D5N12Dx e NEMA 12 300 108 207.8 249.4 PCS300D5N125SCx e PCS300D5N126SDx e PCS300D5CE305SCx ce PCS300D5CE545SCx ce PCS300D5IP305SCx e IP30 (CE certified) IP54 (CE certified) IP30 Floor-standing d / top or bottom 6 1,212 (550) PCS300D5IP545SCx e IP54 x = 5 for 50 Hz; x = 6 for 60 Hz. N1/N12 version are rated 50/60 Hz a: Floor stand can be ordered with part number FSPCS100N1 b: S model is used outside of U.S. c: CE certified units meet EMC Directive 89/336 EEC d: Floor-standing units include a door-interlocked main disconnect e: C = 380 415 V fan, D = 480 V fan f: Weight information is subject to change without notice Round split-core CT selection table Ampacity Catalog number Dimensions (in.) Weight A (ID) D (OD) (lbs) Accuracy (%) Burden capacity (VA) Secondary current (A) 1,000 CT1000SC 4.0 6.5 3.50 1 5 5 3,000 CT3000SC 6.0 8.5 4.25 1 45 5 5,000 CTFCL500058 8.0 10.5 5.50 1 45 5 Three CTs required for networks with single-phase loads. Two CTs required for three-phase loads. For installations requiring parallel connection of multiple AccuSine units, special considerations is required, and additional CT may be needed. Contact Schneider Electric for details. 10

11

Installation guidelines AccuSine PCS is provided in enclosures with four different ratings: NEMA 1, NEMA 12, IP30 and IP54. They are suitable for indoor, well-ventilated, clean environments with ambient temperature ranging from 0 C to 40 C. For dusty environments (such as mining operations, steel factories, paper mills), a filtered and air-conditioned utility room is required (to maintain ambient temperature and remove conductive dust), and a NEMA 12 or IP54 unit is recommended. AccuSine PCS AHF unit dimensions Frame size (Figure) Exterior dimensions Height Width Depth in. mm in. mm in. mm 1 48.0 1,219 20.7 525 18.5 469 2 64.9 1,648 20.7 525 18.5 469 3 75.3 1,913 31.5 801 19.6 497 4/5 75.0 1,905 31.5 801 23.8 605 6 90.7 2,303 39.4 1,000 31.7 805 For detailed installation instructions, please refer to installation bulletin 5820IB0802. Chassis unit information is available upon request. 12

Frame size Frame size Frame size Front view Side view Front view Side view Front view Side view Frame size Frame size & Front view Side view Front view Side view Consult factory approval or record drawing with final dimensions. 13

Harmonic-related information and definitions Definitions Harmonics in the electrical network is a phenomenon gaining more attention in recent years. To help the reader follow the terminologies used in this brochure, the definitions of different terms related to harmonic phenomena are described below. Today in AC industrial electrical distribution networks, the variation of current and voltage with time is considerably different from that of a pure sine wave. The actual waveform is composed of a number of sine waves of different frequencies, including one at the generating power frequency, referred to as the fundamental component. a. Harmonic component: any one of the sinusoidal components in which frequency is an integer multiple of the fundamental component. b. Harmonic order: the harmonic order is the ratio of the frequency of the harmonic component to that of the frequency of fundamental. By definition, the harmonic order of the fundamental is equal to 1. Note that the harmonic of order n is often referred to simply as the nth harmonic. c. Spectrum: the spectrum is the distribution of the amplitudes of the various harmonics as a function of their harmonic order, often illustrated in the form of a histogram. d. Expression of distorted wave: the Fourier series expression of distorted wave is as follows: e. where; y 0 = the amplitude of the DC component, which is generally zero in AC distribution systems. y n = the rms value of the nth harmonic component. = phase angle of the nth harmonic component when t = 0. RMS value of a distorted wave: harmonic quantities are generally expressed in terms of their rms value since the heating effect depends on this value of the distorted waveform. For distorted quantity, under steady-state conditions, the energy dissipated by the Joule effect is the sum of the energies dissipated by each of the harmonic components: i.e.: where; if the resistance can be considered as constant. f. Individual harmonic ratio and total harmonic distortion: the individual harmonic ratio and total harmonic distortion ratio quantify the harmonic disturbances present in the distribution network. The individual harmonic ratio expresses the magnitude of each harmonic with respect to the fundamental. Typically referred to as THD, total harmonic distortion quantifies the thermal effect of all the harmonics. It is the ratio of the rms value of all the harmonics to that of the fundamental. IEEE 519-1992 has defined THD in mathematic formula below: where; y 1 is the fundamental component. 14

g. Total demand distortion (TDD): TDD is defined in IEEE519-1992 as: where; y 1 is the maximum demand load current of the facility within 15 or 30 minute demand window. Harmonic effects on electrical distribution network a. Instantaneous effects Electronic devices Harmonics can disrupt controllers used in electronic systems and can adversely affect thyristor switching due to displacement of the zero-crossing of the voltage wave Harmonics can cause vibrations and noise in electrical machines (motors, transformers, reactors) Harmonics also reduce available system capacity b. Long-term effects Capacitor heating and degradation (capacitance loss) Heating due to additional losses in transformers Heating of cables and equipment Thermal damage to induction motors and generators Standards Most equipment have limits on the permissible harmonic content in the electrical system during operation. These limits can be found in the library of various standards. The following are general limits on various electrical equipment: a. Synchronous machines: permissible stator current distortion < 1.4% b. Asynchronous machines: permissible stator current distortion; 1.5% to 3.5% c. Cable: permissible core-shielding voltage distortion < 10% d. Electronic equipment: 5% voltage distortion with a maximum individual percentage of 3% depending on the equipment e. Transformer: permissible current distortion < 5% at full load Most utilities have adopted standards to limit the harmonic content at the point of common coupling (PCC). Standards adapted around the world include, but not to limit to: US/Canada...IEEE 519 International...IEC61000 3-2, 3-4, 3-12 United Kingdom...G5/4-1 China...GB/T 14549 15

A wide range of Power Quality products meet your facility solution needs @ Low Voltage Capacitor banks _ Varset classic or comfort : suitable for networks with low or medium harmonic level _ Varset harmony : suitable for networks with high harmonic level _ Varset fast : suitable for applications requiring real-time correction and/or transient free capacitor switching _ Passive filtering : - From 230 V to 690 V - Harmonic orders : H5, H7, H11 - Reactive power : up to 265 kva @ Medium Voltage Capacitor banks _ CP 200 series of capacitor bank : - Fixed or automatic medium voltage capacitor bank - Range suitable for any type of network AccuSine, Varset, Modbus and ReactiVar are trademarks or registered trademarks of Schneider Electric and/or its affiliates in the United States and/or other countries. Other marks used herein may be the property of their respective owners. Schneider Electric Industries SAS 399, rue de la Gare 74370 Pringy France Tél : +33 (0)4 50 66 95 00 Fax : +33 (0)4 50 27 24 19 http://www.schneider-electric.com Due to changes in standards and equipment, the characteristics indicated in the texts and images contained in this document can only be considered as binding when confirmed by our organisation 2009 Schneider Electric. All rights reserved. Document Number DMEED108005EN_01 6-09 tk