Analysis of Reference Current Generation for Shunt Active Power Filter Using SRF Algorithm to Compensate Harmonic Current

Similar documents
ABSTRACT I. INTRODUCTION

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Performance Analysis of Shunt Active Power Filter Base On Active Reactive Power Theory

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

Control Of Shunt Active Filter Based On Instantaneous Power Theory

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

Power Quality Improvement of Non-Linear Load by Using Instantaneous P-Q Theory

Power Quality Improvement using Shunt Passive Filter

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

Active Harmonics Filtering of Distributed AC System

Cascaded Multilevel Inverter based Active Filter for Power Line Conditioners using Instantaneous mitigates

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

SCIENCE & TECHNOLOGY

Literature Review for Shunt Active Power Filters

A CONTROL TECHNIQUE FOR INSTANT MITIGATION OF VOLTAGE SAG/SWELL BY DYNAMIC VOLTAGE RESTORER

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

SHUNT COMPENSATOR USED FOR POWER QUALITY IMPROVEMENT

NEUTRAL CURRENT COMPENSATION USING FOUR LEG SHUNT ACTIVE POWER FILTER

2020 P a g e. Figure.2: Line diagram of series active power filter.

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Comparative Analysis of Harmonics with and Without Shunt Active Power Filter

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

Mitigation of Line Current Harmonics Using Shunt Active Filter With Instantaneous Real and Reactive Power Theory

Kanuru; Krishna (Dt); A.P, India. DOI: / Page. 1 G. Aruna Jyothi, 2 DR. P. V. R. L.

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Synchronous Reference Frame Control Algorithm Based Four -Leg Inverter DSTATCOM For Power Quality Improvement

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

This SRF theory is experimentally implemented with dspace module CP1104 which has been used for real time interfacing.

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

Selective Harmonic Elimination Using Three Phase Shunt Active Power Filter

POWER QUALITY IMPROVEMENT USING SHUNT ACTIVE FILTER

Assessment of Different Compensation Strategies in Hybrid Active Power Filters

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

Indirect Current Control of LCL Based Shunt Active Power Filter

KKR &KSR institute of Technology and sciences,vinjanampadu(v),vatticherukuru(m) Guntur(D) , Andhra Pradesh,India. I.

Power Control Scheme of D-Statcom

Shunt Active Power Filter for Compensation of System Harmonics

Comparison of Various Reference Current Generation Techniques for Performance Analysis of Shunt Active Power Filter using MATLAB Simulation

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Simulation Study of PWM Techniques for Voltage Source Converters

Comparison of Control Algorithms for Shunt Active Filter for Harmonic Mitigation

Compensation of Harmonics Power by using Shunt Active Filter

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

Power Quality improvement of a three phase four wire system using UPQC

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Harmonics Reduction of 3 Phase Diode Bridge Rectifier by Implementing P-Q Theory with Active Filter

Universal power quality conditioner

SIMULATION AND COMPARISON OF SPWM AND SVPWM CONTROL FOR TWO LEVEL UPQC

Review on Shunt Active Power Filter for Three Phase Four Wire System

A MATLAB-SIMULINK APPROACH TO SHUNT ACTIVE POWER FILTERS

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

PI Controller Based Shunt Active Power Filter with Cascaded Multilevel Inverter

CURRENT HARMONICS REDUCTION IN 3 PHASES 4 WIRE SYSTEM USING HYBRID FILTERS R.Saravanakumar 1#, S.Amritha 2#

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

Comparison of Shunt Active Power Filter Control Strategies for Harmonic Compensation in a Paper Industrial Factory

Experimental Results of a Single-Phase Shunt Active Filter Prototype with Different Switching Techniques

PLL Synchronization with PID Controller Based Shunt Active Power Line Conditioners

A MATLAB Model of Hybrid Active Filter Based on SVPWM Technique

International Journal of Advance Research in Engineering, Science & Technology

POWER QUALITY IMPROVEMENT IN 3-ϕ POWER SYSTEM USING SHUNT ACTIVE FILTER WITH SYNCHRONOUS DETECTION METHOD

Design of Shunt Active Filter to Improve Power Quality using Pq Theory

A Hysteresis based Active Shunt, Passive Series Hybrid Filter for Power Quality Improvement

Hamdan bin Daniyal. University Malaysia Pahang Mohd Herwan Sulaiman

Control Strategy for a cross phase connected and a conventional UPQC

Mitigation of Voltage Sag, Swell and Load Hamonics by the Combined Opertation of Series APF and Solar System

Power Quality Improvement using Active shunt Power filter using PI Controller

Virtual Instrumentation Applied to Calculation of Electrical Power Quantities in Single-Phase Systems


Multi Level Inverter Based Active Power Filter for Harmonic Reduction

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Key-Words: - NARX Neural Network; Nonlinear Loads; Shunt Active Power Filter; Instantaneous Reactive Power Algorithm

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Comparison of Reference Current Extraction Methods for Shunt Active Power Filters

Design of UPQC with constant frequency controlled scheme for removal of Total Harmonic Distortion

ISSN Vol.03,Issue.42 November-2014, Pages:

Simulation Results of a Shunt Active Power Filter with Control Based on p-q Theory

Investigation of D-Statcom Operation in Electric Distribution System

COMPENSATION OF POWER QUALITY PROBLEMS USING ACTIVE POWER FILTER

Shunt active filter algorithms for a three phase system fed to adjustable speed drive

SPWM Switching Strategy for Compensation of Unbalanced and Non Linear Load Effects in Three Phase Four Wire System Using D-Statcom

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Exploration in Power Quality Furtherance on Shunt Active Power Filter

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

Active Power Filter with Fast PI Controller Using Matlab/simulink

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Power Factor Improvement Using a Three Phase Shunt Active Power Filter

Power Quality improvement with Shunt Active Power filter using p-q control technique

Transcription:

BUSINESS AND TECHNOLOGY (IJSSBT), Vol., No., June 05 ISSN (Print) 77 76 Analysis of Reference Current Generation for Shunt Active Power Filter Using SRF Algorithm to Compensate Harmonic Current Mr. S. M. Shembekar, Mr. K. L. Deshmukh, Assistant Professor, M.E (EPS) (Pursuing),, Department of Electrical Engineering,, S.S.B.T s COET Bambhori, Jalgaon, India, smshembekar@gmail.com deshmukh_kalpesh@ymail.com Abstract Number of power electronic devices used in the power system to control the equipment. These power electronic devices are responsible to produce Harmonics in the system. These harmonics may pollute the entire power system. So it is necessary to develop the system for solving these harmonic problems. At the beginning LC filter, Passive filter and Active filter has been developed. But due to the drawback of passive filter and LC filter they are less in use. So importance is being given to the Active Power Filters to solve these problems of harmonics. Amongst them shunt active power filter is used to eliminate voltage and load current harmonics and for reactive power compensation. The shunt active power filters have been developed with a controlled strategy like p-q theory, PI controller, Sliding mode control. In this paper reference current is determined for compensation of harmonics source current with the help of Synchronous Reference Frame Algorithm Method. Park transformation is used to determine the reference current. Hysteresis band current control (HBCC) technique is used for the generation of firing pulses to the inverter. This system is simulated using MATLAB and results are obtained. Key words: Shunt Active Power Filter, harmonics, Synchronous Reference Frame Algorithm, Hysteresis current control, Reference current. I. INTRODUCTION The wide use of power electronics based controller technology for non linear loads, industrial machines and automation devices in industries, in commercial and households appliances, have led to a significant increase in disturbances, which affect power quality in power systems. Therefore, it is necessary to develop and implement solutions to improve power quality in electrical power systems [-]. Conventionally passive L-C filters were employed to reduce harmonics and capacitors were used to improve the power factor of the loads. But passive filters have the demerits of fixed compensation, large size and resonance. The increased severity of harmonic pollution in power distribution network has attracted the attention to develop dynamic and adjustable solutions to the power quality problems giving rise to active filter []. Now days, shunt active power filters have appeared as an effective method to solve the problem of harmonics, with reactive power compensation. Active power filters are connected to phase AC transmission lines in order to eliminate voltage distortion and harmonic components. Shunt active power filter are used to eliminate the current harmonic components working as a source with only the harmonic components and power factor correction, so that only the fundamental component is supplied in the phase AC lines [4-7]. The Shunt Active Power Filter is connected in parallel with the line through a coupling inductor. Its main power circuit consists of a three phase three-leg current controlled voltage source inverter with a DC link capacitor. An active power filter operates by generating a compensating current with 80 degree phase opposition and injects it back to the line so as to cancel out the current harmonics introduced by the nonlinear load. This will thus suppress the harmonic content present in the line and make the current waveform sinusoidal. So the process comprises of detecting the harmonic component present in the line current, generating the reference current, producing the switching pulses for the power circuit, generating a compensating current and injecting it back to the line. [] 9

BUSINESS AND TECHNOLOGY (IJSSBT), Vol., No., June 05 ISSN (Print) 77 76 stationary frame (αβ-0) from the three-phase stationary frame (a-b-c), as per equation (). i 0 0 i a ib ic () Fig No. - phase shunt active power filter with SRF controller II. SYSTEM DESIGN A. Synchronous Reference Frame Algorithm Various control strategies has been developed for the determination of reference currents in shunt active power filters namely Instantaneous Reactive Power Theory (p-q theory), sliding mode control strategy, Unity Power Factor method, One Cycle Control, Fast Fourier Technique etc. Here, SRF theory is used to evaluate the three-phase reference currents (i ca *, i cb *, i cc *) by the active power used filters by targeting the source (i ca, i cb, i cc ) current Fig. shows the block diagram which explains three-phase SRF-theory, used for harmonic component extraction. Here in SRF theory Park transformation is used. Here two directand inverse parks transformation is used which allows the evaluation of specific harmonic component of the input signals and a low pass filtering stage LPF. Now, the two phase current quantities iα and of stationary αβ-axes are transformed into two-phase synchronous (or rotating) frame (d-q-axes) using equation (), where Cosθ and Sinθ represents the synchronous unit vectors which can be generated using phase-locked loop system (PLL). i d iq cos θ sin θ sin θ cos θ () The d-q currents thus obtained comprises of AC and DC parts. The fundamental component of current is represented by the fixed DC part and the AC part represents the harmonic component. This harmonic component can be easily extracted using a high pass filter (HPF), as implemented in Fig. The d-axis current is a combination of active fundamental current (id dc) and the load harmonic current (ih). The fundamental component of current rotates in synchronism with the rotating frame and thus can be considered as dc. By filtering id, the current is obtained, which represents the fundamental component of the load current in the synchronous frame. Thus, the AC component id h can be obtained by subtracting id dc part from the total d-axis current (id), which leaves behind the harmonic component present in the load current. In the rotating frame the q-axis current (iq) represents the sum of the fundamental reactive load currents and part of the load harmonic currents. So the q-axis current can be totally used to calculate the reference compensation currents. Now inverse transformation is performed to transform the currents from two phase synchronous frame d-q into two-phase stationary frame α-β as per equation (). cos θ sin θ sin θ cos θ i d i q () Fig No. Block diagram of SRF based algorithm In this method, the source currents (ia, ib, ic) are first detected and transformed into two-phase Finally the current from two phase stationary frame αβ0 is transformed back into three-phase stationary frame abc as per equation (4) and the compensation reference currents ica*, icb* and icc* are obtained. 94

BUSINESS AND TECHNOLOGY (IJSSBT), Vol., No., June 05 ISSN (Print) 77 76 i ca i cb i cc T abc i 0 (4) Where, T abc 0 B. Hysterisis Band Current Control (5) The hysteresis band current control (HBCC) technique is used for pulse generation in current controlled VSIs. The control method offers good stability, gives a very fast response, provides good accuracy and has got a simple operation. The HBCC technique employed in an active power filter for the control of line current is shown in Fig.. It consists of a hysteresis band surrounding the generated error current. The current error is obtained by subtracting the actual filter current from the reference current. The reference current used here is obtained by the SRF method as discussed earlier which is represented as Iabc*. The actual filter current is represented as I f abc. The error signal is then fed to the relay with the desired hysteresis band to obtain the switching pulses for the inverter. Fig No. 4 Simulation diagram of hysteresis current control The switching signals thus generated are fed to the power circuit which comprises of a three phase three leg VSI with a DC link capacitor across it. Based on these switching signals the inverter generates compensating current in phase opposition to the line current. The compensating current is injected back into the power line at the PCC and thus suppressing the current harmonics present in the line. The overall simulation block diagram is shown in Fig 5. Fig No.5 Overall simulation diagram. Fig No.. Hysteresis Band Current Controller The operation of APF depends on the sequence of pulse generated by the controller. Figure 4 shows the simulation diagram of the hysteresis current controller. A band is set above and below the generated error signal. Whenever this signal crosses the upper band, the output voltage changes so as to decrease the input current and whenever the signal crosses the lower band, the output voltage changes to increase the input current. Accordingly switching signals are generated. II. SIMULATION RESULTS AND DISCUSSION In this paper simiulation of SRF algorithm using park transfomation hass been done which is shown in fig 5.from this the referencee signal Iabc* is produceed from SRF algorithm which is shown in fig 6. Then this refrence current is compared with actual current signal from which error signal is developed shown in fig 7. which is fed to the hystersis band control harmonic current. This developed the pulsee signal for VSI shown in fig 8. 95

BUSINESS AND TECHNOLOGY (IJSSBT), Vol., No., June 05 ISSN (Print) 77 76 Fig No.6 Refrence current from SRF Algorithm Fig No.9 VSI output III. CONCLUSIONS This paper describes compensation process for the line current harmonics generated due to nonlinear loads in the system. Using Synchronous Reference Frame Algorithm three phase reference current is generated, this is compared with the actual filter current and resultant signal is given to the HBCC, it provides control signal to three phase voltage source inverter. HBCC technique used for the switching pulse generation is found more effective and gives fast response. IV. REFERENCES Fig No.7 Error Signal Fig No.8 Pulse signal for VSI [] Rejil C, Anzari M and Arun Kumar, Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory [] Consalva J. Msigwa, Beda J. Kundy and Bakari M.M. Mwinyiwiwa, Control Algorithm for Shunt Active Power Filter using Synchronous Reference Frame Theory World Academy of Science, Engineering and Technology 58 009 [] Alberto Pigazo, A Recursive Park Transformation to Improve the Performance of Synchronous Reference Frame Controllers in Shunt Active Power Filters IEEE Transactions On Power Electronics, Vol. 4, No. 9, September 009. [4] Mohammad Monfared, A New Synchronous Reference Frame-Based Method for Single-Phase Shunt Active Power Filters Journal of Power Electronics, Vol., No. 4, July 0. [5] Abdelmadjid Chaoui, On design of Shunt Active Filter for Improving Power quality 978-444-666-0/08@ 008 IEEE. [6] Diyun WU, Design and Performance of a Shunt Active Power Filter for Threephase Four-wire System 009 rd International Conference on Power Electronics Systems and Applications. [7] Dr. Vitthal S Bandal, Performance Analysis of shunt Active Power Filter using Sliding Mode Control Strategies IEEE transaction on Variable Structure System VSS January -4, Mumbai 0. [8] Deepathi Joseph, P-Q Theory for Shunt Active Filter using Ramp Comparator IEEE transaction on International conference on Power, Energy and Control. 0. [9] Diyun WU, Design and Performance of a Shunt 96

BUSINESS AND TECHNOLOGY (IJSSBT), Vol., No., June 05 ISSN (Print) 77 76 Active Power Filter for Three phase four wire systems International conference on power Electronics System and Application.009. [0] L. Gyugyi and E. C. Strycula, "Active AC power filters", IEEE IIAS Annual Meeting, 976, p. 59. [] H. Akagi, Y. Kanazawa, A. Nabae, Instantaneous Reactive Power Compensators comprising Switching Devices without Energy Storage Components, IEEE Transactions on Industry Applications, Vol. IA-0, No., May/June 984. [] H. Akagi, Y. Tsukamato, A. Nabae, Analysis and Design of Active Power Filter using Quad-series Voltage Source PWM Converters, IEEE Transactions on Industry Applications, Vol. 6, No., January/February 990. [] B. Singh, Kamal Al-Haddad, A. Chandra, A Review of Active Filters for Power Quality Improvement, IEEE Transactions on Industrial Electronics, Vol. 46, No. 5, October 999. [4] Leszek S. Czarnecki, Instantaneous Reactive power p-q theory and Power properties of -phase system, IEEE Transactions on Power Delivery, Vol., No., pp.6-67, Jan. 006. [5] F. Z. Peng, G. W. Ott Jr., D. J. Adams, Harmonic and reactive power compensation based on the generalized instantaneous reactive power theory for three-phase four-wire systems IEEE Trans. Power Electron., Vol., No. 5, pp. 74-8, Nov. 998. 97