Radio-frequency scanning tunneling microscopy

Similar documents
A Project Report Submitted to the Faculty of the Graduate School of the University of Minnesota By

Scanning Tunneling Microscopy

Theory and Applications of Frequency Domain Laser Ultrasonics

SUPPLEMENTARY INFORMATION

Nd:YSO resonator array Transmission spectrum (a. u.) Supplementary Figure 1. An array of nano-beam resonators fabricated in Nd:YSO.

S1. Current-induced switching in the magnetic tunnel junction.

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

Exam Signal Detection and Noise

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Study of shear force as a distance regulation mechanism for scanning near-field optical microscopy

The superconducting microcalorimeters array for the X IFU instrument on board of Athena Luciano Gottardi

; A=4π(2m) 1/2 /h. exp (Fowler Nordheim Eq.) 2 const

Extreme Sensitivity in Photoacoustics by Using Optical Cantilever-type Microphone

Mechanical detection of magnetic resonance using nanowire cantilevers: opportunities and challenges

Introduction to Microeletromechanical Systems (MEMS) Lecture 12 Topics. MEMS Overview

A new capacitive read-out for EXPLORER and NAUTILUS

SUPPLEMENTARY INFORMATION

Self-navigation of STM tip toward a micron sized sample

SUPPLEMENTARY INFORMATION

Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors

Micro- & Nano-technologies pour applications hyperfréquence à Thales Research &Technology Afshin Ziaei, Sébastien Demoustier, Eric Minoux

Supporting Information. Atomic-scale Spectroscopy of Gated Monolayer MoS 2

Esaki diodes in van der Waals heterojunctions with broken-gap energy band alignment

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

Interface Trap States in Organic Photodiodes. Supplementary Information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION

Non-reciprocal phase shift induced by an effective magnetic flux for light

High-Speed Optical Modulators and Photonic Sideband Management

MICROMACHINED INTERFEROMETER FOR MEMS METROLOGY

Akiyama-Probe (A-Probe) technical guide This technical guide presents: how to make a proper setup for operation of Akiyama-Probe.

Edge-mode superconductivity in a two-dimensional topological insulator

A proposal for the measurement of the non-stationary Casimir effect

A gravitational wave is a differential strain in spacetime. Equivalently, it is a differential tidal force that can be sensed by multiple test masses.

A scanning tunneling microscopy based potentiometry technique and its application to the local sensing of the spin Hall effect

XYZ Stage. Surface Profile Image. Generator. Servo System. Driving Signal. Scanning Data. Contact Signal. Probe. Workpiece.

Realization of H.O.: Lumped Element Resonator

MEMS-based Micro Coriolis mass flow sensor

Atomic-layer deposition of ultrathin gate dielectrics and Si new functional devices

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Overview. Tasks: 1.1. Realization of a direct coherent microwave-to-optical link

arxiv: v1 [cond-mat.supr-con] 21 Oct 2011

SUPPLEMENTARY INFORMATION

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Supplementary Information. The origin of discrete current fluctuations in a fresh single molecule junction

Magnetic and Electromagnetic Microsystems. 4. Example: magnetic read/write head

Optomechanical coupling between a multilayer graphene mechanical resonator and a superconducting microwave cavity

PSD Characteristics. Position Sensing Detectors

Supplementary information for Stretchable photonic crystal cavity with

Cavity QED with quantum dots in semiconductor microcavities

MEMS Reference Oscillators. EECS 242B Fall 2014 Prof. Ali M. Niknejad

Supporting Information

Interferometer signal detection system for the VIRGO experiment. VIRGO collaboration

Nano-structured superconducting single-photon detector

SUPPLEMENTARY INFORMATION

Dynamics of Charge Carriers in Silicon Nanowire Photoconductors Revealed by Photo Hall. Effect Measurements. (Supporting Information)

Akiyama-Probe (A-Probe) guide

Ian JasperAgulo 1,LeonidKuzmin 1,MichaelFominsky 1,2 and Michael Tarasov 1,2

ELECTRICAL PROPERTIES OF POROUS SILICON PREPARED BY PHOTOCHEMICAL ETCHING ABSTRACT

PACS Nos v, Fc, Yd, Fs

Scanning Tunneling Microscopy

MEMS BASED QUARTZ OSCILLATORS and FILTERS for on-chip INTEGRATION

An impedance-based integrated biosensor for suspended DNA characterisation

NOISE IN MEMS PIEZORESISTIVE CANTILEVER

Forward bias operation of irradiated silicon detectors A.Chilingarov Lancaster University, UK

Fast Electron Temperature Diagnostic Based on Langmuir Probe Current Harmonic Detection on D-IIID

in hbn encapsulated graphene devices

MEMS BASED QUARTZ OSCILLATORS and FILTERS for on-chip INTEGRATION

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

E3 237 Integrated Circuits for Wireless Communication

Department of Electrical Engineering IIT Madras

Avalanche Photodiode. Instructor: Prof. Dietmar Knipp Presentation by Peter Egyinam. 4/19/2005 Photonics and Optical communicaton

PROBLEM SET #7. EEC247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2015 C. Nguyen. Issued: Monday, April 27, 2015

Tip-induced band bending and its effect on local barrier height measurement studied by light-modulated scanning tunneling spectroscopy

Fabrication of High-Speed Resonant Cavity Enhanced Schottky Photodiodes

Sub 300 nm Wavelength III-Nitride Tunnel-Injected Ultraviolet LEDs

techniques, and gold metalization in the fabrication of this device.

Two-stage SQUID systems and transducers development for MiniGRAIL

BRIDGE VOLTAGE SOURCE

Up to 6 GHz Low Noise Silicon Bipolar Transistor Chip. Technical Data AT-41400

III-Nitride microwave switches Grigory Simin

The effect of rod orientation on electrical anisotropy in silver nanowire networks for ultra-transparent electrodes

A 200 h two-stage dc SQUID amplifier for resonant gravitational wave detectors

Long-distance propagation of short-wavelength spin waves. Liu et al.

NON-CONTACT VOLTAGE AND ELECTRIC FIELD MEASUREMENT USING THE ELECTRIC POTENTIAL SENSOR

Low frequency noise measurements in direct detection radiometers

Supplementary Materials for

SUPPLEMENTARY INFORMATION

Spectral Phase Modulation and chirped pulse amplification in High Gain Harmonic Generation

Shot-noise suppression effects in InGaAs planar diodes at room temperature

Supplementary Materials for

RF Physics: Status and Plans

Quantum States of Light and Giants

Lecture 10: Accelerometers (Part I)

Advanced Nanoscale Metrology with AFM

A Narrow-Band Tunable Diode Laser System with Grating Feedback

photolithographic techniques (1). Molybdenum electrodes (50 nm thick) are deposited by

Piezoelectric Sensors and Actuators

Transcription:

doi: 10.1038/nature06238 SUPPLEMENARY INFORMAION Radio-frequency scanning tunneling microscopy U. Kemiktarak 1,. Ndukum 2, K.C. Schwab 2, K.L. Ekinci 3 1 Department of Physics, Boston University, Boston, MA 02215 USA 2 Department of Physics, Cornell University, Ithaca, NY 14853 USA 3 Department of Aerospace and Mechanical Engineering, Boston University, Boston, MA 02215, USA 1-Shot Noise hermometry and hermal Imaging In this section, we discuss the possibility of using the RF-SM as a local thermometer for samples that have local temperature variations on the surface. Using shot noise thermometry, one can measure the temperature of a tunnel junction very accurately in a short period of time. But there is a question that remains unanswered: What is the temperature that one would measure through shot noise thermometry, if the temperature of the SM tip is different from that of the sample? his is the situation one would encounter when imaging a sample with spatial thermal profile, such as a high density integrated circuit. Here, we provide a simple analysis towards resolving this question. he current noise through the tip ()-sample (S) tunnel junction is given by 1 2 SI( V) = f( E) ( 1 fs( E) ) fs( E) ( 1 f( E) ) de R +, (S1) where f ( E ) and fs ( E ) are the Fermi-Dirac distributions for the tip and the sample. Here, temperature dependence is through the Fermi-Dirac distribution function, [ µ ] f ( E) = 1/ 1+ exp( E ) / kb. µ is the chemical potential; in a biased tip-sample junction µ S µ ev, where V is the bias voltage. Eq. (S1) can be evaluated in a www.nature.com/nature 1

doi: 10.1038/nature06238 SUPPLEMENARY INFORMAION 2 S >300 K ev =300 K Fit emperature eff (K) 480 440 400 360 320 S I R/2 (ev/hz) 0.2 0.1 300 K 450 K 600 K -0.2-0.1 0.0 0.1 0.2 Bias (V) =300 K 280 300 350 400 450 500 550 600 Surface emperature S (K) (a) (b) Supplementary Figure S1. (a) Illustration of the electronic density of states for the tip and sample for the problem described in text. (b) Effective temperature from fits as a function of sample surface temperature when the tip is kept is at 300 K. he inset shows the change in power spectral density of current noise at several different sample temperatures with = 300 K. Higher sample temperatures create excess noise at low bias. At high bias, all curves converge to S = 2eI as expected. When these curves are fit to coth( ev / 2 k ), I as if there was no temperature difference between the tip and the sample, one gets the effective temperature eff. Note that eff ( + S )/2. B straightforward manner to obtain S ( V ) = 2eI coth( ev / 2 k ) for a tunnel junction with both terminals at the same temperature. I B For the case where there is a local temperature variation on the sample, we naively apply Eq. (S1) with two temperatures, i.e., = (1 + θ ) as shown in the illustration in Supplementary Fig. S1(a). Here, θ is a variable that corresponds to the fractional temperature difference. Our calculation steps can be outlined as follows: i) We first set θ (0 θ 1) with = 300 K; ii) we calculate SR / 2 as a function of bias S I www.nature.com/nature 2

doi: 10.1038/nature06238 SUPPLEMENARY INFORMAION 3 through Eq. (S1); iii) we extract the temperature from the emerging curves by fitting to ev coth( ev / 2 kb eff). he extracted effective temperature eff is the temperature one would measure from a local hot spot on the surface. he inset of Supplementary Fig. S1(b) shows S I as S is varied from 300 K to 600 K, while the tip temperature is kept constant at = 300 K. Supplementary Figure S1(b) (main) shows the extracted fit temperature eff from this measurement. Notice that the extracted temperature from the fit is approximately the mean temperature: ( + )/2. eff S he averaging time for a 100 100 thermal image is obtained as follows: We take the background temperature as the sum of the ambient temperature, 300 K, and the noise temperature of our amplifier, 70 K: bg 370 K. he measurement bandwidth is the bandwidth of the tank circuit and B 10 MHz (half width at half maximum) as shown in Fig. 2(a). he averaging time to achieve 1 K temperature resolution in noise power measurement can be estimated 2 using / = 1/ Bτ as ~10 ms. In order to determine bg background noise and gain-bandwidth product of the system, one needs to measure the noise power as a function of bias for ev 2 B >> k. Since the noise spectral density, SI = 2eI, does not depend on temperature in this regime, one only needs to do this measurement once. hen measuring the noise power at a low bias value, where the temperature dependence is dominant, at every point on the surface would be enough to obtain a thermal image. hus, an image of 100 100 points would require ~100 seconds. 2-Displacement Sensitivity and unneling Decay Constant: In this section, we supply the detailed steps for obtaining an estimate for the displacement sensitivity of the RF-SM based upon the data in Fig. 3(c) and Fig. 1(b). www.nature.com/nature 3

doi: 10.1038/nature06238 SUPPLEMENARY INFORMAION 4 here are several elements in this calculation: i) the sample motion amplitude is estimated; ii) tunnel junction decay constant κ is determined; iii) the displacement sensitivity is extracted. o estimate the displacement of the Au surface in Fig. 3(c), we first determine how much the piezoelectric actuator disk, which the Au sample is attached to, moves. Using a path-stabilized Michelson interferometer, we obtain the linear responsivity of the actuator as R= 0.33 nm/v at 1 MHz. In the data presented in Fig. 3(c), the V piezoelectric actuator is driven at f M 1 MHz at various amplitudes. he displacement of the Au sample shaken by the piezo actuator is measured by launching a radio-frequency signal (carrier) of amplitude V c at frequency f LC towards the tank circuit, and by measuring the reflected signal amplitude V r. Before amplification, power spectral density of the reflected signal in a single sideband is V Γ c SV ( f ± ) ( ) r LC fm Sz fm. (S2) 2 R Here, S ( f ) represents the spectral density of displacement noise, or the available z M displacement sensitivity, at frequency f M. Note that Fig. 3(c) in the main text shows the signal amplitude, V ( f + f ), in a 1 Hz bandwidth in the sideband divided by the r LC M carrier amplitude, V ( f ). hus, from Eq. (S2), slope of each line in Fig. 3(c) gives c LC Γ/ at the particular R, at which the measurement is made. R www.nature.com/nature 4

doi: 10.1038/nature06238 SUPPLEMENARY INFORMAION 5 R Γ/ (m -1 ) Γ / R (Ω -1 ) κ (Å -1 ) 1 MΩ 5.76 ± 0.89 10 8 3.9 10-8 0.74 ± 0.11 2 MΩ 3.88 ± 0.35 10 8 1.0 10-8 0.97 ± 0.088 4 MΩ 2.29 ± 0.25 10 8 0.26 10-8 1.1 ± 0.12 Supplementary able S1. Reflection properties and tunneling decay constants for different R values. Γ / z values in the first column are the slopes of the lines in Fig 3(c). In the second R column, Γ / values are extracted from the slope of Fig. 1(b) at the specific R values. κ R R is calculated using first two columns and the corresponding R values. If an exponential tunnel junction resistance, R 2 z e κ, is assumed, 3 determining the decay constant, 1 κ = 2R R, requires the knowledge of Γ/ R as well as R R Γ/. R is given by R Γ/ = Γ/ R R R. In the experiments, Γ/ R R can be determined from the slope of the curve in Fig. 1(b) at the R value of interest. On the other hand, Γ/ can be determined from the slope of the lines in Fig. 3(c). he R values thus obtained from the experiments are listed in Supplementary able S1. Independent of the measurements, κ can be estimated from κ = 2 m φ / where φ is the work function 3 if one assumes vacuum tunneling at small bias voltage. For Au, φ 5.1 ev and κ 1.16 Å -1, in agreement with the experiments. Finally, we turn to the displacement sensitivity of the RF-SM. Our measurement system has a noise floor of -172.4 dbm/hz. his is equivalent to a noise www.nature.com/nature 5

doi: 10.1038/nature06238 SUPPLEMENARY INFORMAION 6 voltage of ~5.4 10-10 V/ Hz at the input of the amplifiers. he carrier power used in our measurements is -65 dbm or 130 µv. For an experimental value of R 1 MΩ, we obtained Γ R = 1MΩ 5.76 10 8 m -1, from Fig. 3(c). hus, Eq. (S2) gives minimum detectable displacement of S z 15 fm/ Hz. If the cryogenic pre-amplifier is cooled to 4 K, the voltage noise floor goes down to ~1 10-10 V/ Hz, resulting in a displacement sensitivity of S z 3 fm/ Hz. Note that the sensitivity is estimated for a small motion amplitude such that Γ/ z stays roughly constant, i.e., 3-Micromechancial Membrane Properties: z < κ 1. he silicon nitride membranes used in this study are batch fabricated using standard microlithography methods. he membrane has dimensions w l t 65 µm 70 µm 40 nm (silicon nitride) and is patterned with alignment marks and coated with a 25-nm thick Au film. Scanning electron microscope (SEM) and SM images of the membrane are shown in Supplementary Fig. S2 (a) and (b). In determining the eigenfrequencies, we assume that the membrane is perfectly flexible and very thin. We further assume that the membrane is uniformly stretched in all directions in such a way that the out-of-plane displacement of the membrane does not change its tension. In terms of the properties of the membrane, namely, its tension S, mass density ρ, thickness t, length l and width w, its resonance frequencies can be obtained as f mn ωmn 1 S m n = = + 2π 2 ρt w l 2 2 2 2. www.nature.com/nature 6

doi: 10.1038/nature06238 SUPPLEMENARY INFORMAION 7 (a) (b) Supplementary Figure S2. (a) Scanning electron microscope (SEM) image of the membrane used in the measurement of Fig. 3(a). We put Au markers on the chip in order to direct the SM tip towards membrane. he whole chip is covered with a 25-nm-thick Au film. (b) An SM image of a portion of the membrane. he markers are clearly visible. he membrane area is also recognizable as the darker region in the SM image. www.nature.com/nature 7

doi: 10.1038/nature06238 SUPPLEMENARY INFORMAION 8 1. Martin, h., Landauer, R. Wave-packet approach to noise in multichannel mesoscopic systems. Phys. Rev. B, 45, 1742 (1992). 2. Dicke, R. H. he measurement of thermal radiation at microwave frequencies. Rev. Sci. Instrum. 17, 268 (1946). 3. Binnig, G., Rohrer, H., Gerber, Ch., and Weibel, E. unneling through a controllable vacuum gap. Appl. Phys. Lett. 40, 178 (1982). www.nature.com/nature 8