Pinnacle Technical. Bench and Shelf Trunking. cable management perimeter and distribution. Features.

Similar documents
Norwich Technical. Trunking PERIMETER AND DISTRIBUTION. Description CABLE MANAGEMENT. Colour: White only. Material: PVCu. mkelectric.co.

Ega Industrial Technical

Powerlink Plus Technical

Prestige 2Com Technical

PINNACLE RANGE INTRODUCTION PERIMETER AND DISTRIBUTION FEATURES & BENEFITS CABLE MANAGEMENT

150mm to 200mm. With box in comp 2 2 = 1535mm² total area 2 = 691mm² 45% space factor. C. & C. Marshall Ltd.

REHAU PROFILA BENCH TRUNKING INSTALLATION GUIDELINES. Building Solutions Automotive Industry

PRESTIGE 3D COMPACT RANGE INTRODUCTION PERIMETER AND DISTRIBUTION FEATURES & BENEFITS CABLE MANAGEMENT

Raised Floor system LIMOGES Cedex. Phone : Fax :

Cablelink Plus Flush Technical

Marshall Tufflex. Cable Management. Steel Trunking Systems

Flush Floor system LIMOGES Cedex. Phone : Fax :

compile system INSTALLATION GUIDE Updated January 2019

Premier. cable management perimeter and distribution

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

Cable Management Range Brochures

Trunking Guide. Colour List... W White M Magnolia B Black. shape & size (wxh) colours available

PRESTIGE 3D ANTIBAC BLUE

DLP-S Trunking LIMOGES Cedex. Phone : Fax :

Warwick PVC Perimeter Trunking Systems

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

INOVO 2-LITE SLIDING PATIO DOOR

Cable Cover Guide. Color List... W White B Black P Premium Wood (stainable Floor Trim only) shape & size (wxh) colors available

Risk Assessment & Safe Working Practice

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

Vanity Installation Instructions

DLPlus. Dado and Skirting trunking LIMOGES Cedex. Phone : Fax :

Answer Power Beam and Boundary Screen

CleanBench Laboratory Tables

DUALCASE VERSATILE ALUMINIUM SIGN SYSTEM

Assembly Instructions Nevins Phone Booth

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER.

LF Series Assembly Instructions

Dura-Lock Roof System

Installation Operation Care

** Do Not Contact the Store ** For Assistance, including missing or broken parts, Call Customer Service at:

INSTALLATION INSTRUCTIONS DANUBE ACRYLIC NEO ANGLE

OXYGEN INSTALLATION. Revision date

Revised

Assembly Instructions

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

Laminate Cabinet Installation Instructions

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

Desk/Wall-Mount Rack

Interactive Monitor Arm

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

WPS crew Doors Installation instructions

IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT

High Density Sports Storage

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

MobileTrak5 Installation Instructions

SunTrackerTwo Preparation

IMPORTANT INSTALLATION GUIDE VALENCIA ANGLE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Angled Side Flush with Panel Face

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE

Trunking. light grey in U23X. Industrial Catalogue

OPERATOR'S MANUAL RULES FOR SAFE OPERATION

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

AIR MASTER SYSTEMS INSTALLATION GUIDE TABLE OF CONTENTS

Figure A. Figure B. Figure C. Figure D

Compile Installation Manual

Technical guide. The technical guide provides all the additional information you need on our cable management products.

Ultra-efficient installation solutions

Roof Rack Installation Instructions

FABA. Installation Instructions. Conductor Bar System. Publication #FABA-03 3/1/04 Part Number: Copyright 2004 Electromotive Systems

Ega Mini Trunking, Communication & Red Alert Trunking

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Footprint Mobile Assembly Instructions

Assembly Instructions Nevins Phone Booth

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

Due to possible damage in shipping, the vertical stop assembly has been removed from this machine.

Cable Management Solutions with DLP TM

Installing the Profile Privacy Panel. Assemble top mounting bracket. Prerequisites. Tools

Installation Instructions For TruLine 1.6A 24VDC

Liniar Window. installation guide

Parts list continues on Page 2 HOUSE PARTS PACKED IN HOUSE BOX PARTS IN SMALL PLASTIC BAG (HARDWARE) POST PARTS PACKED IN THIS BOX (LARGE PLASTIC BAG)

Vanity Installation Instructions

ASSEMBLY INSTRUCTIONS FOR SL500A AND SL500AL

TOOLS REQUIRED: HARDWARE INCLUDED: 13MM FLAT WRENCH FOR LEVELING THE STRUCTURE RATCHET WITH 5MM HEX BIT FOR CORNER SCREWS ON TOP TRAVERSE BEAMS

Tradewinds Amplify Display System Instructions

XL JOINERY LTD LA PORTE VISTA MODULAR 3 ASSEMBLY INSTRUCTIONS

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

Geiger Rhythm. Right ON SITE. Installation Principles

A range of cost-effective PVC-U cable containment for general wiring installations. PVC-U TRUNKING

Linear Hook- on Worksurfaces

Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS. Web. acrylicdesign.ie .

SURFACE CLIP MOUNT. 1 Insert lens into channel, measure, and cut to length. Remove lens cover from channel. surface. Attach lens cover and end caps

Lightline Movable Wall Installation Manual. Preliminary Draft #

INSTALLATION INSTRUCTIONS

Hawko LED Flex & Accessories Installation Instructions

Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY.

INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES

Installation manual. For setting in concrete/on base plates - Panel height 1830

Oxford Stalls Installation Instructions

Hawko Zhaga Systems Installation Instructions

Hinge Door + Inline Panel + Return Panel

Track Rack. * Track Racks are not lockable

INSTALLATION INSTRUCTIONS LARGE FLAT PANEL IN WALL ENCLOSURE Model: PAC-500

Transcription:

604 Pinnacle Technical cable management perimeter and distribution www.mkelectric.co.uk Bench and Shelf Trunking Features l Available in a single or double configuration l May be fitted either direct to the work surface or inverted above the working area l Cable segregation is provided by two separate compartments with the facility to further subdivide the main compartment by means of a clip-in cable divider l Single profiles may be converted to a back to back double assembly. A onepiece centre lid and double end caps complete the coupling l Prefabricated internal and external corners l Coupler sets for greater strength and protection l Bench units are also available to match the system l All extrusions manufactured from 90% recycled material* Description Pinnacle is an angular bench trunking system ideally suited for distributing LV electrical and communication services in laboratories, schools and workshops and other applications where the service contacts are mounted on or above desks and benches. Technical specification Materials PVCu materials used in the manufacture of MK products are self extinguishing non-flame propagating in accordance with BS 4678 Part 4. Extrusion material has been tested by a UKAS accredited laboratory in accordance with the requirements of BS476: part 7 and has achieved a Class 1Y. Moulding material has been tested by a UKAS accredited laboratory and conforms with IEC 695--1 at a severity of 650 C IEE Wiring Regulations Designed and manufactured to comply in all respects with BS 7671: 008 (IEE wiring regulations 17th Edition: 008) Quality Assurance The system is manufactured to BS EN ISO 9001 Pinnacle trunking is available in a choice of colours, White and Special. The Special offers a choice of over 180 RAL paint colours. * Based on 008 consumption For a full range of corresponding products, see pages 344-350 in the product selector.

Pinnacle Technical 605 technical hotline +44 (0)168 56370 perimeter and distribution cable management Bench and Shelf Trunking Dimensions (mm) 90 105 180 105 1 90 105 1 1 1 Version 1 PTS PINNACLE CABLE CAPACITY Version PTS Version 3 PTD Type of Size Cable Compartment 1 Compartment 1 Compartment 1 Compartment 1 Conductor Factor with 5mm with 35mm Power Cables backbox Full Term CSA 100%Fill (mm ) backbox 4510 499 1857 460 Term at 45% Fill (mm ) 09 114 835 07 Number of Cables at 45% Fill PVC Stranded 1.5mm 8.6 35 130 97 4 Data Cables.5mm 1.6 161 89 66 16 4mm 16.6 1 67 50 1 6mm 1. 95 53 39 9 Number of Cables at 45% Fill (a) and Full Capacity (b) a b a b a b a b Cat5E UTP 5.5mm dia. 30. 67 149 37 8 7 61 6 15 Cat5E STP 6.0mm dia. 36.0 56 15 31 69 3 51 5 1 Cat6 UTP 6.5mm dia. 4. 48 106 6 59 19 44 4 10 Cat6 STP 7.0mm dia. 49.0 41 9 51 17 37 4 9 PTS3WHI / PTS3COL External Corner PECLWHI 13 End Caps PECSWHI / PECSCOL 0 Coupler Set PCWHI / PCCOL Internal Corner PICLWHI

606 Pinnacle Technical cable management perimeter and distribution www.mkelectric.co.uk Installation guide General notes Prior to installation strike a line of trunking using a plumb and chalk line for vertical, and spirit levels for horizontal runs. Incoming Supply Cables 1 Establish location of incoming cable supplies. Entry into the trunking can be from the back, base or end caps and is achieved by drilling up to a 5mm hole using the drill base centres in the trunking and inserting a conduit gland. Holes of 0mm can be drilled into the end caps for access to the large compartment using one of a series of moulded drill centres. Fixing 3 Trunking requires fixing at staggered centres, 50mm maximum along the length with the first and last fixing not more than 50mm from the end of each length. Drill trunking with 6mm holes using drill guides and fix with pan or round head screws and washers (Note: Tighten screws 4 5 6 7 firmly and back off slightly to allow for movement). For double trunking installation fix both bases this way. Couplers - Always use a trunking coupler and cover at the junction between each length and at corners to maintain IP4X Classification. To fix push the coupler carrier onto the end of the free trunking length. Slide up to fixed trunking and push home. Internal and External Corners Remove covers. Push a coupler onto each end and assemble to trunking. Position trunking and corner. Check that the internal corner base fits snugly into the corner. Fix trunking base as previously described. End caps Having located the length of trunking and cut if required push fit the end cap firmly onto the trunking ensuring that it is butted up tight. Note: where greater retention is required use MK adhesive EW PLUS to bond the end cap to the trunking base only. Avoid adhesive contact with covers. Cable Retainer without central divider installed. 6 50mm 1 4 50mm 3 50mm 5

Pinnacle Technical 607 technical hotline +44 (0)168 56370 perimeter and distribution cable management 8 The divider and cable retainer interlock should be installed together whenever the divider is used. Divider To achieve the correct fit a portion of the divider needs to be removed prior to fitting. The divider is formed with a series of depth gauge lines to assist when cutting. These also serve to determine the correct cut out when using outlet boxes. Having prepared the cut outs as required push fit the divider into the preformed groove in the internal corner of the trunking. Cable Retainer Incorporate as many cable retainers as required to provide restraint and support for cables. This is particularly critical when trunking is mounted overhead in a downward facing position. These should be no more than 600mm centres maximum and within 100mm of an end or corner. The cable retainer is supplied with a series of shallow slots. Use the centre slot to engage the outer cut edge of the cable divider. The legs of the cable retainer engage behind the projections within the large compartment. 9 10 Determine location of outlets and select correct depth box. Remove knockouts to suit cable entry. Push fit brass terminal (K3716) if required into the aperture in the base of the box. Drill the large compartment walls using the drill guide groove to allow cables to feed when supplying from small compartment. Press and clip box into the trunking body engaging the rear projections. Note: Where dividers are installed they need to be reduced to accommodate the selected depth box. Adjacent boxes should not be more than 5mm apart. 5 9 8 7 10

608 Pinnacle Technical cable management perimeter and distribution www.mkelectric.co.uk Covers 11 Slide cover under end cap where required before locating correctly in position. Pushing firmly snap into place. The top cover in the double (back to back) trunking locks the two trunking bodies together. 1 13 Internal and external corner covers should be installed with couplers. Leave a gap of 13mm at the junction between corner cover and the trunking covers to allow fitting of coupler covers. Correctly position and snap firmly into place. At joint couplers, overlap the coupler carrier flanges with the lids. The gap left between the covers will allow for the fitting of joint covers. Having satisfactorily installed all trunking covers firmly push fit the coupler covers into place overlapping all the cover completely. 14 15 Removal Main compartment cover removal is readily achieved if a wiring accessory or coupler is present. Remove the accessory and exerting pressure to the underside of the cover with the head of a flat screwdriver to initiate disengagement, peel the cover back. When no accessory is available remove a moulded coupler cover by placing the head of a small flat screwdriver at the junction with the trunking cover and lever outwards slowly disengaging the cover moulding. When levering off coupler covers protect trunking faces from damage. When the coupler cover is removed initiate clip disengagement of trunking covers and peel back. 15 14 1 11 13 1 13 15

Pinnacle Pillar Technical 609 technical hotline +44 (0)168 56370 perimeter and distribution cable management Pinnacle Pillar Standards and approvals Conforms to the heavy duty requirement of BS 4678 Part 4 and the IP4X classification of EN 6059 CE compliant meeting the LV directive Technical specification Materials PVCu materials used in the manufacture of MK products are self extinguishing non-flame propagating in accordance with BS 4678 Part 4. Extrusion material has been tested by a UKAS accredited laboratory in accordance with the requirements of BS476: part 7 and has achieved a Class 1Y. Moulding material has been tested by a UKAS accredited laboratory and conforms with IEC 695--1 at a severity of 650 C IEE Wiring Regulations Designed and manufactured to comply in all respects with BS 7671: 008 (IEE wiring regulations 17th Edition: 008) Quality Assurance The system is manufactured to BS EN ISO 9001 Description Pinnacle Pillars are versatile, vertical multi-compartment systems providing a means to supply LV power, data and telecom services from ceiling or floor voids to specific perimeter locations. Installation This unit cannot be free standing and requires to be fully supported to an adequate wall or structure for its entire length. See Installation Guide 41973PL for details For a full range of corresponding products, see page 350 in the product selector.