Residual Current Monitoring Unit RCMU101SN-4P16C

Similar documents
Residual Current Monitoring Unit RCMU101SN-4P16

Current Transducer CTSR 1-P = 1A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

= 1000 V. Voltage transducer DVC 1000-P V P N

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

High Performance Current Transducer ITL 900-T = A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

The four pin one (J1) makes possible to supply the board and access to the output voltage easily. It has the following pin-out:

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Voltage transducer DVL 50

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

V P N. Voltage transducer DVM 2000-B = 2000 V

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

Current Sensor : F02P***S05L

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

V P N. Voltage transducer DVM 4200 = 4200 V

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

V P N. Voltage transducer DVL 1000 = 1000 V

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

I Pr I P I OUT R L. Applications. Standards

= 600 V. Voltage transducer DVM 600 V PN

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

DS10000ULFS-10V/10kA

SPECIFICATION Item no.: T60404-N4646-X975

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

Fluxgate system / Voltage-output type F03P***S05 SERIES

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

SPECIFICATION Item no.: T60404-N4646-X764

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

CMS2005 MagnetoResistive Current Sensor (I PN

AC/DC-sensitive Differential Current Sensors (DI-Sensors)

CMS2050 MagnetoResistive Current Sensor (I PN

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

Linear Current Sensor with differential outputs

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

V1000-ISO ± 1000V PRECISION HIGH BANDWIDTH ISOLATED VOLTAGE TRANSDUCER

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

AUTOMOTIVE CURRENT SENSOR HC6H300-S

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

HCPL-7840 Isolation Amplifier

CDS4025 MagnetoResistive Current Sensor (I PN

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

CMS3050 Highly Dynamic MagnetoResistive Current Sensor (I PN

AC/DC sensitive residual current monitoring module RCMB121-

HCPL-7800 Isolation Amplifier

Differential Current Sensor acc. to the standard UL2231 Ed.2.0. Customer: Standard type Page 1 of 7. Electrical data Ratings min. typ. max.

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

SPECIFICATION Item no.: T60404-N4646-X651

SPST-NO SPDT DPST-NO DPDT

SPECIFICATION Item no.: T60404-N4646-X762

OPTICALLY ISOLATED ERROR AMPLIFIER FOD2711 DESCRIPTION FEATURES APPLICATIONS PIN DEFINITIONS 9/6/02

AC/DC sensitive residual current monitoring module RCMB121-

Transcription:

Magtron Residual Current Monitoring Unit(RCMU ) Update: 2017.3.22. V1.0.3 Features Self-check function Single Supply +5 V Positive output for ADC Printed circuit board mounting Characteristics Stable accuracy self stimulation Low hysteresis offset voltage Short response time Integration frequency filter Compact design Applications Appliance ground fault detection Solar inverter residual current Converter leakage current detection UPS and other power ground fault detection Electric vehicle charge station Single or 3 Phases differential current detection Select Part List Part Number IPN(mA) IPM(mA) IM(A) ±1020 ±1700 ±80 Standards EN50178 IEC60950-1 UL1741 VDE0126-1-1 GBT1726.5 / IEC61000-4-5 / UL1449 Overview An important safety function of these devices is monitor of the leakage current of the entire system from Power modules or inverter against earth. A defective system can become dangerous for people or cause fires. Before it comes so far, the inverter must be disconnect from the grid. The leakage current contains DC and AC components. Therefore an AC/DC-sensitive monitoring unit is necessary. The heart of the safety device is the Magtron RCMU, whose value is evaluated by the control system of the Power inverter. Generally protection devices with AC/DC-sensitive differential current sensors can be used everywhere, where flat or pulsating DC can develop, whose amount is permanently greater than zero. Instruction of installation in a Pollution Degree 2 environment is available on the table below(or equivalent statement).

Application circuit Functional block diagram Application circuit Note: C1 should be close to the current sensor s pin Component selection reference: Designator Description C1 TDK,X5R,10uF/16V,±10%,0603 Pin Definition No. Symbol Description 1 VO Signal output 2 CHK Product Self-Check input 3 GND Power GND 4 VCC Power supply 5 REF Reference voltage output 6~13 IP Primary Current Current direction Assembly Pin Relationship between IP and output voltage

Absolute Maximum Ratings Parameter Symbol Min Typ Max Unit Supply Voltage(not operating) VC 5.5 V Ambient operating temperature TA -40 85 Ambient storage temperature TA -45 105 High Voltage Characteristics Parameter Symbol Value Unit Rms voltage for AC insulation test, 50 Hz, 1 min Ud 4.5 kv Impulse withstand voltage 1.2/50 μs Uw 7 kv System working voltage (RMS) Vs <750 V Comparative Tracking Index (group I) CTI 600 V Clearance (See drawing in page 6) DCI TBD mm Creepage distance (See drawing in page 6) DCP TBD mm Application example - 300, CAT III,PD2 V Application example - 600, CAT III, PD2 V Other Characteristics Parameter Symbol Value Unit Wave soldering profile TWSP 260 Electrical data At Ta=25,Vc=5V, unless otherwise noted Parameter Symbol Min Typ Max Unit Comment Power Supply voltage Vc 4.9 5 5.1 V 2% Cureent consumption Ic 25 ma Primary differential cureent IPN ±1020 ma Measurement range IPM ±1700 ma Output static state voltage VOS 2.5 V @ IP=0A Output voltage VON(+) 3.7 V @ + IPN Output voltage VOM(+) 4.5 V @ + IPM Output voltage VON(-) 1.3 V @ - IPN Output voltage VOM(-) 0.5 V @ - IPM Output voltage Gain VG 0.117 V @100mA Electrical offset voltage VOE <25 mv Accuracy X 2 % @ IPN /25 Full temperature Accuracy XFT 4 % @ IPN/-40~85 Linearity error εl 1 % @ IPN Bandwidth BW 700 Hz @-3dB Check current ICK 170 ma 10% Output voltage (Check function) V(CK) VOS+0.2 V Check enable voltage VCE 3.3 Vc V Check disabled voltage VCD <0.2 V Reference Voltage VREF 2.475 2.5 2.525 V 1% Fault over current recovery limit IM 80 A

Application information Self-check Function Set the CHK pin to high status. RCMU will run in self-test mode,check the out pin,equivalent to the status Ip equal Ick, at this time the output has equival voltage, the detector is OK.Then sets CHK to low voltage Vcheck<0.2V.The RCMU starts to run in the residual current. Photovoltaic Inverter Residual Current From VDE0126-1-1,Inverters without a basic insulation (e.g. basic insulated transformer) between the grid and the photovoltaic-generator must have a fault current monitoring unit (RCMU)installed. The d.c. and a.c. component of the fault current depend on the construction of the inverter and on the d.c. voltage of the PV-generator.

PCB Footprint PCB Holes Secondary pins: ø1.1x2.2 Primary Pins: ø5.0x8.0 Top view Safety This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements inaccordance with the manufacturer s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected.

Dimensions Mechanical Characteristics ( Unit : mm, Tolerance in ±0.2)