INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Similar documents
Log Periodic Antenna

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

MODEL 3810/2 Line Impedance Stabilization Network

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Opus 21 s80 Integrated Amplifier Owner's Manual

Instruction Manual Model M Switch, DPDT, Manual Select

Advanced Test Equipment Rentals ATEC (2832)

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

Advanced Test Equipment Rentals ATEC (2832)

POWER LINE IMPEDANCE STABLIZATION NETWORK (LISN) MODEL PLISN-25/2. 5 khz 1 GHz

ELECTROSURGICAL UNIT ANALYZER

2015 RIGOL TECHNOLOGIES, INC.

COM-POWER OPERATION MANUAL ACS W

Instruction Manual Model Upconverter

Amplifier Series BASIC. Installation & Operations Manual

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Double-Ridged Waveguide Horn Antennas

INSTRUCTION MANUAL LKG

Model 1791 VHF Radio User's Manual

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

HTA125A/250A. Power Amplifiers. Installation & Use Manual

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Two Line V-Network GLN-5040A USER MANUAL GW INSTEK PART NO. 99 Washington Street Melrose, MA Phone Toll Free

Broadband Current Probe Series Operation Manual

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

Instruction Manual Model Upconverter

AV30MX-2 Operation Manual

CIRCUIT-TEST ELECTRONICS

MODEL W Power Amplifier

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

CBA 400M MHZ to 400 MHZ

V1.3. TBLC08 50mH AC-LISN TBLC08

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Guide. Digital AC/DC Clamp Meter Model 38394

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS

200Amp AC Clamp Meter + NCV Model MA250

Current Probes. User Manual

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

PI-10 Broadband Power Indicator

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

Broadband Current Probe Series Operation Manual

Coupling/Decoupling Networks (CDN)

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

SAS-562B Active Loop Antenna Operation Manual

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE

PULSE OXIMETRY SIMULATOR

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

BROADBAND LINEAR AMPLIFIER Model P150

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

INSTRUCTION MANUAL. March 11, 2003, Revision 3

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

Model 3210C. 100 Ampere AC Current Standard. Operating Manual

Model CC4041. CC Series Amplifier. Installation and Use Manual

SAS-563B Active Loop Antenna Operation Manual

50 μh Line Impedance Stabilisation Network (AC LISN)

Broadband Power Amplifier

Broadband Step-Up Transformer. User Manual

Model 3110B Biconical Antenna

Model 7000 Low Noise Differential Preamplifier

Autoranging Multimeter Extech EX503

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

SignalOn Series. RF Passive Modules INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

Model CC4052. CC Series Amplifier. Installation and Use Manual

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER

DL102 Counter Loop Amplifier

PI-150 Broadband Power Indicator

BROADBAND PREAMPLIFIER MODEL BPA khz 1 GHz

4 Channel Frequency Conscious Noise Gate. Operation Manual

ELECTRO-MECH SCOREBOARD CO. SL-230 / 330 RF MODEM INSTALLATION MANUAL

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

Log Periodic Dipole Array Antenna

Model 3104C. Biconical Antenna. User Manual

ZOTL40 Mk.II POWER AMPLIFIER USER GUIDE. Linear Tube Audio Takoma Park, MD, USA

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

PA WATT PORTABLE PA SYSTEM PRODUCT MANUAL

1.5µm PbSe Power Detector

Owner s manual. SDA 2175 Semi Digital Amplifier

M-300 Mono power amplifier User s guide

Model 3106 Double-Ridged Waveguide Horn

Transcription:

Page 1 of 10 INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK Model LI-4100 10 khz to 10 MHz

Page 2 of 10 Table of Contents 1.0 Introduction... 3 2.0 Product Description... 4 3.0 Product Specifications... 5 4.0 Important Safety Precautions... 6 5.0 Warranty... 7 6.0 Front and rear panel marking... 8 7.0 LISN Theory... 9 8.0 Typical Performance Data... 10

1.0 Introduction Page 3 of 10 This manual includes product specifications, safety precautions, product maintenance and warranty information. It also includes some basic guidance on LISN operation. Information contained in this manual is the property of Com-Power Corporation. It is issued with the understanding that none of the material may be reproduced or copied without permission from Com-Power.

Page 4 of 10 2.0 Product Description Overview The LI-4100 Line Impedance Stabilization Network was specifically designed for providing standardized line impedance during Electromagnetic Compatibility (EMC) testing in accordance with MIL-STD 461 requirements. In addition, it minimizes the noise generated by equipment other than the EUT to be included in the measurement. The LI-4100 is shipped with two LISN housed in separate enclosures for single phase power applications. For wiring convenience, each LISN has either a black or red shrouded banana for both power and EUT connection. The following items are included with each LI-4100 LISNs. Standard items included: Equipment, accessories, and documents supplied with the LI-4100 LISN are as follows: o Calibration data and Certificate traceable to NIST. o Superior Electric shrouded 100A plugs for EUT and power connection. Optional items o ISO-17025 calibration data and certificate.

Page 5 of 10 3.0 Product Specifications Model: LI-4100 Electrical Frequency Range: 10 khz to 10 MHz Compliant Standards: MIL-STD 461 Number of lines: Max current rating: Max Voltage Rating: Two lines 100 Amp AC, 70 Amp DC 525 VAC, 50/60 Hz (Line to Ground) / 740 VDC Insertion Loss: 5 to 0.2 db (10 khz 100 khz) <0.2 db (100 khz to 10 MHz) Inductor type: 50 µh EUT & Power Connector: 100 Amps Shrouded Superior Electric sockets RF measurement connector: 50Ω, N type (female) Cooling: Forced air Power Adapter for fan: Output: 12 VDC,1 Amp Input: 120 VAC, 60 Hz / 230 VAC, 50 Hz Fuse: 1 Amp, 250 V (T) Adapter output connector Diameter: 2.1 x 5.5 mm Center Positive Operating Temperature: 5 C to 40 C / 40 F to 104 F Mechanical Dimensions of each enclosure (L x W x H): Weight (each network): 10 x 10 x 21 inches / 25.4 x 25.4 x 53.3 cm 17 lb. / 7.7 kg This equipment is designed for indoor use only. 3.1 Other items available from Com-Power SPA-series Spectrum Analyzers LIN-120A, LISN 150 khz 30 MHz, 20 A LI-220A, LISN 10 khz 30 MHz, 20 A LI-125A, LISN 150 khz 30 MHz, 25 A LI-550A, LISN 150 khz 30 MHz, 50 A Special order LISNs with higher voltage and / or current LIT-930 Transient Limiter 9 khz to 30 MHz Cables and connectors

4.0 Important Safety Precautions Page 6 of 10 The LISN must be securely fastened to the earth ground before making any connections to external power. Proper grounding of the LISN not only ensures correct conducted emissions measurements, it also prevents potential high leakage current from presenting a hazard test personnel. To help establish proper grounding the bottom surface of the LISN is unpainted. In addition, the bottom plate has holes for securely bolting the LISN to the ground plane. Only connect power plugs with a protective earth contact into LISN power input port / AE. The protective action must not be negated by the use of a cheater plug or an extension cord without a protective conductor. Caution The LI-4100 LISNs use forced air system to keep the air core inductors cool during the test. Always use the supplied DC adapter to power the internal fan during the test. Do not obstruct the airflow vents. Use the LISNs in a ventilated area. Failure to observe these precautions may result in hazardous conditions for the operator. Overheated LISN may also provide incorrect measurement data or damage the LISN. If the fan stops working discontinue using the LISN and contact Com-Power for further assistance. Environmental conditions This equipment is designed for indoor use to be safe under the following environmental Conditions: Temperature: 5 C to 40 C Maximum relative humidity: 80%

Page 7 of 10 5.0 Warranty Com-Power warrants to its Customers that the products it manufactures will be free from defects in materials and workmanship for a period of 3 years. This warranty shall not apply to: Transport damages during shipment from your plant. Damages due to poor packaging. Products operated outside their specifications. Products Improperly maintained or modified. Consumable items such as fuses, power cords, cables, etc. Normal wear Calibration Products shipped outside the United States without the prior knowlege of Com- Power. In addition, Com-Power shall not be obliged to provide service under this warranty to repair damage resulting from attempts to install, repair, service or modify the instrument by personnel other than Com-Power service representatives. Under no circumstances does Com-Power recognize or assume liability for any loss, damage or expense arising, either directly or indirectly, from the use or handling of this product, or any inability to use this product seperately or in combination with any other equipment. When requesting warranty services, it is recommended that the original packaging material be used for shipping. Damage due to improper packaging will void warranty. In the case of repair or complaint, Please visit our website www.com-power.com and fill out RMA form (http://com-power.com/repairservicereq.asp). Our techincal assistance personnel will contact you with RMA number. Please ensure to have the RMA number stated on shipping documents. 5.1 Maintenance This product contain no user serviceable parts inside. If the unit does not operate or needs calibration, please contact Com-Power Corporation. Any modifications or repairs performed on the unit by someone other than an authorized factory trained technician will void warranty. The exterior surface may be cleaned with mild detergent and then be wiped with a dry, clean, lint-free cloth. Use care to avoid liquids or other foreign objects entering the chassis.

6.0 Front and rear panel marking Page 8 of 10 6.1 Power input port The Model LI-4100 has a 100 Amps Superior Electric pin receptacle on the back panel for connection to external DC or AC power source. The matching shrouded banana socket plug is included with the LISN. See specification table on page 5 of this manual for the voltage and current ratings. 6.2 EUT power port The LI-4100 uses a 100 Amps Superior Electric Shrouded banana socket receptacle as the EUT power port. The matching color coded plug is included for making the connection to the EUT. 6.3 EMI measurement Port The 50 Ω Type 'N' connector located to the right of the EUT Power Port for connecting the Spectrum analyzer or EMI receiver for making conducted noise measurements. 6.4 Grounding bolt (GND) The bolt marked 'GND' are found on both front and back panel of the LISN. This bolt is used for PE grounding with a braid or short wire. This is in addition to mounting the LISN on the RF ground plane using conductive bottom surface. 6.5 Input 12V DC, 1 A The 12V DC input is a standard 5.5mm x 2.1 mm dc power jack to connect power adapter for the Fan. 6.6 Fuse, 1 Amp The fuse is for the Fan operation, it is a 20 x 5mm 1A, 250V (T) fuse. For continued protection against risk of fire, replace only with fuse of the specified type, current and voltage ratings 6.7 Power switch This switch controls the Fan operation. Always turn the fan ON before powering the EUT via LISN.

Page 9 of 10 7.0 LISN Theory 7.1 Overview Line Impedance Stabilization Networks used supply standardized line impedance to the EUT during conducted emissions testing which is independent of the external power line impedance. The standardized impedance enables consistent readings for RF noise measurements on the power line. The model LI-4100 consists of two separate LISN networks housed in separate enclosure for testing EUTs with single phase power requirements. In addition to providing standardized impedance, the LISN also acts as a low pass filter for the power to equipment under test. The LISN blocks RF noise from the power line from reaching the equipment under test, however, the power to the equipment passes through the LISN with minimal effect. This filter comprises of single stage low pass LC filter. Therefore, it has capacitor and an inductor for the filter. The inductor used in the LI-4100 is air core type to eliminate the possibility of saturation and to provide stability. The LISN also provides a low impedance path for the RF noise from the EUT to the measuring equipment, thereby facilitating the measurement of the RF noise. The insertion loss of the measured noise may be significant especially at low frequencies. Therefore, at frequencies below 100 khz, the insertion loss correction factor must be compensated for highest accuracy noise measurement. The figure below is a typical schematic of a 50 µh LISN as specified in MIL-Std 461 standard. Figure 1 Example of an equivalent LISN circuit

Insertion Loss (db) Impedance (Ω) Page 10 of 10 8.0 Typical Performance Data 70 60 50 40 30 20 10 0 0.01 0.1 1 10 Frequency (MHz) Figure 2 - Impedance (AE Port: Open ) compared to Mil-Std 461 requirements. 10 8 6 4 2 0 0.01 0.1 1 10 Frequency (MHz) Figure 3 Insertion Loss