MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY WESTFORD, MASSACHUSETTS

Similar documents
MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY WESTFORD, MASSACHUSETTS

EDGES. Judd D. Bowman, Arizona State University Alan E. E. Rogers, Haystack Observatory

MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY

S S S S S S S D D 11 S11 D 12 S12

Cu 0.37 Brass Cu 0.37 Brass

Wire spacing in wavelengths

EDGES Group Alan E.E. Rogers and Judd D. Bowman Deployment of EDGES at Mileura Station, Western Australia

Implementation of the EDGES Antenna Simulator

NATIONAL RADIO ASTRONOMY OBSERVATORY Charlottesville, VA

Improving Amplitude Accuracy with Next-Generation Signal Generators

To: RFI Group From: Alan E.E. Rogers Subject: Correction antenna temperature for cable attenuation and antenna mismatch

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

MWA Antenna Impedance Measurements

New Ultra-Fast Noise Parameter System... Opening A New Realm of Possibilities in Noise Characterization

VSWR MEASUREMENT APPLICATION NOTE ANV004.

New Features of IEEE Std Digitizing Waveform Recorders

University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium

A Low Noise GHz Amplifier

New Antenna Measurements With and Without the Shield

A Noise-Temperature Measurement System Using a Cryogenic Attenuator

Noise Analysis of AHR Spectrometer Author: Andrew Xiang

Maxim > Design Support > Technical Documents > Application Notes > Wireless and RF > APP 3571

Design and Demonstration of a Passive, Broadband Equalizer for an SLED Chris Brinton, Matthew Wharton, and Allen Katz

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

Autocorrelator Sampler Level Setting and Transfer Function. Sampler voltage transfer functions

Dr. Martina B. Arndt Physics Department Bridgewater State College (MA) Based on work by Dr. Alan E.E. Rogers MIT s Haystack Observatory (MA)

Lecture 16 Microwave Detector and Switching Diodes

University of North Carolina, Charlotte Department of Electrical and Computer Engineering ECGR 3157 EE Design II Fall 2009

Understanding Power Splitters

MWA REVB LNA Measurements

EE 3324 Electromagnetics Laboratory

PLANAR R54. Vector Reflectometer KEY FEATURES

The Phased Array Feed Receiver System : Linearity, Cross coupling and Image Rejection

Vector Network Analyzer Application note

Circuit Characterization with the Agilent 8714 VNA

Gain Lab. Image interference during downconversion. Images in Downconversion. Course ECE 684: Microwave Metrology. Lecture Gain and TRL labs

Trees, vegetation, buildings etc.

Compact VNA - TR1300/1

Low frequency noise measurements in direct detection radiometers

Reflectometer Series:

Comparison of Signal Attenuation of Multiple Frequencies Between Passive and Active High-Pass Filters

Voltage Sensors URV5-Z

Impedance 50 (75 connectors via adapters)

RF300 LARGE LOOP ANTENNA

RF Characterization Report

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

Amateur Extra Manual Chapter 9.4 Transmission Lines

PXIe Contents CALIBRATION PROCEDURE. Reconfigurable 6 GHz RF Vector Signal Transceiver with 200 MHz Bandwidth

Measurements 2: Network Analysis

Datasheet SHF D Synthesized Clock Generator

ME1000 RF Circuit Design. Lab 4. Filter Characterization using Vector Network Analyzer (VNA)

BENCHMARK MEDIA SYSTEMS, INC.

10 Mb/s Single Twisted Pair Ethernet Conducted Immunity Steffen Graber Pepperl+Fuchs

Low Cost Mixer for the 10.7 to 12.8 GHz Direct Broadcast Satellite Market

Calibration Techniques for the Home Lab

Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth Product Note

Lab 9 - AC Filters and Resonance

FCC ID: A3LSLS-BD106Q. Report No.: HCT-RF-1801-FC003. Plot Data for Output Port 2_QPSK 9 khz ~ 150 khz Middle channel 150 khz ~ 30 MHz Low channel

DESIGN AND CHARACTERISATION OF A LOW NOISE ACTIVE ANTENNA (LNAA) FOR SKA

Chapter 12: Transmission Lines. EET-223: RF Communication Circuits Walter Lara

Experiment 1: Instrument Familiarization (8/28/06)

JFET Noise. Figure 1: JFET noise equivalent circuit. is the mean-square thermal drain noise current and i 2 fd

A TECHNIQUE TO EVALUATE THE IMPACT OF FLEX CABLE PHASE INSTABILITY ON mm-wave PLANAR NEAR-FIELD MEASUREMENT ACCURACIES

Saturation of Active Loop Antennas

Interference temperature measurements from 70 to 1500 MHz in suburban and rural environments of the Northeast

PHY 123/253 Shot Noise

Experiment 1: Instrument Familiarization

RECOMMENDATION ITU-R SM Method for measurements of radio noise

Estimation of cross coupling of receiver noise between the EoR fat-dipole antennas

Class #16: Experiment Matlab and Data Analysis

EVLA System Commissioning Results

6.976 High Speed Communication Circuits and Systems Lecture 20 Performance Measures of Wireless Communication

Battery Impedance Measurement

TEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports

VVM measurement with E5061B for replacing 8508A vector voltmeter. May 2013 Agilent Technologies

On-Wafer Noise Parameter Measurements using Cold-Noise Source and Automatic Receiver Calibration

Cobalt Series 20 GHz EXTEND YOUR REACH TM

VGOS MEMO #042 MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY WESTFORD, MASSACHUSETTS August 22, 2016

Isolator-Free 840-nm Broadband SLEDs for High-Resolution OCT

Radiofrequency Power Measurement

Chapter 5. Array of Star Spirals

Radio ETI031 Laboratory Experiments 2: VECTOR NETWORK ANALYSER, ANTENNA and RECEIVER MEASUREMENTS

10 Mb/s Single Twisted Pair Ethernet Implementation Thoughts Proof of Concept Steffen Graber Pepperl+Fuchs

Description RF Explorer RFEAH-25 1 is a 25mm diameter, high performance near field H-Loop antenna.

Calibration of RF-Voltage on Oscilloscopes

Compact VNA - TR7530. Extended Specifications EXTEND YOUR REACH TM

Preliminary Users Manual for the Self Contained Return Loss and Cable Fault Test Set with Amplified Wideband Noise Source Copyright 2001 Bryan K.

Overcoming Mixer Measurement Challenges

Categorized by the type of core on which inductors are wound:

Experimental Evaluation Scheme of UWB Antenna Performance

SENSOR AND MEASUREMENT EXPERIMENTS

Glossary of VCO terms

Application Note 5525

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS

ECE 2006 University of Minnesota Duluth Lab 11. AC Circuits

Phase calibration in prototype VLBI2010 systems

Vector Network Analyzer

Keysight Technologies Vector Network Analyzer Receiver Dynamic Accuracy

Transcription:

To: From: EDGES MEMO #104 MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY WESTFORD, MASSACHUSETTS 01886 January 14, 2013 Telephone: 781-981-5400 Fax: 781-981-0590 EDGES Group Alan E.E. Rogers Subject: EDGES-2 Laboratory tests of absolute calibration Following the initial tests given in memo 82 this memo gives more details of the method and corrections needed to get higher accuracy. 1] Review of fundamental algorithms (based on Rogers & Bowman 2012) LNA power output P ant ( 1 a ) 2 2 a F 2 2 P= T Γ F Where + Tu Γ +Γ F T + T + T ( cosφ sinφ) a c s ( 1 2 ) ( 1 ) a F = Γ Γ Γ φ = phase of Γ a F T ant = temperature of sky for lossless antenna Γ a = antenna S11 Γ = LNA S11 0 T u = uncorrelated noise wave T s, T c = sine and cosine components of correlated noise T 0 = added noise which is independent of input While the LNA noise parameters T u, T s, T c and T 0 vary with frequency the expression above exactly predicts the dependence of the power output on the antenna reflection coefficient, Γ. When the LNA is connected to any passive lossy load of uniform temperature T, T ant = T and is the S11 of the load. If the load has lossy components at different temperatures then a circuit model is required to estimate the equivalent temperature. For the case of a lossless antenna connected to a lossy 50Ω transmission line it can be shown that ( 1 ) T = T L+ T L ant sky amb a Γ a 1

and L= L ( 1 2 2 ) ( 1 2 m Γa Lm Γ a ) where L m is the line loss when matched and to the LNA. 2] 3-position switch Γ a is the S11 measured at the cable end connected In order to remove the bandpass and the effects of slow gain changes the LNA is switched between the antenna, a load and a load plus noise from a diode. In order to calibrate the system is connected to the following: a) Ambient load b) Hot load c) Open cable Using the measured S11, temperature, loss estimates and 3-position switched spectra for these devices the following effects are removed: a) Noise diode temperature errors b) Offset due to different temperature and S11 of the internal load of the 3-position switch and the noise wave parameter values are determined. 3] Calibration tests Finally the system is connected to an artificial antenna made from a hot tungsten filament. The output of this test source can be estimated using a measurement of the filament resistance to estimate the temperature and a circuit model to estimate the relatively small losses. 4] Circuit model test of algorithms A test of the algorithms can be made using the simple circuit in which power is proportional to the voltage across the LNA impedance, Z, in which case ( ( ) lna ( )) 2 2 sky e a e a Pα T RZ + T RZ Z Z + Z Where Z a is the antenna impedance. In addition to the simple model. Data simulated using the full LNA circuit model given in memo 62 produced the expected temperature of the antenna simulator to within 1 mk from 50 to 200 MHz. 4] Test set-up The EDGES-2 electronics was set-up on the bench shielded from the very strong local interference in the Haystack control room. These signals are so strong that they can leak into the input through the shield of the connections to the input. The open box shield in Figure 1A was found to provide adequate shielding so that it was not necessary to work in a screen room. A HP8753C vector network analyzer shown in Figure 1B was set-up close to the EDGES so that the input of the LNA could be reached with a 24 Gortex VNA cable. The 2 VNA ports were setup and calibrated. Port A was set with a low enough power level (-10 dbm plus 10 db attenuator) to avoid saturation of the LNA first and second stages. The effects of second stage saturation, which effect the LNA impedance, are evident above -17 dbm. Port B was set-up at 0 dbm with 0 db attenuators for optimum accuracy in the measurement of S11 of the ambient hot 2

load and antenna simulator shown in figures 1C and 1D respectively with covers removed. All VNA measurements were made with 100 point averaging with 201 spectral points from 50 to 200 MHz. All calibration was done using male short, open and load. Because the load was 50 ohms within 0.1 ohm it was not necessary to make the corrections described in memo 86 but it was necessary to remove the female to female adapter and make a delay correction when measuring the LNA S11 at the female input of the LNA. 5] Details for high accuracy a) Calibration load S11 and loss The calibration load S11 is measured at ambient (~298K) and hot (~368K). While the loss between the LNA and the load has no effect at ambient as the entire structure is at a uniform temperature the loss at the hot temperature estimated to be 0.02 db at 100 MHz reduces the effective temperature from that measured by the Fluke thermocouple probe by about 0.5 K. In addition the loss puts a slope and curvature on the spectrum since the loss is resistive and increases with the square root frequency as a result of the decreasing skin depth. Corrections for the S11 and loss are made in the software which iteratively corrects measured spectra for error in the noise diode and comparison load offset as described in memo 96. b) Temperature of LNA and comparison load. Like a VNA EDGES-2 is assumed to remain at a constant temperature during calibration. Further the 3-position switch needs to be running for about 30 minutes prior to any measurement to ensure a repeatable temperature distribution within the front-end. The primary effect is the change of temperature the comparison loss which results in a constant offset. While EDGES-2 should be operated in a constant temperature environment the application of linear corrections based on calibration at 2 temperatures should allow accurate results to be obtained for operation in an environment in which the temperature changes slowly. c) Calibration verification using artificial antenna The tungsten filament hot load provides a near ideal artificial antenna since the load is mismatched, has low loss and has a high temperature that can be accurately estimated from the change in resistance between ambient when no current is applied and hot when current is applied. However several issues have arisen: 1) A filament with intermediate supports can produce changes in S11 and temperature with orientation or vibration. This problem is solved by using a fuse style lamp in which the filament is only supported at the ends. 2) It is not clear if the filament is made of pure tungsten or contains certain enhancing impurities like thorium which makes the filament less brittle. However experimental data on thoriated tungsten show that it has little effect on the resistance vs temperature. If impurities do effect the resistance curve then filament source still provides a check on the spectral flatness and not the temperature scale. 3) Loss in the inductor needed to isolate the power source In order to reduce the loss a handmade solenoid inductor made of 20 turns of 30 a.w.g. wire on a 5mm diameter rod. The loss of the parts of the filament load which remain at ambient can be measured from S11 measurements a unit in which a filament is absent and shorted. 4) Loss at ends of the filament 3

A small reduction of the effective temperature results from the ends of the filament. First this is very small, a few millimeters out of several centimeters and second the reduced temperature results in lower resistance so the effect on the temperature determined from the change of resistance is compensated. In the 50-200 MHz range the tungsten wire diameter is less than the skin depth so there is no effect on the spectral flatness. 6] S11 and temperature sensitivity from simulations Data generated from the circuit model of the LNA was used to test the LNA optimization. For an antenna with S11 of -12 db the rms deviation (after removal of scale) due to error in the measured temperature are relatively small at 13 mk per 1000K per K. The results of errors S11 amplitude and phase are summarized in table below Amplitude Phase Antenna 70 mk/0.01 db 400 mk/degree Noise wave cable 16 mk/0.01 db 50 mk/degree LNA 30 mk/0.01 db 400 mk/degree Loads 30mK/dB 5 mk/degree Table 1 Effect of error in S11 measurements These results are for an optimized LNA with S11 about -20 db and an antenna temperature of 1000 K. Improving the antenna match reduces the sensitivity to errors in S11 amplitude in proportion S11 power while the sensitivity to phase S11 errors are only reduced in proportion to S11 voltage. Errors which result from errors in the loss estimates are independent the LNA and its calibration. 7] Results of tests with artificial antenna Measurements of S11 of the artificial antenna, LNA, cable used to calibrate noise wave parameters, hot load, and ambient load are shown in Figure 2A,B,C and D respectively. In each case the S11 data is fit with a Fourier series in a least squares sense. This reduces the noise in the measurements and allows accurate interpolation to be observed spectral frequencies which can have a different spacing than those of the S11 measurements. The 3-position switched spectra of the artificial antenna, hot load, ambient load, noise wave calibration are shown in Figures 3 A,B,C and D. In each case the residuals is to the fit to the spectrum is shown at the top. Figure 4 shows the noise wave parameters derived from the data and Figure 5 shows the corrected spectrum of the artificial antenna and the residuals to a constant 1587 K. The rms deviation from a constant shown at the top of Figure 5 is 842 milli K. While this result is a long way from a goal of a few milli K the effect of errors in S11 are more than four times larger than expected for an antenna S11 magnitude of -15 db compared with the artificial antenna S11 magnitude of about -5 db. 4

8] Comments on results and plans for improvements a) LNA noise and S11 The LNA noise is higher than expected at the low end of the 50-200 MHz band. This may be due to some losses in the 2µH ferrite core surface mount inductors used between the input and the HEMT. Tests are planned using air core inductors with lower loss. It also is expected that the variation of the LNA noise waves will be well represented by a lower order polynomial than the fifth order used to fit the spectrum shown in figure 3D so clearly there is some unwanted rapid frequency dependence in the LNA circuit which needs to be removed. b) VNA accuracy The sensitivity to the VNA phase error poses a challenge in the measurement of the LNA S11 which needs to be made at the low level to avoid saturating the 2 nd stage. Longer averaging times and more care is needed in this measurements. More tests and checks on the VNA calibration at these low levels are in progress 5

Fig. 1A Edges in open box shield connected to cable to calibrate noise waves. Fig. 1B HP8753C VNA Fig. 1C. Hot/Cold load Fig. 1D. Filament load Figure 1 6

Figure 2A Figure 2B Figure 2C Figure 2D Figure 2. S11 measurements of the artificial antenna, LNA, cable used to measure the LNA, cable used to measure the LNA noise waves and calibration load at 100 C. The S11 of the calibration load at 25 C which is not shown is about -40 db. 7

Figure 3A Figure 3B Figure 3C Figure 3D Figure 3. The calibrated spectra of the artificial antenna hot and ambient loads and cable used to calibrate the LNA noise waves. The residuals to each fit are plotted at the top of each figure. 8

Figure 4. Noise waves. The thick line is the phase of the correlated wave. Figure 5 Calibrated spectrum of artificial antenna after corrected for losses of 0.008 db. 9